Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inductively coupled plasma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Arsenic Exposure Causes Global Changes in the Metalloproteome of Escherichia coli

Arsenic is a toxic metalloid with differential biological effects, depending on speciation and concentration. Trivalent arsenic (arsenite, AsIII) is more toxic at lower concentrations than the pentavalent form (arsenate, AsV). In E. coli, the proteins encoded by the arsRBC operon are the major arsenic detoxification mechanism. Our previous transcriptional analyses indicate broad changes in metal uptake and regulation upon arsenic exposure. Currently, it is not known how arsenic exposure impacts the cellular distribution of other metals. This study examines the metalloproteome of E. coli strains with and without the arsRBC operon in response to sublethal doses of AsIII and AsV. Size exclusion chromatography coupled with inductively coupled plasma mass spectrometry (SEC-ICPMS) was used to investigate the distribution of five metals (56Fe, 24Mg, 66Zn, 75As, and 63Cu) in proteins and protein complexes under native conditions. Parallel analysis by SEC-UV-Vis spectroscopy monitored the presence of protein cofactors. Together, these data reveal global changes in the metalloproteome, proteome, protein cofactors, and soluble intracellular metal pools in response to arsenic stress in E. coli. This work brings to light one outcome of metal exposure and suggests that metal toxicity on the cellular level arises from direct and indirect effects.

59 BASIC BIOLOGICAL SCIENCES↗

Collaborative Study for Certification of Trace Elements in Uranium Ore Concentrate CRMs UCLO-1, UCHI-1, and UPER-1

Trace impurity patterns are important nuclear forensic signatures in uranium ore concentrates (UOCs) and Certified Reference Materials (CRMs) are used to validate the analysis methods employed by end users. Herein, we discuss the certification campaign for three new UOC CRMs from the National Research Council Canada: UCLO-1 (https://doi.org/10.4224/crm.2020.uclo-1), UCHI-1 (https://doi.org/10.4224/crm.2020.uchi-1), and UPER-1 (https://doi.org/10.4224/crm.2020.uper-1). This study involved 15 laboratories from 10 countries, using sector-field and (triple) quadrupole inductively-coupled plasma mass spectrometry to analyze 64 trace element impurities. We discuss the importance of the acids used for sample digestion, difficulties analyzing in a high uranium matrix, and data combination and uncertainty evaluation for this large dataset.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Fe–N–C Boosts the Stability of Supported Platinum Nanoparticles for Fuel Cells

The poor durability of Pt-based nanoparticles dispersed on carbon black is the challenge for the application of long-life polymer electrolyte fuel cells. Recent work suggests that Fe- and N-codoped carbon (Fe-N-C) might be a better support than conventional high-surface-area carbon. In this work, we find that the electrochemical surface area retention of Pt/Fe-N-C is much better than that of commercial Pt/C during potential cycling in both acidic and basic media. In situ inductively coupled plasma mass spectrometry studies indicate that the Pt dissolution rate of Pt/Fe-N-C is 3 times smaller than that of Pt/C during cycling. Density functional theory calculations further illustrate that the Fe-N-C substrate can provide strong and stable support to the Pt nanoparticles and alleviate the oxide formation by adjusting the electronic structure. The strong metal-substrate interaction, together with a lower metal dissolution rate and highly stable support, may be the reason for the significantly enhanced stability of Pt/Fe-N-C. In conclusion, this finding highlights the importance of carbon support selection to achieve a more durable Pt-based electrocatalyst for fuel cells.

25 ENERGY STORAGE↗

Total Mercury Analysis of Radioactive Waste Containing Multiple Mercury Species

In this work, a direct mercury analyzer (DMA) was used to analyze total mercury in radioactive waste samples containing methylmercury and other forms of mercury including Hg o (elemental) together with inorganic ionic mercury species and complexes. These samples were also analyzed using Cold Vapor Atomic Absorption Spectroscopy (CVAAS) and/or Inductively Coupled Plasma Mass Spectroscopy (ICMS). Comparative statistical evaluation of the results from spike solutions/simulants, liquid radioactive waste samples, and interlaboratory performance test samples demonstrated that the various methods generated accurate and/or equivalent total mercury data and equivalent precision (2σ ± < 20%). Triplicate total mercury analysis of an exemplar radioactive waste resulted in an average value of 54.1 mg/L (as Hg) using CVAAS, 55.1 mg/L using ICPMS and 56.0 mg/L using DMA. A primary advantage of the DMA in a radioactive environment is avoiding multi-step, labor-intensive, time-consuming and waste-producing sample preparation protocols needed for CVAAS and ICPMS. DMA was determined to be the preferred method for measuring total mercury in the Savannah River National Laboratory (SRNL) radioanalytical laboratory based on analytical performance combined with ease of use in a radiological containment unit.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Origins of wear-induced tungsten corrosion defects in semiconductor manufacturing during tungsten chemical mechanical polishing

During chemical mechanical polishing (CMP) process optimization, a unique corrosion defect was identified in the tungsten (W) contact plugs, which were investigated to develop practical solutions to improve CMP mass productivity. The corrosion defect occurred in the absence of external incident energy and was observed to occur only at the W plugs connected to the P + /n-well close to the wafer edge. To examine the root cause of the corrosion, a series of experiments was carried out at each W CMP step, using in-line defect inspection. Additional experiments were conducted using on-line inductively coupled plasma mass spectrometry (ICP-MS) to understand pH- and potential-dependent electrochemical dissolution behaviors of W. Experimentally, W corrosion was confirmed to be exacerbated if the surface oxide of the W plugs is removed by the deionized water (DIW) rinsing step under wafer pressurization, then exposed to DIW and alkaline cleaning solution. Although the DIW rinsing step is commonly performed to clean polishing pads right after the main polishing, a small amount of applied pressure (0.5 psi) without slurry supply can lead to corrosion defects. Finally, this wear-induced corrosion of the W plugs can be prevented by removing the applied pressure during the post DIW rinsing step of W CMP.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic layer etching (ALE) of III-nitrides

Atomic layer etching (ALE) was performed on (Al, In, Ga)N thin films using a cyclic process of alternating Cl 2 gas absorption and Ar + ion bombardment in an inductively coupled plasma etcher system. The etch damage was characterized by comparing photoluminescence of blue single quantum well light-emitting diodes before and after the etch as well as bulk resistivities of etched p-doped layers. It was found that etched surfaces were smooth and highly conformal, retaining the step-terrace features of the as-grown surface, thus realizing ALE. Longer exposures to the dry etching increased the bulk resistivity of etched surfaces layers slightly, with a damaged depth of ∼55 nm. With further optimization and damage recovery, ALE is a promising candidate for controlled etching with atomic accuracy. Finally, it was found that Al 0.1 Ga 0.9 N acts as an etch barrier for the ALE etch, making it a suitable etch to reveal buried V-defects in III-nitride light emitting diodes.

Atomic-layer etching↗

Plutonium Co-precipitation with Calcite

The mobility of plutonium (Pu) in the environment is affected by Pu–mineral interactions, such as adsorption–desorption and structural incorporation. Calcite (CaCO 3 ) is a common secondary phase in near surface environments and a major component of many rocks and soils and is expected to form as an alteration product of cement-based materials planned for use in geological repositories. The reactivity of the calcite surface and its ability to tolerate significant variations in its chemical composition through substitution of Ca for other cations make calcite a potentially important sink for environmental contaminants. Here, single crystals of calcite were synthesized from aqueous solutions in equilibrium with air containing Pu as either Pu(VI) or Pu(IV) and characterized using a combination of laser ablation inductively coupled plasma mass spectrometry (LA–ICP–MS) and X-ray absorption spectroscopy (XAS). These data are used to assess the amount, structure, and oxidation state of Pu co-precipitated into calcite, providing insight into the potential for Pu sequestration in calcite precipitates. Overall, the XAS and LA–ICP–MS data support the co-precipitation of plutonyl [Pu(VI/V)] in the bulk calcite, although the exact nature of the co-precipitated Pu complex is difficult to elucidate in the synthesized material. Co-precipitated plutonyl could be incorporated in either distorted Ca lattice sites or defect sites, and we provide evidence to suggest that Pu(VI) is reduced mainly to Pu(V) in the precipitated solid. LA–ICP–MS additionally shows that the co-precipitation of Pu(VI/V) is favored over the co-precipitation of Pu(IV). Altogether, our results suggest that Pu sequestration in calcite under environmental conditions could immobilize Pu and isolate it from groundwater interactions in contaminated environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of measurement techniques and sorption of radium-226 in low and high salinity aqueous samples

Human activities have the potential to redistribute radium (Ra) in the marine environment in a manner that may necessitate monitoring or management of subsequent human or environmental exposures. There is therefore a need to identify accurate and accessible techniques for Ra measurement in high salinity samples and to describe the distribution of Ra in estuarine and marine environments, but most efforts in these areas have focused on low salinity matrices. In addition, rapid and reliable measurements are crucial for time-sensitive samples such as short-lived isotopes or emergency situations. The objective of this study is to describe the limits of detection, cost, and relative ease for measurement of Ra in both low and high salinity aqueous samples via three analytical methods: liquid scintillation counting (LSC), high purity germanium (HPGe) gamma spectrometry, and inductively coupled plasma mass spectrometry (ICP-MS). To contextualize these measurements for real-world scenarios, the partitioning of 226 Ra to substrates relevant to the marine environment was also characterized. Although HPGe detection with solid phase extraction had the lowest limit of detection for low salinity samples (0.27 Bq L −1 ), poor 226 Ra recovery for high salinity samples and high materials costs make this method prohibitive for many users. Limits of detection for high salinity samples were lower for LSC (1.28 Bq L −1 ) than for ICP-MS without dilution (11.4 Bq L −1 ), but significant and unexpected degradation of the high salinity LSC standards was observed after six months. Furthermore, our preferred measurement method for high salinity Ra samples is ICP-MS with sample dilution as necessary to reduce matrix effects.

07 ISOTOPE AND RADIATION SOURCES↗

Bioaccumulation of contaminants in Scarabaeidae and Silphidae beetles at sites polluted by coal combustion residuals and radiocesium

Anthropogenic contamination from coal-fired power plants and nuclear reactors is a pervasive issue impacting ecosystems across the globe. As a result, it is critical that studies continue to assess the accumulation and effects of trace elements and radionuclides in a diversity of biota. In particular, bioindicator species are a powerful tool for risk assessment of chemically contaminated habitats. Using inductively coupled plasma mass spectrometry (ICP-MS) and auto-gamma counting, we analyzed trace element and radiocesium contaminant concentrations in Scarabaeidae and Silphidae beetles (Order: Coleoptera), important taxa in decomposition and nutrient cycling, at contaminated and reference sites on the Savannah River Site, South Carolina, U.S. Our results revealed variability in trace element concentrations between Scarabaeidae and Silphidae beetles at uncontaminated and contaminated sites. Compared to Scarabaeidae, Silphidae had higher levels of chromium (Cr), copper (Cu), iron (Fe), manganese (Mn), nickel (Ni), and zinc (Zn). Unexpectedly, concentrations of Cr, Cu, and Ni were higher in both taxa at the uncontaminated sites. Scarabaeidae and Silphidae beetles at the coal combustion waste site consistently had high concentrations of arsenic (As), and Scarabaeidae had high concentrations of selenium (Se). Of the 50 beetles analyzed for radiocesium levels, two had elevated radioactivity concentrations, both of which were from a site contaminated with radionuclides. Furthermore, our results suggest carrion beetles may be particularly sensitive to bioaccumulation of contaminants due to their trophic position and role in decomposition, and thus are useful sentinels of trace element and radionuclide contamination.

59 BASIC BIOLOGICAL SCIENCES↗

Measuring calcium content in plants using NEXAFS spectroscopy

Calcium is important for the growth and development of plants. It serves crucial functions in cell wall and cell membrane structure and serves as a secondary messenger in signaling pathways relevant to nutrient and immunity responses. Thus, measuring calcium levels in plants is important for studies of plant biology and for technology development in food, agriculture, energy, and forest industries. Often, calcium in plants has been measured through techniques such as atomic absorption spectrophotometry (AAS), inductively coupled plasma–mass spectrometry (ICP-MS), and electrophysiology. These techniques, however, require large sample sizes, chemical extraction of samples or have limited spatial resolution. Here, we used near-edge X-ray absorption fine structure (NEXAFS) spectroscopy at the calcium L- and K-edges to measure the calcium to carbon mass ratio with spatial resolution in plant samples without requiring chemical extraction or large sample sizes. We demonstrate that the integrated absorbance at the calcium L-edge and the edge jump in the fluorescence yield at the calcium K-edge can be used to quantify the calcium content as the calcium mass fraction, and validate this approach with onion epidermal peels and ICP-MS. We also used NEXAFS to estimate the calcium mass ratio in hypocotyls of a model plant, Arabidopsis thaliana , which has a cell wall composition that is similar to that of onion epidermal peels. These results show that NEXAFS spectroscopy performed at the calcium edge provides an approach to quantify calcium levels within plants, which is crucial for understanding plant physiology and advancing plant-based materials.

59 BASIC BIOLOGICAL SCIENCES↗

Chemistry imaging and distribution analysis of rare earth elements in coal using LIBS and LA-ICP-MS instruments

Currently, demand for rare earth elements (REEs) increased significantly. Coal is actively evaluated as potential economic sources for extraction of REEs. Here, in this work, laser-induced breakdown spectroscopy (LIBS) was evaluated for rapid estimation of REEs content and their distribution in the natural coal samples. The results were compared with similar laser ablation–inductively coupled plasma–mass spectrometry (LA-ICP-MS) measurements. Thirteen coal samples (nine standard samples and five natural samples) were used in this study. Powder samples were pressed into pellets while coal chunks were directly ablated for data recording. Pellets of the powder standard samples were used to optimize the data acquisition system and then data recorded with this optimized system was used to identify the proper data acquisition and analysis models. After establishing the proper data acquisition system and analysis model using the standard samples, natural coal samples in powder form and their chunks were utilized to record LIBS and LA-ICP-MS spectra. Multivariate calibration models were developed using four of the natural samples, which were evaluated by predicting the REE content in the fifth sample. Principal component analysis was performed on the LIBS data obtained from the natural samples and it classified all the samples with high accuracy. Two-dimensional (2D) elemental mapping on coal chunk samples was also performed using both LIBS and LA-ICP-MS to study the distribution of REEs in the samples. The resulting elemental images and their correlations can be used to infer mineral distributions.

01 COAL, LIGNITE, AND PEAT↗

Organic matter concentration and composition of experimentally burned open air and muffle furnace vegetation chars across differing burn severity and feedstock types from Pacific Northwest, USA (v4).

This dataset represents results from an experimental study designed to compare how the chemical composition of organic matter changes across different burn conditions and feedstock materials. The dataset provides both solid and dissolved phase bulk concentration and organic matter characterization data from experimentally generated chars. Chars were created in a closed muffle furnace or on an open burn table from four different feedstock species representing vegetation commonly impacted by fire regimes across the Pacific Northwest, USA. This data can be used to compare how different burn conditions may influence resultant organic matter chemistry and help further our understanding of potential biogeochemical impacts on river corridors post-fire. This dataset is comprised of one data package readme, one data dictionary (dd), one file level metadata (flmd), fourteen burn table videos, burn table video metadata and three folders containing (A) data; (B) metadata and protocols; and (C) photos. The folder names and the file name of the data package readme include a version number which will be updated with future iterations of this data package. The data folder includes (1) solid carbon and solid nitrogen; (2) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) and total dissolved nitrogen (TN); (3) pH; (4) thermocouple time series temperature; (5) methods codes; (6) installation methods; (7) excitation emissions matrix (EEM) methods information; (8) a folder of excitation emissions matrix (EEM) fluorescence and absorbance spectra in dissolved organic matter and EEMs processing instructions; (9) solid state carbon-13 and solution state phosphorus nuclear magnetic resonance (13-C NMR and 31-P NMR) data and methods; (10) benzene polycarboxylic acid (BPCA) concentration and stable isotope data; (11) FTICR-MS methods; (12) Inductively coupled plasma (ICP) data for total calcium, magnesium, iron, aluminum, potassium, phosphorus, sodium, and sulfur along with sodium hydroxide-ethylenediaminetetraacetic acid (sodium hydroxide-EDTA) extractable calcium, magnesium, iron, aluminum, potassium, phosphorus, and sulfur; (13) a folder of phosphorus, carbon, and nitrogen X-ray absorption near edge structure (P-XANES, N-XANES, C-XANES) data for samples and standards; (14) P-XANES, N-XANES, C-XANES methods; (15) molybdate reactive phosphorus; and (16) folder of high resolution characterization of organic matter via 21 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) generated through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory). The FTICR folder contains .txt data files and a subfolder containing instruments for using Formularity (https://omics.pnl.gov/software/formularity) and an R script to process the data based on the user's specific needs. The metadata and protocols folder includes (1) international geo-sample number (IGSN) mapping file (2) burn and laboratory metadata; (3) burn protocol; (4) laboratory protocol; (5) vegetation collection metadata; and (6) vegetation collection protocol. The folder contains photos of the solid chars. All files are .csv, .txt, .pdf, .jpg, .jpeg, .R, .ref, or .mp4. The data package was originally published October 2022 (v1). It was updated April 2023 (v2; new data files), September 2023 (v3; new and corrected data files), and September 2024 (v4; new and added/updated files). Metadata files were also updated to reflect these changes. See the change history section in the readme for more details.

54 ENVIRONMENTAL SCIENCES↗

Round Robin Analysis of Uranium Isotopics on Cotton Swipes Measured Using Microextraction-Based Sampling Versus Conventional Bulk Analysis

A comparison of microextraction sampling methods to directly analyze uranium isotopics on cotton swipes was performed concurrently with traditional bulk-processing methods. For the microextraction sampling approach, two different detection platforms were evaluated, a quadrupole-based inductively coupled plasma mass spectrometer (ICP-MS) and the liquid sampling-atmospheric pressure glow discharge (LS-APGD) coupled to an Orbitrap mass spectrometer. Results presented from this innovative sampling approach (i.e., microextraction) are compared with a more traditional approach employed for analysis of cotton-based environmental swipes, namely bulk ashing/digestion, separation, and subsequent analysis by high-precision multi-collector ICP-MS. Overall, the microextraction approach proved to be a reliable and accurate means to determine isotopic ratios of uranium collected on cotton swipes. The ICP-MS-based detection had relative standard deviations of <0.65% for the major isotopic determinations, whereas the LS-APGD-Orbitrap method had relative standard deviations of <3%. The percent relative difference for the 235 U/ 238 U ratios, in comparison to the expected values, was <1% for ICP-MS and <4% for the microplasma-Orbitrap method. Additionally, the microextraction ICP-MS accurately (<2%) and precisely (<5%) determined the minor isotopic compositions (i.e., 234 U/ 238 U and 236 U/ 238 U).

ICP-MS↗

Evolution of structure and transport properties of the Ba 8 Cu 16 P 30 clathrate-I framework with the introduction of Ga

Two type-I clathrates were synthesized by introducing Ga into the framework of the Ba 8 Cu 16 P 30 type-I clathrate. The introduction of minute amounts of Ga, 1.9% Ga/M total (where M total = Cu + Ga), resulted in the disturbance of the completely ordered Pbcn superstructure of Ba 8 Cu 16 P 30 . Ba 8 Cu 15.43(2) Ga 0.3 P 30.26(3) crystallizes in a partially ordered orthorhombic Pmna clathrate-I superstructure with five out of 15 framework sites being jointly occupied by metal+phosphorus. Increasing the Ga content resulted in all framework sites being occupied by metal + phosphorus in the archetype cubic Pm n clathrate-I crystal structure of Ba 8 Cu 14.5(3) Ga 1.3 P 30.2(4) with 8.2% Ga/M total . A combination of energy dispersive x-ray spectroscopy, inductively coupled plasma mass spectroscopy, and single crystal x-ray diffraction was used to determine the structures alongside the compositions. The positional disorder was verified by 31 P solid state NMR spectroscopy. Characterization of the transport properties indicated that the Ga-substituted samples exhibit higher Seebeck coefficients and electrical resistivities compared to its pristine counterpart, in line with the expected reduction of the hole concentration due to Ga/Cu substitution. Moderate improvements in the thermoelectric power factor and overall figure-of-merit were observed for samples with 6.9% and 3.8% Ga/M total as compared to those for the pristine Ba 8 Cu 16 P 30 clathrate. Finally, band structure calculations shed light on how Ga substitution affects the electronic structure and thermoelectric properties of studied clathrates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploration of a Combined LIBS and LA-ICP-MS Approach for Apatite Characterisation

A combined laser‐induced breakdown spectroscopy (LIBS) and laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) method is demonstrated for comprehensive apatite analysis. These measurements provide elemental imaging that can be used as a screening technique for chemical selection of grains for subsequent analysis (e.g., U‐Pb geochronology) or can be used to understand elemental distributions within a single grain that would have direct textural‐chemical implications (e.g., zoning patterns). Adding LIBS as a simultaneous measurement, to LA‐ICP‐MS U‐Pb geochronology, allowed for the direct determination of F (H and O show promise for future applications) in addition to major and trace elements of interest. Here, the quantitative measurements were validated against a series of apatites with known values and used to characterise a wide range of samples. Fluorine detection limits were determined to be as low as 70 μg g ‐1 F (broadband CMOS detector) and 4.2 μg g ‐1 F (ICCD detector). U‐Pb age dating was simultaneously collected by LA‐ICP‐MS with the quantitative elemental data from LIBS, providing a comprehensive method for geochronology.

Apatite↗

Impact of carrier wafer on etch rate, selectivity, morphology, and passivation during GaN plasma etching

The choice of carrier wafer was found to significantly influence etch rates, selectivity, and morphology in GaN micropillar etching in a Cl 2 -Ar high-density inductively coupled plasma. 7 × 7 mm 2 GaN on sapphire chips with a plasma-enhanced chemical vapor deposition SiO 2 hard mask was etched on top of 4-in. fused silica, silicon carbide, silicon, sapphire, aluminum nitride, and high purity aluminum carriers. Silicon and silicon carbide carriers reduced GaN:SiO 2 selectivity because incidental SiCl x and CCl x etch products from the carriers attack the SiO 2 mask. Aluminum nitride and high-purity aluminum carriers yielded the highest GaN:SiO 2 selectivities due to the deposition of Al-based etched by-products, while the highest GaN etch rate was achieved using the sapphire carrier since it was the most inert carrier and did not sink any Cl 2 . Overall, results indicate that SiO 2 and Al may be used as passivation materials during GaN etching, as vertical profiles were achieved when SiO 2 or Al is redeposited from the fused silica and aluminum carriers, respectively. Floor pitting, trenching, sidewall roughness, and faceting were all influenced by carrier wafer type and will be discussed.

36 MATERIALS SCIENCE↗

Optically pumped deep-UV multimode lasing in AlGaN double heterostructure grown by molecular beam homoepitaxy

Multimode lasing at sub-300 nm wavelengths is demonstrated by optical pumping in AlGaN heterostructures grown on single-crystal AlN substrates by plasma-assisted molecular beam epitaxy. Edge-emitting ridge-based Fabry–Pérot cavities are fabricated with the epitaxial AlN/AlGaN double heterostructure by a combined inductively coupled plasma reactive ion etch and tetramethylammonium hydroxide etch. The emitters exhibit peak gain at 284 nm and modal linewidths on the order of 0.1 nm at room temperature. The applied growth technique and its chemical and heterostructural design characteristics offer certain unique capabilities toward further development of electrically injected AlGaN laser diodes.

36 MATERIALS SCIENCE↗

Noninvasive THz-TDS measurements of plasma bounded and optically shielded by Hall thruster wall material

We experimentally demonstrate the capability of terahertz time-domain spectroscopy (THz-TDS) to noninvasively measure the electron density and collision frequency of plasma bounded and optically shielded by Hall thruster wall material. This paper augments the standard THz-TDS plasma diagnostic theory to account for plasma boundaries, presents THz optical property measurements of three different wall materials (grades M, M26, and HP boron nitride composite), and provides electron density and collision frequency measurements of an inductively coupled plasma bounded and optically shielded by each wall material. We find that the electron density measurement capability is weakly impacted by the boundaries, whereas the electron collision frequency measurement capability is strongly reduced by the boundaries. Here, the bounded plasma electron density trends deviate substantially from those of the unbounded plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗