Airborne infrared astronomy
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
To meet the need for a reliable, fast imaging system capable of being taken rapidly on and off the telescope, a simple, inexpensive, and compact Cassegrain reimaging system for scanning IR images was constructed. Using commercially available components without requiring close mechanical tolerances, the design solves the problem of beam stability pointed out by Koornneef and van Overbeeke (1976). For the moving-iron galvanometer scanner, it is noted that at the imaging frequency of 0.5 Hz, hysteresis in image plane motion was found to be less than 0.2 arc sec for a 64-arc sec scan, and the deviation from linearity with a triangular wave input was found to be less than 0.3 arc sec. This system and a scanning secondary were used to image Venus at 11.5 microns, and compared with the scanning secondary, the reimaging system did not appear to contribute any additional noise, considerably improved mechanical reliability, and eliminated cross-scan motion
(Previously announced in STAR as N82-29155)
Continuing plans for a large deployable reflector (LDR), conceived as a 10- to 30-m-diameter clear-aperture telescope, operating at wavelengths from 1000 microns to a diffraction-limited 30 microns, and to be placed in orbit for a life of 10 years by the Space Shuttle, are discussed. The primary reflector will be composed of a number of closely packed hexagonal segments of glass or lightweight composite material and attached to a truss integrating structure through position actuators providing three degrees of freedom for each segment. Technical aspects of optical design, surface measurement systems, deployment, and detectors are discussed, as are practical and fiscal limitations.
Highlights are presented of studies of the emission mechanisms in the 4 to 8 micron region of the spectrum using a circular variable filter wheel spectrometer with a PbSnTe photovoltaic detector. Investigations covered include the spectroscopy of planets, stellar atmospheres, highly obscured objects in molecular clouds, planetary nebulae, H2 regions, and extragalactic objects.
A liquid helium-cooled, 24 detector grating spectrometer was developed and used for low resolution astronomical observations in the 5 to 14 micron spectral range. The instrument operated on the 91 cm Kuiper Airborne Observatory, the 3 m IRTF (Mauna Kea), the 3 m Shane telescope Observatory, the 3 m Shane telescope (Lick Observatory), and the 152 cm NASA and University of Arizona telescope. The detectors are discrete Si:Bi photoconductors with individual metal oxide semiconductor field effect transistor preamplifiers operating at 4 K. The system uses a liquid helium-cooled slit, order-sorter filter, collimator mirror, grating, and camera mirror arranged in a Czerny-Turner configuration with a cold stop added between the collimator mirror and the grating. The distances between components are chosen so that the collimator mirror images the secondary mirror of the telescope onto the cold stop, thus providing a very effective baffle. Scattered radiation is effectively reduced by using liquid helium-cooled, black baffles to divide the spectrometer into three separate compartments. The system noise-equivalent flux density, when used on the 152 cm telescope from 8 to 13 microns with a resolving power of 50, is 4.4 x 10 to the minus 17th power W/sq cm micron square root of Hz. The main applications are for measuring continuum radiation levels and solid state emission and absorption features in regions of star and planet formation.
A number of Fabry-Perot (FP) coating designs have been developed specifically for IR astronomy. These have been optimized for uniform reflectance over five contiguous spectral ranges of particular astronomical interest between 1 and 5 microns. Wavelength coverage in individual designs is given by (maximum wavelength/minimum wavelength) greater than 1.4, over which reflective finesse is maintained near 35. Consideration has been made for the peculiar requirements of FP coatings. Visual alignment and testing of the FP has been made convenient by bringing the reflective finesse of the coating at 632.8 nm to the same value as the main IR reflection band. For example, a calcium fluoride FP can be aligned and tested at 632.8-nm He-Ne laser line, with the assurance of a corresponding finesse and spectral resolving power over its IR (3.6-5.1-micron) range. In addition, the FP can be used for IR spectroscopy while being simultaneously monitored and/or actively controlled at the laser wavelength. The potential for the coating itself to degrade the effective surface flatness of the FP through either mechanical stress or thickness nonuniformities is minimized by reducing to a minimum the number and thickness of coating layers. Several of these coatings have been fabricated and are actively in use at a number of observatories.
A liquid helium-cooled, 24 detector grating spectrometer was developed and used for low resolution astronomical observations in the 5 to 14 micron spectral range. The instrument operated on the 91 cm Kuiper Airborne Observatory, the 3 m IRTF (Mauna Kea), the 3 m Shane telescope (Lick Observatory), and the 152 cm NASA and University of Arizona telescope. The detectors are discrete Si:Bi photoconductors with individual metal oxide semiconductor field effect transistor preamplifiers operating at 4 K. The system uses a liquid helium-cooled slit, order-sorter filter, collimator mirror, grating, and camera mirror arranged in a Czerny-Turner configuration with a cold stop added between the collimator mirror and the grating. The distances between components are chosen so that the collimator mirror images the secondary mirror of the telescope onto the cold stop, thus providing a very effective baffle. Scattered radiation is effectively reduced by using liquid helium-cooled, black baffles to divide the spectrometer into three separate compartments. The system noise-equivalent flux density, when used on the 152 cm telescope from 8 to 13 microns with a resolving power of 50, is 4.4 x 10 to the minus 17th power W/sq cm micron square root of Hz. The main applications are for measuring continuum radiation levels and solid state emission and absorption features in regions of star and planet formation.
The CO2 laser heterodyne spectrometer was used at the 3-m IRTF on Mauna Kea to make measurements of Mars during the 1984 opposition. Analysis of the observations of the mesospheric non-thermal emission demonstrated the existence of a warming of the Mars polar mesosphere, similar to the seasonal effects which are well known to occur at the Earth's mesopause. A search for CO2 and NH3 on Comet Halley was done with the new Kitt Peak system as well as with the IRTF heterodyne system. A Lamb-dip absorption cell was designed and constructed. Its use will allow extreme frequency stabilization of the laser local oscillator, which will greatly facilitate measurements of winds and dynamical phenomena. The Lamb-dip cell was used at Kitt Peak to study zonal and meridional winds in the atmosphere of Venus. Water vapor was detected in Comet Halley using Fourier transform spectrometer. The 2.65 micrometer upsilon sub 3 band was seen in emission, confirming non-thermal-equilibrium excitation models for comets. A study was made of the variability of Jovian ethane emission. The average volume mixing ratio of ethane in the Jovian stratosphere was found to be 3x10 to the -6 power, with the greatest variability seen in the auroral regions.
Requirements for background-limited (BLIP) detectors are discussed in terms of number of photons falling on each pixel, dark current, high detective quantum efficiencies, large numbers of pixels, and array size.
An account is given of fabrication methods and low temperature figure tests for CFRP sandwich panels, in order to ascertain their applicability to ultralightweight 3-m aperture primary mirrors for balloon-borne sub-mm and far-IF telescopes that must maintain a 1-2 micron rms surface figure accuracy at -40 to -50 C. Optical figure measurements on the first two of a series of four 0.5-m test panels, replicated to a spherical surface, show a radius-of-curvature change and astigmatism down to -60 C; this approximately follows the composite's theoretical predictions and implies that material and process control is excellent, so that the large scale changes observed can be compensated for.
Basic improvements in the technology of low noise read-out systems for low background detectors were demonstrated. Using discrete JFET integrating amplifiers at their optimum temperature of 55 K, read noise less than 7.5 electrons in 128 seconds of integration was obtained. Two models of single channel integrators are now available, the JF-77 for use between 50 and 80 K and the JF-4 for lower temperatures. A 1 x 15 linear array of complete integrators on a single integrated circuit was developed and will be made available in the near future. The successful operation of a superconducting stepper motor was demonstrated. The motor shows a three fold increase in torque over conventional motors operating at room temperature. The success of the motor stems from the use of superconducting coils in conjunction with developments in bearings for cryogenic use, rare-earth rotors, and motor cooling techniques. The current state of development will allow the rapid development of motors optimized for specific applications. An electronic switch capable of resetting cooled JFET integrating amplifiers was developed. The JFET integrating amplifiers that use this switch have demonstrated read noise of less than 10 electrons. The JFET reset device exhibits an extremely high open impedance and low leakage current. Capacitance is sufficiently low so as not to impair amplifier sensitivity. The effects of transient switching charges are minimized by a compensation technique and variable transient current problems inherent to devices of this type are overcome by external circuity.
SOFIA, a proposed 3-meter class telescope in a Boeing 747 aircraft, would have the ability to make astronomical observations over a wavelength range from 0.3 microns to 1.6mm. Relative to the KAO (Kuiper Airborne Observatory) the larger telescope on SOFIA would provide a factor of 10 improvement in sensitivity for compact sources and a factor of 3 improvement in (diffraction-limited) angular resolution at wavelengths beyond 30 microns. In addition, SOFIA will retain the major features of the KAO which have made the airborne astronomy program so successful. Among these are continuous in-flight access to focal plane instruments while flying at or above 41,000 ft altitude; pointing stability of 0.2 arcseconds; and mobility and scheduling flexibility to accommodate targets of opportunity such as comets, eclipses, occultations, and novae.
SOFIA, an airborne observatory intended to be carried aboard a Boeing 747 high performance aircraft, is described. The observatory is predicted to provide a threefold greater aperture than that of the Kuiper telescope. The Boeing aircraft will carry the 2.5 diameter telescope and its observers to altitudes of 14,000 and above where the atmosphere is very nearly transparent at all wavelengths. Various aspects and specific missions of the SOFIA project, a cooperative venture of the U.S. and Germany, are described.
SOFIA is described as it was originally (May 1988) for the Space and Earth Sciences Advisory Committee (SESAC). The format and questions were provided by SESAC as a standard for judging the merit of potential U.S. space science projects. This version deletes Section IIF, which addressed development costs of the SOFIA facility. SOFIA's unique astronomical potential is described and it is shown how it complements and supports existing and planned facilities.
Explore the source record for details and available documents.
The SOFIA Aircraft System (AS) Phase 1 Study was a broad-based study which addressed itself to satisfying technical and programmatic requirements by drawing from existing technology and applying cost-efficient commercial approaches to the aircraft modification. In this SOFIA AS Phase 2 Study, five critical areas of the aircraft were selected for more detailed investigation: forward pressure bulkhead, aft bulkhead, 'free' shell to bulkhead interface, shell cut-out to bulkhead interface, and flooring. The in-depth investigation of these areas upon a finite element model (FEM), with a fine grid model in areas of particular interest, is discussed. The FEM code used is called 'STRAP' and was developed by the engineering firm, Rasmussen and Associates. STRAP is NASTRAN compatible to within 1%. The loads applied to the model were approximated from known 747 envelope conditions. The areas of investigation, and a section through the fuselage is shown. The thrust of this investigation was to develop the design concepts conceived under phase 1 to the point where detailed design could be undertaken with a high level of confidence.
Airborne and ground-based IR telescopes have oscillating secondary mirrors to permit subtraction of background emission from the sky and telescope. These chopping mirrors are synchronized to a clock which may originate in the data acquisition system. For laboratory testing of detecting instruments with such data systems, externally synchronized chopped IR sources are required. We describe a laboratory chopper in which a synchronous motor is driven by 2-phase sinusoidal currents in sync with an external clock at frequencies from 5 to 50 Hz. This design is used with the KAO's facility sources, the Chopped Hotplate and the Portable Chopped Light Source (PCLS).