Search NASA⌕ Search

SEARCH · Search NASA

Results for “Infrared techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Anomalous Auger Recombination in PbSe

Using first-principles approaches we find that the Auger recombination in PbSe is anomalous in three distinct ways. First, the direct Auger coefficient is 4 orders of magnitude lower than that of other semiconductors with similar band gaps, a result that can be attributed to the lack of involvement of a heavy-hole band. Second, phonon-assisted indirect Auger recombination prevails, contrary to the common belief that direct Auger is dominant in narrow-gap semiconductors. Third, an unexpectedly weak temperature dependence of the Auger coefficient is observed, which we can now attribute to the indirect nature of the Auger process. The widely accepted explanation of this behavior in terms of an unusual temperature dependence of the band gap is only a secondary effect. Furthermore, our results elucidate the mechanisms underlying the anomalous Auger recombination in IV-VI semiconductors in general, which is critical for understanding and engineering carrier transport.

36 MATERIALS SCIENCE↗

EuCd 2 ⁢As 2 : A Magnetic Semiconductor

EuCd 2 ⁢As 2 is now widely accepted as a topological semimetal in which a Weyl phase is induced by an external magnetic field. Here, we challenge this view through firm experimental evidence using a combination of electronic transport, optical spectroscopy, and excited-state photoemission spectroscopy. We show that the EuCd 2 ⁢As 2 is in fact a semiconductor with a gap of 0.77 eV. We show that the externally applied magnetic field has a profound impact on the electronic band structure of this system. This is manifested by a huge decrease of the observed band gap, as large as 125 meV at 2 T, and, consequently, by a giant redshift of the interband absorption edge. However, the semiconductor nature of the material remains preserved. EuCd 2 ⁢As 2 is therefore a magnetic semiconductor rather than a Dirac or Weyl semimetal, as suggested by ab initio computations carried out within the local spin-density approximation.

36 MATERIALS SCIENCE↗

GeMini: The Next-Generation Mechanically-Cooled Germanium Spectrometer

The next-generation mechanically-cooled germanium spectrometer has been developed. GeMini (MINIature GErmanium spectrometer) has been designed to bring high-resolution gamma-ray spectroscopy to a range of demanding field environments. Intended applications include short-notice inspections, border patrol, port monitoring and emergency response, where positive nuclide identification of radioactive materials is required but power and liquid cryogen are not easily available. GeMini weighs 2.75 kg for the basic instrument and 4.5 kg for the full instrument including user interface and ruggedized hermetic packaging. It is very low power allowing it to operate for 10 hours on a single set of rechargeable batteries. This instrument employs technology adapted from the gamma-ray spectrometer currently flying on NASA's Mercury MESSENGER spacecraft. Specifically, infrared shielding techniques allow for a vast reduction of thermal load. This in turn allows for a smaller, lighter-weight design, well-suited for a hand-held instrument. Three working prototypes have been built and tested in the lab. The measured energy resolution is 3 keV fwhm at 662 keV gamma-rays. This paper will focus on the design and performance of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reliability Testing the Die-Attach of CPV Cell Assemblies

Results and progress are reported for a course of work to establish an efficient reliability test for the die-attach of CPV cell assemblies. Test vehicle design consists of a ~1 cm2 multijunction cell attached to a substrate via several processes. A thermal cycling sequence is developed in a test-to-failure protocol. Methods of detecting a failed or failing joint are prerequisite for this work; therefore both in-situ and non-destructive methods, including infrared imaging techniques, are being explored as a method to quickly detect non-ideal or failing bonds.

14 SOLAR ENERGY↗

Spectroscopic Investigation of Catalyst Inks and Thin Films Toward the Development of Ionomer Quality Control

As the production of polymer electrolyte fuel cells expands, novel quality control methods must be invented or adapted in order to support expected rates of production. Ensuring the quality of deposited catalyst layers is an essential step in the fuel cell manufacturing process, as the efficiency of a fuel cell is reliant on the catalyst layer being uniform at both the target platinum loading and the target ionomer content. Implementing a quality control method that is sensitive to these aspects is imperative, as wasting precious metals and other catalyst materials is expensive, and represents a potential barrier to entry into the field for manufacturers experimenting with novel deposition processes. In this work, we analyzed catalyst inks to determine if their ionomer content could be quantized spectroscopically. Attenuated total reflection (ATR) Fourier transform infrared spectroscopic technique was investigated producing a signal proportional to the ionomer content. ATR spectroscopy was able to quantitatively differentiate samples in which the ionomer to carbon mass ratio (I/C) varied between 0.9 and 3.0. The I/C ratio was correlated to the measured ATR signal near the CF 2 vibrational bands located between 1100 cm −1 and 1400 cm −1 . The experimental results obtained constitute a step toward the development of novel quality control methodologies for catalyst inks utilized by the fuel cell industry.

30 DIRECT ENERGY CONVERSION↗

Reaction of Formic Acid over Amorphous Manganese Oxide Catalytic Systems: An In Situ Study

The interaction of formic acid with amorphous manganese oxide (AMO) is investigated using in situ photoelectron and infrared spectroscopy techniques. Soft X-ray photoelectron spectroscopy (sXPS) and in situ FTIR illustrate two possible modes of formate bound species at the AMO surface. Two peaks in the IR region from 1340-1390 cm{sup -1} are indicative of formate species bound to the surface in a bidentate configuration. However, a 224 cm{sup -1} band gap between v{sub s}OCO and v{sub as}OCO suggests formate is bound in a bridging configuration. Temperature-programmed desorption studies confirm the formate bound species desorbs as carbon dioxide from the surface at multiple binding sites. At temperatures above 700 K, the presence of K{sup +} {hor_ellipsis} OC complex suggests the bound species interacts at vacant sites related to framework oxygen and cation mobility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fabrication of cubic micron-scale 3D metamaterial resonators.

We present a new fabrication technique called Membrane Projection Lithography for the production of three-dimensional metamaterials at infrared wavelengths. Using this technique, multilayer infrared metamaterials that include both in-plane and out-of-plane resonators can be fabricated.

36 MATERIALS SCIENCE↗

Synchrotron Infrared Spectroscopy with Multivariate Spectral Analyses Potentially Facilitates the Classification of Inherent Structures of Feed-Type of Sorghum

The objective of this study was to investigate the inherent structural-chemical features of Chinese feed-type sorghum seed using synchrotron-radiation Fourier transform infrared microspectroscopy (SRFTIRM) with two multivariate molecular spectral analysis techniques: Agglomerative Hierarchical cluster (AHCA) and principal component analyses (PCA). The results show that by application of these two multivariate techniques with the infrared spectroscopy of the SRFTIRM, it makes possible to discriminate and classify the inherent molecular structural features among the different layers of sorghum with a great efficiency. With the SRFTIRM, images of the molecular chemistry of sorghum could be generated at an ultra-spatial resolution. The features of nutrient matrix and nutrient make-up and interactions could be revealed.

36 MATERIALS SCIENCE↗

Fabrication techniques for 3D metamaterials in the mid-infrared.

The authors have developed two versions of a flexible fabrication technique known as membrane projection lithography that can produce nearly arbitrary patterns in '212 D' and fully three-dimensional (3D) structures. The authors have applied this new technique to the fabrication of split ring resonator-based metamaterials in the midinfrared. The technique utilizes electron beam lithography for resolution, pattern design flexibility, and alignment. The resulting structures are nearly three orders of magnitude smaller than equivalent microwave structures that were first used to demonstrate a negative index material. The fully 3D structures are highly isotropic and exhibit both electrically and magnetically excited resonances for incident transverse electromagnetic waves.

36 MATERIALS SCIENCE↗

Interferometric measurement of melt depth in silicon using femtosecond infrared Cr:forsterite laser

Interferometric microscopy technique combined with high power infrared Cr:forsterite laser system was applied to investigate femtosecond laser induced melting of silicon. Optically polished wafer of single crystalline silicon of 400 {mu}m thickness was irradiated with 100 fs pump pulses at second harmonic wavelength of 620 nm. We used infrared probe pulses at main wavelength of 1240 nm, whose photon energy was less than the band gap width E{sub g} = 1.12eV of silicon, and the penetration depth of probe essentially exceeded the sample thickness. Unlike many previous experiments with Ti:sapphire lasers it allowed us to probe the heated area from the rear side of the sample and obtain the data on melt depth after laser irradiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

IGRINS RV: A Precision Radial Velocity Pipeline for IGRINS Using Modified Forward Modeling in the Near-infrared

Application of the radial velocity (RV) technique in the near-infrared is valuable because of the diminished impact of stellar activity at longer wavelengths, making it particularly advantageous for the study of late-type stars but also for solar-type objects. In this paper, we present the IGRINS RV open-source python pipeline for computing infrared RV measurements from reduced spectra taken with IGRINS, an R ≡ λ/Δλ ∼ 45,000 spectrograph with simultaneous coverage of the H band (1.49–1.80 μm) and K band (1.96–2.46 μm). Using a modified forward-modeling technique, we construct high-resolution telluric templates from A0 standard observations on a nightly basis to provide a source of common-path wavelength calibration while mitigating the need to mask or correct for telluric absorption. Telluric standard observations are also used to model the variations in instrumental resolution across the detector, including a yearlong period when the K band was defocused. Without any additional instrument hardware, such as a gas cell or laser frequency comb, we are able to achieve precisions of 26.8 m s{sup −1} in the K band and 31.1 m s{sup −1} in the H band for narrow-line hosts. These precisions are empirically determined by a monitoring campaign of two RV standard stars, as well as the successful retrieval of planet-induced RV signals for both HD 189733 and τ Boo A; furthermore, our results affirm the presence of the Rossiter–McLaughlin effect for HD 189733. The IGRINS RV pipeline extends another important science capability to IGRINS, with publicly available software designed for widespread use.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

IACMI Project 4.2: Thermoplastic Composite Development for Wind Turbine Blades

(Section 5.1) Composites made from Arkema’s Elium® thermoplastic resin and Johns Manville fiberglass were researched during this project for applications in wind blade manufacturing. A techno-economic model was developed to model this wind blade manufacturing process using these materials in place of traditional composites made with thermoset resin. This model was based on manufacturing a 61.5-meter wind blade, which showed a 4.7% reduction in wind blade cost as compared traditional thermoset materials. These cost savings were not from the thermoplastic material costing less than traditional thermoset materials, but rather from decreased capital costs, faster cycle times and reduced energy requirements and labor costs. (Section 5.2) An infusion and curing model was developed for thermoplastic composite wind blades using PAM-RTM. The primary goal was to demonstrate the infusion simulation for the Elium® resin system on a 13-meter wind blade. Additionally, the exotherm temperature was predicted and compared to measurements, which showed model results within 10% of actual measurements. (Section 5.3) Composite laminate panels and composite sandwich panels with a balsa core were produced; specimens were cut and characterized. Similar composite specimens were made with Elium® thermoplastic resin and Hexion thermoset epoxy (RIMR135/RIMH1366) to enable comparisons between these resin systems. The static test methods included: tensile, compression, in-plane shear, interlaminar shear, flexural, sandwich core shear flexure, and single cantilever beam tests for sandwich beams. Fatigue testing at room temperature was completed to composite laminate panels at a stress ratio of R=0.1 and R=10. In addition, fatigue testing to laminate panels was completed at -30°C, and at room temperature after conditioning specimens at 70°C and 90% relative humidity. Overall, mechanical test results from Elium® composites are similar to epoxy composites. (Section 5.4) Elium composite panels were produced with intentional defects such as voids and nonwetting of fibers to begin to understand performance sensitivity to defects. A thermal digital image correlation (TDIC) method provides high spatial resolution strain field at elevated temperatures and can be used to identify defective regions within composite panels. Flexural modulus differences of 21% were seen between defect and non-defect panels. Other Elium® composite panels were forced to be defective by boiling the resin after infusion, which created voids throughout the composite laminate. X-ray computed tomography scanning was used to view the internal structure of the defect panels. Defect panels had a significant reduction in fatigue life as compared to baseline panels produced without intentional defects. (Section 5.5) Lap shear specimens were fabricated to compare the lap shear strength of an off-the-shelf adhesive (Plexus MA590) and two new adhesives developed by Arkema (Bostik SAF30 90 and Bostik SAF30 120). ISO standard 4587:2003 was used to standardize the testing method and sample fabrication. Lap shear specimens were made at 1mm, 3mm, and 10mm thicknesses. The Bostik adhesive lap shear test results were similar to Plexus for all thicknesses. (Section 5.6) Fiber-reinforced polymer (FRP) composites are typically used in high-performance applications (e.g., aerospace), and their expansion into high-volume industries (e.g. consumer automotive and wind turbine blade manufacturer or similar) is hindered by their cost and a lack of efficient manufacturing techniques. Monitoring the curing process of these composites during manufacturing can improve the efficiency of the process, and therefore reduce the manufacturing cost. Cure monitoring techniques were developed that use probabilistic estimation methods and surface temperature measurements made using infrared cameras. These techniques enable real-time monitoring of the infusion process to locate manufacturing flaws, and they can, potentially, estimate residual stresses in the part. Their commercialization will help facilitate expansion of FRP composites in high-volume industries. (Section 5.7) A 13-meter composite wind blade was produced with Elium® resin and Johns Manville fiberglass; this blade was made with VARTM processing similar to how megawatt-scale wind blades are currently manufactured, but no post-mold heating was used for this thermoplastic composite blade. The wind blade underwent full-scale validation for static loading (4-different load orientations) and flapwise fatigue loading to simulate 20-years of operational loads. The thermoplastic composite wind blade withstood the loading without any noted issues and performed similar to results from a previous full-scale validation to an equivalent epoxy composite wind blade produced with the same blade molds. (Section 5.8) A study was conducted to determine the feasibility of recycling composite wind turbine blade components fabricated with glass fiber reinforced Elium® thermoplastic resin. Dissolution, which is a process unique to thermoplastic matrices, allows recovery of both the polymer matrix and full-length glass fibers, while maintaining their stiffness and strength throughout the recovery process. The economics of recycling is favorable if 50% of the glass fiber is recovered and resold for a process of $\$$ 0.28/kg, and 90% of the resin is recovered and resold at a price of $\$$ 2.50/kg.(Section 10) Recommendations are outlined for commercializing thermoplastic resin for composite wind blade production, in addition to recommended areas for future research.

17 WIND ENERGY↗

A Comparative Observational Study of YSO Classification in Four Small Star-forming H ii Regions

We have developed a new young stellar object (YSO) identification and classification technique using mid-infrared Wide-field Infrared Survey Explorer (WISE) data. We compare this new technique with previous WISE YSO detection and classification methods that used either infrared colors or spectral energy distribution slopes. In this study, we also use the new technique to detect and examine the YSO population associated with four small H ii regions: KR 7, KR 81, KR 120, and KR 140. The relatively simple structure of these regions allows us to effectively use both spatial and temporal constraints to identify YSOs that are potential products of triggered star formation. We are also able to identify regions of active star formation around these H ii regions that are clearly not influenced by the H ii region expansion, and thus demonstrate that star formation is on-going on megayear timescales in some of these molecular clouds.

79 ASTRONOMY AND ASTROPHYSICS↗

MID-INFRARED PHOTOMETRIC ANALYSIS OF MAIN BELT ASTEROIDS: A TECHNIQUE FOR COLOR-COLOR DIFFERENTIATION FROM BACKGROUND ASTROPHYSICAL SOURCES

The Spitzer Space Telescope routinely detects asteroids in astrophysical observations near the ecliptic plane. For the galactic or extragalactic astronomer, these solar system bodies can introduce appreciable uncertainty into the source identification process. We discuss an infrared color discrimination tool that may be used to distinguish between solar system objects and extrasolar sources. We employ four Spitzer Legacy data sets, the First Look Survey-Ecliptic Plane Component (FLS-EPC), SCOSMOS, SWIRE, and GOODS. We use the Standard Thermal Model to derive FLS-EPC main belt asteroid (MBA) diameters of 1-4 km for the numbered asteroids in our sample and note that several of our solar system sources may have fainter absolute magnitude values than previously thought. A number of the MBAs are detected at flux densities as low as a few tens of {mu}Jy at 3.6 {mu}m. As the FLS-EPC provides the only 3.6-24.0 {mu}m observations of individual asteroids to date, we are able to use this data set to carry out a detailed study of asteroid color in comparison to astrophysical sources observed by SCOSMOS, SWIRE, and GOODS. Both SCOSMOS and SWIRE have identified a significant number of asteroids in their data, and we investigate the effectiveness of using relative color to distinguish between asteroids and background objects. We find a notable difference in color in the IRAC 3.6-8.0 mm and MIPS 24 {mu}m bands between the majority of MBAs, stars, galaxies, and active galactic nuclei, though this variation is less significant when comparing fluxes in individual bands. We find median colors for the FLS-EPC asteroids to be [F(5.8/3.6), F(8.0/4.5), F(24/8)] = (4.9 {+-} 1.8, 8.9 {+-} 7.4, 6.4 {+-} 2.3). Finally, we consider the utility of this technique for other mid-infrared observations that are sensitive to near-Earth objects, MBAs, and trans-Neptunian objects. We consider the potential of using color to differentiate between solar system and background sources for several space-based observatories, including Warm Spitzer, Herschel, and WISE.

79 ASTRONOMY AND ASTROPHYSICS↗