Search NASA⌕ Search

SEARCH · Search NASA

Results for “Infrastructure transformation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Empirically-calibrated H100 node power models for accurate AI training energy estimation

Accurately quantifying the energy use of artificial intelligence (AI) training is critical for infrastructure planning, carbon accounting, and sustainable data center operation, but few studies have directly measured the power consumption of production workloads on contemporary hardware. By combining empirical measurements from Brookhaven National Laboratory during AI training on 8-graphics-processing-unit H100 systems with open-source benchmarking data, we develop statistical models relating computational intensity to node-level power consumption. We measure the gap between manufacturer-rated thermal design power (TDP) and actual power demand during AI training. Our analysis reveals that even computationally intensive workloads operate at only 76% of the 10.2 kW TDP rating. Our architecture-specific model, calibrated to floating-point operations, predicts energy consumption with 11.4% mean absolute percentage error, significantly outperforming TDP-based approaches (27%–37% error). We identified distinct power signatures between transformer and convolutional neural network architectures, with transformers showing characteristic fluctuations that may impact grid stability. These results provide a measurement-grounded basis for improving AI training energy estimates, enabling more reliable infrastructure sizing, cost projections, and environmental impact assessments.

Newkirk, Alex C↗

Unprecedented Analysis of LA’s Clean Energy Transformation

Jurisdictions like the City of Los Angeles are boldly establishing ambitious energy objectives—and NREL can be a key partner in informing these transitions.The City of Los Angeles is one of several U.S. local governments setting monumental, measurable goals to transform their energy economies. At the direction of its City Council, LA has embarked on a plan to modernize its electricity system infrastructure—aiming for a 100% renewable energy supply by 2045, along with aggressive electrification targets for buildings and vehicles.

LA100↗

Serial communication tapping and transmission to routable networks

Apparatuses and methods for tapping serial communications and transforming the serial data into a format appropriate for routable networks are significant for purposes of security and troubleshooting, especially in critical infrastructure networks. Communication taps should be completely passive such that any failure would not interrupt the serial communications. Furthermore, automatic determination of unspecified serial protocol frames allow general implementation across various networks, or across devices within a single network, without the need to customize for each implementation.

Edgar, Thomas W.↗

Electrolytically Assisted Surface Decontamination (EASD{sup TM}) for POCO Operations - 20282

NNL in collaboration with C-Tech Innovation Ltd and Sellafield Ltd has been exploring innovative technologies to enable a significant reduction of radiological hazards within facilities during the Post Operational Clean Out (POCO) phase of a nuclear plant's life cycle. Reducing the hazard by effectively decontaminating plants in-situ during POCO delivers huge cost reductions for future decommissioning operations. These cost reduction benefits are realized by reducing the number and complexity of remote operations as well as lowering the long-term waste disposal costs. Whilst chemical decontamination can achieve the desired level of decontamination, applying aggressive chemical reagents is hazardous, potentially difficult to control and requires there to be complimentary effluent treatment and waste routes. This work has aimed to develop flexible and controllable decontamination processes which could be operated without the additional complexity and issues associated with chemical decontamination. The processes needed to be relatively fast and effective to minimize the time operators would spend in an active area. In addition, there was a driver to produce decontamination methodologies which generated a secondary waste compatible with current routes and which takes advantage of current waste capacity. The strategy therefore was to come up with a solution that works with, rather than against, the science and engineering behind process plants at Sellafield. Electrolytically Assisted Surface Decontamination (EASD{sup TM}) is an innovative electrochemical decontamination process (developed by NNL and C-Tech Innovation Ltd) that can remove activity from contaminated metal in very short time periods. Application of the patented electric waveform to the surface when treating contaminated metal with nitric acid has been shown to significantly enhance the decontamination performance. When compared to proposed baseline washout procedures at Sellafield, the only change to the process is the applied electrical waveform which is temporary and controllable. The current causes dissolution of the metal surface being decontaminated which leads to activity transferring from the plant item into the nitric acid effluent stream. This innovation has the potential to transform the POCO process and allow a nitric acid based washout approach to deliver POCO quickly and cost effectively within the existing infrastructure. Several devices have now been designed that incorporate this EASD{sup TM} technology and enable the decontamination process to be applied to a range items commonly identified as being contaminated during nuclear decommissioning programmes such as pipework, tanks and hotspots of walls/floors. Inactive and active laboratory-scale testing has been completed using both simulated and 'real-life' contaminated (low level waste) metallic items retrieved from different nuclear sites. Active trials demonstrated that contaminated items could be treated to free release levels within minutes. Engineering scale tests are currently being performed, with guidance from Sellafield's system engineers and plant managers, to provide the necessary re-assurance the designed devices could be successfully deployed in an on-plant scenario. The final stage of this development work is to carry out an active demonstration of the decontamination technology on Thorp at Sellafield. This paper aims to highlight progress made to date with the EASD{sup TM} technology and, more specifically, the development of an in-situ decontamination device for deployment within radioactive pipework. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Serial communication tapping and transmission to routable networks

Apparatuses and methods for tapping serial communications and transforming the serial data into a format appropriate for routable networks are significant for purposes of security and troubleshooting, especially in critical infrastructure networks. Communication taps should be completely passive such that any failure would not interrupt the serial communications. Furthermore, automatic determination of unspecified serial protocol frames allow general implementation across various networks, or across devices within a single network, without the need to customize for each implementation.

Edgar, Thomas W.↗

Leveraging generative AI for urban digital twins: a scoping review on the autonomous generation of urban data, scenarios, designs, and 3D city models for smart city advancement

The digital transformation of modern cities by integrating advanced information, communication, and computing technologies has marked the epoch of data-driven smart city applications for efficient and sustainable urban management. Despite their effectiveness, these applications often rely on massive amounts of high-dimensional and multi-domain data for monitoring and characterizing different urban sub-systems, presenting challenges in application areas that are limited by data quality and availability, as well as costly efforts for generating urban scenarios and design alternatives. As an emerging research area in deep learning, Generative Artificial Intelligence (GenAI) models have demonstrated their unique values in content generation. This paper aims to explore the innovative integration of GenAI techniques and urban digital twins to address challenges in the planning and management of built environments with focuses on various urban sub-systems, such as transportation, energy, water, and building and infrastructure. The survey starts with the introduction of cutting-edge generative AI models, such as the Generative Adversarial Networks (GAN), Variational Autoencoders (VAEs), Generative Pre-trained Transformer (GPT), followed by a scoping review of the existing urban science applications that leverage the intelligent and autonomous capability of these techniques to facilitate the research, operations, and management of critical urban subsystems, as well as the holistic planning and design of the built environment. Based on the review, we discuss potential opportunities and technical strategies that integrate GenAI models into the next-generation urban digital twins for more intelligent, scalable, and automated smart city development and management.

3D city modeling↗

A Unified Design Theory for Multi-Port Polyphase Transformers Enabling Scalable Power-Multiplexed EV Fleet Charging Systems

This paper presents a unified analytical design theory for multi-port polyphase transformers, targeting scalable and isolated high-power Electric Vehicle (EV) fleet charging systems with power multiplexing capability. As fleet electrification accelerates, conventional one-to-one charger architectures face significant challenges in infrastructure cost, peak power demand, and low utilization of installed power electronics. Power-multiplexed charging architectures, which dynamically distribute power from a shared pool of converter modules across multiple vehicles, have emerged as a promising solution. However, such architectures require scalable, isolated multi-port power interfaces capable of routing energy among multiple inputs and outputs, whose design remains complex and dependent on iterative modeling. To address this gap, the proposed theory provides closed-form expressions for self-inductance, leakage inductance, and mutual coupling terms for arbitrary multi-phase, multi-port transformer structures. The formulation enables direct synthesis of isolated multi-input and multi-output resonant converter systems without reliance on geometry-specific finite-element analysis or extensive parameter extraction. This capability is particularly critical for power-multiplexed systems, where modular converter structures must interface with multiple vehicles while maintaining galvanic isolation and flexible power allocation. The effectiveness of the proposed framework is demonstrated through the design of a 360 kW multi-phase system operating over a 700–900 VDC input and 400–1250 VDC output range. PLECS simulation results confirm accurate prediction of system behavior and validate the applicability of the approach to multi-port, power-multiplexed charging scenarios. The proposed method significantly reduces design complexity while enabling scalable, cost-effective, and fully utilized EV fleet charging infrastructure.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Improving Resiliency in Planning MW-Scale Medium and Heavy Duty EV Charging Stations Considering TSCOTS Optimization

Electrification of heavy-duty (HD) vehicles marks an important milestone and technical challenge in the electric vehicle (EV) industry and the public grid. However, implementing EV charging at this scale will necessitate that traditional truck stops be updated with EV charging infrastructure that could represent 10's of MW in electricity consumption. Furthermore, as the transportation sector is represented as critical infrastructure, supporting resiliency considerations in EV charging infrastructure will be critical. This paper proposes an optimization-based approach for optimally designing a MW-scale microgrid charging network. This approach transforms conventional designed truck stops into a reliable HDEV charging stations capable of overnight slow charging and 30-minute to 1 hour fast charging. Using a mixed-integer linear program formulation blending capacity planning and reliability constraints, an optimal network configuration can be solved for a proposed EV charging station that includes photovoltaic and battery energy storage capabilities.

Ponce, Moises [University of Tennessee, Knoxville ↗

Strengthening the Security of Operational Technology: Understanding Contemporary Bill of Materials

The evolution of cyber-physical infrastructure has made its security more challenging. The last few years have witnessed a convergence of hardware and software segments in various domains, including operational technology (OT) which is responsible for carrying out critical tasks such as monitoring and controlling power grids, nuclear plants, transportation, and emergency services. Both hardware and software encapsulate numerous open source and proprietary subcomponents, making it crucial for end-users to understand the composition of the products they are using. For example, wind turbines incorporate thousands of lines of code (software) used for the turbine's design, planning, operation, and analytics in addition to the numerous hardware subcomponents that construct it. Due to the highly complex nature of software and hardware, knowledge of the components and subcomponents is required to mitigate cyber vulnerabilities and defend against cyberattacks. There has also been a transformation from a traditional linear supply chain into a global, dynamic, diverse, and interconnected system. The digitization of the supply chain makes it easier to find and exploit vulnerabilities. Critical infrastructures (e.g., power grids, oil, natural gas, water, and wastewater) rely on OT to function, and if the OT is compromised, equipment damage and potential interruption of services could result. A significant security measure to protect OT systems from disruption is to develop a supply chain bill of materials (BoM) corresponding to the software and hardware used in OT, along with attestations amongst vendors and asset owners. A supply chain BoM is a proactive way to understand the inherent vulnerabilities in the system and mitigate them in advance of being exploited. BoMs bolster the trust placed in the digital infrastructure and enhance software supply chain security by sustaining the management of component obsolescence and compliance, along with the seclusion of unsafe segments of a specific product. Adopting BoM tools is becoming increasingly important across various government sectors, as evidenced by the recent U.S. executive order on cybersecurity (NIST 2021). This paper aims to classify BoMs based on structure, functionality, component type, and architecture. The work also discusses case studies to further highlight the benefits of BoMs. In addition, it identifies missing pieces in existing BoM implementations so that future research may identify bounds on where it could expect to make improvements and directly enable researchers to identify promising areas for exploration. Further, the authors provide valuable recommendations to tool developers, researchers, and standardizing organizations (policymakers), additionally benefitting critical infrastructure owners and government executives. This aids in paving a path for future work, thereby, providing suggestions to determine a tool for consumers that best suit their needs.

97 MATHEMATICS AND COMPUTING↗

A Step-by-Step Protocol from METASPACE to Biological Interpretation

Mass spectrometry imaging (MSI) represents an exceptional tool for exploring complex biological systems spatially at the molecular level. However, due to its multidimensional nature and large-scale data output, it presents considerable challenges when it comes to extracting meaningful biological insights. Recent advancements, such as the METASPACE platform, have enabled researchers to efficiently process, annotate, and interpret MSI datasets by leveraging machine learning and cloud-based infrastructure. In this tutorial, we present a detailed and user-friendly R-pipeline designed to help METASPACE users navigate untargeted metabolomic annotations and transform them into practical insights about their biological systems. By combining METASPACE annotations with rapid R-based screening, this workflow not only streamlined the analytical process but also enhanced the understanding of spatial molecular distribution, especially for complex systems. Here, this easy-to-follow approach has the potential for applications in diagnostics, drug discovery, environmental and ecological processes, and more. We envision this pipeline to be particularly useful for newcomers to the field of MSI and

Moreno Pedraza, Abigail↗

Formally Verified ZTA Requirements for OT/ICS Environments with Isabelle/HOL

The clean energy transformation includes the integration of distributed energy resources with the power grid, which has led to a substantial increase in the complexity of power grids infrastructure and the underlying operational technology environment. Power grids infrastructure represents an operational technology environment that has become a system of systems, integrating heterogeneous devices which are both software-and hardware-intensive; as a result, there are increasing demands to exploit advances in the commodity of software-hardware infrastructures to improve energy systems requirements such as cybersecurity and resilience. In such a setting, system requirements at different levels mix, which leads to vulnerabilities and undesirable outcomes. The use of formal methods to characterize and prove system requirements removes ambiguity, increases automation, and provides high levels of assurance and reliability. In this paper, we contribute a methodology and a framework for the system-level verification of zero trust architecture requirements in operational technology environments. We define a formal specification for the core functionalities of operational technology environments, the corresponding invariants, and security proofs. Of particular note is our modular approach for the formal verification of asynchronous interactions in operational technology environments. The formal specification and the proofs have been mechanized using the interactive theorem proving environment Isabelle/HOL.

formal methods↗

Adhesion of impure ice on surfaces

The undesirable buildup of ice can compromise the operational safety of ships in the Arctic to high-flying airplanes, thereby having a detrimental impact on modern life in cold climates. The obstinately strong adhesion between ice and most functional surfaces makes ice removal an energetically expensive and dangerous affair. Hence, over the past few decades, substantial efforts have been directed toward the development of passive ice-shedding surfaces. Conventionally, such research on ice adhesion has almost always been based on ice solidified from pure water. However, in all practical situations, freezing water has dissolved contaminants; ice adhesion studies of which have remained elusive thus far. Here, in this work, we cast light on the fundamental role played by various impurities (salt, surfactant, and solvent) commonly found in natural water bodies on the adhesion of ice on common structural materials. We elucidate how varying freezing temperature & contaminant concentration can significantly alter the resultant ice adhesion strength making it either super-slippery or fiercely adherent. The entrapment of impurities in ice changes with the rate of freezing and ensuing adhesion strength increases as the cooling temperature decreases. We discuss the possible role played by the in situ generated solute enriched liquid layer and the nanometric water-like disordered ice layer sandwiched between ice and the substrate behind these observations. Our work provides useful insights into the elementary nature of impure water-to-ice transformation and contributes to the knowledge base of various natural phenomena and rational design of a broad spectrum of anti-icing technologies for transportation, infrastructure, and energy systems.

36 MATERIALS SCIENCE↗

Development of an Advanced Integrated Operations Concept for Hybrid Control Rooms

The U.S. Nuclear Industry has an urgent need to reduce the operations and maintenance costs to remain economically competitive in today’s energy market. Measures to improve efficiency in operations will need to leverage technology in a way that safely transforms how plants are operated. This work describes the development of an integrated operations concept that integrates data from existing Instrumentation and Control (I&C) infrastructure, upgraded I&C systems, new sensors, and field technologies such as computer-based procedures to provide operators with centralized, streamlined instructions. The concept was developed to allow for an operator to remotely supervise many plant activities and to dramatically streamline plant operations and maintenance. This report describes the design philosophy, the analysis used to inform design, the implementation in the Human Systems Simulation Laboratory, and illustrates the design concept.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Blueprint for DOE Quantum Supercomputing: Ensuring U.S. Leadership in the Quantum Decade

Quantum computing stands at the threshold of a transformative decade, where the field will evolve from small-scale demonstrations toward practical scientific computing at scale. This Blueprint identifies fault-tolerant quantum computers (FTQCs) as a viable, scalable, and broadly applicable path to achieving “quantum scientific utility,” defined as solving scientifically valuable problems beyond the reach of conventional, classical computers. This capability is expected to show scientific demonstrations in the late 2020s and to mature in the early-to-mid 2030s. This Blueprint outlines a strategy to prepare the U.S. Department of Energy (DOE) for FTQCs and their integration into the U.S. national scientific computing infrastructure. Its purpose is to identify the steps, milestones, and research directions necessary for DOE to enable initial deployment of FTQCs in 2028 as a scientific tool for the nation and mature this capability into the 2030s. DOE has a long history of supporting quantum information science and technology, contributing significantly to research advancements, training a quantum-ready workforce, and providing access to early small-scale quantum hardware. Given recent demonstrations of logical operations on error-corrected logical qubits and the advancement of commercial hardware roadmaps, DOE should begin preparations for large-scale, fault-tolerant quantum computing deployment for DOE science missions. This Blueprint proposes that DOE focus on (1) deploying first-generation scientifically relevant quantum computers with at least 100 logical qubits and performing at least 10,000 to 100,000 hard logical operations in scientifically relevant calculations; (2) developing essential FTQC programming competencies, system software, and facility readiness; and (3) investing in cutting edge focused R&D that fosters breakthroughs in scientific applications, algorithms, and logical architectures needed to accelerate the advent of scientific utility. This effort will position DOE to transition to larger systems: production-scale quantum computers that comprise 1,000 to 10,000 logical qubits, perform 1 to 10 billion hard logical operations, and execute scientifically useful computations at scale. Achieving these goals will require DOE facilities to evolve with urgency to support scientific campaigns that integrate quantum and classical computing resources into efficient workflows, novel software and firmware environments for compiling and routing quantum programs on FTQC machines, and suitable infrastructure for quantum hardware. It will also require further development and optimization of scientific applications from the fields of materials science, quantum chemistry, and high-energy and nuclear physics. The Blueprint calls for transformative R&D and collective action to accelerate the advent of scientific quantum utility and bring it within reach by 2028.

97 MATHEMATICS AND COMPUTING↗

Demonstration and Evaluation of an Advanced Integrated Operations Concept for Hybrid Control Rooms

The U.S. nuclear industry has an urgent need to reduce operations and maintenance costs to remain economically competitive in today’s energy market. Measures to improve efficiency in operations will need to leverage technology in a way that safely transforms how plants are operated. This work describes the Evaluation of an integrated operations concept that draws together data from existing Instrumentation and Control (I&C) infrastructure, upgraded I&C systems, new sensors, and field technologies such as computer-based procedures to provide operators with centralized, streamlined instructions. The concept was developed to allow for an operator to remotely supervise many plant activities and to dramatically streamline plant operations and maintenance. This describes the methods, results, and design recommendations for the concept based on an operator workshop to evaluate the concept.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Use of Digital Real-Time Simulation and Optimization to Identify Maximum Real Power Injection on Banshee Distribution Network

This study investigates the hosting capacity of the Banshee Distribution Network by optimizing the real power injection at carefully selected Distributed Energy Resource (DER) locations. The analysis is conducted within the framework of power system operational constraints, including bus voltage ranges, thermal line ratings, and transformer loading limits. A Python-based Genetic Algorithm (GA), implemented using the PyGAD library, is employed to iteratively identify the optimal power injection configuration that maximizes network utilization while preserving system reliability. The methodology integrates a real-time simulation environment using the Real-Time Digital Simulator (RTDS), allowing high-fidelity evaluation of power flow and voltage behavior under each proposed injection scenario. By coupling the optimization algorithm with real-time simulation feedback, this approach ensures that both static and dynamic constraints are enforced during the evaluation process. The GA leverages evolutionary operators such as selection, crossover, and mutation to navigate the nonlinear search space efficiently. The results of the study delineate the feasible hosting capacity at three targeted buses, reflecting maximum real power levels that can be injected without causing voltage violations, transformer overloading, or line congestion. These findings provide a decision- support tool for distribution planners and utilities aiming to integrate higher penetrations of DERs in existing infrastructure. Additionally, the work lays the foundation for extending such optimization techniques to multi-objective formulations, including economic dispatch and reactive power coordination, in future studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Formally Verified ZTA Requirements for OT/ICS Environments with Isabelle/HOL: Preprint

The clean energy transformation led to the integration of distributed energy resources on a top of the grid, and so a substantial increase in the complexity of power grids infrastructure and the underlying operational technology environment. Operational technology environments are becoming a system of systems, integrating heterogeneous devices which are software/hardware intensive, have ever increasing demands to exploit advances in commodity of software/hardware infrastructures, and this for good reasons - improving energy systems requirements such as cybersecurity and resilience. In such a setting, system requirements at different levels mix, thus undesirable outcomes will surely happen. The use of formal methods will remove ambiguity, increase automation and provide high levels of assurance and reliability. In this paper, we contribute a methodology and a framework for the system level verification of zero trust architecture requirements in operational technology environments. We define a formal specification for the core functionalities of operational technology environments, the corresponding invariants, and security proofs. Of particular note is our modular approach for the formal verification of asynchronous interactions in operational technology environments. The formal specification and the proofs have been mechanized using the interactive theorem proving environment Isabelle/HOL.

formal methods↗

Use of Digital Real-Time Simulation and Optimization to Identify Maximum Real Power Injection on the Banshee Distribution Network: Preprint

This study investigates the hosting capacity of the Banshee Distribution Network by optimizing the real power injection at carefully selected Distributed Energy Resource (DER) locations. The analysis is conducted within the framework of power system operational constraints, including bus voltage ranges, thermal line ratings, and transformer loading limits. A Python-based Genetic Algorithm (GA), implemented using the PyGAD library, is employed to iteratively identify the optimal power injection configuration that maximizes network utilization while preserving system reliability. The methodology integrates a real-time simulation environment using the Real-Time Digital Simulator (RTDS), allowing high-fidelity evaluation of power flow and voltage behavior under each proposed injection scenario. By coupling the optimization algorithm with real-time simulation feedback, this approach ensures that both static and dynamic constraints are enforced during the evaluation process. The GA leverages evolutionary operators such as selection, crossover, and mutation to navigate the nonlinear search space efficiently. The results of the study delineate the feasible hosting capacity at three targeted buses, reflecting maximum real power levels that can be injected without causing voltage violations, transformer overloading, or line congestion. These findings provide a decision- support tool for distribution planners and utilities aiming to integrate higher penetrations of DERs in existing infrastructure. Additionally, the work lays the foundation for extending such optimization techniques to multi-objective formulations, including economic dispatch and reactive power coordination, in future studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗