Search NASASearch

SEARCH · Search NASA

Results for “Instrument optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A unified approach to aircraft parameter identification

The most accurate identification results are obtained when all three elements of the identification process - the identification algorithm, the control input, and the instrumentation system - are considered in a unified approach. This type of approach for the design of optimal control inputs and for determining the effect of the instrumentation system, in each case with respect to the identification process is discussed. Design of control inputs which optimize the sensitivity of the system output to the unknown parameters is given. Results using these inputs in an extensive simulation of the identification process indicate they perform measurably better than doublet type inputs. A technique is then presented for specifying an optimal instrumentation system or for determining the effect, the instrumentation system has on the accuracy of the parameter estimates.

Stepner, D. E.

STOP Analysis and Optimization of a Very-Low-Distortion Space Instrument: HST WFC3 Case Study

New generation optical instruments with very demanding stability requirements are being proposed and developed for space applications. STOP (Structural-Thermal-Optical Performance) analysis and optimization is crucial in meeting the very tight distortion budgets of these instruments. This presentation outlines STOP analysis and optimization approach in the context of WFC3 (Wide-Field Camera 3), which is a radial instrument designed to replace the Wide-Field Planetary Camera 2 (WFPC2) of the Hubble Space Telescope (HST). WFC3 houses two separate channels, UVIS and IR, and will have greater throughput and sensitivity than WFPC2. WFC3 line-of-sight alignment budget for the UVIS and IR channels are as small as 10 and 20 milli-arcsec, respectively. Its optical bench is the most critical subsystem effecting the optical stability of WFC3 hence our effort concentrates on the design and analysis of the bench and its interfaces. Structural analysis has accompanied the mechanical design of the bench since the initial concept study. A high fidelity structural Finite Element Model (FEM) of the bench has been developed and used for minimizing its thermally induced distortions as well as sizing it to meet the stiffness and strength requirements of a Shuttle launch. The bench is a composite honeycomb panel box structure with a very low planar Coefficient of Thermal Expansion (CTE) of approximately 0.1 ppm/C. Optic components are mounted to super-INVAR inserts bonded into the panels. The bench is kinematically supported on three HST latches via interface struts, which are tailored to exhibit negative CTE to cancel out the thermal motions of the latches. The interface struts also incorporate flexure elements to minimize the mechanical distortions coming into the bench from its enclosure. Bench FEM is coupled with the enclosure FEM to quantify these effects. Short term or on-orbit STOP analysis includes distortion due to the temperature variations of the bench, the struts, and the enclosure. Long term or ground-to-orbit STOP analysis includes distortional effects of gravity release, desorption, and assembly in addition to the ground-to-orbit temperature variations. A rigorous testing program has been implemented for verifying the material properties and the analysis predictions. STOP analysis results demonstrate that both the short-term and the long-term alignment budgets will be met. Presentation will cover design and analysis details that are critical to a successful implementation of the STOP analysis and optimization process.

Kunt, Cengiz

Progress in end-to-end optimization of fundamental physics experimental apparata with differentiable programming

In this article we examine recent developments in the research area concerning the creation of end-to-end models for the complete optimization of measuring instruments. The models we consider rely on differentiable programming methods and on the specification of a software pipeline including all factors impacting performance — from the data-generating processes to their reconstruction and the inference on the parameters of interest — along with the careful specification of a utility function well aligned with the end goals of the experiment. Building on previous studies originated within the MODE Collaboration, we focus specifically on applications involving instruments for particle physics experimentation, as well as industrial and medical applications that share the detection of radiation as their data-generating mechanism. This report illustrates the most recent advancements in the area, and outlines, for each of the discussed applications as well as for automatic differentiation itself, ongoing and future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Report on the "Symposium on Advancements in Simulating Neutron Scattering Instruments and Experiments"

An international group of researchers gathered for the “Symposium on Advancements in Simulating Neutron Scattering Instruments and Experiments” at Oak Ridge National Laboratory (ORNL) on October 29- 30, 2024. The symposium highlighted state-of-the-art advancements in neutron scattering instrument simulations and the development of digital twins for scattering instruments. This document summarizes the recurring themes from the 19 talks and discussions. A key focus was on the role of neutronics simulations in the design, analysis, and performance optimization of neutron instruments. Presentations featured the most widely used software packages, such as McStas, McVine, Vitess, and MCNP. Another major theme addressed the analysis and interpretation of experimental neutron data, where materials models and simulations play a critical role. Talks on relevant software tools, including NCrystal, OCLimax, and Paradyse, were delivered by their respective developers. During the symposium, both talks and breakout sessions explored strategies to enhance the interplay between neutronics simulations and materials models. A key question emerged: How can we develop a RealTime Explainable Digital Twin of a neutron scattering experiment? Discussions include the idea that the Digital Twin concept has implications for instrument control and testing. Through this symposium, we gained valuable insights into the challenges and requirements for developing a Real-Time Explainable Digital Twin of a neutron scattering experiment. The discussions and presentations paved the way for future innovations in this rapidly advancing field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

The Influence of Mineralogy on Recovering Organic Acids from Mars Analogue Materials Using the One-Pot Derivatization Experiment on the Sample Analysis at Mars(SAM) Instrument Suite

The search for complex organic molecules on Mars, including important biomolecules such as amino acids and carboxylic acids, will require a chemical extraction and a derivatization step to transform these organic compounds into species that are sufficiently volatile to be detected by gas chromatography mass spectrometry (GCMS). We have developed a ''one-pot'' extraction and chemical derivatization protocol using N-methyl-N-(tert-butyldimethylsilyl) trifluoroacetamide (MTBSTFA) and dimethylformamide (DMF) for the Sample Analysis at Mars (SAM) experiment instrument suite on NASA's the Mars Science Laboratory (MSL) mission. The temperature and duration of the derivatization reaction, pre-concentration of chemical derivatives, and gas chromatographic separation parameters have been optimized under SAM instrument design constraints. MTBSTFA/DMF extraction and derivatization at 300 1C for several minutes of a variety of terrestrial Mars analog materials facilitated the detection of amino acids and carboxylic acids in a surface soil sample collected from the Atacama Desert and a carbonate-rich stromatolite sample from Svalbard. However, the rapid reaction of MTBSTFA with water in several analog materials that contained high abundances of hydrated minerals, and the possible deactivation of derivatized compounds by iron oxides, as detected by XRD/XRF using the CheMin field unit Terra, proved to be highly problematic for the direct extraction of organics using MTBSTFA. The combination of pyrolysis and two different wet-chemical derivatization methods employed by SAM should enable a wide range of organic compounds to be detected by GCMS if present on Mars.

MSL

A laser velocimeter system for small radial turbomachinery

The paper describes the design and test of a laser Doppler velocimeter (LDV) to map the velocity fields in small high-speed turbomachinery. This instrument is presently being used as a diagnostic tool for the study of the basic fluid dynamics of the inducer, impeller and the diffuser regions of high-pressure-ratio small centrifugal compressors. The LDV instrumentation has been optimized to permit measurement of instantaneous velocities up to approximately 500 m/s within a rotating impeller. It is shown that LDV can make nondisturbing gas velocity measurements and surmount the difficulties found in applying other types of aerodynamic instrumentation, e.g., hot-wire anemometers, to this measurement problem.

Runstadler, P. W., Jr.

TES Pixel Optimization for the ATHENA X-IFU Instrument

ATHENA is a European led x-ray observatory due for launch in the early 2030s. The X-ray Integral Field Unit (X-IFU) instrument on ATHENA will have an array of 3168 TES microcalorimeters, 2.5 eV resolution (at 7 keV), 5 arc second angular resolution and a 5 arc minute field of view. As one example, will allow unprecedented views of composition and dynamics of galaxy clusters.

Wakeham, Nick

The INTEGRAL scatterometer SPI

The INTErnational Gamma Ray Astrophysics Laboratory (INTEGRAL) mission's onboard spectrometer, the INTEGRAL spectrometer (SPI), is described. The SPI constitutes one of the four main mission instruments. It is optimized for detailed measurements of gamma ray lines and for the mapping of diffuse sources. It combines a coded aperture mask with an array of large volume, high purity germanium detectors. The detectors make precise measurements of the gamma ray energies over the 20 keV to 8 MeV range. The instrument's characteristics are described and the Monte Carlo simulation of its performance is outlined. It will be possible to study gamma ray emission from compact objects or line profiles with a high energy resolution and a high angular resolution.

Mandrou, P.

The Dawn of Geostationary Air Quality Monitoring: Case Studies from Seoul and Los Angeles

With the near-future launch of geostationary pollution monitoring satellite instruments over North America, East Asia, and Europe, the air quality community is preparing for an integrated global atmospheric composition observing system at unprecedented spatial and temporal resolutions. One of the ways that NASA has supported this community preparation is through demonstration of future space-borne capabilities using the Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) airborne instrument. This paper integrates repeated high-resolution maps from GeoTASO, ground-based Pandora spectrometers, and low Earth orbit measurements from the Ozone Mapping and Profiler Suite (OMPS), for case studies over two metropolitan areas: Seoul, South Korea on June 9, 2016 and Los Angeles, California on June 27, 2017. This dataset provides a unique opportunity to illustrate how geostationary air quality monitoring platforms and ground-based remote sensing networks will close the current spatiotemporal observation gap. GeoTASO observes large differences in diurnal behavior between these urban areas, with NO2 accumulating within the Seoul Metropolitan Area through the day but NO2 peaking in the morning and decreasing throughout the afternoon in the Los Angeles Basin. In both areas, the earliest morning maps exhibit spatial patterns similar to emission source areas (e.g., urbanized valleys, roadways, major airports). These spatial patterns change later in the day due to boundary layer dynamics, horizontal transport, and chemistry. The nominal resolution of GeoTASO is finer than will be obtained from geostationary platforms, but when NO2 data over Los Angeles are up-scaled to the expected resolution of TEMPO, spatial features discussed are conserved. Pandora instruments installed in both metropolitan areas capture the diurnal patterns observed by GeoTASO, continuously and over longer time periods, and will play a critical role in validation of the next generation of satellite measurement. These case studies demonstrate that different regions can have diverse diurnal patterns and that day-to-day variability due to meteorology or anthropogenic patterns such as weekday/weekend variations in emissions is large. Low Earth orbit measurements, despite their inability to capture the diurnal patterns at fine spatial resolution, will be essential for intercalibrating the geostationary radiances and cross-validating the geostationary retrievals in an integrated global observing system.

Geostationary

It's a Trap! A Review of MOMA and Other Ion Traps in Space or Under Development

Since the Viking Program, quadrupole mass spectrometer (QMS) instruments have been used to explore a wide survey of planetary targets in our solar system, including (from the inner to outer reaches): Venus (Pioneer); our moon (LADEE); Mars (Viking, Phoenix, and Mars Science Laboratory); and, Saturns largest moon Titan (Cassini-Huygens). More recently, however, ion trap mass spectrometer (ITMS) instruments have found a niche as smaller, versatile alternatives to traditional quadrupole mass analyzers, capable of in situ characterization of planetary environments and the search for organic matter. For example, whereas typical QMS systems are limited to a mass range up to 500 Da and normally require multiple RF frequencies and pressures of less than 10(exp -6) mbar for optimal operation, ITMS instruments commonly reach upwards of 1000 Da or more on a single RF frequency, and function in higher pressure environments up to 10(exp -3) mbar.

ion trap

Design, development, and test of a laser velocimeter for high speed turbomachinery

The paper describes the design, development, and test of a laser Doppler velocimeter (LDV) to map the velocity fields in a small, high speed, 8:1 pressure ratio, 0.91 kg/s (2 lbm/s), centrifugal compressor. This instrument is being used as a diagnostic tool for the study of the basic fluid dynamics of the inducer, impeller and the diffuser regions of high pressure ratio, small, centrifugal compressors. The LDV instrumentation has been optimized to permit the measurement of instantaneous velocities up to approximately 500 m/s, measured in absolute coordinates, within a rotating compressor impeller. Velocities of the same magnitude can also be measured in the two-dimensional radial plane of the diffuser. It is shown that LDV can make nondisturbing gas velocity measurements and surmount the difficulties found in applying other types of aerodynamic instrumentation to this measurement problem.

Runstadler, P. W., Jr.

mzPeak: Designing a Scalable, Interoperable, and Future-Ready Mass Spectrometry Data Format

Advances in mass spectrometry (MS) instrumentation, such as higher resolution, faster scan speeds, and improved sensitivity, have significantly increased the volume and complexity of data. The growing adoption of imaging and ion mobility further amplifies these challenges across MS-based omics fields, including proteomics, metabolomics, and lipidomics. While these technologies unlock new possibilities, they also present significant challenges in data management, storage, and accessibility. Existing open formats, such as the XML-based community standards mzML and imzML, struggle to meet the demands of modern MS workflows due to their large file sizes, slow data access, and limited metadata support. Vendor-specific formats, while optimized for proprietary instruments, lack interoperability, comprehensive metadata support and long-term archival reliability. This white paper lays the groundwork for mzPeak, a next-generation community data format designed to address these challenges and support high-throughput, multi-dimensional MS workflows. By adopting a hybrid model that combines efficient binary storage for numerical data and both human and machine-readable metadata storage, mzPeak will reduce file sizes, accelerate data access, and offer a scalable, adaptable solution for evolving MS technologies. For researchers, mzPeak will enable enhanced interoperability across platforms, seamless support for complex workflows including ion mobility and MS imaging, and faster data access compared to existing community formats such as mzML. Its design will ensure data is managed in compliance with regulatory standards, essential for applications such as precision medicine and chemical safety, where long-term data integrity and accessibility are critical. For vendors, mzPeak provides a streamlined, open alternative to proprietary formats, reducing the burden of regulatory compliance while aligning with the industry's push for transparency and standardization. By offering a high-performance, interoperable solution, mzPeak positions vendors to meet customer demands for sustainable data management tools which will be able to handle emerging and future data types and workflows. mzPeak aspires to become the cornerstone of MS data management, empowering researchers, vendors, and developers to innovate and collaborate more effectively.

data formats

Raytracing for Multi-Spacecraft Missions

The numerical simulation of in-situ instruments allows the instrument design to be optimized for particle throughput and allows for the iteration of the design parameters before fabrication. This effort leads to greater efficiency since the hardware itself does not have to be machined and fabricated to test each design change. More importantly for multi-spacecraft missions, the numerical raytracing allows the assessment of manufacturing tolerances so that a low relative accuracy can be obtained between the instruments. We will discuss our experience in optimizing and raytracing our charged particle instruments, obtaining the geometry factor from these simulations, and the comparison with the results of laboratory testing. This discussion with others will support the ISSI Scientific Report on Calibration Techniques for In-Situ Plasma Instrumentation.

Coffey, Victoria

A Bayesian Approach to Sensor Characterization

The physical model of a generic electro-optic sensor is derived and incorporated into a Bayesian framework for the estimation of key instrument parameters from calibration data. The sensor characterization thus achieved enables optimal subsequent removal of instrument effects from field data, leading to the highest possible accuracy in the retrieved physical quantities.

Timucin, Dogan A.

Single-Particle Isotopic Analysis Using the Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Coupled to an Orbitrap Mass Spectrometer

Isotope ratio (IR) determinations on individual particles can provide valuable information relative to the sample, including processing and dating, which could be valuable to geological and nuclear material analysis communities. In comparison to “bulk” measurements, in which all particle information is lost and homogenized within a sample, “particle” measurements allow for fingerprinting and can provide unique insights related to the sample’s nano- and micro- compositions. Furthermore, the complex nature of particles, with potential isobaric interferences from either the matrix or other elements within the same particle, poses a significant analytical challenge for conventional mass spectrometry platforms employed for elemental analysis due to their limited mass resolution. Presented here is the first demonstration of an ultrahigh resolution method for single particle (SP) isotopic analysis using the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an Orbitrap mass spectrometer and FTMS Booster X2T acquisition/processing system. For proof of concept, well-characterized CeO 2 microparticles with a nominal diameter of 1.0 μm were analyzed at a mass resolution of ∼330,000. Important instrumental parameters were optimized to enable the detection of single particles. The 142 Ce/ 140 Ce ratio of individual particles and the population average were determined and compared to an SP inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS) analysis. The isotopic accuracy and precision were determined by two methods and found to be in good agreement with the SP-ICP-TOF-MS method, with the linear regression slope method providing a more accurate ratio, showing a ∼1.4% relative difference from the ratio determined from a particle digest. The encouraging performance of the method was further supported by a determined detection limit of 2.9 fg ( 142 Ce). The developed method is anticipated to overcome many of the challenges posed by isobaric interferences encountered in conventional mass spectrometry techniques when analyzing real-world samples for particle isotopic composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Direct and rapid uranium isotopic analysis of environmental sample swipes via microextraction – LS-APGD/Orbitrap mass spectrometry

Accurate and precise isotopic analysis of actinides collected on environmental sample swipes from within nuclear facilities is an important safeguarding measure for detecting undeclared materials and activities. Traditional isotope ratio (IR) analysis of actinides using a bulk digestion approach can be laborious and time-consuming. Recently, direct analysis of environmental swipe samples using a microextraction approach has been explored as an alternative to conventional bulk digestion methods. The present study further evaluates this approach for accurate and precise isotopic analysis of uranium (U) in cotton swipe samples using the liquid sampling-atmospheric pressure glow discharge (LS-APGD)/Orbitrap-FTMS Booster detection system. The instrumental parameters were optimized, and quantitative capabilities were demonstrated through excellent linearity (R2 = 0.99) across a deposited mass range of 1 to 500 ng, with a limit of detection of 90 pg (in a 2 × 4 mm region) for total U; well below typical U concentrations (ng–mg range) in environmental sample swipes. The 235U/238U ratio showed excellent accuracy (−0.3% relative difference from the certificate value), with ∼20× improvement over previous microextraction-Orbitrap methods. Precision (∼1% relative standard deviation) was also greatly enhanced by ∼5×. This study also demonstrates that figures of merit achieved with neat U solution were not highly degraded when various external interfering elements/matrices were introduced. Finally, the developed method was successfully applied to analyze practical swipe samples representative of laboratory and outdoor environments. The presented figures of merit and applicability to practical samples further validate the capability of the platform for rapid analysis (<7 minutes) of environmental swipe samples.

Shrestha, Suraj [Clemson University, SC]

ChatHPC: Building the Foundations for a Productive and Trustworthy AI-Assisted HPC Ecosystem

ChatHPC democratizes large language models for the high-performance computing (HPC) community by providing the infrastructure, ecosystem, and knowledge needed to apply modern generative AI technologies to rapidly create specific capabilities for critical HPC components while using relatively modest computational resources. Our divide-and-conquer approach focuses on creating a collection of reliable, highly specialized, and optimized AI assistants for HPC based on the cost-effective and fast Code Llama fine-tuning processes and expert supervision. We target major components of the HPC software stack, including programming models, runtimes, I/O, tooling, and math libraries. Thanks to AI, ChatHPC provides a more productive HPC ecosystem by boosting important tasks related to portability, parallelization, optimization, scalability, and instrumentation, among others. With relatively small datasets (on the order of KB), the AI assistants, which are created in a few minutes by using one node with two NVIDIA H100 GPUs and the ChatHPC library, can create new capabilities with Meta’s 7-billion parameter Code Llama base model to produce high-quality software with a level of trustworthiness of up to 90% higher than the 1.8-trillion parameter OpenAI ChatGPT-4o model for critical programming tasks in the HPC software stack.

Young, Aaron [ORNL] (ORCID:0000000254484667)