Search NASA⌕ Search

SEARCH · Search NASA

Results for “Intercalibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Global temperature variations

Intercalibration statistics of all Microwave Sounding Units (MSUs) operating through 1990 were computed and brightness temperature anomalies on various space and time scales were compiled for MSU channels 2 (troposphere) and 4 (lower stratosphere). A tropospheric retrieval was developed through combination of channel 2 data from various view angles across the MSU scan swath to achieve cancellation of the influence of the lower stratosphere, and much of the upper troposphere, on that channel. Radiosonde validation of the MSU channel 2 and tropospheric retrieval anomalies was performed with 10 years of data at all U.S. controlled stations.

Spencer, Roy W.↗

Precision and radiosonde validation of satellite gridpoint temperature anomalies. I - MSU channel 2. II - A tropospheric retrieval and trends during 1979-90

Monthly 2.5-deg gridpoint anomalies in the Tiros-N satellite series Microwave Sounding Unit channel 2 brightness temperatures during 1979-1988 are evaluated with multiple satellites and radiosonde data for their climate temperature monitoring capability. The MSU anomalies are computed about a 10-yr mean annual cycle at each gridpoint, with the MSUs intercalibrated to a common arbitrary level. The monthly gridpoint anomaly agreement between concurrently operating satellites reveals single-satellite precision generally better than 0.07 C in the tropics and better than 0.15 C at higher latitudes. The removal from channel 2 of the temperature influence above the 30-kPa level is addressed, providing a sharper and thus potentially more useful weighting function for monitoring lower tropospheric temperatures.

Spencer, Roy W.↗

Calibration of the AVHRR visible and near IR channels using radiances measured over remote ocean areas

An inflight absolute calibration method has been adapted and applied to channel 1 of the AVHRR. The approach is based on AVHRR observations in channels 1, 2 and 4. A rigorous cloud screening is performed, based on the homogeneity of the data in channel 1 and 2 and on the temperature in channel 4. In a combined approach, the off-nadir view satellite count in channel 2 is used to detect the aerosol optical thickness and loading and the count of channel 1 is used to calibrate this channel, based on the predictable Rayleigh scattering component. Water vapor data are used, and the channels are intercalibrated using the ratio between channels 1 and 2 over the glint region.

Vermote, Eric F.↗

Precision lower stratospheric temperature monitoring with the MSU - Technique, validation, and results 1979-1991

The stability of TIROS-N Microwave Sounding Unit (MSU) channel 4, which monitors the deep-layer averaged temperature of the lower stratosphere, is tested by intercalibrating MSU channel 4 data from the NIROS-N series of NOAA satellites during 1979-1991. The monthly gridpoint anomalies are validated with 10 years of radiosonde data during 1979-1988. The results demonstrated that the satellite sensors are very stable in their calibration and that the previously reported uncertainties in the stratospheric temperature information produced by NOAA are not the result of calibration changes in the MSUs. It was found that the largest globally averaged temperature variations during 1979-1991 occur after the El Chichon (1982) and Pinatubo (1991) volcanic eruptions. These warm events are superimposed upon a net downward trend in temperatures during the period. The cooling trend is strongest in polar regions and the Northern Hemisphere middle latitudes.

Spencer, Roy W.↗

SeaWiFS technical report series. Volume 20: The SeaWiFS bio-optical archive and storage system (SeaBASS), part 1

This document provides an overview of the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Bio-Optical Archive and Storage System (SeaBASS), which will serve as a repository for numerous data sets of interest to the SeaWiFS Science Team and other approved investigators in the oceanographic community. The data collected will be those data sets suitable for the development and evaluation of bio-optical algorithms which include results from SeaWiFS Intercalibration Round-Robin Experiments (SIRREXs), prelaunch characterization of the SeaWiFS instrument by its manufacturer -- Hughes/Santa Barbara Research Center (SBRC), Marine Optical Characterization Experiment (MOCE) cruises, Marine Optical Buoy (MOBY) deployments and refurbishments, and field studies of other scientists outside of NASA. The primary goal of the data system is to provide a simple mechanism for querying the available archive and requesting specific items, while assuring that the data is made available only to authorized users. The design, construction, and maintenance of SeaBASS is the responsibility of the SeaWiFS Calibration and Validation Team (CVT). This report is concerned with documenting the execution of this task by the CVT and consists of a series of chapters detailing the various data sets involved. The topics presented are as follows: 1) overview of the SeaBASS file architecture, 2) the bio-optical data system, 3) the historical pigment database, 4) the SIRREX database, and 5) the SBRC database.

Hooker, Stanford B.↗

Long term trend of selected halogenated hydrocarbons

The so-called 'Library of Background Air' at the Oregon Graduate Institute was used to determine the trend in volume mixing ratios of selected halogenated hydrocarbons in the time period 1977-1989. This library consists of background air samples most of them taken at Cape Meares (Oregon). For storage stainless steel containers are used. Tests have shown the gases under consideration to be stable in these containers. Analyses using a GC/MS-system were performed for the CFCs 11, 12, 12B1 (HALON 1211, CBrClF2), 22, 113, 114 and CH3Cl, CH3Br, CH3CCl3, CCl4. The advantage of this unique investigation: different aged air samples are analyzed at the same time with the same instrument. No calibrations or intercalibrations are needed. All data are presented in normalized mixing ratios versus time. We discuss the results, derive rate constants and present a formula to describe the nonlinear increases.

Borchers, R.↗

Reevaluation of the NOAA/CMDL carbon monoxide reference scale and comparisons with CO reference gases at NASA-Langley and the Fraunhofer Institut

The carbon monoxide (CO) reference scale created by the National Oceanic and Atmospheric Administration/Climate Monitoring and Diagnostics Laboratory (NOAA/CMDL) is used to quantify measurements of CO in the atmosphere, calibrate standards of other laboratories and to otherwise provide reference gases to the community measuring atmospheric CO. This reference scale was created based upon a set of primary standards prepared by gravimetric methods at CMDL and has been propagated to a set of working standards. In this paper we compare CO mixing ratios assigned to the working standards by three approaches: (1) calibration against the original gravimetric standards, (2) calibration using only working standards as the reference gas, and (3) calibration against three new gravimetric standards prepared to CMDL. The agreement between these values was typically better than 1%. The calibration histories of CMDL working standards are reviewed with respect to expected rates of CO change in the atmosphere. Using a Monte Carlo approach to simulate the effect of drifting standards on calculated mixing ratios, we conclude that the error solely associated with the maintenance of standards will limit the ability to detect small CO changes in the atmosphere. We also report results of intercalibration experiments conducted between CMDL and the Diode Laser Sensor Group (DACOM) at the NASA Langley Research Center (Hampton, Virginia), and CMDL and the Fraunhofer-Institut (Garmisch-Partenkirchen, Germany). Each laboratory calibrated several working standards for CO using their reference gases, and these results were compared to calibrations conducted by CMDL. The intercomparison of eight standards (CO concentrations between approximately 100 and approximately 165 ppb) by CMDL and NASA agreed to better than +/- 2%. The calibration of six standards (CO concentrations between approximately 50 and approximately 210 ppb) by CMDL and the Fraunhofer-Institut agreed to within +/- 2% for four standards, and to within +/- 5% for all six standards.

Novelli, P. C.↗

Measurements of dimethyl sulfide and H2S over the western North Atlantic and the tropical Atlantic

Airborne measurements of DMS and H2S were made off the east coast of the United States and over the tropical Atlantic off Brazil. Samples were collected through a fluorinated ethylene propylene Teflon inlet manifold. Dimethyl sulfide (DMS) was preconcentrated onto gold wool and analyzed by gas chromatography/flame photometric detection. H2S was collected on AgNO3-impregnated filters and determined by fluorescence quenching. Use of a new scrubber material (cotton) to remove negative interference on DMS measurements was investigated. Comparison with a Na2CO3/Anakrom scrubber gave good overall agreement. Only under extreme conditions, e.g., on flight 9 (continental air mass, low humidity, high O3, and low DMS values) did Na2CO3 show noticeable loss of DMS compared to cotton. On most flights, especially in marine air masses with high humidity and relatively low O3, the results from both scrubbers agreed well with each other and with other instruments used during the intercalibration. Off the U.S. East Coast, DMS levels showed strong dependence on air mass origin with high values (up to 83 ppt) in marine tropical air masses and low values (10-20 ppt) in continental and polar air. Over the tropical Atlantic, DMS ranged over 20-100 ppt in the mixed layer. Nighttime values were a factor of 1.6-2.3 higher than daytime levels. DMS decreased with altitude to less than 1 ppt at 4000 m. H2S in the mixed layer off the U.S. East Coast ranged from 10 to 200 ppt. Significant influence from terrestrial and pollution sources was evident. H2S in air masses originating over the eastern seaboard was much higher than in continental polar air or over the remote tropical continents. In contrast, over the tropical Atlantic, concentrations were very low (5-10 ppt), typical of truly marine air. Night/day ratios were about 1.4. No significant geographical variability was seen in H2S levels over the tropical Atlantic. The correlation of atmospheric Rn-222 and H2S was significant, with both being higher off the U.S. East Coast than over the tropical Atlantic.

Andreae, T. W.↗

Improved Estimates of Clear Sky Longwave Flux and Application to the Tropical Greenhouse Effect

The first objective of this investigation is to eliminate the clear-sky offset introduced by the scene-identification procedures developed for the Earth Radiation Budget Experiment (ERBE). Estimates of this systematic bias range from 10 to as high as 30 W/sq m. The initial version of the ScaRaB data is being processed with the original ERBE algorithm. Since the ERBE procedure for scene identification is based upon zonal flux averages, clear scenes with longwave emission well below the zonal mean value are mistakenly classified as cloudy. The erroneous classification is more frequent in regions with deep convection and enhanced mid- and upper-tropospheric humidity. We will develop scene identification parameters with zonal and/or time dependence to reduce or eliminate the bias in the clear- sky data. The modified scene identification procedure could be used for the ScaRaB-specific version of the Earth-radiation products. The second objective is to investigate changes in the clear-sky Outgoing Longwave Radiation (OLR) associated with decadal variations in the tropical and subtropical climate. There is considerable evidence for a shift in the climate state starting in approximately 1977. The shift is accompanied by higher SSTs in the equatorial Pacific, increased tropical convection, and higher values of atmospheric humidity. Other evidence indicates that the humidity in the tropical troposphere has been steadily increasing over the last 30 years. It is not known whether the atmospheric greenhouse effect has increased during this period in response to these changes in SST and precipitable water. We will investigate the decadal-scale fluctuations in the greenhouse effect using Nimbus-7, ERBE, and ScaRaB measurements spaning 1979 to the present. The data from the different satellites will be intercalibrated by comparison with model calculations based upon ship radiosonde observations. The fluxes calculated from the radiation model will also be used for validation of the ScaRaB fluxes.

Collins, W. D.↗

Validation of the Version 1 NOAA/NASA Pathfinder Sea Surface Temperature Data Set

A high-resolution, global satellite-derived sea surface temperature (SST) data set called Pathfinder, from the Advanced Very High Resolution Radiometer (AVHRR) aboard the NOAA Polar Orbiters, is available from the Jet Propulsion Laboratory Physical Oceanography Distributed Active Archive Center (JPL PO.DAAC). Suitable for research as well as education, the Pathfinder SST data set is a result of a collaboration between the National Oceanographic and Atmospheric Administration (NOAA), the National Aeronautics and Space Administration (NASA) and investigators at several universities. NOAA and NASA are the sponsors of the Pathfinder Program, which takes advantage of currently archived Earth science data from satellites. Where necessary, satellite sensors have been intercalibrated, algorithms improved and processing procedures revised, in order to produce long time-series, global measurements of ocean, land and atmospheric properties necessary for climate research. Many Pathfinder data sets are available to researchers now, nearly a decade before the first launch of NASA's Earth Observing System (EOS). The lessons learned from the Pathfinder programs will facilitate the processing and management of terabytes of data from EOS. The Oceans component of Pathfinder has undertaken to reprocess all Global Area Coverage (GAC) data acquired by the 5-channel AVHRRs since 1981. The resultant data products are consistent and stably calibrated [Rao, 1993a, Rao, 1993b, Brown et al., 1993], Earth-gridded SST fields at a variety of spatial and temporal resolutions.

Smith, Elizabeth A.↗

SeaWiFS Postlaunch Technical Report Series: The SeaWiFS Transfer Radiometer (SXR) - Volume 1

The SeaWiFS Transfer Radiometer (SXR) was built for the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Project as part of an Interagency Agreement with the National Aeronautics and Space Administration (NASA). The SXR is a multichannel radiometer designed to verify and compare measurements of spectral radiance at six discrete wavelengths in the visible and near infrared for various calibration sources in the SeaWiFS Project. In addition, the SXR is used to compare these sources to standards of spectral radiance maintained at the National Institute of Standards and Technology (NIST). The SXR was designed, built, and thoroughly characterized in the Optical Technology Division at NIST. A unique optical design provides six independent optical paths, each equipped with a temperature stabilized interference filter and silicon photodiode. A separate beam path through the input lens is used to visually align the SXR. The entrance windows for each channel overlap at the source, with each channel sampling a unique solid angle within the field of view of the SXR; this allows for simultaneous sampling of all channels. The combined standard relative uncertainty of spectral radiance measurements with the SXR is estimated to be between 0.6% and 1.3%. This report describes the design and construction of the SXR in detail, and gives the results of the optical characterization and calibrations done at NIST. The SXR has been used for several intercomparisons which include several SeaWiFS Intercalibration Round-Robin Experiments (SIRREXs); those done at the Marine Optical Buoy (MOBY) laboratories in Honolulu, Hawaii; at the NEC Corporation in Yokohama, Japan; and Orbital Sciences Corporation (OSC) in Germantown, Maryland. Thorough optical characterization and calibration of the SXR was essential to the successful application of the radiometer for these measurements.

Johnson, B. Carol↗

SeaWiFS Postlaunch Technical Report Series: The SeaWiFS Transfer Radiometer (SXR) - Volume 1

The SeaWiFS Transfer Radiometer (SXR) was built for the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Project as part of an Interagency Agreement with the National Aeronautics and Space Administration (NASA). The SXR is a multichannel radiometer designed to verify and compare measurements of spectral radiance at six discrete wavelengths in the visible and near infrared for various calibration sources in the SeaWiFS Project. In addition, the SXR is used to compare these sources to standards of spectral radiance maintained at the National Institute of Standards and Technology (NIST). The SXR was designed, built, and thoroughly characterized in the Optical Technology Division at NIST. A unique optical design provides six independent optical paths, each equipped with a temperature stabilized interference filter and silicon photodiode. A separate beam path through the input lens is used to visually align the SXR. The entrance windows for each channel overlap at the source, with each channel sampling a unique solid angle within the field of view of the SXR; this allows for simultaneous sampling of all channels. The combined standard relative uncertainty of spectral radiance measurements with the SXR is estimated to be between 0.6% and 1.3%. This report describes the design and construction of the SXR in detail, and gives the results of the optical characterization and calibrations done at NIST. The SXR has been used for several intercomparisons which include several SeaWiFS Intercalibration Round-Robin Experiments (SIRREXs); those done at the Marine Optical Buoy (MOBY) laboratories in Honolulu, Hawaii; at the NEC Corporation in Yokohama, Japan; and Orbital Sciences Corporation (OSC) in Germantown, Maryland. Thorough optical characterization and calibration of the SXR was essential to the successful application of the radiometer for these measurements.

Hooker, Stanford B.↗

SeaWiFS Postlaunch Technical Report Series: The SeaBOARR-98 Field Campaign - Volume 3

This report documents the scientific activities during the first Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Bio-Optical Algorithm Round-Robin (SeaBOARR-98) experiment, which took place from 5-17 July 1998, at the Acqua Alta Oceanographic Tower (AAOT) in the northern Adriatic Sea off the coast of Italy. The ultimate objective of the SeaBOARR activity is to evaluate the effect of different measurement protocols on bio-optical algorithms using data from a variety of field campaigns. The SeaBOARR-98 field campaign was concerned with collecting a high quality data set of simultaneous in-water and above-water radiometric measurements. The deployment goals documented in this report were to: a) use four different surface glint correction methods to compute water-leaving radiances, L W (lambda), from above-water data; b) use two different in-water profiling systems and three different methods to compute L W (lambda) from in-water data (one making measurements at a fixed distance from the tower, 7.5 m, and the other at variable distances up to 29 m away); c) use instruments with a common calibration history to minimize intercalibration uncertainties; d) monitor the calibration drift of the instruments in the field with a second generation SeaWiFS Quality Monitor (SQM-II), to separate differences in methods from changes in instrument performance; and e) compare the L W (lambda) values estimated from the above-water and in-water measurements. In addition to describing the instruments deployed and the data collected, a preliminary analysis of the data is presented, and the kind of follow-on work that is needed to completely assess the estimation of L W (lambda) from above-water and in-water measurements is discussed.

Zibordi, Giuseppe↗

Precision Lower Stratospheric Temperature Monitoring with the MSU: Technique, Validation, and Results, 1979-1991

Microwave Sounding Unit channel 4 data from the TIROS-N (Television and Infrared Operational Satellite)-N series of NOAA (National Oceanic and Atmospheric Administration) satellites are intercalibrated to provide a continuous global record of deep-layer averaged lower stratospheric temperatures during 1979-1991. A 13-year record of temperature anomalies is time averaged into pentads and months on a 2.5 deg. grid. The monthly gridpoint anomalies are validated with ten years of radiosonde data during 1979-88. The calibration stability of each satellite's measurements is evaluated during satellite overlap periods, the longest of which reveal no measurable instrumental drift at the level of 0.01 C yr (exp -1). Intercomparisons between NOAA-6 and NOAA- 7 anomalies indicate monthly gridpoint precision of 0.05 C in the tropics to around 0.10 C in the extratropics, and signal-to-noise ratios precision and stability statistics are much better than have been previously reported by other investigators for MSU channel 4. Pentad precision is about 0.10 C in the tropics to around 0.25 C at high latitudes and signal-to- noise ratios generally over 250 in the tropics and high latitudes, but 100-200 in the middle latitudes. Radiosonde comparisons to the monthly gridpoint anomalies have correlations ranging from 0.90 in the tropics (where the interannual variability is smallest) to as high as 0.99 at high-latitude stations. The corresponding standard error of estimate is generally around 0.3 C. A significant difference in decadal trends is found between the satellite and radiosonde systems, with a step change of 0.21 C (sondes cooler) compared to the satellite measurements. Investigations of the possible sources of the discrepancy lead us to suspect that the gradual transition from on-site calibration of sondes with thermometers to factory calibration of sondes around 1982 might have caused a change in the calibration, although this conclusion must be viewed as tentative. The largest globally averaged temperature variations during 1979-91 occur after the El Chichon (1982) and Pinatubo (1991) volcanic eruptions. These warm events are superimposed upon a net downward trend in temperatures during the period. This cooling trend has more of a step function than linear character, with the step occurring during the El Chichon warm event. It is strongest in polar regions and the Northern Hemisphere middle latitudes. These characteristics are qualitatively consistent with radiative adjustments expected to occur with observed ozone depletions.

Spencer, Roy W.↗

Sea WiFS Postlaunch Technical Report Series: The SeaBOARR-99 Field Campaign - Volume 8

This report documents the scientific activities during the second Sea-viewing Wide Field-of-view Sensor (Sea- WIFS) Bio-Optical Algorithm Round-Robin (SeaBOARR-99) field campaign, which took place from 2 May to 7 June 1999 on board the Royal Research Ship James Clark Ross during the eighth Atlantic Meridional Transect cruise (AMT-8). The ultimate objective of the SeaBOARR activity is to evaluate the effect of different measurement protocols on bio-optical algorithms using data from a variety of field campaigns. The SeaBOARR-99 field campaign was concerned with collecting a high quality data set of simultaneous in-water and above-water radiometric measurements. The deployment goals documented in this report were to: a) use four different surface glint correction methods to compute water-leaving radiances, Lw(lambda), from above-water data; b) use two different in-water profiling systems and three different methods to compute Lw(lambda) from in-water data; c) use instruments with a common calibration history to minimize intercalibration uncertainties; d) monitor the calibration stability of the instruments in the field with the original SeaWiFS Quality Monitor (SQM) and a commercial, second-generation device called the SQM-II, thereby allowing a distinction between differences in methods from changes in instrument performance; and e) compare the Lw(lambda) values estimated from the above- water and in- water measurements. In addition to describing the instruments deployed and the data collected, a preliminary analysis of part of the SeaBOARR-99 data set is presented (using only the data collected during clear sky, calm sea, and Case-I waters).

Hooker, Stanford B.↗

Visual-Stratigraphic Dating of the GISP2 Ice Core: Basis, Reproducibility, and Application

Annual layers are visible in the Greenland Ice Sheet Project 2 ice core from central Greenland, allowing rapid dating of the core. Changes in bubble and grain structure caused by near-surface, primarily summertime formation of hoar complexes provide the main visible annual marker in the Holocene, and changes in "cloudiness" of the ice correlated with dustiness mark Wisconsinan annual cycles; both markers are evident and have been intercalibrated in early Holocene ice. Layer counts are reproducible between different workers and for one worker at different times, with 1% error over century-length times in the Holocene. Reproducibility is typically 5% in Wisconsinan ice-age ice and decreases with increasing age and depth. Cumulative ages from visible stratigraphy are not significantly different from independent ages of prominent events for ice older than the historical record and younger than approximately 50,000 years. Visible observations are not greatly degraded by "brittle ice" or many other core-quality problems, allowing construction of long, consistently sampled time series. High accuracy requires careful study of the core by dedicated observers.

Alley, R. B.↗

Quantifying Vegetation Change in Semiarid Environments: Precision and Accuracy of Spectral Mixture Analysis and the Normalized Difference Vegetation Index

Because in situ techniques for determining vegetation abundance in semiarid regions are labor intensive, they usually are not feasible for regional analyses. Remotely sensed data provide the large spatial scale necessary, but their precision and accuracy in determining vegetation abundance and its change through time have not been quantitatively determined. In this paper, the precision and accuracy of two techniques, Spectral Mixture Analysis (SMA) and Normalized Difference Vegetation Index (NDVI) applied to Landsat TM data, are assessed quantitatively using high-precision in situ data. In Owens Valley, California we have 6 years of continuous field data (1991-1996) for 33 sites acquired concurrently with six cloudless Landsat TM images. The multitemporal remotely sensed data were coregistered to within 1 pixel, radiometrically intercalibrated using temporally invariante surface features and geolocated to within 30 m. These procedures facilitated the accurate location of field-monitoring sites within the remotely sensed data. Formal uncertainties in the registration, radiometric alignment, and modeling were determined. Results show that SMA absolute percent live cover (%LC) estimates are accurate to within ?4.0%LC and estimates of change in live cover have a precision of +/-3.8%LC. Furthermore, even when applied to areas of low vegetation cover, the SMA approach correctly determined the sense of clump, (i.e., positive or negative) in 87% of the samples. SMA results are superior to NDVI, which, although correlated with live cover, is not a quantitative measure and showed the correct sense of change in only 67%, of the samples.

Elmore, Andrew J.↗

Sources of Variability in Chlorophyll Analysis by Fluorometry and by High Performance Liquid Chromatography

The need for accurate determination of chlorophyll a (chl a) is of interest for numerous reasons. From the need for ground-truth data for remote sensing to pigment detection for laboratory experimentation, it is essential to know the accuracy of the analyses and the factors potentially contributing to variability and error. Numerous methods and instrument techniques are currently employed in the analyses of chl a. These methods range from spectrophotometric quantification, to fluorometric analysis and determination by high performance liquid chromatography. Even within the application of HPLC techniques, methods vary. Here we provide the results of a comparison among methods and provide some guidance for improving the accuracy of these analyses. These results are based on a round-robin conducted among numerous investigators, including several in the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) and HyCODE Programs. Our purpose here is not to present the full results of the laboratory intercalibration; those results will be presented elsewhere. Rather, here we highlight some of the major factors that may contribute to the variability observed. Specifically, we aim to assess the comparability of chl a analyses performed by fluorometry and HPLC, and we identify several factors in the analyses which may contribute disproportionately to this variability.

VanHeukelem, Laurie↗