Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inverter Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Generalized Wigner theorem for noninvertible symmetries

In this article, we establish the conditions under which a conservation law associated with a non-invertible operator may be realized as a symmetry in quantum physics. As established by Wigner, all quantum symmetries must be represented by either unitary or antiunitary transformations. Relinquishing an implicit assumption of invertibility, we demonstrate that the fundamental invariance of quantum transition probabilities under the application of symmetries mandates that all non-invertible symmetries may only correspond to projective unitary or antiunitary transformations, i.e., partial isometries. This extends the notion of physical states beyond conventional rays in Hilbert space to equivalence classes in an extended, gauged Hilbert space, thereby broadening the traditional understanding of symmetry transformations in quantum theory. Our generalized theorem applies irrespective of the origin of the (non)invertible symmetry, holds in arbitrary spatial dimensions, and is independent of the Hamiltonian or action. We explore its physical consequences and, using simple model systems, illustrate how the distinction between invertible and non-invertible symmetries can sometimes be tied to the choice of boundary conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

EMT data generation

The integration of inverter-based resources (IBRs) in power systems is accelerating, bringing with it significant benefits such as reduced greenhouse gas emissions, improved grid resilience, and increased energy independence. Despite these advantages, the widespread adoption of IBRs introduces several challenges, including issues related to grid stability, increased operational complexity, and the need for updated regulatory frameworks. To address these challenges, IEEE released Standard 2800 in 2022, which sets forth the necessary interconnection capabilities and performance criteria for IBRs connected to transmission and sub-transmission systems. This standard outlines the performance requirements to ensure the reliable integration of IBRs into the bulk power system. Furthermore, in 2023, the North American Electric Reliability Corporation (NERC) published a reliability guideline for electromagnetic transient (EMT) modeling of BPS-connected IBRs. This guideline provides recommendations for developing EMT model requirements, performing model quality checks, and implementing verification practices specifically for EMT models representing BPS-connected inverter-based resources in reliability studies conducted by transmission planners and planning coordinators. These standards and guidelines have a profound impact on EMT studies for transmission networks, influencing system stability analyses, grid recovery and resynchronization processes, fault ride-through evaluations, protection and coordination strategies, advanced control methodologies, and the inclusion of IBRs in transient models of transmission networks. As a result, the generation of EMT data is crucial for conducting various transient-based studies to understand the impact of IBRs. EMT data generation use cases serve as the basis for scenarios in event detection and identification use cases, providing comprehensive details about EMT data generation for transmission grids with inverter-based resources. These use cases supply sufficient training and validation datasets for subsequent EMT analysis algorithms.

Xia, Qianxue↗

Advanced Power Electronics and Electric Machines

NLR's advanced power electronics and electric machines (APEEM) research group develops world-class experimental and modeling capabilities to design and evaluate efficient and reliable power electronics and electric machines, as well as innovative thermal management systems to maximize their performance. They also design, fabricate, and characterize advanced power electronics packaging and are developing state-of-health monitoring techniques.

25 ENERGY STORAGE↗

Hybrid Symbolic-Numerical Modeling and Parametric Stability Analysis of DC–AC Power Systems

Hybrid DC-AC power systems integrating diverse inverter-based resources (IBRs) and multi-terminal high-voltage direct current (MTDC) networks represent a promising architecture for future power grids, while introducing challenges for modeling, stability analysis, and control design. This paper develops a hybrid symbolic-numerical modeling framework and tool to characterize the parametric small-signal stability of DC-AC coupled power systems. The proposed approach constructs parametric state-space models to enable efficient representation of system dynamics under varying control parameters and network configurations, with target parameters retained as symbolic variables and the remainder treated numerically. The stability analysis framework covers eigenvalue, sensitivity, and stability boundary and region characterization. Enhanced linear matrix inequality (LMI) techniques are proposed to directly certify small-signal stability over regions of parameter space while also reducing the conservativeness and computational burden. The resulting tools and frameworks enable rapid parametric model construction across diverse grid conditions, thereby facilitating stability-informed control and operation in complex DC–AC power systems.

DC–AC power systems↗

Anomalies of non-invertible symmetries in (3+1)d

Anomalies of global symmetries are important tools for understanding the dynamics of quantum systems. We investigate anomalies of non-invertible symmetries in 3+1d using 4+1d bulk topological quantum field theories given by Abelian two-form gauge theories, with a 0-form permutation symmetry. Gauging the 0-form symmetry gives the 4+1d “inflow” symmetry topological field theory for the non-invertible symmetry. We find a two levels of anomalies: (1) the bulk may fail to have an appropriate set of loop excitations which can condense to trivialize the boundary dynamics, and (2) the “Frobenius-Schur indicator” of the non-invertible symmetry (generalizing the Frobenius-Schur indicator of 1+1d fusion categories) may be incompatible with trivial boundary dynamics. As a consequence we derive conditions for non-invertible symmetries in 3+1d to be compatible with symmetric gapped phases, and invertible gapped phases. Along the way, we see that the defects characterizing \mathbb{Z}_{4} ℤ 4 ordinary symmetry host worldvolume theories with time-reversal symmetry \mathsf{T} 𝖳 obeying the algebra \mathsf{T}^{2}=C 𝖳 2 = C or \mathsf{T}^{2}=(-1)^{F}C, 𝖳 2 = ( − 1 ) F C , with C C a unitary charge conjugation symmetry. We classify the anomalies of this symmetry algebra in 2+1d and further use these ideas to construct 2+1d topological orders with non-invertible time-reversal symmetry that permutes anyons. As a concrete realization of our general discussion, we construct new lattice Hamiltonian models in 3+1d with non-invertible symmetry, and constrain their dynamics.

Córdova, Clay↗

Direct Power Control of Back to Back Modular Multilevel Converter with Advanced Grid Support Functions for Grid Forming Application

Possibility of using back-to-back modular multilevel converter system with a direct power control architecture has been investigated in this paper. The rectifier side is controlled to be in grid following mode whereas the inverter side is controlled in grid forming mode. Both the sides’ local controllers use Lyapunov energy function based architecture to accomplish the objective of active and reactive power control as well as maintaining a fixed user defined voltage over the dc bus on the rectifier side. Therefore, the proposed direct power control architecture has embedded dc bus control architecture to maintain fixed user defined value of the capacitors. Similar architecture is implemented on the inverter side to accomplish either voltage control during grid forming or power control during grid following. Advanced grid support functionalities based on IEEE-1547-2018 is implemented and utilized to generate the reference values for either the rectifier or the inverter sides. The overall system is modeled based on MATLAB/Simulink and PLECS domain and various important case studies to verify the efficacy of the overall system has been presented.

direct power control (DPC)↗

RE-INTEGRATE EMT Simulation Software: Graph Convolutional Network for Sparse Matrix Pattern Detection

The increasing complexity of power networks, driven by proliferation of inverters, presents analytical challenges that simplified models often fail to capture, necessitating Electromagnetic Transient (EMT) simulations. EMT models are represented as discretized differential-algebraic equations (DAEs), forming a linear system Ax = b that is computationally intensive to solve. Due to inherent sparsity of adjacency matrix A, distinct patterns emerge that, when accurately identified, enable efficient solver selection to minimize computation time. However, identifying ideal pattern is complicated by numerous reordering algorithms and limited structural insights. To address this, we introduce a Graph Convolutional Network (GCN) model for classifying sparse matrix patterns common in power system analysis. The model, achieving 96% test accuracy, is validated using PV plant models of 125 MW capacities connected to New England 39-bus transmission system (TS), and further scaled to a 4,992-bus network with 384 PV plants, yielding 191, 616 × 191, 616 sized A matrix. For all cases, the GCN model accurately identifies the matrix’s intrinsic sparse pattern, demonstrating its potential to enhance solver performance in EMT analysis.

Hossain, Md Rifat [Florida International Universit↗

Integration and Validation of Multi-Layer Mitigation Strategies for Cyber Physical Systems Resilience (RD2C Capstone I Project) (Technical Report)

This project demonstrated the effectiveness of RD2C-developed, resilience-driven control strategies on high-fidelity system models with high penetrations of inverter-based resources, under the impacts of unexpected natural events and cyber-physical attacks. Controller performance and overall system resilience were quantified using data from a comprehensive suite of scenarios, and provided a clear understanding on how to operate and deploy these mitigation strategies.

42 ENGINEERING↗

ComStock Measure Documentation: Photovoltaics With 40% Rooftop Coverage

This study investigates the impact of adding 40% rooftop coverage of photovoltaics to the U.S. commercial building stock. Panels are modeled as higher performance with 21% rated efficiency, 96% inverter efficiency, 1.10 DC/AC ratio,14% system losses, and azimuth/tilt angles that vary by location. Total panel area is modeled at 40% of the roof area for each model. Total rated PV power for a building is based on the calculated total panel area and the assumed efficiency of 21%. This measure is applied to all buildings modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extending Component Lifetime And Improving Inverter Reliability (ECLAIIR)

Inverter reliability remains one of the most persistent challenges limiting the performance, availability, and economic viability of utility‑scale photovoltaic (PV) plants. Industry data consistently show that inverters account for the highest share of corrective maintenance events and unplanned outages across PV fleets. These failures result in energy losses, increased O&M costs, and reduced confidence in long‑term solar asset performance. Motivated by these challenges, this project—Extending Component Lifetime and Improving Inverter Reliability (ECLAIIR)—was undertaken to systematically investigate inverter degradation and failure mechanisms, develop predictive maintenance capabilities, and establish data‑driven pathways to improve service life and reduce the Levelized Cost of Energy (LCOE) for large‑scale PV systems. The primary goal of the project was to identify pre‑failure signatures in string inverters using both lab‑based accelerated lifetime testing and field‑based data and to develop predictive maintenance algorithms that can anticipate inverter faults before they occur. Through collaboration with inverter testing laboratory, solar PV plant owner, and failure‑analysis experts, the project advanced the technical understanding of inverter reliability. By instrumenting inverters with thermistors, humidity sensors, power‑quality meters, and acoustic sensors, the research established how multiple sensing modalities can reliably detect deviations from normal behavior hours to days before failure. These findings substantially enhance scientific understanding of inverter failure kinetics and provide the PV industry with the most comprehensive cross‑OEM characterization of early‑stage failure indicators reported to date. Technically, the project demonstrated the effectiveness of predictive maintenance by developing and validating the PreDICT (Predictive Diagnostics of PV Inverters Using Condition Monitoring and Trend Analysis) framework—a multi‑layer diagnostic architecture combining peer‑to‑peer analytics, historical trend modeling, and advanced machine‑learning techniques such as the Sequential Conditional Variational Autoencoder (SCVAE). This predictive model achieved more than 90% accuracy in detecting pre‑failure conditions and provided up to four days of lead time before inverter failure in field scenarios. Economically, the project’s LCOE analysis showed that predictive maintenance can reduce lifetime energy losses and minimize corrective maintenance interventions. Modeling indicated that, depending on inverter failure rates and replacement timelines, predictive maintenance can significantly reduce LCOE impacts associated with inverter downtime: from as high as 19.4% under conventional maintenance strategies to 0.1%–10.17% when predictive analytics are adopted. These results confirm that predictive maintenance is both technically feasible and economically advantageous for utilities and plant operators. The project’s findings also have broad public benefit. By improving inverter reliability and reducing downtime, predictive maintenance directly increases electricity generation from existing PV assets. Enhanced reliability lowers operational costs for utilities, which can translate over time into lower energy costs for consumers. Furthermore, the project’s technical publications, conference presentations, and industry workshops ensure that knowledge gained is shared broadly across the solar industry, supporting workforce development and enabling utilities of all sizes to adopt modern asset‑health monitoring practices. The retrofitting case study and service‑life prediction framework further support informed decision‑making for aging PV fleets, helping operators extend system life and reduce electronic waste. In summary, the ECLAIIR project significantly advanced the state of knowledge on inverter degradation, demonstrated the technical and economic value of predictive maintenance, and delivered actionable tools and insights that support more reliable, cost‑effective, and sustainable PV plant operation. The outcomes of this project will continue to inform utility practices, guide inverter design improvements, and strengthen the long‑term performance of solar assets nationwide.

14 SOLAR ENERGY↗

Quantifying uncertainty in regional-scale seismic moment tensors

We examine the ability of three different inversion methods: 1) first motion (FM) inversions, 2) amplitude inversions, and 3) full waveform (FW) time variable moment tensor (TVMT) inversions, to recover an accurate source mechanism for simulated data for an earthquake as well as an explosion. The ability of inversion methods, such as the ones described above, to recover accurate models representative of the data depends on both a priori information as well as the quality of data being inverted. Therefore, we examine the effect that station geometry, geologic model, and noise level has on the inversion and estimated source mechanism. We find that FM data can provide more robust solutions than amplitude data and are not as sensitive to inaccurate earth models, especially in low-noise cases, and overall FW inversions are the most accurate out of the methods examined, but can still be biased by inaccurate earth models.

58 GEOSCIENCES↗

Equivalent-Circuit Models of Grid-Forming IBRs for Electromagnetic-Transient Simulations

We derive equivalent-circuit models of control- and physical-layer subsystems of grid-forming (GFM) inverter-based resources (IBRs) for electromagnetic-transient (EMT) simulations. Three different primary controllers are considered: Droop, Virtual Synchronous Machine (VSM), and dispatchable Virtual Oscillator Control (dVOC). In addition, the models include cascaded voltage- and current-control loops, and LCL output filters. Simulations for a single-inverter setup and for a network of five inverters in a modified IEEE 14-bus topology are presented. The equivalent-circuit models simulated with analog electronic circuit-simulator software (in our case, LTspice) offer the same accuracy, and with no explicit tuning of the solver, lower computational burden compared to block-diagram-based implementations in commercial off-the-shelf EMT software (in our case, MATLAB-Simulink).

electromagnetic transient simulation↗

Equivalent-Circuit Models of Grid-Forming IBRs for Electromagnetic-Transient Simulations: Preprint

We derive equivalent-circuit models of control- and physical-layer subsystems of grid-forming (GFM) inverter-based resources (IBRs) for electromagnetic-transient (EMT) simulations. Three different primary controllers are considered: droop, virtual synchronous machine (VSM), and dispatchable virtual oscillator control (dVOC). In addition, the models include cascaded voltage- and current-control loops, and LCL output filters. Simulations for a single-inverter setup and for a network of five inverters in a modified IEEE 14-bus topology are presented. The equivalent-circuit models simulated with analog electronic circuit-simulator software (in our case, LTspice) offer the same accuracy with up to 150x lower computational burden compared to block-diagram-based implementations in commercial off-the-shelf EMT software (in our case, MATLAB-Simulink).

circuit-equivalent model↗

Scheduler Modeling of IBR Plants for Providing Ancillary Services [SWR-25-16]

Inverter-based resources (IBRs) have been integral components of modern power systems and their capability in providing grid services have been widely studied. To promote the deployment of IBR grid services in real utility operation, this software proposes a scheduler model for IBRs. The energy and reserve are co-optimized in day-ahead, various ancillary services, including operating reserve provision, peak load reduction, voltage regulation and power factor control are integrated in the model.

Wang, Xiaofei [National Renewable Energy Laborator↗

Testing the Froggatt-Nielsen mechanism with lepton flavor and number violating processes

The Froggatt-Nielsen (FN) mechanism offers an elegant explanation for the observed masses and mixings of Standard Model fermions. In this work, we systematically study FN models in the lepton sector, identifying a broad range of charge assignments (“textures”) that naturally yield viable masses and mixings for various neutrino mass generation mechanisms. Using these textures, we consider higher-dimensional operators consistent with a FN origin and find that natural realizations predict distinct patterns in lepton flavor- and number-violating observables. For Dirac and Majorana neutrinos, FN-related correlations can lead to detectable rates of charged lepton flavor violation at next-generation low-energy experiments. Majorana and type-I seesaw models predict measurable rates of neutrinoless double beta decay. Determination of inverted neutrino mass ordering would exclude the Dirac neutrino FN scenario. Only a small minority of purely leptonic FN models predict detectable flavor violation at future muon colliders, though it is possible that a combined analysis with the quark sector will reveal motivated signals. These findings highlight the power of the FN mechanism to link neutrino mass generation to testable leptonic observables, offering new pathways for the experimental exploration of lepton number and underscoring the importance of next-generation low-energy probes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Grey-Box System Identification of Grid-Forming Inverters

This paper demonstrates the use of grey-box system identification methods for simplifying and understanding the nonlinear power dynamics of grid-forming inverters (GFMs). The power and frequency outputs of complex high-order GFM models are fed into system identification software in order to fit them to a predetermined LTI system and learn system parameters such as (synthetic) inertia and droop constants. The same process is then run for a high-order synchronous generator model, and the outputs are fit to the same set of LTI equations. Simulation of a network of GFM inverters with diverse control architecture is also performed for the same process. The intent is threefold: first, to demonstrate the appropriateness of unified LTI models for describing the power and frequency dynamics of individual resources and connected networks, in order to facilitate analysis of larger heterogeneous networked systems; second, to discover the relationship between internal control parameters of GFMs and their externally observed values; and third, to validate that grey-box data-driven system identification techniques can be a valuable tool to discover the values of important parameters in the absence of explicit vendor models.

analytical models↗