Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ions Separations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Measurements of ion velocity separation and ionization in multi-species plasma shocks

The ion velocity structure of a strong collisional shock front in a plasma with multiple ion species is directly probed in laser-driven shock-tube experiments. Thomson scattering of a 263.25 nm probe beam is used to diagnose ion composition, temperature, and flow velocity in strong shocks (M ~ 6) propagating through low-density (ρ ~ 0.1 mg/cc) plasmas composed of mixtures of hydrogen (98%) and neon (2%). Within the preheat region of the shock front, two velocity populations of ions are observed, a characteristic feature of strong plasma shocks. The ionization state of the Ne is observed to change within the shock front, demonstrating an ionization-timescale effect on the shock front structure. In conclusion, the forward-streaming proton feature is shown to be unexpectedly cool compared to predictions from ion Fokker-Planck simulations; the neon ionization gradient is evaluated as a possible cause.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rapid and Simultaneous Characterization of Drug Conjugation in Heavy and Light Chains of a Monoclonal Antibody Revealed by High-Resolution Ion Mobility Separations in SLIM

Antibody-drug conjugates (ADCs) have recently gained traction in the biomedical community due to their promise for human therapeutics and an alternative to chemotherapy for cancer. Crucial metrics for ADC efficacy, safety, and selectivity are their drug-antibody ratios (DARs). However, DAR characterization (i.e., determining the average number of conjugated drugs on the antibody) through analytical methods remains challenging due to the heterogeneity of drug conjugation as well as the numerous post-translational modifications possible in the monoclonal antibody. In this work, we report on the use of high-resolution ion mobility spectrometry separations in our structures for lossless ion manipulations coupled to mass spectrometry (SLIM IMS-MS) platform for the rapid and simultaneous characterization of the drug load profile (i.e., stoichiometric distribution of the number of conjugated drugs present on the mAb), determination of the weighted average DAR in both the heavy and light chains of a model antibody-drug conjugate, and calculation of the overall DAR of the ADC. After chemical reduction of the ADC and a subsequent 31.5 meter SLIM IMS separation the various drug bound antibody species could be well resolved for both chains. Furthermore, we also show that higher resolution separations were possible with SLIM IMS as compared to ones performed on a commercially available (~1 meter) drift tube IMS-MS platform. Interestingly, additional gas-phase substructures become evident with longer path length SLIM IMS, potentially providing insight related to how drug conjugation may alter the structural properties of a monoclonal antibody and thus affect its overall potency and/or selectivity for a given antigen. We expect high-resolution SLIM IMS separations will augment the existing toolbox for ADC characterization, particularly for structural confirmation to enable the rapid optimization of DAR for a given ADC and thus better understand its potential toxicity and potency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fast ground-state-to-ground-state separation of small ion crystals

Rapid separation of linear crystals of trapped ions into different subsets is critical for realizing trapped ion quantum computing architectures where ions are rearranged in trap arrays to achieve all-to-all connectivity between qubits. Here we introduce a general theoretical framework that can be used to describe the separation of same-species and mixed-species crystals into smaller subsets. The framework relies on an efficient description of the evolution of Gaussian motional states under quadratic Hamiltonians that only requires a special solution of the classical equations of motion of the ions to describe their quantum evolution under the influence of a time-dependent applied potential and the ions' mutual Coulomb repulsion. We provide time-dependent applied potentials suitable for separation of a mixed-species three-ion crystal on timescales similar to that of free expansion driven by Coulomb repulsion, with all modes along the crystal axis starting and ending close to their ground states. Three separately confined mixed-species ions can be combined into a crystal held in a single well without energy gain by time-reversal of this separation process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ion Mobility Separation of Isomeric Phosphopeptides from a Protein with Variant Modification of Adjacent Residues

Ion mobility spectrometry (IMS), and particularly differential IMS or field asymmetric waveform IMS (FAIMS), was recently shown capable of separating post-translationally modified peptides with variant PTM localization. However, that work was limited to a model peptide with serine phosphorylation on fairly distant alternative sites. Here, we demonstrate that FAIMS (coupled to ESI/MS) can broadly baseline-resolve variant phosphopeptides from a biologically modified human protein, including those involving phosphorylation of different residues and adjacent sites that existing MS/MS methods are most challenged to distinguish. Singly and doubly phosphorylated variants can be resolved equally well and identified without dissociation, based on accurate separation properties. The results are unchanged over a range of infusion solvent pH, hence present approach should work in conjunction with chromatographic separations using a mobile phase gradient.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion Mobility Separation of Variant Histone Tails Extending to the “Middle-down” Range

Differential ion mobility spectrometry (FAIMS) can baseline-resolve multiple variants of post-translationally modified peptides extending to the 3 - 4 kDa range, which differ in the localization of a PTM as small as acetylation. Essentially orthogonal separations for different charge states expand the total achievable peak capacity in proportion to the number of observed states that increases for longer polypeptides. This might enable resolving localization variants for even larger peptides and intact proteins.

59 BASIC BIOLOGICAL SCIENCES↗

Automation of Extraction Chromatograhic and Ion Exchange Separations for Radiochemical Analysis and Monitoring

Radiochemical analysis, complete with the separation of radionuclides of interest from the sample matrix and from other interfering radionuclides, is often an essential step in the determination of the radiochemical composition of a nuclear sample or process stream. Although some radionuclides can be determined nondestructively by gamma spectroscopy, where the gamma rays penetrate significant distances in condensed media and the gamma ray energies are diagnostic for specific radionuclides, other radionuclides that may be of interest emit only alpha or beta particles. For these, samples must be taken for destructive analysis and radiochemical separations are required. For process monitoring purposes, the radiochemical separation and detection methods must be rapid so that the results will be timely. These results could be obtained by laboratory analysis or by radiochemical process analyzers operating on-line or at-site. In either case, there is a need for automated radiochemical analysis methods to provide speed, throughput, safety, and consistent analytical protocols. Classical methods of separation used during the development of nuclear technologies, namely manual precipitations, solvent extractions, and ion exchange, are slow and labor intensive. Fortunately, the convergence of digital instrumentation for preprogrammed fluid manipulation and the development of new separation materials for column-based isolation of radionuclides has enabled the development of automated radiochemical analysis methodology. The primary means for separating radionuclides in solution are liquid-liquid extraction and ion exchange. These processes are well known and have been reviewed in the past.1 Ion exchange is readily employed in column formats. Liquid-liquid extraction can also be implemented on column formats using solvent-impregnated resins as extraction chromatographic materials. The organic liquid extractant is immobilized in the pores of a microporous polymer material. Under suitable conditions, the analyte of interest partitions into the immobilized organic phase while other matrix speces and interferences are washed away in the mobile aqueous phase. After the wash step, retained analytes are rapidly released in one or more steps by changing the aqueous eluent, such that the analytes now partition back into the mobile phase. The development of solvent impregnated resins, their physical chemistry, technological applications for metal and radionuclide recovery, and analytical uses were described in detail in a previous chapter in this series by Cortina and Warshawsky. The extraction chromatographic approach is well suited for the isolation of radionuclides from complex sample matrixes in a rapid automated format. The development of automated radioanalytical methods is, in fact, closely coupled to the availability of such materials. In this review, we will focus on the application of radiochemical separations in automated fluidic formats for the analysis of alpha- and beta-emitting radionuclides.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

High-Resolution Differential Ion Mobility Separations Using Planar Analyzers at Elevated Dispersion Fields

Analyses of complex or isomeric mixtures increasingly involve ion mobility spectrometry/ mass spectrometry (IMS/MS). The IMS methods are grouped into conventional, based on the absolute ion mobility, and differential or field asymmetric waveform IMS (FAIMS), based on the mobility difference in strong and weak electric fields. The key attraction of FAIMS is substantial orthogonality to MS, and several FAIMS/MS platforms have been commercialized. However, the utility of FAIMS had been constrained by limited resolving power, typically R ~ 10 - 20. Recently, the use of helium/nitrogen mixtures comprising up to 75% He has enabled R > 100, with broad resolution gains allowing separation of previously “co-eluting” isomers. These performance metrics open major new FAIMS applications in proteomic and other biological analyses. Here, we show that raising the separation field by ~35% over the previous 21 kV/cm provides similar or better resolution at 50% He, while avoiding problems due to elevated gas pressure in the MS manifold upon excessive He intake. In particular, a resolving power of >200 has been achieved for multiply-charged peptides. The field heating of ions under these conditions appears to exceed that at higher He content but weaker separation field, inducing greater izomerization of fragile species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental Findings On Minor Actinide And Lanthanide Separations Using Ion Exchange

This project seeks to determine if inorganic or hybrid inorganic ion-exchange materials can be exploited to provide effective americium and curium separations. Specifically, we seek to understand the fundamental structural and chemical factors responsible for the selectivity of the tested ion-exchange materials for actinide and lanthanide ions. During FY13, experimental work focused in the following areas: (1) investigating methods to oxidize americium in dilute nitric acid with subsequent ion-exchange performance measurements of ion exchangers with the oxidized americium and (2) synthesis, characterization and testing of ion-exchange materials. Ion-exchange materials tested included alkali titanates, alkali titanosilicates, carbon nanotubes and group(IV) metal phosphonates. Americium oxidation testing sought to determine the influence that other redox active components may have on the oxidation of Am(III).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Compression Ratio Ion Mobility Programming (CRIMP) Accumulation and Compression of Billions of Ions for Ion Mobility-Mass Spectrometry Using Traveling Waves in Structures for Lossless Ion Manipulations (SLIM)

We report on the implementation of a traveling wave (TW) based compression ratio ion mobility programming (CRIMP) approach within Structures for Lossless Ion Manipulations (SLIM) that enables both greatly enlarged trapped ion charge capacities and also their subsequent efficient compression for use in ion mobility (IM) separations. Ion accumulation is conducted in a long serpentine path TW SLIM region after which CRIMP allows the large ion populations to be ‘squeezed’. The compression process occurs at an interface between two SLIM regions, one operating conventionally and the second having an intermittently pausing or ‘stuttering’ TW, allowing the contents of multiple bins of ions from the first region to be merged into a single bin in the second region. In this initial work stationary voltages in the second region were used to block ions from exiting the first (trapping) region, and the resumption of TWs in the second region allows ions to exit, and the population to also be compressed if CRIMP is applied. In our initial evaluation we show that the number of charges trapped for a 40 s accumulation period was ~5×109, more than two orders of magnitude greater than the previously reported charge capacity using an ion funnel trap. We also show that over 1×109 ions can be accumulated with high efficiency in the present device, and that the extent of subsequent compression is only limited by the space charge capacity of the trapping region. Lower compression ratios allow increased IM peak heights without significant loss of signal, while excessively large compression ratios can lead to ion losses and other artifacts. Importantly, we show that extended ion accumulation in conjunction with CRIMP and multiple passes provides the basis for a highly desirable combination of ultra-high sensitivity and ultra-high resolution IM separations using SLIM.

Environmental Molecular Sciences Laboratory↗

High resolution mobility spectrometry in a co-axial platform

Ion mobility spectrometry is an analytical technique that separate ions in the gas phase based on their interaction with a neutral buffer gas. Ion mobility spectrometry performs separations quickly (typically less than a second) and the ion mobilities are very reproducible across different laboratories. This project aimed at evaluating the performance of a new ion mobility device. The new device relies on conducting ion mobility separation in a curved geometry. The project explored the operation landscape of the device using ion trajectory simulations then fabricated and experimentally demonstrated the device's performance. Ion trajectory simulations on a set of tetraalkylammonium and phosphazene ions indicate that ions traveling a curved path length undergo mobility separation that is similar to a straight path. The ion mobility resolution of the curved device was found to be similar to that of a straight path of a similar length. The experimental validation of the new device confirmed the device's ability to separate ions according to their mobilities. Sets of mixtures (tetraalkylammonium ions, phosphazene ions, and peptide ions) were evaluated for separation and transmission.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantification techniques of mass-separation and ion yield for the detection of radioactive isotopes

This research demonstrates two methods of quantifying isotope separation efficiency using an inductively coupled plasma mass spectrometer. One method measured the accumulated charge on a conductive collection substrate in real-time while the second method performed a chemical dissolution of the substrate with subsequent post-processing and analysis. Our previous results demonstrated and compared these methods with a multi-element standard of stable isotopes. This research applies these methods to quantifying radioactive isotopes utilizing measurements of the stable isotope at the same mass-to-charge ratio. The mass-separated radioactive isotope were fission products produced from thermal neutron irradiation of a highly enriched 235U foil. The two methods are explained and the results of this new separation methodology are compared to available cumulative fission yields.

Dion, Michael P.↗

Highly Selective Current-Induced Accumulation of Trace Ions at Micro-/NanoPorous Interfaces

During application of an electrical current through a composite micro-/nano-porous membrane, trace-ion accumulation in the microporous layer should vary greatly with the ion diffusion coefficient to allow selective accumulation of specific ions. In this study, we examine the theoretical enrichment factors in the microporous region as a function of current density and trace-ion diffusion coefficient to demonstrate the promise of such micro-/nano-porous interfaces for ion separations. Trace-ion accumulation relies on charged nanopores that exclude coions (ions with the same charge as the nanopore walls)and give rise (under current) to depletion of the dominant (high-concentration) salt in the region next to the nanopores. This depletion gives rise to high local electric fields. Trace ions accumulate in this region because convection carries them toward the nanoporous interface, whereas electromigration in the opposite direction is strongest next to the interface. For ions whose diffusion coefficients are half of the corresponding value for the dominant salt, calculated enrichment factors reach 150. In contrast depletion occurs for ions with the same diffusion coefficient as the dominant salt. Even higher enrichment factors appear for divalent ions due to their relatively low diffusion coefficients. Lastly, with monovalent coions whose diffusion coefficients differ by only 2%, calculated selectivity factors reach values >1.2 (>1.8 for divalent coions), depending on the magnitudes of the diffusion coefficients. Such selectivities may prove useful in separating very similar species such as isotopes or equally charged peptides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of Confinement and Zwitterionic Ligand Chemistry on Ion–Ion Selectivity of Functionalized Nanopores

Membranes incorporating zwitterionic chemistries have recently emerged as promising candidates for facilitating challenging ion–ion separations. Transport of ions in such membranes predominantly occurs in hydrated nanopores lined with zwitterionic monomers. Here, to shed light on the physics of ion–ion selectivity underlying such materials, we conducted molecular dynamics simulations of sodium halide transport in model nanopores grafted with sulfobetaine methacrylate molecules. Our results reveal that in both functionalized and unfunctionalized nanopores smaller ions prefer to reside near the pore center, while the larger ions tend to reside near the pore walls. An enhancement in the selective transport of larger anions is observed within the unfunctionalized nanopores relative to that in salt-in-water solutions. Upon functionalization of the nanopores with zwitterions (ZIs), the disparities in the anionic distribution profiles within the pores coupled with differences in the anion-ZI interactions result in a slowdown of larger anions relative to smaller anions. Increasing the ZI grafting density exacerbates these effects, further promoting the selective transport of smaller anions. Our results suggest that selectivity toward large anions can be realized by using nanoporous membranes with ZI content that is high enough to facilitate ion/water partitioning into the pores while preserving the characteristic tendency of the unfunctionalized pores to facilitate faster transport of the larger anions. On the other hand, selectivity toward smaller anions can be achieved by targeting ZI content within the pores that is high enough to significantly slow down the transport of large anions but not high enough to hinder the partitioning of ions/water molecules into the pore due to steric effects.

anions↗

Energy transfer from Tb{sup 3+} to Eu{sup 2+} in Ga{sub 2}S{sub 3}:(Eu{sup 2+}, Tb{sup 3+}) crystals

The photoluminescence of Ga{sub 2}S{sub 3} crystals activated with Eu{sup 2+} and Tb{sup 3+} ions separately and with ions of both types is studied in the temperature range 77–300 K. It is established that, in the range 77–300 K, the observed broadband photoluminescence in (Ga{sub 2}S{sub 3}){sub 0.95}:(Eu{sub 2}O{sub 3}){sub 0.05} crystals with a peak at 545 nm is defined by 4f{sup 6}5d-4f{sup 7}({sup 8}S{sub 7/2}) intracenter transitions in Eu{sup 2+} ions and the photoluminescence with peaks at 492, 544, 584, 625, and 680 nm in (Ga{sub 2}S{sub 3}){sub 0.99}(Tb{sub 2}O{sub 3}){sub 0.01} crystals is due to the 5d → {sup 2}F{sub j} (j = 6−2) intracenter transitions in Tb{sup 3+} ions. It is shown that the photoluminescence bands of Tb{sup 3+} ions in the (Ga{sub 2}S{sub 3}){sub 0.94}(Eu{sub 2}O{sub 3}){sub 0.05}(Tb{sub 2}O{sub 3}){sub 0.01} crystals disappears because of excitation energy transfer from Tb{sup 3+} ions to Eu{sup 2+} ions; i.e., the Tb{sup 3+} ion is a sensitizer of the photoluminescence of the Eu{sup 2+} ion.

36 MATERIALS SCIENCE↗

Preactivated zeolite nanosheet plate-tiled membrane on porous PVDF film: Synthesis and study of proton-selective ion conduction

Preactivated MFI zeolite nanosheet plates (ZNPs) with large areas (~2.0 × 2.0 μm 2 ) and nanometer thicknesses (~60 nm) were prepared directly in liquid-dispersed state. The individual ZNP was a stack of 4-nm-thick single crystalline zeolite nanosheets (ZNs) interlinked by Si–O–Si bonds between neighboring ZN surfaces. The dispersed open-pore ZNPs allowed formulating suspensions for tiling ZNP membranes on polymer substrates without requiring post-coating activation. A pinhole-free ZNP-tiled (ZNPT) membrane has been achieved on macroporous PVDF film by a self-repairing vacuum-assisted filtration coating method. The resultant ZNPT layer was ~500 nm-thick consisting of about 7 ZNP layers with inter-ZNP width and inter-ZNP entrance porosity around 9 nm and 2%, respectively. The ZNPT-PVDF membrane exhibited high selectivity to proton transport over vanadyl ion and low resistances to proton conduction in aqueous solutions. The membrane also demonstrated to function as an efficient ion separator for the vanadium redox flow battery. The reported synthesis of preactivated ZNP suspension may overcome the major hurdle to realizing polymer-supported ZN membranes, which is the inefficiency of existing methods in obtaining readily dispersible open-pore ZNs. Finally, the ZNPT-PVDF membrane can be a more affordable and sustainable alternative to the Nafion-based ion separation membranes.

36 MATERIALS SCIENCE↗

Isotopic Effect on Ion Mobility and Separation of Isotopomers by High-Field Ion Mobility Spectrometry

Since early 1900-s, when vacuum techniques and ion detectors first enabled investigations of gas-phase ions, two approaches to their separation and characterization have emerged - mass spectrometry (MS) and ion mobility spectrometry (IMS).1,2 Though both exploit that distinct charged species move in electric fields differently, MS is performed in vacuum and is based only on the ion mass/charge (m/q) ratio while IMS involves sufficiently dense buffer gases and relies on ion transport properties. The first major discovery enabled by MS was the existence of isotopes by Thomson and Aston,3 and isotopic analyses have since been integral to MS. In particular, the preparative separation of U isotopes using Lawrence’s Calutron was the first industrial application of MS,4 and isotopic labeling is key to MS quantification methods. With IMS, the issue of isotopes was largely ignored as the resolving power (R) was generally too low for their separation. Here, we demonstrate that recently developed high-resolution differential IMS can separate isotopic molecular ions, including nominal isobars with different isotopic content and isotopomers. This capability may enable a new method for isotope separation in a small-scale format at ambient pressure and aid localization of labeled sites in various molecules. Perhaps most importantly, the isotopic shifts depend on the labeled atom position and thus may contain the kind of detailed structural information that is available in solution or solid state using tools such as NMR but has not generally been obtainable for gas-phase ions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Differential Ion Mobility Separations in up to 100% Helium Using Microchips

The performance of differential IMS (FAIMS) analyzers is much enhanced by gases comprising He, especially He/N2 buffers. However, electrical breakdown has limited the He fraction in those mixtures to ~50 - 75%, depending on the field strength. By Paschen law, the threshold field for breakdown increases at shorter distances. This allows FAIMS using chips with microscopic channels to utilize much stronger field intensities (E) than “full-size” analyzers with wider gaps. Here we show that those chips can employ higher He fractions up to 100%. Use of He-rich gases improves the resolution and resolution/sensitivity balance substantially, although less than for full-size analyzers. The optimum He fraction is ~80%, in line with first-principles theory. Hence one can now measure the dependences of ion mobility on E in pure He, where ion-molecule cross section calculations are much more tractable than in other gases that form deeper and more complex interaction potentials. This capability may facilitate quantitative modeling of high-field ion mobility behavior and thus FAIMS separation properties, which would enable a priori extraction of structural information about the ions from FAIMS data.

Environmental Molecular Sciences Laboratory↗

Pushing the Frontier of High-Definition Ion Mobility Spectrometry Using FAIMS

Differential ion mobility spectrometry (FAIMS) separates ions in gases based on the difference between their mobilities in strong and weak electric fields, captured directly employing a periodic waveform with dissimilar profiles in opposite polarities. As that difference is not tightly correlated with the ion size or mass, FAIMS separations are generally quite orthogonal to both conventional IMS (based on the absolute ion mobility that reflects the physical ion size) and mass spectrometry (based on mass). Until a few years ago, that advantage was largely offset by poor FAIMS resolving power (~10–20), an order of magnitude below that achieved with conventional (drift-tube) IMS. This article summarizes the major recent technical developments that have raised FAIMS resolving power up to ~500. These include use of higher and more stable voltages provided by new waveform generators, novel buffer gas compositions comprising high helium or hydrogen fractions, and extended filtering times up to ~1 s. These advances have enabled previously unthinkable analyses such as broad baseline separations of peptide sequence inversions, localization variants (post-translationally modified peptides with differing PTM attachment sites) even for the larger “middle-down” peptides and smallest PTMs, and lipid regioisomers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗