Search NASA⌕ Search

SEARCH · Search NASA

Results for “Isotope Ratio Mass Spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Characterizing the Uncertainty of Measurement of Traceable Isotope Ratios with Bayesian Statistical Techniques

Analytical techniques such as multicollector—inductively coupled plasma—mass spectrometry (MC-ICP-MS) are routinely employed at SRNL, other National Laboratories, and in academia to determine the precise isotopic composition of diverse natural and anthropogenic samples (e.g., rocks and nuclear materials). Quantifying and reporting uncertainty in such analyses, while regularly performed, have a rigorous statistical foundation. The Guide to the Expression of Uncertainty in Measurement 4 (GUM) outlines conventional techniques used to assess such uncertainty. As the accessibility and speed of statistical computing increase, there is a need to modernize conventional techniques. For example, Supplement 1 to the 3rd to the GUM suggests the use of approximation methods as an updated approach to the GUM.

McLarty, Ellis C.↗

Position-Specific Carbon Isotope Fingerprinting of Fluorinated Organics and Degradation Products

Fluorinated organic compounds are of growing environmental and forensic relevance due to their widespread use in pharmaceuticals, agrochemicals, and consumer products, their environmental persistence, and potential ecological and human health impacts. Elucidating their sources and transformation pathways is therefore a major focus of current research. Stable carbon isotope analysis provides a powerful approach for tracing molecular origins and linking parent compounds to degradation products. Recent isotope measurements have largely relied on mass-spectrometry techniques, which provide only an average isotope ratio across a compound. In this work, we employ a novel nuclear magnetic resonance (NMR) spectroscopy tool to determine position-specific carbon isotope ratios ( 13 C/ 12 C) in organofluorine compounds and their degradation products. This approach enables isotope measurements without combustion or extensive purification and, crucially, resolves ratios at individual carbon positions rather than bulk averages. The resulting intramolecular isotope fingerprints are unique to a molecule’s source. Applied to selected pharmaceuticals and pesticides, these fingerprints allow discrimination of chemically identical compounds. Moreover, we show that the 13 C/ 12 C signature at the fluorinated carbon persists through degradation, demonstrated for lansoprazole and fipronil. The 19 F NMR data produced for the 13 C/ 12 C analyses are also well suited for impurity profiling, providing an additional dimension for fingerprinting fluorinated organics. These findings suggest that position-specific isotope analysis can serve as part of a broader suite of tools for source characterization of organofluorine compounds and their breakdown derivatives, with potential applications in product validation, forensics, and linking these compounds to their breakdown products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Position-specific carbon isotope analysis of serine by gas chromatography/Orbitrap mass spectrometry, and an application to plant metabolism

Position-specific 13 C/ 12 C ratios within amino acids remain largely unexplored in environmental samples due to methodological limitations. We hypothesized that natural-abundance isotope patterns in serine may serve as a proxy for plant metabolic fluxes including photorespiration. Here we describe an Orbitrap method optimized for the position-specific carbon isotope analysis of serine to test our hypothesis and discuss the generalizability of this method to other amino acids. Position-specific carbon isotope ratios of serine were measured using a Thermo Scientific™ Q Exactive™ GC Orbitrap™. Amino acids were hydrolyzed from Arabidopsis biomass, purified from potential matrix interferences, and derivatized alongside standards. Derivatized serine (N,O-bis(trifluoroacetyl)methyl ester) was isolated using gas chromatography, trapped in a reservoir, and purged into the electron ionization source over tens of minutes, producing fragment ions containing different combinations of atoms from the serine-derivative molecule. The 13 C/ 12 C ratios of fragments with monoisotopic masses of 110.0217, 138.0166, and 165.0037 Da were monitored in the mass analyzer and used to calculate position-specific δ 13 C values relative to a working standard. This methodology constrains position-specific δ 13 C values for nanomole amounts of serine isolated from chemically complex mixtures. The δ 13 C values of fragment ions of serine were characterized with ≤1‰ precisions, leading to propagated standard errors of 0.7–5‰ for each carbon position. Position-specific δ 13 C values differed by up to ca 28 ± 5‰ between serine molecules hydrolyzed from plants grown under contrasting pCO 2 , selected to promote different fluxes through photosynthesis and photorespiration. The method was validated using pure serine standards characterized offline. Here this study presents the first Orbitrap-based measurements of natural-abundance, position-specific carbon isotope variation in an amino acid isolated from a biological matrix. We present a method for the precise characterization of isotope ratios in serine and propose applications probing metabolism in plants. We discuss the potential for extending these approaches to other amino acids, paving the way for novel applications.

59 BASIC BIOLOGICAL SCIENCES↗

Stable isotope analysis at the molecular level: A new approach for determining the origins of amino acids in the Murchison meteorite

A combined gas chromatography/isotope ratio mass spectrometry (GC/IRMS) method has been developed that permits the direct stable carbon isotope analysis of N(O)-trifluoroacetyl-isopropyl esters of individual amino acids and their respective enantiomers at nanomole abundances. Calculation of the original delta C-13 values of the amino acids is accomplished via a correction for the carbon introduced during the derivatization process. Previous GC/IRMS analyses of individual amino acids in the non-hydrolyzed water extract of an interior sample of a Murchison meteorite stone revealed an enrichment in C-13 relative to terrestrial organic matter, in agreement with previous findings for bulk extracts. The range of amino acid delta C-13 values (+5 to +30 per mill, PDB) suggests possible kinetic effects during synthesis. In this study, an apparent kinetic isotope effect was also observed for the amino acid products of a spark discharge experiment. These preliminary resutls are supportive of a similar mechanism for the abiotic synthesis of amino acids in the Murchison meteorite.

Engel, M. H.↗

Single-Particle Isotopic Analysis Using the Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Coupled to an Orbitrap Mass Spectrometer

Isotope ratio (IR) determinations on individual particles can provide valuable information relative to the sample, including processing and dating, which could be valuable to geological and nuclear material analysis communities. In comparison to “bulk” measurements, in which all particle information is lost and homogenized within a sample, “particle” measurements allow for fingerprinting and can provide unique insights related to the sample’s nano- and micro- compositions. Furthermore, the complex nature of particles, with potential isobaric interferences from either the matrix or other elements within the same particle, poses a significant analytical challenge for conventional mass spectrometry platforms employed for elemental analysis due to their limited mass resolution. Presented here is the first demonstration of an ultrahigh resolution method for single particle (SP) isotopic analysis using the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an Orbitrap mass spectrometer and FTMS Booster X2T acquisition/processing system. For proof of concept, well-characterized CeO 2 microparticles with a nominal diameter of 1.0 μm were analyzed at a mass resolution of ∼330,000. Important instrumental parameters were optimized to enable the detection of single particles. The 142 Ce/ 140 Ce ratio of individual particles and the population average were determined and compared to an SP inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS) analysis. The isotopic accuracy and precision were determined by two methods and found to be in good agreement with the SP-ICP-TOF-MS method, with the linear regression slope method providing a more accurate ratio, showing a ∼1.4% relative difference from the ratio determined from a particle digest. The encouraging performance of the method was further supported by a determined detection limit of 2.9 fg ( 142 Ce). The developed method is anticipated to overcome many of the challenges posed by isobaric interferences encountered in conventional mass spectrometry techniques when analyzing real-world samples for particle isotopic composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analyses at High Spatial Resolution of Organic Molecules in Extraterrestrial Samples: Two-Step Laser Mass Spectrometry: Search for Polycyclic Aromatic Hydrocarbons in Antarctic Meteorite and Micrometeorite Samples

Perhaps the best way to summarize the past three-year grant period is to cite the publications and present a brief synopsis of each: 1. "Indigenous Polycyclic Aromatic Hydrocarbon Molecules in Circumstellar Graphite Grains." Bulk C-12/C-13 isotope ratios observed in some graphite grains extracted from primitive meteorites point strongly to a circumstellar origin. By applying our technique of microprobe two-step laser desorption laser ionization mass spectrometry ((mu)L(sup 2)MS) to individual circumstellar graphite grains we have measured the C-12/C-13 isotope ratio of various polycyclic aromatic hydrocarbons (PAHS) found in these grains. 2. "Deuterium Enrichments in Cluster IDPS," Large enrichments in the D/H isotope ratios in IDPs likely arise from the preservation of presolar molecules. 3. "Evidence for thermalization of surface-disorder molecules at heating rates of 10(exp 8) K/s". A careful study of the ((mu)L(sup 2)MS) of aniline-d(sub 7) from a single-crystal surface (0001) of sapphire (al2O3) shows that all measured properties are consistent with a thermal mechanism for desorption. 4. "Search for past life on Mars; possible relic biogenic activity in Martian meteorite ALH 84001. The authors examined the Martian meteorite ALH 84001 and found several lines of evidence compatible with existence of past primitive (single-cell) life on early Mars. 5. "Microprobe two-step laser mass spectrometry as an analytical tool for meteorite samples". THis paper presents a comprehensive review of (mu)L(sup 2)MS and how this technique can be applied to meteoritic samples. 6. "Indigenous polycyclic aromatic hydrocarbons in circumstellar graphite grains from primitive meteorites". The C-12/C-13 isotope ratios were measured for PAHs in a total of 89 spherical graphite grains. 7. "Observation of indigenous polycyclic aromatic hydrocarbons in "Giant" carbonaceous antarctic micrometeorites." The (mu)L(sup 2)MS method was used to establish the nature and distribution of PAHs in fragments of fifteen (approx. 200 microns) carbonaceous antarctic micrometeorites (AMMs). 8. "Evidence for the extraterrestrial origin of polycyclic aromatic hydrocarbons in the Martian meteorite ALH 84001" We have undertaken additional contamination studies of ALH 84001.

Zare, Richard N.↗

The Genesis Solar Wind Collection Mission: Current Status

The NASA Genesis spacecraft was launched August 8, 2001 on a mission to collect samples of solar wind for greater than or equal to 2 years and then return them to Earth in 2004. Detailed analyses of the solar wind ions implanted into high-purity collection substrates will subsequently be carried out in earth-based laboratories using various mass spectrometry techniques. These analyses are expected to determine key isotopic ratios and elemental abundances in the solar wind and, by extension, in the solar photosphere. Further, the photospheric composition is thought to be representative of the solar nebula with a few exceptions so that the Genesis mission will provide a baseline for the average solar nebula composition with which to compare present-day compositions of planets, meteorites, and asteroids. The implications of the solar oxygen isotopic composition have been discussed. A list of other isotopic and elemental measurement objectives, and some of the rationale behind them, is given.

Barraclough, B. L.↗

The Genesis Mission Solar Wind Collection: Solar-Wind Statistics over the Period of Collection

The NASA Genesis spacecraft was launched August 8, 2001 on a mission to collect samples of solar wind for 2 years and return them to earth September 8, 2004. Detailed analyses of the solar wind ions implanted into high-purity collection substrates will be carried out using various mass spectrometry techniques. These analyses are expected to determine key isotopic ratios and elemental abundances in the solar wind, and by extension, in the solar photosphere. Further, the photospheric composition is thought to be representative of the solar nebula with a few exceptions, so that the Genesis mission will provide a baseline for the average solar nebula composition with which to compare present-day compositions of planets, meteorites, and asteroids. The collection of solar wind samples is almost complete. Collection began for most substrates in early December, 2001, and is scheduled to be complete on April 2 of this year. It is critical to understand the solar-wind conditions during the collection phase of the mission. For this reason, plasma ion and electron spectrometers are continuously monitoring the solar wind proton density, velocity, temperature, the alpha/proton ratio, and angular distribution of suprathermal electrons. Here we report on the solar-wind conditions as observed by these in-situ instruments during the first half of the collection phase of the mission, from December, 2001 to present.

Barraclough, B. L.↗

Measurements of effective actinides neutron capture cross sections in a cadmium-filtered epithermal neutron spectrum

In this work, a total of 20 actinide samples were irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL): 233 U (1), 235 U (1), 236 U (1), 238 U (1), 237 Np (2), 239 Pu (1), 240 Pu (1), 242 Pu (2), 244 Pu (2), 241 Am (2), 243 Am (2), 244 Cm (2), and 248 Cm (2). The samples were loaded in a basket containing a 1.1-mm thick cadmium filter. The presence of the filter drastically changes the neutron spectrum in the samples and accentuates the reaction rates in the resonance region. Isotopic ratios were determined using Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS) that allowed inferring effective capture cross sections. Detailed best-estimate MCNP models of the experiment using ENDF/B-VII.0 nuclear data were developed to calculate the effective neutron cross sections and, subsequently, compare them with the cross sections inferred from experimental results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Bayesian Statistical Analysis for Mass Spectrometric Data Processing

• Thermal ionization mass spectrometry (TIMS) is a “gold standard’ technique for actinide isotope amount ratio and assay measurements. • Ubiquitously used in: • Nuclear Nonproliferation • Nuclear Safeguards • Nuclear Forensics • Basic Science • Savannah River National Laboratory (SRNL) installed a new Thermo Scientific TRITON Plus TIMS in early 2024.

McLarty, Ellis C. [Savannah River National Laborat↗

Bayesian Statistical Analysis for Mass Spectrometric Data Processing

Thermal ionization mass spectrometry (TIMS) is a “gold standard’ technique for actinide isotope amount ratio and assay measurements. • Ubiquitously used in: • Nuclear Nonproliferation • Nuclear Safeguards • Nuclear Forensics • Basic Science • Savannah River National Laboratory (SRNL) installed a new Thermo Scientific TRITON Plus TIMS in early 2024.

McLarty, Ellis C. [Savannah River National Laborat↗

Osmium isotopes in Ivory Coast tektites: Confirmation of a meteoritic component and rhenium depletion

The sensitive negative thermal ionization mass spectrometry method was used for the measurement of concentrations and isotopic ratios of osmium and rhenium in four Ivory Coast tektites. These tektites have crustal major and trace element composition, as well as large negative epsilon(sub Nd)(-20) and positive epsilon(sub Sr)(+260 to +300) which are characteristic for old continental crust. Os concentrations ranging from 0.09 to 0.30 ppb were found, clearly much higher than average crustal values, Os-187/Os-186 ratios of about 1.2-1.7, and low Re-187/Os-186 ratios. These results show unambiguously the existence of a meteoritic component (on the order of 0.06%) in the Ivory Coast tektites. Low Re abundances are the result of fractionation of Re during the impact.

Koeberl, Christian↗

Non-traditional stable isotope measurements using laser desorption Orbitrap mass spectrometry: Implications for planetary missions.

Isotopic fractionation recorded in planetary materials provides insights into physical, chemical, and/or potential biological processes occurring on Solar System bodies. As we enter into the next decades of planetary exploration, the crucial information revealed by isotopic compositions of rocky and icy samples mandates that next generation spaceflight instrumentation possess the capability to measure isotope ratios in situ with sufficient precision/accuracy to distinguish between such processes. Here, in addition to identifying and fingerprinting complex organic materials with high accuracy and ultrahigh mass resolutions, laser desorption Orbitrap™ mass spectrometry (LD-O-MS) has the capability to determine the elemental and isotopic composition of solid planetary materials such as rock, regolith, organics, ice, etc. Here, we use a space-qualified LD-O-MS instrument comprising a 266 nm ultraviolet (UV) laser and Orbitrap mass analyzer ruggedized for planetary applications to investigate the stable isotopic composition of Ti and Zn metal plates. Based on the isotopic analyses, we constrain the performance of the CORALS instrument to sub per mille (‰) level accuracy and precision for Ti and at the per mille (‰) level for Zn. An LD-O-MS instrument is a versatile instrument capable of measuring isotopic composition of a variety of planetary samples and would constitute a critical instrument in the exploration of various planetary bodies including but not limited to Moon, Mars, Enceladus and other ocean or icy worlds, Ceres and other asteroids, and comets, thereby answering several high-priority questions pertaining to the formation and evolution of our Solar System.

58 GEOSCIENCES↗

Actinide Elemental Ratios of Spent Nuclear Fuel Samples by Resonance Ionization Mass Spectrometry

While resonance ionization mass spectrometry (RIMS) has demonstrated utility in measuring isotopic compositions of elements in complex matrices without the need for chemical separation to remove isobaric interferences, it has had limited application in measuring elemental compositions. The ability to determine elemental compositions via an in situ method like RIMS would be an exceptional asset in spent nuclear fuel analysis, where they are important in assessing reactor histories and whose chemical separation presents a radiological hazard. However, quantitative elemental analysis by RIMS requires special considerations because each element is ionized by its own set of lasers tuned to element specific resonant ionization wavelengths. We present the first comprehensive study of measuring elemental ratios by RIMS in spent nuclear fuel. All actinides produced by neutron capture are enhanced significantly radially from the center to the edge of a fuel pellet. This edge effect is not readily accessible by conventional bulk measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutral Mass Spectrometry for Venus Atmosphere and Surface

The assignment is to make precise (better than 1 %) measurements of isotope ratios and accurate (5-10%) measurements of abundances of noble gas and to obtain vertical profiles of trace chemically active gases from above the clouds all the way down to the surface. Science measurement objectives are as follows: 1) Determine the composition of Venus atmosphere, including trace gas species and light stable isotopes; 2) Accurately measure noble-gas isotopic abundance in the atmosphere; 3) Provide descent, surface, and ascent meteorological data; 4) Measure zonal cloud-level winds over several Earth days; 5) Obtain near-IR descent images of the surface from 10-km altitude to the surface; 6) Accurately measure elemental abundances & mineralogy of a core from the surface; and 7) Evaluate the texture of surface materials to constrain weathering environment.

Mahaffy, Paul↗

Virtual Slit Cycloidal Mass Spectrometry for Isotopic Measurements of Actinide Particles

The Virtual Slit Cycloidal Mass Spectrometer is a unique instrument for analysis of particles with mass spectrometry. It combines the unique properties of the cycloidal mass analyzer with capacitive transimpedance amplifier array detectors to make a portable instrument potentially capable of high sensitivity measurements on single particles, including high precision isotope ratios.

47 OTHER INSTRUMENTATION↗

Calcium kinetics with microgram stable isotope doses and saliva sampling

Studies of calcium kinetics require administration of tracer doses of calcium and subsequent repeated sampling of biological fluids. This study was designed to develop techniques that would allow estimation of calcium kinetics by using small (micrograms) doses of isotopes instead of the more common large (mg) doses to minimize tracer perturbation of the system and reduce cost, and to explore the use of saliva sampling as an alternative to blood sampling. Subjects received an oral dose (133 micrograms) of 43Ca and an i.v. dose (7.7 micrograms) of 46Ca. Isotopic enrichment in blood, urine, saliva and feces was well above thermal ionization mass spectrometry measurement precision up to 170 h after dosing. Fractional calcium absorptions determined from isotopic ratios in blood, urine and saliva were similar. Compartmental modeling revealed that kinetic parameters determined from serum or saliva data were similar, decreasing the necessity for blood samples. It is concluded from these results that calcium kinetics can be assessed with micrograms doses of stable isotopes, thereby reducing tracer costs and with saliva samples, thereby reducing the amount of blood needed.

Clinical Trial↗