Search NASA⌕ Search

SEARCH · Search NASA

Results for “JEFFERSON LAB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Level-1 Trigger of the GlueX experiment at Jefferson Lab

The GlueX is a new experiment at Jefferson Lab designed to search for mesons with exotic-quantum-numbers using high-intensity beam of polarized photons incident on a liquid hydrogen target. The goal of the Level-1 trigger of the GlueX experiment is to reduce the background rate induced by electromagnetic and hadronic interactions (to 200 kHz total rate) while keeping efficiency for accepting exotic mesons of interest close to unity. The trigger algorithm is based on measurement of the energy depositions in two electromagnetic calorimeters and hit counts in the tagger hodoscopes, the time-of-flight detector, and the Start Counter. The algorithm will be implemented on electronics boards developed at Jefferson Lab, which will perform online data processing at a 250 MHz clock. We will describe the Level-1 trigger algorithm and overview the trigger electronics.

Somov, Alexander↗

Polarisation observables for strangeness photoproduction on a frozen spin target with CLAS at Jefferson Lab

The FROST experiment at Jefferson Lab used the CLAS detector in Hall B with the intention of performing a complete measurement of polarization observables associated with strangeness photoproduction, in combination with data from previous JLab experiments. This was achieved by utilizing the FROST polarized target in conjunction with polarized photon beams, allowing direct measurement of beam-target double polarization observables. By studying strangeness reactions, such as {gamma}p {yields} K{sup +}{Lambda}{sup 0}, it may be possible to find 'missing' baryon resonances, predicted by symmetric quark models but not observed in previous experiments, whose results are consistent with the di-quark model. It is thought these 'missing' resonances remain undiscovered because they have different coupling strengths for different reaction channels, such as the strangeness reactions, whereas the current data is dominated by studies of pN reactions. Observing these resonances therefore has important implications for our knowledge of the excited states of nucleons, and the models predicting the quark interactions within them. The G polarization observable is one of the beam-target double polarization observables, associated with a longitudinally polarized target and a linearly polarized photon beam, and its measurement for the strangeness reaction {gamma}p {yields} K{sup +}{Lambda}{sup 0} is the focus of the work presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

EM Calorimeters for SoLID at Jefferson Lab

Several approved experiments at Jefferson Lab for the 12 GeV era will use the proposed Solenoid Large Intensity Device (SoLID) spectrometer. Two EM calorimeters with a total area of 15 square meters are required for electron identification and electron-pion separation. The challenge is to build calorimeters that can withstand high radiation doses in high magnetic field region and bring photon signals to low field region for readout. Several types of calorimeters were considered and we are favoring Shashlyk type as a result of balancing performance and cost. Our preliminary design and simulation of SoLID EM calorimeters are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Investigation into the Electromagnetic Interactions between a Superconducting Torus and Solenoid for the Jefferson Lab 12 GeV Upgrade

The Jefferson Lab 12 GeV Upgrade in Hall B will need CLAS12 detector that requires two superconducting magnets. One is a magnet system consisting of six superconducting trapezoidal racetrack-type coils assembled in a Toroidal configuration (Torus) and the second is an actively shielded solenoidal magnet (Solenoid). Both the torus and solenoid are located in close proximity to one another and are surrounded by sensitive detectors. This paper investigates the electromagnetic interactions between the two systems during normal operation as well as during various fault scenarios as part of a Risk Assessment and Mitigation (RAM).

Torus, actively shielded, Solenoid, SSC-NbTi,Ruthe↗

New RF Control System for the 12 GeV Energy Upgrade of the CEBAF Accelerator at Jefferson Lab

The CEBAF Accelerator at Jefferson Lab presently consists of 50 MeV injector, two anti-parallel superconducting linacs and two arcs for transporting beam between the linacs. By the mid-1990s, the accelerator was providing electrons up to 5.75 GeV. The 12 GeV Upgrade is a major accelerator project aimed at doubling the energy by adding 10 (five per linac) new high gradient cryomodules, each providing 100 MV of field. The new cryomodule will consist of eight 7-cell superconducting cavities operating at an average accelerating gradient of 19.5 MV/m and with an external Q=3.2 x 10^7. The high gradient, very high quality factor and large Lorentz detuning coefficient (KL up to 4) pose significant challenges beyond what the present analog low level RF (LLRF) control systems can handle reliably; therefore, a new digital LLRF control system has been developed. The main highlights of the new RF Control system include: a RF front-end with low temperature drift and good linearity, a large FPGA

43 PARTICLE ACCELERATORS↗

The proton form factor ratio at low Q2: New results from Jefferson Lab

Recently an experiment at Jefferson Lab has measured the proton form factor ratio {mu}{sub p}G{sub E}{sup p}/G{sub M}{sup p}, down to Q{sup 2} {approx} 0.3 GeV{sup 2} with unprecedented precision. Based on the results from this experiment, a re-analysis was carried out for the world data on proton form factors, and a new result was extracted for the proton charge radius. The new result is consistent with published CODATA results and is at odds with the new muonic hydrogen measurement at PSI. We present the results of the new measurement, as well as discuss an upcoming experiment to measure the form factor ratio down to even lower Q{sup 2}.

08 HYDROGEN↗

Development of a Bunched Beam Electron Cooler based on ERL and Circulator Ring Technology for the Jefferson Lab Electron-Ion Collider

Jefferson Lab is in the process of designing an electron ion collider with unprecedented luminosity at a 45 GeV center-of-mass energy. This luminosity relies on ion cooling in both the booster and the storage ring of the accelerator complex. The cooling in the booster will use a conventional DC cooler similar to the one at COSY. The high-energy storage ring, operating at a momentum of up to 100 GeV/nucleon, requires novel use of bunched-beam cooling. There are two designs for such a cooler. The first uses a conventional Energy Recovery Linac (ERL) with a magnetized beam while the second uses a circulating ring to enhance both peak and average currents experienced by the ion beam. This presentation will describe the design of both the Circulator Cooling Ring (CCR) design and that of the backup option using the stand-alone ERL operated at lower charge but higher repetition rate than the ERL injector required by the CCR-based design.

Benson, Stephen V.↗

Development of a bunched beam electron cooler for the Jefferson Lab electron-ion collider

Jefferson Lab is in the process of designing an electron-ion collider with unprecedented luminosity at a 65 GeV center-of-mass energy. This luminosity relies on ion cooling in both the booster and the storage ring of the accelerator complex. The cooling in the booster will use a conventional DC cooler similar to the one at COSY. The high-energy storage ring, operating at a momentum of up to 100 GeV/nucleon, requires novel use of bunched-beam cooling. We will present a new design for a Circulator Cooler Ring for bunched-beam electron cooling. This requires the generation and transport of very high-charge magnetized bunches, acceleration of the bunches in an energy recovery linac, and transfer of these bunches to a circulating ring that passes the bunches 11 times through the proton or ion beam inside cooling solenoids. This design requires the suppression of the effects of space charge and coherent synchrotron radiation using shielding and RF compensation.

Benson, Stephen V.↗

Jefferson Lab Injector Beamline Upgrade

The Jefferson Lab injector beamline upgrade was completed in 2023, with vacuum improvements throughout the region. I will discuss the effects of the vacuum improvement on photocathode lifetime, the particulate control measures instituted to protect SRF accelerating cavities, and the latest JLab extreme high vacuum gun installation.

Stutzman, Marcy↗

QCD in nuclear processes at Jefferson Lab

The scientific program at Jefferson Lab to probe the properties of QCD in the nuclear environment is outlined. The experimental facilities are described and recent results are presented including measurements of color transparency and medium modifications of vector mesons. The evidence for the onset of color transparency is modest and changes to the mass and width of the r meson in heavy nuclei are consistent with zero. Finally, the future prospects for the upgraded laboratory are discussed.

Gilfoyle, Gerard↗

The Jefferson Lab 12 GeV Program

The Jefferson Lab facilities have undergone a substantial upgrade, both of accelerator, CEBAF, and of the experimental installations. We will discuss the progress to completion of these facilities, the status of accelerator commissioning, and the recent first operations for physics. We will then flesh out the anticipated exciting physics program of the next several years.

Montgomery, Hugh↗

The Barrel Calorimeter for the GlueX Experiment at Jefferson Lab

The GlueX experiment at Jefferson Lab will search for exotic hybrid mesons as evidence of gluonic excitations, in an effort to understand confinement in QCD. The key features of this compelling physics program will be presented together with an overview of the detector, focusing on the electromagnetic barrel calorimeter (BCAL). The BCAL is a 'spaghetti calorimeter,' consisting of layers of corrugated lead sheets, interleaved with planes of 1-mm-diameter, double-clad, scintillating fibres, bonded in the lead grooves using optical epoxy. This detector will consist of 48 modules and will be readout using 3,840 large-area Multi-Photon Pixel counter arrays. The experiment is now in the installation phase with data taking expected in 2015.

Papandreou, Zisis↗

Deep Exclusive PI0 and ETA Electroproduction with CLAS at Jefferson Lab

The CLAS collaboration at Jefferson Lab has undertaken a series of measurements of exclusive $\pi^0$ and $\eta$ electroproduction at a beam energy ~ 6 GeV over a large kinematic coverage in $Q^2, t$ and $x_B$. New results of extracted structure functions $\sigma_L+\sigma_T, \sigma_{LT}$ and $\sigma_{TT}$, are presented in the kinematic range $Q^2$ from 1.2 to 3.2 GeV$^2$/c$^2$, $|t|$ from $|t_{min}|$ to 1.2 GeV$^2$/c$^2$ and $x_B$ from 0.1 to 0.6. Recent theoretical work [1,2] indicate that pseudoscalar meson production is uniquely sensitive to quark helicity-flip processes. The new results, together with CLAS measurements of beam spin asymmetries $A_\phi$ [3] and cross section ratios $\sigma(\pi_0)/\sigma(\eta)$ , compared with theoretical calculations [1,2] that are based on the helicity-flip transversity GPDs, provide supporting evidence that pseudoscalar meson production at these kinematics may be dominated by the handbag mechanism and helicity-flip transversity GPDs.

Stoler, Paul↗

Development of a green laser cavity for precision Compton polarimetery in Jefferson Lab Hall A

Many experiments at Jefferson Lab require good knowledge of the polarization of the electron beam. The Pb Radius Experiment (PREx) demands polarization measurement of a lower energy (1.0 GeV) electron beam at 1.0 % accuracy, which can not be achieved by the infra-red (1064 nm) laser Compton polarimeter presently operating in Hall A. Therefore a green laser (CW, 532 nm) based Fabry-Pe´rot cavity for upgraded high precision Compton Polarimetry has been proposed and under development. The system used as a high energy polarized photon target for measuring the polarization of a low- to high-energy (1.0 GeV ? 11.0 GeV) electron beam in a nondestructive manner. Our goal is to amplify a low power laser beam to achieve 1.5 kW of intra cavity power to improve signal to noise ratio of the polarimeter. We locked our test cavity to a frequency doubled Nd:YAG tunable narrow linewidth laser using the Pound-Drever-Hall (PDH) technique. The recent progress and future plan of this project will be presented.

Nanda, Sirish↗

Recent results in DIS from Jefferson Lab

Recent results in Deep Inelastic processes measured at Jefferson Lab are presented. In addition to the inclusive reactions typically discussed in the context of Deep Inelastic (electron) Scattering, particular emphasis is given to Deep Exclusive and semi inclusive reactions. Jefferson Lab has made significant contributions to the understanding of the partonic structure of the nucleon at large x, and with its first dedicated measurements is already providing important contributions to understanding the three-dimensional structure of the nucleon via constraints on Generalized Parton Distributions (GPDs) and Transverse Momentum Distributions (TMDs).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Commissioning the Super High Momentum Spectrometer in Hall C at Jefferson Lab

The Super High Momentum Spectrometer (SHMS) is a new spectrometer installed in Hall C at Jefferson Lab that can detect particles over a range of central momenta from 2-11 GeV/c and scattering angles from 5.5 to 40 degrees. Jefferson Lab delivers a high intensity electron beam with an energy up to 11 GeV to fixed targets in Hall C. The SHMS is a highly precise and essential upgrade for the 12 GeV Jefferson Lab physics program. Its beam line consists of a dipole magnet with a 3-degree horizontal bend, three quadrupole magnets for horizontal and vertical focusing of the beam, and the spectrometer dipole capable of a 4 T central magnetic field and 18.4-degree bend angle. Measurements in Hall C can be taken with the SHMS independently or in coincidence with the existing High Momentum Spectrometer (HMS). The SHMS was installed in the spring of 2017 and commissioned during the fall 2017/winter 2018 using a range of electron beam energies. This talk summarizes the initial results of the optics tuning of the SHMS and the performance during recent experimental running to include initial elastic hydrogen scattering measurements.

Szumila-Vance, Holly↗

The Future Polarized Target Program at Jefferson Lab

Polarized targets have played a crucial role in Jefferson Lab's exploration of nuclear structure over the past four decades. The three original experimental halls have seen 19 separate installations of polarized solid or gas targets for use in the particle physics scattering experiments, and this trend will continue in the next decade. Five polarized target systems are in preparation for use at JLab in the coming years. Hall B will see the use of two solid polarized targets, one longitudinally polarized to the beam, the other transversely, as well as a novel 3He gas polarized target. In Hall C, new experiments will augment the tensor polarization in dynamically polarized solids. Plans are under development to bring a polarized solid target to Jefferson Lab's photon beam hall, Hall D, for the first time. To support these efforts, the JLab polarized target group is building a test laboratory to develop dynamic nuclear polarization techniques, as well as an apparatus to irradiate target material using electrons from JLab's injector test facility. In this talk, we will explore the development progress and plans for each of these efforts.

Maxwell, James [Thomas Jefferson National Accelera↗

Exploring the Nature of Matter: Jefferson Lab and Its Plans

The Thomas Jefferson National Accelerator Facility in Newport News, Va., is one of the premier facilities for nuclear physics in the world. Utilizing high-luminosity and high-polarization continuous-wave electron beams, the 6 giga-electronVolt physics lab has unveiled many secrets of the atomic and subatomic world during the past decade. As the speaker for Catholic University?s 29th annual Karl Herzfeld Memorial Lecture, Hugh Montgomery, director of the Jefferson Lab, will describe the facility and its plans. Operated under the auspices of the U.S. Department of Energy, the Jefferson Lab is currently executing an upgrade of the power of the accelerator from 6 giga-electronVolts to 12 giga-electronVolts; this project was recommended as the top priority in the most recent U.S. nuclear physics long-range plan. The upgrade will enable breakthroughs to be made in the areas of quark confinement in matter and parity violation in particle interactions, as well as allowing increased understanding of the three-dimensional structure of the neutron and proton. Beyond this upgrade, Jefferson Lab will be proposing to build an electron-ion collider, which would for the first time enable researchers to study the fundamental structure of matter by directly probing the subatomic particles called gluons. A reception immediately follows the lecture. CUA?s Herzfeld Memorial Lecture is named in honor of Karl F. Herzfeld, who chaired the university?s physics department from 1936 to 1961; he passed away in 1978. Herzfeld built CUA?s initially tiny physics department ?into a strong research department that achieved national renown,? according to the National Academy of Sciences journal Biographical Memoirs. The American Institute of Physics has reported that CUA?s physics department brings in more research money per professor than almost any other physics department in the country. CUA?s physics department has been involved in the physics program of the Jefferson Lab since its inception, including participation in the design and construction of experimental equipment. Current CUA participants in Jefferson Lab research include Professor Emeritus Hall Crannell, Professor Daniel Sober, Associate Professor Franz Klein and Assistant Professor Tanja Horn. The lecture is free and open to the public.

Montgomery, Hugh↗