Search NASA⌕ Search

SEARCH · Search NASA

Results for “LABORATORY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Performance of pumped counterflow virtual impactors to study aerosol interactions with laboratory generated warm clouds

Pumped Counterflow Virtual Impactors (PCVI) are designed to separate aerosols based on aerodynamic diameter, which is particularly useful for isolating cloud droplets and ice crystals from smaller particles. However, the PCVI transmission efficiency (TE) values reported in the literature show considerable variability, and little information is available on the TEs for cloud liquid droplets. Here, we determined the optimal flow conditions for PCVI sampling for different activation ratios from the MTU Pi-cloud chamber, highlighting the conditions that maximize droplet residual sampling while minimizing interstitial transmission. Even for a lower limit cloud activation ratio = 1:10, an add flow of 1.5 LPM achieves a residual fraction greater than 0.80, with a droplet TE of ∼15% for typical Pi-Chamber droplets with diameters between 3.5 to 10 µm. This framework can be adapted for field cloud measurements based on the cloud conditions of interest. TE for cloud droplets under flow conditions at which ∼99% of the unactivated submicron particles were removed was substantially lower between 8 and 16% than for supermicron dry particles (∼30 to 40% for 3 µm polystyrene latex spheres). In addition, we conducted a comparison of the performances of three similar PCVI units to assess repeatability for dry aerosols and cloud droplets. All three PCVIs performed similarly in rejecting submicron particles smaller than the desired cutoff diameter. One of the units showed lower TEs due to a misalignment of the internal orifice. We discuss a procedure that improved alignment and performance.

54 ENVIRONMENTAL SCIENCES↗

Laboratory evaluation of distributed coaxial cable temperature sensors for application in CO 2 sequestration well characterization: Original Research Article: Laboratory evaluation of distributed coaxial cable temperature

Downhole monitoring plays a crucial part in a geological carbon dioxide (CO 2 ) sequestration project, especially in providing early warnings of failure. However, most downhole monitoring technologies are often low in spatial resolution and time-consuming, or expensive and have system longevity issues. To address this issue, a robust and cost-effective distributed coaxial cable Fabry-Perot interferometer-based temperature sensor is proposed for real-time downhole monitoring. The coaxial cable sensor (CCS) was made in house and tested using a high pressure high temperature (HPHT) testing apparatus to study the sensor accuracy, sensitivity, stability, and crosstalk effect in simulated downhole conditions. The laboratory test results indicate that the sensor can work under simulated downhole conditions of pressures up to 1000 psia and temperatures up to 110°C. At 1 ATM, the sensor has an accuracy of about 1%. At 1000 psia, the hysteresis phenomenon is observed, but it is reduced and tends to stabilize after repeated heating and cooling treatments. The pressure crosstalk effect was observed on the flexible cable sensor and minimized on the rigid cable sensor. The temperature and pressure range of the distributed CCS allows long-term in situ monitoring for a well depth up to 2500 feet, which would prove of great value in detecting temperature change associated with wellbore leakage that may lead to groundwater contamination.

54 ENVIRONMENTAL SCIENCES↗

Direct numerical simulations of a high Karlovitz number laboratory premixed jet flame – an analysis of flame stretch and flame thickening [Direct numerical simulations of a high Ka laboratory premixed jet flame - an analysis of flame stretch and flame thickening]

This article reports an analysis of the first detailed chemistry direct numerical simulation (DNS) of a high Karlovitz number laboratory premixed flame. The DNS results are first compared with those from laser-based diagnostics with good agreement. The subsequent analysis focuses on a detailed investigation of the flame area, its local thickness and their rates of change in isosurface following reference frames, quantities that are intimately connected. The net flame stretch is demonstrated to be a small residual of large competing terms: the positive tangential strain term and the negative curvature stretch term. The latter is found to be driven by flame speed–curvature correlations and dominated in net by low probability highly curved regions. Flame thickening is demonstrated to be substantial on average, while local regions of flame thinning are also observed. The rate of change of the flame thickness (as measured by the scalar gradient magnitude) is demonstrated, analogously to flame stretch, to be a competition between straining tending to increase gradients and flame speed variations in the normal direction tending to decrease them. The flame stretch and flame thickness analyses are connected by the observation that high positive tangential strain rate regions generally correspond with low curvature regions; these regions tend to be positively stretched in net and are relatively thinner compared with other regions. Finally, high curvature magnitude regions (both positive and negative) generally correspond with lower tangential strain; these regions are in net negatively stretched and thickened substantially.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a compact in situ polarized {sup 3}He neutron spin filter at Oak Ridge National Laboratory

We constructed a compact in situ polarized {sup 3}He neutron spin filter based on spin-exchange optical pumping which is capable of continuous pumping of the {sup 3}He gas while the system is in place in the neutron beam on an instrument. The compact size and light weight of the system simplifies its utilization on various neutron instruments. The system has been successfully tested as a neutron polarizer on the triple-axis spectrometer (HB3) and the hybrid spectrometer (HYSPEC) at Oak Ridge National Laboratory. Over 70% {sup 3}He polarization was achieved and maintained during the test experiments. Over 90% neutron polarization and an average of 25% transmission for neutrons of 14.7 meV and 15 meV was also obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System overview and characterization of a high-temperature, high-pressure, entrained-flow, laboratory-scale gasifier

The high-temperature, high-pressure, entrained-flow, laboratory-scale gasifier at the Colorado School of Mines, including the primary systems and the supporting subsystems, is presented. The gasifier is capable of operating at temperatures and pressures up to 1650 °C and 40 bar. The heated section of the reactor column has an inner diameter of 50 mm and is 1 m long. Solid organic feedstock (e.g., coal, biomass, and solid waste) is ground into batches with particle sizes ranging from 25 to 90 μm and is delivered to the reactor at feed rates of 2–20 g/min. The maximum useful power output of the syngas is 10 kW, with a nominal power output of 1.2 kW. The initial characterization and demonstration results of the gasifier system with a coal feedstock are also reported.

09 BIOMASS FUELS↗

Effect of the solenoid in various conditions of the laser ion source at Brookhaven National Laboratory

In the laser ion source (LIS) at the Brookhaven National Laboratory (BNL), a solenoid is used to guide the laser ablation plasma and modulate the extracted beam current. Many types of ion species are guided. In some cases, the plasma plume is injected into the solenoid away from the solenoidal axis. To investigate the effects of the solenoid on the beam extracted from the plasma that has different properties, the beam current was measured in the setup of the LIS at the BNL. The beam current of Li, Al, Si, Fe, and Au increased when the magnetic field was applied. For most of the species the peak current and the total charge within a single beam pulse increased around 10 times with a magnetic field less than 100 G. In addition, for some species the rate of increase of the peak currents became smaller when the magnetic flux densities were larger than certain values depending on the species. In this case, the current waveforms were distorted. At the same magnetic field value, the field was more effective on lighter species than on heavier ones. When plasma was injected offset from the axis of the solenoid, peak current and total charge became half of those without offset. The experimental data are useful for the operation of the LIS at the BNL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 Torus Detector Magnet at Jefferson Laboratory

The CLAS12 Torus is a toroidal superconducting magnet, which is part of the detector for the 12-GeV accelerator upgrade at Jefferson Laboratory (JLab). The coils were wound/fabricated by Fermilab, with JLab responsible for all other parts of the project scope, including design, integration, cryostating the individual coils, installation, cryogenics, I&C, etc. This paper provides an overview of the CLAS12 Torus magnet features and serves as a status report of its installation in the experimental hall. Completion and commissioning of the magnet is expected in 2016.

43 PARTICLE ACCELERATORS↗

Use of Electronic Laboratory Notebooks (ELN) in a Laboratory Information Management System (LIMS) [Slides]

The Actinide Analytical Chemistry (CAAC) group at Los Alamos National Laboratory (LANL) uses the LabWare LIMS (LabWare 7) system to manage our samples and material at risk. The LIMS system also provides other functionality which the Plasma Spectroscopy (PS) team has developed along with our LIMS team to provide streamlining and automation of all sample related actions required by PS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Teaching sterile neutrinos in an undergrad laboratory: a sterile-neutrino search using data from the MicroBooNE liquid-argon time projection chamber performed in an undergraduate teaching laboratory

Dataset associated with "A sterile-neutrino search using data from the MicroBooNE liquid-argon time projection chamber performed in an undergraduate teaching laboratory" an educational paper to teach data analisys within particle physics for 3-4 yr physics major undergrads. Data format are csv, h5 and pkl

Gramellini, Elena [Manchester U.] (ORCID:000000031↗