Langmuir probe evidence for a nocturnal ionization source at Fort Churchill.
Nocturnal electron concentrations and temperature at Manitoba measured by rocket-borne Langmuir probe, compared with F 1 region
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Nocturnal electron concentrations and temperature at Manitoba measured by rocket-borne Langmuir probe, compared with F 1 region
The temporal evolution of the voltage-current characteristic of a spherical Langmuir probe in the near-wake region of a conducting body is investigated in a pulsed plasma device. Measurements of the current collected by a sphere placed on axis behind a conducting disk are presented as a function of the bias voltage and time. The bias voltage on the collecting sphere is large enough, ranging from +500 to -3000 V, to attract ions or electrons across the wake region. In addition, plasma potential profiles as a function of sphere bias voltage and time throughout the nearwake and midwake region are presented. It is found that for a negative sphere bias a threshold voltage exists for current collection. This threshold voltage decreases during the formation of the wake behind the conducting disk. Potential measurements indicate that the sheath region around the negatively biased sphere contracts as the wake region establishes itself. This contraction of the sheath region increases the electric field attracting ions to the sphere and decreases the threshold voltage for current collection. For positive sphere bias voltage the current collected by the sphere does not exhibit a threshold voltage but is monotonically increasing.
Fluorocarbon gases, such as CF4, and their mixtures are widely used in contemporary low-pressure and high-density plasma processing techniques. In such plasmas Langmuir probe is one of the most commonly employed diagnostic techniques to obtain electron number density (ne), electron temperature (Te), electron energy distribution function (EEDF), mean electron energy (Ee), ion number density (ni), and plasma potential (Vp). In this paper we report probe data for planar inductively coupled plasmas in CF4/O2/Ar mixtures. By varying the relative concentrations in the mixture, radial profiles of ne, ni, Te, Ee, Vp, EEDF were measured in the mid-plane of the plasma at 10 mTorr and 20 mTorr of gas pressures, and 200 W and 300 W of RF powers. Data show that ne and ni decrease with increase of CF4 content and decrease of gas-pressure but they increase with increase of RF-power, whereas Vp increases with decrease of gas-pressure and remains independent of RF-power. However, they all peak at the center of the plasma and decrease towards the edge while Te follows the other way and increases a little with increase of power. The measured EEDFs exhibit Druyvesteyn-like distribution at all pressures and powers. Data are analyzed and will be presented.
Langmuir and interferometric measurements on electron concentration in arc heated wind tunnel using air and nitrogen
Plasma parameters, such as, electron number density (ne), electron temperature (Te), y electron energy distribution function (EEDF), mean electron energy (Ee), ion number density (ni), and plasma potential (Vp), have been measured by using Langmuir probe in low-pressure (10-50 mTorr) inductively coupled CHF3/Ar and CHF3/Ar/O2 plasmas generated in the GEC cell. The measurements were made at the center of the plasma, keeping the lower electrode grounded, for various CHF3/Ar and Ar/CHF3/O2 mixtures operating at 10-50 mTorr pressures and two input RF power levels, 200 and 300 W. EEDF data show a strong Druyvesteyn distribution with relatively lower number of low energy electrons as compared to a Maxwell distribution and a large electron population with energies higher than the plasma potential. The results further show that at low CHF3 concentrations (less than 50%) the electron number density remains nearly constant with increase in pressure. At higher CHF3 concentrations, however, it decreases with increase in pressure. Plasma potential and electron temperature increase with decrease in pressure and with increase in CHF3 concentration. An analysis of the above observations and mechanisms will be presented.
The Plasmoid Thruster Experiment (PTX) operates by inductively producing plasmoids in a conical theta-pinch coil and subsequently ejecting them at high velocity. An overview of PTX is described in a companion paper. The shape and magnetic field structure of the translating plasmoids will be measured with of an array of inductive magnetic field probes. Six sets of two B-dot probes (for a total of twelve probes) have been constructed for measuring B(sub z) and B(sub theta), the axial and azimuthal components of the magnetic field. The probes were calibrated with a Helmholtz coil, driven alternately by a high-voltage pulser or a signal generator. The probes are wound on a G-10 form, and have an average (calibrated) NA of 9.37 x 10(exp -5) square meters, where N is the number of turns and A is cross-sectional area. The frequency response of the probes was measured over the range from 1 kHz to 10 MHZ. The electron number density n(sub e), electron temperature T(sub e) and velocity v will be determined from measurements taken with a quadruple Langmuir probe, situated in the exhaust chamber. Three of the four probes on the quadruple probe sample the current-voltage characteristic, and from this yield measurements of T(sub e) and n(sub e). The fourth probe provides a measurement of plasma flow velocity. A 6-inch long alumina rod, hollowed with four holes to house the probe wires, is being used to construct the quadruple probe. A variety of propellants will be used, including hydrogen, nitrogen and argon. From the measurements of the plasmoid mass, density, temperature, and velocity, the basic propulsion characteristics of PTX will be evaluated.
Statistical properties of the scrape-off layer plasma fluctuations are studied in ohmically heated plasmas in the Alcator C-Mod tokamak. For the first time, plasma fluctuations as well as parameters that describe the fluctuations are compared across measurements from a mirror Langmuir probe (MLP) and from gas-puff imaging (GPI) that sample the same plasma discharge. This comparison is complemented by an analysis of line emission time-series data, synthesized from the MLP electron density and temperature measurements. The fluctuations observed by the MLP and GPI typically display relative fluctuation amplitudes of order unity together with positively skewed and flattened probability density functions. Such data time series are well described by an established stochastic framework that models the data as a superposition of uncorrelated, two-sided exponential pulses. The most important parameter of the process is the intermittency parameter, $γ=τ_d/τ_w$, where τd denotes the duration time of a single pulse and $τ_w$ gives the average waiting time between consecutive pulses. In this study we show, using a new deconvolution method, that these parameters can be consistently estimated from different statistics of the data. We also show that the statistical properties of the data sampled by the MLP and GPI diagnostic are very similar. Finally, a synthetic GPI signal using only plasma parameters sampled by the MLP shows qualitatively different fluctuation statistics from the measured GPI signal.
Astrophysical flows may be studied by reproducing similar conditions using a coaxial plasma accelerator operating in the deflagration regime (or plasma deflagration accelerator). This allows for the recreation and investigation of dynamics present in complex highly coupled plasma systems at the laboratory scale. Here we report on measurements of the plasma density, temperature, plasma potential and velocity found using a quadruple Langmuir probe (QLP) on such a deflagration accelerator in the form of the Stanford Coaxial High ENerGy (CHENG) device operating with multiple gases – specifically argon, nitrogen and hydrogen. Experiments show a general decrease in bulk plasma velocity with gas atomic mass from upwards of 120 km s –1 with hydrogen to less than 30 km s –1 with argon. There was an accompanying increase in peak plasma density with increasing atomic mass from ~3 × 10 20 m –3 with hydrogen to ~1.5 × 10 21 m –3 with argon. It was found that the momentum flux and internal energy density also generally increase with atomic mass while the particle flux is constant between shots. Further investigation is needed to understand these correlations and the underlying physics. Lastly, comparisons with scaling laws show that while the CHENG device may be operated in such a way as to simulate the effects of bulk solar wind movement, it may not properly capture the thermal effects.
Technological advancement in the microelectronics industry requires an understanding of the physical and chemical processes occurring in plasmas of fluorocarbon gases, such as carbon tetrafluoride (CF4) which is commonly used as an etchant, and their mixtures to optimize various operating parameters. In this paper we report data on electron number density (ne), electron temperature'(Te), electron energy distribution function (EEDF), mean electron energy, ion number density (ni), and plasma potential (Vp) measured by using Langmuir probe in an inductively coupled 13.56 MHz radio frequency plasmas generated in 50%Ar:50%CF4 mixture in the GEC cell. The probe data were recorded at various radial positions providing radial profiles of these plasma parameters at 10-50 mTorr pressures and 200 W and 300 W of RF power. Present measurements indicate that the electron and ion number densities increase with increase in pressure and power. Whereas the plasma potential and electron temperature decrease with increase in pressure, and they weakly depend on RF power. The radial profiles exhibit that the electron and ion number densities and the plasma potential peak at the center of the plasma with an exponential fall away from it, while the electron temperature has a minimum at the center and it increases steadily towards the electrode edge. The EEDFs have a characteristic drop near the low energy end at all pressures and pressures and their shapes represent non-Maxwellian plasma and exhibit more like Druyvesteyn energy distribution.v
Abstract Electron and ion energy distribution functions and other plasma parameters such as plasma potential (V(sub p)) , electron temperature (T(sub e)), and electron and ion number densities (n (sub e) and n(sub i)) in low pressure CF4 plasmas have been measured. The experiments were conducted in a GEC cell using an inductively coupled plasma (ICP) device powered by a 13.56 MHz radio-frequency (rf) power source. The measurements were made at 300 W of input rf power at 10, 30 and 50 mTorr gas pressures. Langmuir probe measurements suggest that n(sub e), n(sub i) and V(sub p) remain constant over 60% of the central electrode area, beyond which they decrease. Within the limits of experimental error (+/- 0.25 eV), T(sub e) remains nearly constant over the electrode area. T(sub e) and V(sub p) increase with a decrease in pressure. n(sub e) and n(sub i) are not affected as significantly as T(sub e) or V(sub p) by variation in the gas pressure. The electron energy distribution function (EEDF) measurements indicate a highly non-Maxwellian plasma. CF3+ is the most dominant ion product of the plasma, followed by CF2+ and CF+. The concentrations of CF2+ and CF+ are much larger than that is possible from direct electron impact ionization of the parent gas. The cross-section data suggest that the direct electron impact ionization of fragment neutrals and negative ion production by electron attachment may be responsible for increase of the minor ions.
Electrical charging of the International Space Station (ISS) is a matter of serious concern resulting from the possibility of vehicle arcing and electrical shock hazard to crew during extravehicular activity (EVA). A Plasma Contactor Unit (PCU) was developed and integrated into ISS in order to control the ISS floating potential, thereby, minimize vehicle charging and associated hazards. One of the principle factors affecting ISS electrical charging is the ionosphere plasma state (i.e., electron temperature and density). To support ISS electrical charging studies a Floating Potential Monitoring Unit (FPMU) is also integrated into ISS in order to measure the ionosphere properties using Langmuir probes (LP). The FPMU was located on the Starboard side of ISS. The PCU is located near the center of ISS with its plasma exhaust pointed to port. From its integration on ISS in 2006 through November of 2009, the FPMU data exhibited nominal characteristics during PCU operation. On November 21, 2009 the FPMU was relocated from the Starboard location to a new Port location. After relocation significant enhanced noise was observed in both the LP current-voltage sweeps and the derived electron temperature data. The enhanced noise only occurred when the PCU was in discharge and at unique and repeatable locations of the ISS orbit. The cause of this enhanced noise was investigated. It was found that there is coupling occurring between the PCU plasma and the FPMU LP. In this paper we shall 1) present the on-orbit data and the presence of enhanced noise, 2) demonstrate that the coupling of the PCU plasma and the FPMU measurements is geomagnetically organized, 3) show that coupling of the PCU plasma and the FPMU is primarily due to and driven by particle-wave interaction and 4) show that the ionosphere conditions are adequate for Alfven waves to be generated by the PCU plasma.
Absolute fluxes and energy distributions of ions in inductively coupled plasmas of Ar, CHF3/Ar, and CHF3/Ar/O2 have been measured. These plasmas were generated in a Gaseous Electronics Conference (GEC) cell modified for inductive coupling at pressures 10-50 mTorr and 100-300 W of 13.56 MHz radio frequency (RF) power in various feedgas mixtures. In pure Ar plasmas, the Ar(+) flux increases linearly with pressure as well as RF-power. Total ion flux in CHF3 mixtures decreases with increase in pressure and also CHF3 concentration. Relative ion fluxes observed in the present studies are analyzed with the help of available cross sections for electron impact ionization and charge-exchange ion-molecule reactions. Measurements of plasma potential, electron and ion number densities, electron energy distribution function, and mean electron energy have also been made in the center of the plasma with a RF compensated Langmuir probe. Plasma potential values are compared with the mean ion energies determined from the measured ion energy distributions and are consistent. Electron temperature, plasma potential, and mean ion energy vary inversely with pressure, but increase with CHF3 content in the mixture.
First-principles particle-in-cell (PIC) simulation is a powerful tool for understanding plasma behavior, but this power often comes at great computational expense. Artificially reducing the ion/electron mass ratio is a time-honored practice to reduce simulation costs. Usually, this is a severe approximation. However, for steady-state collisionless, electrostatic (Vlasov–Poisson) systems, the solution with reduced mass ratio can be scaled to the solution for the real mass ratio, with no approximation. This “scaled mass” method, which works with already-existing PIC codes, can reduce the computation time for a large class of electrostatic PIC simulations by the square root of the mass ratio. The particle distributions of the resulting steady state must be trivially rescaled to yield the true distributions, but the self-consistent electrostatic field is independent of the mass ratio. This method is equivalent to “numerical timestepping,” an approach that evolves electron and ion populations with different time steps. Numerical timestepping can be viewed as a special case of the speed-limited PIC (SLPIC) method, which is not restricted to steady-state phenomena. Although the scaled-mass approach is simplest, numerical timestepping and SLPIC more easily generalize to include other effects, such as collisions. The equivalence of these new approaches is demonstrated by applying them to simulate a cylindrical Langmuir probe in electron–argon plasma, speeding up simulation by two orders of magnitude. Methods such as SLPIC can therefore play an invaluable role in interpreting probe measurements by including geometric effects, collisions, secondary emission, and non-Maxwellian distributions.
Computerized data reduction techniques for obtaining local electron temperature variations in plasma beams produced by magnetoplasmadynamic accelerators
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Not provided.
Explore the source record for details and available documents.