Search NASA⌕ Search

SEARCH · Search NASA

Results for “LASER SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Space Launch System Base Heating Test: Tunable Diode Laser Absorption Spectroscopy

This paper describes the Tunable Diode Laser Absorption Spectroscopy (TDLAS) measurement of several water transitions that were interrogated during a hot-fire testing of the Space Launch Systems (SLS) sub-scale vehicle installed in LENS II. The temperature of the recirculating gas flow over the base plate was found to increase with altitude and is consistent with CFD results. It was also observed that the gas above the base plate has significant velocity along the optical path of the sensor at the higher altitudes. The line-by-line analysis of the H2O absorption features must include the effects of the Doppler shift phenomena particularly at high altitude. The TDLAS experimental measurements and the analysis procedure which incorporates the velocity dependent flow will be described.

Parker, Ron↗

Asynchronous x-ray multiprobe data acquisition for x-ray transient absorption spectroscopy

Laser pump X-ray Transient Absorption (XTA) spectroscopy offers unique insights into photochemical and photophysical phenomena. X-ray Multiprobe data acquisition (XMP DAQ) is a technique that acquires XTA spectra at thousands of pump-probe time delays in a single measurement, producing highly self-consistent XTA spectral dynamics. In this work, we report two new XTA data acquisition techniques that leverage the high performance of XMP DAQ in combination with High Repetition Rate (HRR) laser excitation: HRR-XMP and Asynchronous X-ray Multiprobe (AXMP). HRR-XMP uses a laser repetition rate up to 200 times higher than previous implementations of XMP DAQ and proportionally increases the data collection efficiency at each time delay. This allows HRR-XMP to acquire more high-quality XTA data in less time. AXMP uses a frequency mismatch between the laser and x-ray pulses to acquire XTA data at a flexibly defined set of pump-probe time delays with a spacing down to a few picoseconds. AXMP introduces a novel pump-probe synchronization concept that acquires data in clusters of time delays. Further, the temporally inhomogeneous distribution of acquired data improves the attainable signal statistics at early times, making the AXMP synchronization concept useful for measuring sub-nanosecond dynamics with photon-starved techniques like XTA. In this paper, we demonstrate HRR-XMP and AXMP by measuring the laser-induced spectral dynamics of dilute aqueous solutions of Fe(CN) 6 4₋ and [Fe II (bpy) 3 ] 2+ (bpy: 2,2'-bipyridine), respectively.

47 OTHER INSTRUMENTATION↗

Lifetime-Limited Interrogation of Two Independent 27 Al + Clocks Using Correlation Spectroscopy

Laser decoherence limits the stability of optical clocks by broadening the observable resonance linewidths and adding noise during the dead time between clock probes. Correlation spectroscopy avoids these limitations by measuring correlated atomic transitions between two ensembles, which provides a frequency difference measurement independent of laser noise. Here, we apply this technique to perform stability measurements between two independent clocks based on the 1 S 0 ↔ 3 P 0 transition in 27 Al + . By stabilizing the dominant sources of differential phase noise between the two clocks, we observe coherence between them during synchronous Ramsey interrogations as long as 8 s at a frequency of 1.12 × 10 15 Hz. Here, the observed contrast in the correlation spectroscopy signal is consistent with the 20.6 s 3 P 0 state lifetime and represents a measurement instability of (1.8 ± 0.5) × 10 –16 /√τ/s for averaging periods longer than the probe duration when dead time is negligible.

74 ATOMIC AND MOLECULAR PHYSICS↗

Single-tone and two-tone AM-FM spectral calculations for tunable diode laser absorption spectroscopy

A generalized theory for optical heterodyne spectroscopy with phase modulated laser radiation is used which allows the calculation of signal line shapes for frequency modulation spectroscopy of Lorentzian gas absorption lines. In particular, synthetic spectral line shapes for both single-tone and two-tone modulation of lead-salt diode lasers are presented in which the contributions from both amplitude and frequency modulations are included.

Chou, Nee-Yin↗

Monitoring of catalyst performance in CO2 lasers using frequency modulation spectroscopy with diode lasers

Closed-cycle CO2 laser operation with removal of O2 and regeneration of CO2 can be achieved by catalytic CO-O2 recombination. Both parametric studies of the optimum catalyst formulation and long-term performance tests require on line monitoring of CO, O2 and CO2 concentrations. There are several existing methods for molecular oxygen detection. These methods are either intrusive (such as electrochemical method or mass spectrometry) or very expensive (such as CARS, UV laser absorption). Researchers demonstrated a high-sensitivity spectroscopic measurement of O2 using the two-tone frequency modulation spectroscopy (FMS) technique with a near infrared GaAlAs diode laser. Besides its inexpensive cost, fast response time, nonintrusive measurements and high sensitivity, this technique may also be used to differentiate between isotopes due to its high spectroscopic resolution. This frequency modulation spectroscopy technique could also be applied for the on-line monitoring of CO and CO2 using InGaAsP diode lasers operation in the 1.55 microns region and H2O in the 1.3 microns region. The existence of single mode optical fibers at the near infrared region makes it possible to combine FMS with optical fiber technology. Optical fiber FMS is particularly suitable for making point-measurements at one or more locations in the CO2 laser/catalyst system.

Wang, Liang-Guo↗

Remote methane sensor for emissions from pipelines and compressor stations using chirped-laser dispersion spectroscopy

Leak rates of methane (CH 4 ) from the natural gas supply chain result in lost profit from unsold product, public safety and property concerns due to potential explosion hazards, and a potentially large source of economic damages from legal liabilities. Yet large measurement challenges exist in identifying and quantifying CH 4 leak rates along the vast number and type of components in the natural gas supply chain. This is particularly true of the “midstream” components involved in the gathering, processing, compression, transmission, and storage of natural gas. This project developed and deployed new advances in chirped laser dispersion spectroscopy (CLaDS) to detect methane leaks from pipelines, compressor stations, and other midstream infrastructure from a remote position (standoff detection). The system was deployed from a van to measure fugitive methane leaks from a local compressor station as a proof-of-concept. The technique was validated through mobile laboratory measurements with in-situ sensors as well as controlled releases of methane. The system also mapped a plume from a controlled release of methane by tracking a small unmanned aerial system (sUAS) that carried a corner cube retroreflector which reflected the beam back to the instrument. The drone-based system quantified a leak rate to within 30% of the actual rate and localized the emission location within 5 m of the actual release location at standoff distances of 25-45 m. This sUAS-reflector tracking approach has benefits for mapping leak locations remotely using small drones flying around a facility. Benefits of a commercial sensor with these capabilities include reductions of leaks for pipeline operators (more profit), earlier detection of leaks to avoid catastrophic explosion hazards for public health and to mitigate property damage, and reduced methane emissions to the atmosphere (improving air quality).

03 NATURAL GAS↗

Femtosecond ultraviolet laser absorption spectroscopy for simultaneous measurements of temperature and OH concentration

This Letter reports a femtosecond ultraviolet laser absorption spectroscopy (fs-UV-LAS) for simultaneous in situ measurements of temperature and species. Here, this fs-UV-LAS technique was demonstrated based on X 2 Π-A 2 Σ + transitions of OH radicals near 308 nm generated in low temperature plasmas and flames. The fs-UV-LAS technique has revealed three major diagnostic benefits. First, a series of absorption features within a spectral bandwidth of ~3.2 nm near 308 nm were simultaneously measured and then enabled simultaneous multi-parameter measurements with enhanced accuracy. The results show that the temperature and OH concentration could be measured with accuracy enhanced by 29–88% and 58–91%, respectively, compared to those obtained with past two-narrow-line absorption methods. Second, an ultrafast time resolution of ~120 picoseconds was accomplished for the measurements. Third, due to the large OH X 2 Π-A 2 Σ + transitions in the UV range, a simple single-pass absorption with a 3-cm path length was allowed for measurements in plasmas with low OH number density down to ~2 × 10 13 cm –3 . Also due to the large OH UV transitions, single-shot fs absorption measurements were accomplished in flames, which was expected to offer more insights into chemically reactive flow dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advancing Elemental and Isotopic Analysis of Uranium Mineral Inclusions: Rapid Screening via Laser-Induced Breakdown Spectroscopy and High-Resolution Laser Ablation-ICP-MS Mapping

The work presented herein employs two laser-based analytical techniques (laser-induced breakdown spectroscopy (LIBS) and laser ablation – inductively coupled plasma – mass spectrometry (LA-ICP-MS)) to spatially determine the elemental and isotopic composition of uranium bearing minerals. Uniquely, this work leverages the high-speed applicability of LIBS to “screen” the sample(s) for their elemental constituents. After determining the location of the uranium inclusions (via LIBS), high-resolution LA-ICP-MS was employed to further characterize the inclusions. The high-resolution (sub-µm) capabilities of LA-ICP-MS were able to extract important information from the uranium minerals including discerning its chemical form (e.g., finchite from carnotite, Sr- and K-bearing uranyl vanadates, respectively) as well as their 235 U/ 238 U isotopic composition. This approach, LIBS followed by LA-ICP-MS, significantly reduces the analysis time (~95 %) in comparison to employing a LA-ICP-MS only approach. Furthermore, this work presented a novel approach to analyzing inclusions via a particle/inclusion analysis tool which is commercially available within the iolite 4 software. This tool allowed for a more accurate characterization of the isotopic distribution of the inclusions, as well as allowing for rapid sizing of the inclusions. Finally, this analytical approach could readily be applied to other sample types in which the target species (e.g., µm-sized inclusions) are embedded in complex matrices (e.g., cm-sized samples).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plasma Assisted Combustion and Chemical Processing: Chapter 9 - Plasma Diagnostics

Plasma dynamics and chemistry have a broad range of timescales from picoseconds to milliseconds. In addition, it involves nonequilibrium energy transfer between electrons, ions, electronically and vibrationally excited states, radicals, intermediate species, and reactants and products as well as surface charges and chemistry. To understand plasma physics and chemistry, it is essential to conduct time and space resolved, quantitative detection of nonequilibrium temperature distributions, electron energy and number density, electric field, and species concentrations. There are enormous publications and review articles on this subject. The focus of this chapter is to be placed on the most recent progress in gas phase plasma properties and chemistry, especially on optical emission spectroscopy, laser absorption spectroscopy, Faraday rotational spectroscopy, Raman and Thompson scattering, femtosecond and picosecond (fs/ps) coherent anti-Stokes Raman scattering (CARS) spectroscopy, and electric field-induced second harmonic generation methods.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rotational spectroscopy at the Jet Propulsion Laboratory

Environmental monitoring, atmospheric remote sensing and astrophysical studies promoted by NASA require a strong basis of spectroscopic information. The rotational spectroscopy capabilities at NASAs Jet Propulsion Laboratory (JPL) are currently maintained for the measurement of key mission priorities that enable modeling and retrieval of geophysical data from the atmosphere as well as validation of the space-borne instruments in the Earth Observing System, particularly the Microwave Limb Sounder. Rotational spectra are measured using a variety of spectroscopic techniques including pulsed-beam Fourier transform microwave spectroscopy (at CalTech); millimeter wavelength Stark spectroscopy; millimeter, submillimeter and THz FM spectroscopy; laser sideband spectroscopy and Fourier Transform far-infrared spectroscopy. Remote measurements of atmospheric rotational spectra are made using two limb-sounder instruments in the submillimeter and THz. Recent advances in the direct synthesis of THz radiation that enable more efficient laboratory science will be presented. Software for comprehensive and systematic study of different molecular systems is maintained at JPL, the software is freely available via http://spec.jpl.nasa.gov and is used by our group to create and sustain the JPL spectral line catalog also available online.

molecular spectroscopy↗

Quantum-cascade-laser-absorption-spectroscopy diagnostic for temperature, pressure, and NO X 2 Π 1/2 at 500 kHz in shock-heated air at elevated pressures

The design, validation, and application of a quantum-cascade-laser-absorption-spectroscopy diagnostic for measuring gas temperature, pressure, and nitric oxide (NO) in high-temperature air are presented. A distributed-feedback quantum-cascade laser (QCL) centered near 1976 c m − <#comment/> 1 was used to scan across two transitions of NO in its ground electronic state ( X 2 Π <#comment/> 1 / 2 ). A measurement rate of 500 kHz was achieved using a single QCL by: (1) performing current modulation through a bias-tee, and (2) targeting closely spaced transitions with a large difference in lower-state energy. The diagnostic was validated in a mixture of 95% argon and 5% NO, which was shock-heated to ≈ <#comment/> 2000 to 3700 K. The average mean percent differences between laser-absorption-spectroscopy (LAS) measurements and predictions from shock-jump relations for temperature, pressure, and NO mole fraction were 3.1%, 4.1%, and 6.5%, respectively. The diagnostic was then applied to characterize shock-heated air at high temperatures (up to ≈ <#comment/> 5500 K ) and high pressures (up to 12 atm) behind either incident or reflected shocks. The LAS measurements were compared to theoretical predictions from shock-jump relations, pressure sensors mounted in the wall of the shock tube, and equilibrium values of the NO mole fraction. The average mean percent differences between LAS measurements and their aforementioned reference values were 3.2%, 10.8%, and 10.4% for temperature, pressure, and NO mole fraction, respectively. Last, a comparison between a measured NO mole fraction time history and a time-stepped homogeneous reactor simulation performed using two different chemical kinetics mechanisms is presented.

Gilvey, Jonathan J. (ORCID:0000000317664383)↗

Hollow waveguide cavity ringdown spectroscopy

Laser light is confined in a hollow waveguide between two highly reflective mirrors. This waveguide cavity is used to conduct Cavity Ringdown Absorption Spectroscopy of loss mechanisms in the cavity including absorption or scattering by gases, liquid, solids, and/or optical elements.

Dreyer, Chris↗

Review of Tm and Ho Materials; Spectroscopy and Lasers

A review of Tm and Ho materials is presented, covering some fundamental aspects on the spectroscopy and laser dynamics in both single and co-doped systems. Following an introduction to 2- m lasers, applications and historical development, the physics of quasi-four level lasers, energy transfer and modeling are discussed in some detail. Recent developments in using Tm lasers to pump Ho lasers are discussed, and seen to offer some advantages over conventional Tm:Ho lasers. This article is not intended as a complete review, but as a primer for introducing concepts and a resource for further study.

Walsh, Brian M.↗

Intracavity Dye-Laser Absorption Spectroscopy (IDLAS) for application to planetary molecules

Time-resolved, quasi-continuous wave, intracavity dye-laser absorption spectroscopy is applied to the investigation of absolute absorption coefficients for vibrational-rotational overtone bands of water at visible wavelengths. Emphasis is placed on critical factors affecting detection sensitivity and data analysis. Typical generation-time dependent absorption spectra are given.

Lang, Todd M.↗

An experiment concept to measure stratospheric trace constituents by Laser Heterodyne Spectroscopy

The concept and techniques of a Laser Heterodyne Spectrometer experiment for measuring the vertical profiles of several stratospheric trace gases are discussed. The goal of the experiment is to develop a laser heterodyne receiver capable of measuring 2-4 gases simultaneously from Spacelab and, ultimately, from free-flying platforms. Sensitivity analyses are currently being performed for tenuous molecules such as ClO, ClONO2, NOCl, HO2, H2O2, and N2O5, although the capability exists for measuring more abundant gases, such as O3, HNO3, N2O, NO2, and CH4. Results indicate that O3 and ClO vertical profiles can be measured with an accuracy equal to or better than 95% and 80%, respectively, over the total profile. Laboratory measurements of the performance characteristics of the local oscillator and heterodyne detector are discussed with reference to 'excess-noise' and Doppler-shift effects.

Allario, F.↗

Elemental fractionation in aerosol laser-induced breakdown spectroscopy with nanosecond and femtosecond laser ablation

For the purpose of realizing atmospheric radiation plume tracking, laser-induced breakdown spectroscopy (LIBS) was performed to characterize Cs atomic emissions from airborne nanoparticles in a binary particle matrix using nanosecond and femtosecond laser ablation. As a surrogate to multi-element nuclear fallout particulates, both Cs and Na solutions were mixed with Cu at a 1:1.45 M concentration ratio and aerosolized to study elemental fractionation in atomic emissions, revealing Na I resonance emissions are enhanced whereas Cs I resonance emissions are reduced with Cu present despite sharing similar electronic and chemical properties. Femtosecond laser ablation reduced elemental fractionation effects by more than 50% while retaining the same temporal fractionation trends for Cs and Na. The origin of elemental fractionation in aerosol LIBS was further investigated using Al and Ti aerosols which revealed that the particle matrix induces changes to the local plasma temperature, population of atomic states, and subsequent molecular association and emission.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration-free analysis of Li isotope ratios using laser ablation and laser absorption spectroscopy

We introduce a rapid, calibration-free, all-optical method for high-precision lithium isotope ratio measurements in solid materials using laser ablation combined with tunable laser absorption spectroscopy. A new asynchronous acquisition method is used to acquire time-resolved, high-resolution spectra of the 6Li and 7Li D1 and D2 transitions near 671 nm. Isotope ratios and atomic column densities are extracted from measured spectra via a physics-based fitting model including hyperfine structure. Under 1 Torr air, spectra recorded = 0.75 ms after plasma onset exhibit narrow linewidths corresponding to Doppler temperatures = 400 K, enabling resolution of the isotope peaks with high signal-to-noise ratios. Analysis of LiAlO2 samples with varying 6Li:7Li ratios demonstrates isotopic precisions of 0.6–1.7% for spectra acquired in 30 s. Isotope ratios determined from the spectral fits show accuracy within –0.3% to –1.7% of reference ICP-MS measurements without requiring calibration to external standards. By eliminating sample preparation and enabling spatially resolved isotopic mapping, this method offers a rapid analysis approach to lithium isotope determination in solid materials relevant to nuclear energy, safeguards, and geochemistry.

Phillips, Mark C.↗

Laser Optogalvanic Spectroscopy pf Neon and Argon in a Discharge Plasma and its Significance for Microgravity Combustion

A detailed study of combustion mechanisms in flames, employing laser-based diagnostics, has provided good knowledge and understanding of the physical phenomena, and led to better characterization of the dynamical and chemical combustion processes, both under low-gravity (in space) and normal gravity (in ground based facilities, e.g. drop towers). Laser induced fluorescence (LIF), laser-induced incandescence (LII) and LIF thermometry have been widely used to perform nonintrusive measurements and to better understand combustion phenomena. Laser optogalvanic (LOG) spectroscopy has well-established applications in ion mobility measurements, atomic and molecular spectroscopy, ionization rates, recombination rates, velocity measurements and as a combustion probe for trace element detection. Absorption spectra of atomic and molecular species in flames can be obtained via LOG spectroscopy by measuring the voltage and current changes induced by laser irradiation. There are different kinds of processes that contribute to a discharge current, namely: (1) electron impact ionization, (2) collisions among the excited atoms of the discharge species and (3) Penning ionization. In general, at higher discharge currents, the mechanism of electron impact ionization dominates over Penning ionization, whereby the latter is hardly noticeable. In a plasma, whenever the wavelength of a laser coincides with the absorption of an atomic or molecular species, the rate of ionization of the species momentarily increases or decreases due to laser-assisted acceleration of collisional ionization. Such a rate of change in the ionization is monitored as a variation in the transient current by inserting a high voltage electrode into the plasma. Optogalvanic spectroscopy in discharges has been useful for characterizing laser line-widths and for providing convenient calibration lines for tunable dye lasers in the ultraviolet, visible and infrared wavelength regions. Different kinds of quantitative information, such as the electron collisional ionization rate, can be extracted from the complex processes occurring within the discharge. In the optogalvanic effect (OGE), there is no problem of overlap from background emissions, and hence even weak signals can be detected with a high signal-to-noise ratio, which makes the optogalvanic effect sensitive enough to resolve vibrational changes in molecular bonds and differences in energy levels brought about by different electron spins. For calibration purposes, neon and argon gaseous discharges have been employed most extensively, because these gases are commonly used as buffer gases within hollow-cathode lamps and provide an acceptable density of calibration lines. In the present work, our main aim has been to understand the dominant physical processes responsible for the production of the OGE signal, based on the extensive time resolved optogalvanic waveforms recorded, and also to extract quantitative information on the rates of excited state collisional processes.

Misra, Prabhakar↗