Search NASA⌕ Search

SEARCH · Search NASA

Results for “LC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A Concept of Plasma Wake Field Acceleration Linear Collider (PWFA-LC)

Plasma Wake-Field Acceleration (PWFA) has demonstrated acceleration gradients above 50 GeV/m. Simulations have shown drive/witness bunch configurations that yield small energy spreads in the accelerated witness bunch and high energy transfer efficiency from the drive bunch to the witness bunch, ranging from 30% for a Gaussian drive bunch to 95% for a shaped longitudinal profile. These results open the opportunity for a linear collider that could be compact, efficient and more cost effective that the present microwave technologies. A concept of a PWFA-based Linear Collider (PWFA-LC) has been developed and is described in this paper. The drive beam generation and distribution, requirements on the plasma cells, and optimization of the interaction region parameters are described in detail. The R&D steps needed for further development of the concept are also outlined.

43 PARTICLE ACCELERATORS↗

IsoForma: An R Package for Quantifying and Visualizing Positional Isomers in Top-Down LC-MS/MS Data

Proteoforms, the different forms of a protein with sequence variations including post-translational modifications (PTMs), execute vital functions in biological systems such as cell signaling and epigenetic regulation. Precisely defining the stoichiometry of PTMs has been challenging because, in the widely used bottom-up proteomics methods, the detection occurs at the peptide level and thus the link between peptides and their specific modification site is lost, resulting in proteoform ambiguity. Advances in top-down mass spectrometry (MS) technology have permitted the direct characterization of intact proteoforms and their exact number of modification sites, allowing for the relative quantification of positional isomers (PI). Proteins with positional isomers refers to proteoforms with identical total mass and set of modifications but varying PTM site combinations. The relative abundance of PI can be estimated by matching proteoform-specific fragment ions to top-down tandem MS (MS2) data to localize and quantify modifications. However, current approaches heavily rely on manual annotation. Here, we present IsoForma, an open-source R package for relative quantification of PI within a single tool. We benchmarked IsoForma’s performance against two existing workflows and highlight the similarity of the results and improvements in speed. Overall, IsoForma provides a streamlined process, reduces the time of conducting isoform-based analyses, and offers an essential framework for developing customized proteoform analysis workflows. Finally, the software is open source and available at https://github.com/EMSL-Computing/isoforma-lib.

59 BASIC BIOLOGICAL SCIENCES↗

Online collection of LC effluent as droplets for automatic injection into ICP-MS

A sample introduction technique was developed to allow for online, dropwise injection of effluent into a mass spectrometer (MS). This allowed for the coupling of chromatography systems that were not driven by pumps without altering the set-up or separation performance. This capability combined the benefits of coupling separation and measurement while also enabling accurate chromatographic evaluation that would generally be performed offline. The incorporation of a flowing rinse into the system made dropwise resolution possible for any liquid capable of forming drops under ambient conditions. The technique was demonstrated utilizing gas pressurized extraction chromatography (GPEC) and inductively coupled plasma-time-of-flight mass spectrometry (ICP-TOFMS) to illustrate the qualitative applications for rapid separation development and procedure evaluation. This method's quantitative applications were evaluated using single and double isotope dilution mass spectrometry (IDMS) with an external mass bias correction to measure analytes across entire elutions including volumes as small as single drops. In conclusion, the total neodymium values afforded by both single and double IDMS were within the uncertainty of the calculated value for evaluation of full elution peaks and for most of the single drops analyzed that reached above 10k cps Nd-144.

GPEC↗

Recommendation for the Feasibility of more Compact LC Damping Rings

As part of the international Linear Collider (ILC) collaboration, we have compared the electron cloud (EC) effect for different Damping Ring (DR) designs respectively with 6.4 km and 3.2 km circumference and investigated the feasibility of a shorter damping ring with respect to the electron cloud build-up and related beam instability. The studies for a 3.2 km ring were carried out with beam parameters of the ILC Low Power option. A reduced damping ring circumference has been proposed for the new ILC baseline design SB2009 [1] and would allow to considerably reduce the number of components, wiggler magnets and costs. We discuss the impact of the proposed operation of the ILC at high repetition rate 10 Hz and address the necessary modifications for the DRs. We also briefly discuss the plans for future studies including the luminosity upgrade option with shorter bunch spacing, the evaluation of mitigations and the integration of the CesrTA results into the Damping Ring design.

43 PARTICLE ACCELERATORS↗

Mixed-Isotope Labeling with LC-IMS-MS for Characterization of Protein–Protein Interactions by Chemical Cross-Linking

Chemical cross-linking of proteins followed by proteolysis and mass spectrometric analysis of the resulting cross-linked peptides can provide insights into protein structure and protein-protein interactions. However, cross-linked peptides are by necessity of low stoichometry and have different physicochemical properties than linear peptides, routine unambiguous identification of the cross-linked peptides has remained difficult. To address this challenge, we demonstrated the use of liquid chromatography and ion mobility separations coupled with mass spectrometry in combination with a heavy-isotope labeling method. The combination of mixed-isotope cross-linking and ion mobility provided unique and easily interpretable spectral multiplet features for the intermolecular cross-linked peptides. Application of the method to two different homodimeric proteins - SrfN, a virulence factor from Salmonella Typhimurium and SO_2176, a protein of unknown function from Shewanella oneidensis- revealed several cross-linked peptides from both proteins that were identified with a low false discovery rate (estimated using a decoy approach). A greater number of cross-linked peptides were identified using ion mobility drift time information in the analysis than when the data were summed across the drift time dimension before analysis. The identified cross-linked peptides migrated more quickly in the ion mobility drift tube than the unmodified peptides.

59 BASIC BIOLOGICAL SCIENCES↗

Increasing Confidence of LC-MS Identifications by Utilizing Ion Mobility Spectrometry

Ion mobility spectrometry in conjunction with liquid chromatography separations and mass spectrometry offers a range of new possibilities for analyzing complex biological samples. To fully utilize the information obtained from these three measurement dimensions, informatics tools based on the accurate mass and time tag methodology were modified to incorporate ion mobility spectrometry drift times for peptides observed in human serum. A reference human serum database was created using 12,139 peptides, tracking the monoisotopic mass, liquid chromatography normalized elution time, and ion mobility spectrometry drift time(s) for each peptide. We demonstrate that the use of three dimensions for peak matching during the peptide identification process resulted in increased numbers of identifications and lower false discovery rates relative to the use of only the mass and normalized elution time dimensions.

Environmental Molecular Sciences Laboratory↗

Developing a peptide concatemer (PepCon) as a process control for LC-MS based proteomics

Quantitative concatenated peptide (QconCAT) technology is currently used for the absolute quantification of proteins of interest in a biological sample. It relies on artificially created proteins that are concatenations of different, isotopically labeled peptides. Because these isotopically labeled peptides are at a 1:1 ratio and correspond to naturally occurring peptides in the biological sample, each peptide can be used as a standard for the absolute quantitation of all proteins of interest at once. Although the QconCAT technology has utility for quantitation of known peptides in a mixture, it is not helpful for scientists who need a proteomics standard (1) that can be spiked into a protein mixture at an extremely low level, (2) that can be co-purified during sample fractionation, and (3) that is optimized for ESI used in mass spectrometry. Thus, there exists a need for an ideal standard protein that is large enough to behave as a protein but consists of multiple, concatenated copies of the same peptide, which, upon digestion, amplifies (e.g., >10-fold) into a detectable peptide species. Here, this technical report describes the development of “PepCon”, a peptide concatemer that fulfills this unmet need.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗