SEARCH · Search NASA
Results for “LENGTH”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Comment on 'Hypersharp Resonant Capture of Neutrinos as a Laboratory Probe of the Planck Length'
A Comment on the Letter by R. S. Raghavan, [Phys. Rev. Lett. 102, 091804 (2009)].
Effects of Preplasma Scale Length and Laser Intensity on the Divergence of Laser-Generated Hot Electrons
Explore the source record for details and available documents.
Pseudo-merohedral twinning and noncrystallographic symmetry in orthorhombic crystals of SIVmac239 Nef core domain bound to different-length TCRζ fragments
P2{sub 1}2{sub 1}2{sub 1} crystals of SIV Nef core domain bound to a peptide fragment of the T-cell receptor ζ subunit exhibited noncrystallographic symmetry and nearly perfect pseudo-merohedral twinning simulating tetragonal symmetry. For a different peptide fragment, nontwinned tetragonal crystals were observed but diffracted to lower resolution. The structure was determined after assignment of the top molecular-replacement solutions to various twin or NCS domains followed by refinement under the appropriate twin law. HIV/SIV Nef mediates many cellular processes through interactions with various cytoplasmic and membrane-associated host proteins, including the signalling ζ subunit of the T-cell receptor (TCRζ). Here, the crystallization strategy, methods and refinement procedures used to solve the structures of the core domain of the SIVmac239 isolate of Nef (Nef{sub core}) in complex with two different TCRζ fragments are described. The structure of SIVmac239 Nef{sub core} bound to the longer TCRζ polypeptide (Leu51–Asp93) was determined to 3.7 Å resolution (R{sub work} = 28.7%) in the tetragonal space group P4{sub 3}2{sub 1}2. The structure of SIVmac239 Nef{sub core} in complex with the shorter TCRζ polypeptide (Ala63–Arg80) was determined to 2.05 Å resolution (R{sub work} = 17.0%), but only after the detection of nearly perfect pseudo-merohedral crystal twinning and proper assignment of the orthorhombic space group P2{sub 1}2{sub 1}2{sub 1}. The reduction in crystal space-group symmetry induced by the truncated TCRζ polypeptide appears to be caused by the rearrangement of crystal-contact hydrogen-bonding networks and the substitution of crystallographic symmetry operations by similar noncrystallographic symmetry (NCS) operations. The combination of NCS rotations that were nearly parallel to the twin operation (k, h, −l) and a and b unit-cell parameters that were nearly identical predisposed the P2{sub 1}2{sub 1}2{sub 1} crystal form to pseudo-merohedral twinning.
Functional heterologous expression of an engineered full length CipA from Clostridium thermocellum in Thermoanaerobacterium saccharolyticum
Explore the source record for details and available documents.
Experimental Investigation of the Effect of Vertical-tail Size and Length of Fuselage Shape and Length on the Static Lateral Stability Characteristics of a Model with 45 Degree Sweptback Wing and Tail Surfaces
Explore the source record for details and available documents.
Using {sup 18}F-Fluorodeoxyglucose Positron Emission Tomography to Estimate the Length of Gross Tumor in Patients With Squamous Cell Carcinoma of the Esophagus
Purpose: To determine the optimal method of using {sup 18}F-fluorodeoxyglucose positron emission tomography (FDG-PET) to estimate gross tumor length in esophageal carcinoma. Methods and Materials: Thirty-six patients with esophageal squamous cell carcinoma treated with radical surgery were enrolled. Gross tumor volumes (GTVs) were delineated using three different methods: visual interpretation, standardized uptake value (SUV) 2.5, and 40% of maximum standard uptake value (SUV{sub max}) on FDG-PET imaging. The length of tumors on PET scan were measured and recorded as Length{sub vis}, Length{sub 2.5}, and Length{sub 40}, respectively, and compared with the length of gross tumor in the resected specimen (Length{sub gross}). All PET data were reviewed again postoperatively, and the GTV was delineated using various percentages of SUV{sub max}. The optimal-threshold SUV was generated when the length of PET matched the Length{sub gross}. Results: The mean ({+-}SD) Length{sub gross} was 5.48 {+-} 1.98 cm. The mean Length{sub vis}, Length{sub 2.5}, and Length{sub 40} were 5.18 {+-} 1.93 cm, 5.49 {+-} 1.79 cm, and 4.34 {+-} 1.54 cm, respectively. The mean Length{sub vis} (p = 0.123) and Length{sub 2.5} (p = 0.957) were not significantly different from Length{sub gross}, and Length{sub 2.5} seems more approximate to Length{sub gross.} The mean Length{sub 40} was significantly shorter than Length{sub gross} (p < 0.001). The mean optimal threshold was 23.81% {+-} 11.29% for all tumors, and it was 19.78% {+-} 8.59%, 30.92% {+-} 12.28% for tumors {>=}5 cm, and <5 cm, respectively (p = 0.009). The correlation coefficients of the optimal threshold were -0.802 and -0.561 with SUV{sub max} and Length{sub gross}, respectively. Conclusions: The optimal PET method to estimate the length of gross tumor varies with tumor length and SUV{sub max}; an SUV cutoff of 2.5 provided the closest estimation in this study.
Measuring the giant radio galaxy length distribution with the LoTSS
Many massive galaxies launch jets from the accretion disk of their central black hole, but only ~10 3 instances are known in which the associated outflows form giant radio galaxies (GRGs, or giants): luminous structures of megaparsec extent that consist of atomic nuclei, relativistic electrons, and magnetic fields. Large samples are imperative to understanding the enigmatic growth of giants, and recent systematic searches in homogeneous surveys constitute a promising development. For the first time, it is possible to perform meaningful precision statistics with GRG lengths, but a framework to do so is missing. We measured the intrinsic GRG length distribution by combining a novel statistical framework with a LOFAR Two-metre Sky Survey (LoTSS) sample of freshly discovered giants. In turn, this allowed us to answer an array of questions on giants. For example, we can now assess how rare a 5 Mpc giant is compared with one of 1 Mpc, and how much larger – given a projected length – the corresponding intrinsic length is expected to be. Notably, we can now also infer the GRG number density in the Local Universe. We assumed the intrinsic GRG length distribution to be Paretian (i.e. of power-law form) with tail index ξ, and predicted the observed distribution by modelling projection and selection effects. To infer ξ, we also systematically searched the LoTSS for hitherto unknown giants and compiled the largest catalogue of giants to date. We show that if intrinsic GRG lengths are Pareto distributed with index ξ, then projected GRG lengths are also Pareto distributed with index ξ. Selection effects induce curvature in the observed projected GRG length distribution: angular length selection flattens it towards the lower end, while surface brightness selection steepens it towards the higher end. We explicitly derived a GRG’s posterior over intrinsic lengths given its projected length, laying bare the ξ dependence. We also discovered 2060 giants within LoTSS DR2 pipeline products; our sample more than doubles the known population. Spectacular discoveries include the largest, second-largest, and fourth-largest GRG known (l p = 5.1 Mpc, l p = 5.0 Mpc, and l p = 4.8 Mpc), the largest GRG known hosted by a spiral galaxy (l p = 2.5 Mpc), and the largest secure GRG known beyond redshift 1 (l p = 3.9 Mpc). We increase the number of known giants whose angular length exceeds that of the Moon from 10 to 23; among the discoveries is the angularly largest known radio galaxy in the Northern Sky, which is also the angularly largest known GRG ($\phi$ = 2°). Combining theory and data, we determined that intrinsic GRG lengths are well described by a Pareto distribution, and measured the index ξ = –3.5 ± 0.5. This implies that, given its projected length, a GRG’s intrinsic length is expected to be just 15% larger. Finally, we determined the comoving number density of giants in the Local Universe to be n GRG = 5 ± 2(100 Mpc) –3 . We developed a practical mathematical framework that elucidates the statistics of giant radio galaxy lengths. Through a LoTSS search, we also discovered 2060 new giants. By combining both advances, we determined that intrinsic GRG lengths are well described by a Pareto distribution with index ξ = –3.5 ± 0.5, and that giants are truly rare in a cosmological sense: most clusters and filaments of the Cosmic Web are not currently home to a giant. Thus, our work yields new observational constraints for analytical models and simulations featuring radio galaxy growth.
Root responses to elevated CO 2 , warming and irrigation in a semi-arid grassland: Integrating biomass, length and life span in a 5-year field experiment
Plant roots mediate the impacts of environmental change on ecosystems, yet knowledge of root responses to environmental change is limited because few experiments evaluate multiple environmental factors and their interactions. Inferences about root functions are also limited because root length dynamics are rarely measured. Using a 5-year experiment in a mixed-grass prairie, we report the responses of root biomass, length and life span to elevated carbon dioxide (CO 2 ), warming, elevated CO 2 and warming combined, and irrigation. Root biomass was quantified using soil cores and root length dynamics were assessed using minirhizotrons. By comparing root dynamics with published results for soil resources and above-ground productivity, we provide mechanistic insights into how climate change might impact grassland ecosystems. In the upper soil layer, 0–15 cm depth, both irrigation and elevated CO 2 alone increased total root length by twofold, but irrigation decreased root biomass and elevated CO 2 had only small positive effects on root biomass. The large positive effects of irrigation and elevated CO 2 alone on total root length were due to increases in both root length production and root life span. The increased total root length and life span under irrigation and elevated CO 2 coincided with apparent shifts from water limitation of plant growth to nitrogen limitation. Warming alone had minimal effects on root biomass, length and life span in this shallow soil layer. Warming and elevated CO 2 combined increased root biomass and total root length by c. 25%, but total root length in this treatment was lower than expected if the effects of CO 2 and warming alone were additive. Treatment effects on total root length and root life span varied with soil depth and root diameter. Synthesis. Sub-additive effects of CO 2 and warming suggest studies of elevated CO 2 alone might overestimate the future capacity of grassland root systems to acquire resources. In this mixed-grass prairie, elevated CO 2 with warming stimulated total root length and root life span in deeper soils, likely enhancing plant access to more stable pools of growth-limiting resources, including water and phosphorus. Therefore, these root responses help explain previous observations of higher, and more stable, above-ground productivity in these projected climate conditions.
Association of cadmium and arsenic exposure with salivary telomere length in adolescents in Terai, Nepal
Background: Cadmium and arsenic are ubiquitous metals commonly found in the environment which can harm human health. A growing body of research shows telomere length as a potential biomarker of future disease risk. Few studies have examined the effects of metals on telomere length and none have focused on adolescents. Objectives: In this study, the impact of cadmium and arsenic on salivary telomere length was studied in adolescents in Terai, Nepal. Methods: Adolescents aged 12–16 years old (n=351)were recruited where questionnaire interviews and both saliva and urine collection took place. Telomere length was determined by quantitative polymerase chain reaction using DNA extracted from saliva. Urinary cadmium and arsenic concentration were measured by inductively coupled plasma mass spectrometry. Multivariable linear regression was used to examine associations between urinary metals and salivary telomere length. Results: The geometric means and standard deviations of cadmium and arsenic were 0.33±0.33 μg/g creatinine and 196.0±301.1 μg/g creatinine, respectively. Urinary cadmium concentration was negatively associated with salivary telomere length after adjustment for confounders (β=−0.24, 95% CI −0.42,−0.07). Arsenic showed positive associations with telomere length but did not reach statistical significance. Conclusions: This is the first study to demonstrate that cadmium may shorten adolescent telomeres, even at exposure levels that may be considered low. These results agree with prior experimental and adult epidemiological studies, and also help identify the mechanism of DNA damage by cadmium. This study expanded current evidence on the harmful effects of cadmium exposure on telomere length even to adolescents. - Highlights: • This is the first study examining metal exposure on telomere length in adolescents. • Urinary cadmium levels were similar to non-industrially polluted levels in Asia. • Urinary arsenic levels were as high as groundwater arsenic polluted areas in Asia. • Urinary cadmium was negatively associated with salivary telomere length. • Urinary arsenic was not significantly associated with salivary telomere length.
Quantifying the hierarchy of structural and mechanical length scales in granular systems
Continuum modeling of granular media is made possible by the existence of a length scale at and above which grain-resolved properties can be meaningfully homogenized. Progress has been made in identifying such length scales relevant to local structural properties such as porosity. However, a systematic analysis of scales above which different mechanical properties can be homogenized has yet to emerge. Here, X-ray tomography and 3D X-ray diffraction data are examined to identify such length scales. The data was obtained in-situ in compressed granular materials with rigid and flexible confinement. The experimental data are supplemented with validated discrete element simulations which examine different system sizes and different boundary conditions. Overall, our study reveals a hierarchy in the length scales of granular solids, with lengths governing structural variables being the shortest, lengths of stress variables being intermediate, and lengths of energy dissipation being the longest. All structural and mechanical length scales obey a power law based on the theory of Geostatistics, implying that the length scales can be found by analyzing samples significantly smaller than the length scales themselves. The length scales are also found to be sensitive to boundary conditions, implying that they are extrinsic features of granular media.
SU-F-I-40: Impact of Scan Length On Patient Dose in Abdomen/pelvis CT Diagnosis
Purpose: To analysis the impact of scan length on patient doses in abdomen/pelvis CT diagnosis of each hospital. Methods: Scan length of 7 hospitals from abdomen/pelvis CT diagnosis was surveyed in Korea. Surveyed scan lengths were additional distance above diaphragm and distance below pubic symphysis except for standard scan range between diaphragm and pubic symphysis. Patient dose was estimated for adult male and female according to scan length of each hospital. CT-Expo was used to estimate the patient dose under identical equipment settings (120 kVp, 100 mAs, 10 mm collimation width, etc.) except scan length. Effective dose was calculated by using tissue weighting factor of ICRP 103 recommendation. Increase rate of effective dose was calculated comparing with effective dose of standard scan range Results: Scan lengths of abdomen/pelvis CT diagnosis of each hospital were different. Also effective dose was increased with increasing the scan length. Generally increasing the distance above diaphragm caused increase of effective dose of male and female, but increasing the distance below pubic symphysis caused increase of effective dose of male. Conclusion: We estimated the patient dose according to scan length of each hospital in abdomen/pelvis CT diagnosis. Effective dose was increased by increasing the scan length because dose of organs with high tissue weighting factor such as lung, breast, testis were increased. Scan length is important factor on patient dose in CT diagnosis. If radiologic technologist interested in patient dose, decreasing the unnecessary scan length will decrease the risk of patients from radiation. This research was supported by a grant of the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea (grant number: HI13C0004).
Efficient Measurement of Length Distribution of 1D Nanoparticles in Solution via Optical Polarimetry
The efficient measurement of the length distribution of nanotubes, nanowires, and other one-dimensional (1D) nanoparticles in solution is important to enable their incorporation into materials and devices and to optimize their processing for properties of interest, such as thermal/electrical conductivity or mechanical strength, in suspensions and composites. We report an electric-field (E-field)-assisted optical-polarimetry technique to measure the length distribution of ensembles of high-aspect-ratio particles in dilute suspension. The degree of alignment of polarizable 1D particles suspended in a fluid under Brownian motion explicitly depends on the E-field strength and the particle length. We show that it is possible to extract the length distribution of 1D nanoparticles suspended in an insulating fluid by applying a range of E-fields and using optical polarimetry to measure the corresponding alignment order parameter. Notably, the method is relatively insensitive to the diameter of the 1D particles, which can be poorly known or vary within a sample. The technique is validated with silver nanowires and carbon nanotubes of known lengths, as well as polymer-depletion-length-separated single-wall carbon nanotube samples with length distributions independently measured with analytical ultracentrifugation. Finally, we demonstrate the ability of the optical-polarimetry technique to quantify changes in the length distribution of ultranarrow, sub-nanometer-diameter single-wall carbon nanotubes under different types and durations of ultrasonication. Within its range of applicability (polarizable 1D nanoparticles in the 0.5 to 15 μm length range, constrained by the voltage stability of the media and the suspended particles), the E-field-assisted optical-polarimetry method is a particularly efficient and accurate method to measure the length distribution of nanowires and nanotubes in suspension.
Charge Carrier Diffusion Length Determination in 4H-SiC Schottky Alpha Detectors
When developing semiconductor radiation detectors detailed characterization of the detector behavior is required. The ability of a semiconductor radiation detector to collect the charge liberated by incident ionizing radiation is a critical characteristic. Several factors influence the charge collection efficiency of a semiconductor radiation detector, including electron-hole trapping, applied electric field strength, and dopant concentrations and dimensions of low doped regions. Applying a reverse bias electric potential to a low doped semiconductor region creates a free charge carrier depleted region and establishes an electric field which can remove subsequently freed charge in the form of an electrical signal. When ionizing radiation is incident upon a semiconductor electron-hole pairs are generated. These charge carriers are created along the path of the ionizing radiation regardless of the doping concentration. However, only the charge freed in the low doped epitaxial region of a detector will be collected as a result of the applied electric field. When the electric field is insufficient to develop a depleted region equal to or larger than the range of the ionizing radiation in the detector material some charge freed by the ionizing radiation outside of the sensitive region will be lost, thus potentially resulting in less than complete charge collection. The incomplete collection of charge complicates the analysis of the incident particle energy spectrum. Charge freed in the highly doped bulk region beyond the low doped epitaxial region may diffuse back into the low doped depleted region and be subsequently included in the integral pulse. The amount of charge collected as a result of this diffusion mechanism is dependent upon the diffusion length of the charge carriers in the material. The diffusion length is subsequently dependent on the material properties of the detector including the number of defects, trapping centers, and temperature. In order to fully characterize the properties of 4H-SiC as a radiation detector the diffusion length was calculated by adjusting the theoretical diffusion length value used in the calculation of the charge collection efficiency to agree with empirically observed charge collection efficiencies. The discrepancy between the observed and theoretical charge collection efficiency at 50 to 150 volts applied bias indicates an unexplained charge collection phenomenon which is contributing to the larger than predicted charge collection efficiency of the detectors. This voltage range corresponds to an intermediate applied bias, indicating that either the theoretical depletion width is too short, the diffusion length varies with the composition of the region that the charge carriers are diffusing through, or some other phenomenon is involved. If the charge carrier diffusion length varies depending on whether or not the diffusing charge is freed in unbiased epitaxy or bulk layer, then a function describing the variation of the diffusion layer could be determined by measuring the diffusion length at the applied voltages used previously, but over a range of epitaxial layer thicknesses. Future work includes the characterization of the effects of high temperature operation on the diffusion length of 4H-SiC in addition to measuring the effects of varying energy alpha emitter electrodeposition on the observed diffusion length. Additional Schottky barrier contacts, namely those with a nickel-platinum contact, will be tested in various sizes which have been developed in order to eliminate certain failure mechanisms and explore the potential effects of Schottky contact size on charge collection efficiency. (authors)
SU-C-12A-06: A Universal Definition for CT Irradiated Length
Purpose: The length of scan shown or calculated from the console is the distance between the center of the starting and ending images. The irradiated length for such a set of images can vary substantially from this distance, depending on the acquisition mode. We propose that the rise to equilibrium function h(λ) be used to uniquely define an irradiated length independent of the details of the scanning process. This method also seamlessly accommodates recent developments in active collimation. Method: h(λ) is determined along the central axis of a long cylindrical phantom, ideally from integration of the dose spread function. For practical reasons h(λ) may be approximated from helical scans with real-time dose rate measurements or from a series of central dose measurements using finite irradiated length exposures. For a particular scan then, the irradiated length λ is calculated from a central dose measurement of h and then applying the inverse function h(λ){sup -1}. Results: h(λ) was determined from measurements made in a prototype ICRU/TG200 phantom, 60 cm long and 30 cm in diameter. The resultant λ generally agreed with indicated scan length plus one beam width for axial and indicated scan length for helical scans if overscanning was accounted for. For most scanners, DLP/CTDIvol is a good measure of irradiated length allowing for another index of comparison. Conclusion: Central dose measurements with a small chamber along with the rise to equilibrium function h(λ) provide us with a robust and consistent means of determining scan length independent of the means of irradiation over a variety of scanners and scanning conditions. The method is limited to λ significantly less than the equilibrium.