Search NASA⌕ Search

SEARCH · Search NASA

Results for “LHD DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Equilibrium Reconstruction on the Large Helical Device

Equilibrium reconstruction is commonly applied to axisymmetric toroidal devices. Recent advances in computational power and equilibrium codes have allowed for reconstructions of three-dimensional fields in stellarators and heliotrons. We present the first reconstructions of finite beta discharges in the Large Helical Device (LHD). The plasma boundary and magnetic axis are constrained by the pressure profile from Thomson scattering. This results in a calculation of plasma beta without a-priori assumptions of the equipartition of energy between species. Saddle loop arrays place additional constraints on the equilibrium. These reconstruction utilize STELLOPT, which calls VMEC. The VMEC equilibrium code assumes good nested flux surfaces. Reconstructed magnetic fields are fed into the PIES code which relaxes this constraint allowing for the examination of the effect of islands and stochastic regions on the magnetic measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic configuration effects on TAE-induced losses and a comparison with the orbit-following model in the Large Helical Device

Fast-ion losses from Large Helical Device (LHD) plasmas due to toroidal Alfven eigenmodes (TAEs) were measured by a scintillator-based lost fast-ion probe (SLIP) to understand the loss processes. TAE-induced losses measured by the SLIP appeared in energy E ranges of around 50-180 keV with pitch angles. between 35 degrees-45 degrees, and increased with the increase in TAE amplitudes. Position shifts of the magnetic axis due to a finite plasma pressure led not only to an increase in TAE-induced losses but also to a stronger scaling of fast-ion losses on TAE amplitudes. Characteristics of the observed fast-ion losses were compared with a numerical simulation based on orbit-following models in which the TAE fluctuations are taken into account. The calculation indicated that the number of lost fast ions reaching the SLIP increased with the increase in the TAE amplitude at the TAE gap. Moreover, the calculated dependence of fast-ion loss fluxes on the fluctuation amplitude became stronger in the case of large magnetic axis shifts, compared with the case of smaller shifts, as was observed in the experiments. The simulation results agreed qualitatively with the experimental observations in the LHD.

Ogawa, K.↗

Stability optimization of energetic particle driven modes in nuclear fusion devices: the FAR3d gyro-fluid code

The development of reduced models provide efficient methods that can be used to perform short term experimental data analysis or narrow down the parametric range of more sophisticated numerical approaches. Reduced models are derived by simplifying the physics description with the goal of retaining only the essential ingredients required to reproduce the phenomena under study. This is the role of the gyro-fluid code FAR3d, dedicated to analyze the linear and nonlinear stability of Alfvén Eigenmodes (AE), Energetic Particle Modes (EPM) and magnetic-hydrodynamic modes as pressure gradient driven mode (PGDM) and current driven modes (CDM) in nuclear fusion devices. Such analysis is valuable for improving the plasma heating efficiency and confinement; this can enhance the overall device performance. The present review is dedicated to a description of the most important contributions of the FAR3d code in the field of energetic particles (EP) and AE/EPM stability. FAR3d is used to model and characterize the AE/EPM activity measured in fusion devices as LHD, JET, DIII-D, EAST, TJ-II and Heliotron J. In addition, the computational efficiency of FAR3d facilitates performing massive parametric studies leading to the identification of optimization trends with respect to the AE/EPM stability. This can aid in identifying operational regimes where AE/EPM activity is avoided or minimized. This technique is applied to the analysis of optimized configurations with respect to the thermal plasma parameters, magnetic field configuration, external actuators and the effect of multiple EP populations. In addition, the AE/EPM saturation phase is analyzed, taking into account both steady-state phases and bursting activity observed in LHD and DIII-D devices. The nonlinear calculations provide: the induced EP transport, the generation of zonal structures as well as the energy transfer towards the thermal plasma and between different toroidal/helical families. Finally, FAR3d is used to forecast the AE/EPM stability in operational scenarios of future devices as ITER, CFETR, JT60SA and CFQS as well as possible approaches to optimization with respect to variations in the most important plasma parameters.

Alfv én Eigenmodes↗

Wide dynamic range neutron flux monitor having fast time response for the Large Helical Device

A fast time response, wide dynamic range neutron flux monitor has been developed toward the LHD deuterium operation by using leading-edge signal processing technologies providing maximum counting rate up to ∼5 × 10{sup 9} counts/s. Because a maximum total neutron emission rate over 1 × 10{sup 16} n/s is predicted in neutral beam-heated LHD plasmas, fast response and wide dynamic range capabilities of the system are essential. Preliminary tests have demonstrated successful performance as a wide dynamic range monitor along the design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hydrogen emissions from peripheral plasmas in local island divertor and helical divertor configurations

Superdense core plasmas with a highly peaked electron density profile have been obtained in reduced recycling discharges in the Large Helical Device [O. Motojima et al., Phys. Plasmas 6, 1843 (1999)]. The polarization separation spectroscopy technique has been applied to characterize H{alpha} emissions in the peripheral region of superdense core plasmas. Fitting positions of the high intensity H{alpha} line are located just outside of the last closed flux surface in the local island divertor configuration. In the helical divertor configuration, high intensity emissions are observed around the inner and outer X points and along the divertor legs. In both configurations the hydrogen atoms have an inward velocity along the lines of sight.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhancement of cross-field transport into the private region of detached-divertor in Large Helical Device

The fluctuation of ion saturation currents in the attached- and detached-divertor plasmas of the Large Helical Device [Fujiwara et al., Nucl. Fusion 41, 1355 (2001)] has been measured using a Langmuir probe array embedded in a divertor plate. Analytical results indicate that these fluctuation properties differ considerably from each other; for instance, the mean value distribution expands to and positive spikes propagate toward a private region from the divertor leg in the detached-divertor. We investigated the magnetic field lines traced from probe electrodes by using the KMAG code [Nakamura et al., J. Plasma Fusion Res. 69, 41 (1993)], and it is then confirmed that the propagation direction of positive spikes corresponds to that predicted by the theory of blobby plasma transport. This phenomenon is expected to lead to the broadening of plasma particle and heat fluxes to the divertor plate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute intensity calibration of flat-field space-resolved extreme ultraviolet spectrometer using radial profiles of visible and extreme ultraviolet bremsstrahlung continuum emitted from high-density plasmas in Large Helical Device

A precise absolute intensity calibration of a flat-field space-resolved extreme ultraviolet (EUV) spectrometer working in wavelength range of 60-400 A is carried out using a new calibration technique based on radial profile measurement of the bremsstrahlung continuum in Large Helical Device. A peaked vertical profile of the EUV bremsstrahlung continuum has been successfully observed in high-density plasmas (n{sub e}{>=} 10{sup 14} cm{sup -3}) with hydrogen ice pellet injection. The absolute calibration can be done by comparing the EUV bremsstrahlung profile with the visible bremsstrahlung profile of which the absolute value has been already calibrated using a standard lamp. The line-integrated profile of measured visible bremsstrahlung continuum is firstly converted into the local emissivity profile by considering a magnetic surface distortion due to the plasma pressure, and the local emissivity profile of EUV bremsstrahlung is secondly calculated by taking into account the electron temperature profile and free-free gaunt factor. The line-integrated profile of the EUV bremsstrahlung continuum is finally calculated from the local emissivity profile in order to compare with measured EUV bremsstrahlung profile. The absolute intensity calibration can be done by comparing measured and calculated EUV bremsstrahlung profiles. The calibration factor is thus obtained as a function of wavelength with excellent accuracy. It is also found in the profile analysis that the grating reflectivity of EUV emissions is constant along the direction perpendicular to the wavelength dispersion. Uncertainties on the calibration factor determined with the present method are discussed including charge-coupled device operation modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neoclassical electron transport calculation by using {delta}f Monte Carlo method

High electron temperature plasmas with steep temperature gradient in the core are obtained in recent experiments in the Large Helical Device [A. Komori et al., Fusion Sci. Technol. 58, 1 (2010)]. Such plasmas are called core electron-root confinement (CERC) and have attracted much attention. In typical CERC plasmas, the radial electric field shows a transition phenomenon from a small negative value (ion root) to a large positive value (electron root) and the radial electric field in helical plasmas are determined dominantly by the ambipolar condition of neoclassical particle flux. To investigate such plasmas' neoclassical transport precisely, the numerical neoclassical transport code, FORTEC-3D [S. Satake et al., J. Plasma Fusion Res. 1, 002 (2006)], which solves drift kinetic equation based on {delta}f Monte Carlo method and has been applied for ion species so far, is extended to treat electron neoclassical transport. To check the validity of our new FORTEC-3D code, benchmark calculations are carried out with GSRAKE [C. D. Beidler et al., Plasma Phys. Controlled Fusion 43, 1131 (2001)] and DCOM/NNW [A. Wakasa et al., Jpn. J. Appl. Phys. 46, 1157 (2007)] codes which calculate neoclassical transport using certain approximations. The benchmark calculation shows a good agreement among FORTEC-3D, GSRAKE and DCOM/NNW codes for a low temperature (T{sub e}(0)=1.0 keV) plasma. It is also confirmed that finite orbit width effect included in FORTEC-3D affects little neoclassical transport even for the low collisionality plasma if the plasma is at the low temperature. However, for a higher temperature (5 keV at the core) plasma, significant difference arises among FORTEC-3D, GSRAKE, and DCOM/NNW. These results show an importance to evaluate electron neoclassical transport by solving the kinetic equation rigorously including effect of finite radial drift for high electron temperature plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A convergence study for the Laguerre expansion in the moment equation method for neoclassical transport in general toroidal plasmas

The dependence of neoclassical parallel flow calculations on the maximum order of Laguerre polynomial expansions is investigated in a magnetic configuration of the Large Helical Device [S. Murakami, A. Wakasa, H. Maassberg, et al., Nucl. Fusion 42, L19 (2002)] using the monoenergetic coefficient database obtained by an international collaboration. On the basis of a previous generalization (the so-called Sugama-Nishimura method [H. Sugama and S. Nishimura, Phys. Plasmas 15, 042502 (2008)]) to an arbitrary order of the expansion, the 13 M, 21 M, and 29 M approximations are compared. In a previous comparison, only the ion distribution function in the banana collisionality regime of single-ion-species plasmas in tokamak configurations was investigated. In this paper, the dependence of the problems including electrons and impurities in the general collisionality regime in an actual nonsymmetric toroidal configuration is reported. In particular, qualities of approximations for the electron distribution function are investigated in detail.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A reduced model for ion temperature gradient turbulent transport in helical plasmas

A novel reduced model for ion temperature gradient (ITG) turbulent transport in helical plasmas is presented. The model enables one to predict nonlinear gyrokinetic simulation results from linear gyrokinetic analyses. It is shown from nonlinear gyrokinetic simulations of the ITG turbulence in helical plasmas that the transport coefficient can be expressed as a function of the turbulent fluctuation level and the averaged zonal flow amplitude. Then, the reduced model for the turbulent ion heat diffusivity is derived by representing the nonlinear turbulent fluctuations and zonal flow amplitude in terms of the linear growth rate of the ITG instability and the linear response of the zonal flow potentials. It is confirmed that the reduced transport model is in a good agreement with nonlinear gyrokinetic simulation results for high ion temperature plasmas in the large helical device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear stability of magnetic islands in a rotating helical plasma

Coexistence of the forced magnetic reconnection by a resonant magnetic perturbation (RMP) and the curvature-driven tearing mode is investigated in a helical (stellarator) plasma rotated by helical trapped particle-induced neoclassical flows. A set of Rutherford-type equations of rotating magnetic islands and a poloidal flow evolution equation is revisited. Using the model, analytical expressions of criteria of spontaneous shrinkage (self-healing) of magnetic islands and sudden growth of locked magnetic islands (penetration of RMP) are obtained, where nonlinear saturation states of islands show bifurcation structures and hysteresis characteristics. Considering radial profile of poloidal flows across magnetic islands, it is found that the self-healing is driven by neoclassical viscosity even in the absence of micro-turbulence-induced anomalous viscosity. Effects of unfavorable curvature in stellarators are found to modify the critical values. The scalings of criteria are consistent with low-{beta} experiments in the large helical device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Up-down asymmetry measurement of tungsten distribution in large helical device using two extreme ultraviolet (EUV) spectrometers

Two space-resolved extreme ultraviolet spectrometers working in wavelength ranges of 10-130 Å and 30-500 Å have been utilized to observe the full vertical profile of tungsten line emissions by simultaneously measuring upper- and lower-half plasmas of LHD, respectively. The radial profile of local emissivity is reconstructed from the measured vertical profile in the overlapped wavelength range of 30-130 Å and the up-down asymmetry is examined against the local emissivity profiles of WXXVIII in the unresolved transition array spectrum. The result shows a nearly symmetric profile, suggesting a good availability in the present diagnostic method for the impurity asymmetry study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging polychromator for density measurements of polystyrene pellet cloud on the Large Helical Device

Experimental data on spatial distributions of a pellet cloud electron density are necessary for the development of many applications of pellet injection, namely, plasma fuelling, discharge control, and plasma diagnostics. An improved approach of electron density measurements inside the cloud of a polystyrene pellet ablating in hot plasma of the large helical device is described. Density values of (1-30) × 10{sup 16} cm{sup −3} depending on the background plasma parameters and distance from the solid pellet were measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multifrequency channel microwave reflectometer with frequency hopping operation for density fluctuation measurements in Large Helical Device

In order to measure the internal structure of density fluctuations using a microwave reflectometer, the broadband frequency tunable system, which has the ability of fast and stable hopping operation, has been improved in the Large Helical Device. Simultaneous multipoint measurement is the key issue of this development. For accurate phase measurement, the system utilizes a single sideband modulation technique. Currently, a dual channel heterodyne frequency hopping reflectometer system has been constructed and applied to the Alfven eigenmode measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Electrostatic detection of stainless steel dust particles for fusion applications

Dust accumulation inside next-step fusion devices poses a significant safety concern and dust diagnostics will be needed to assure safe operations. An electrostatic dust detection device has been successfully demonstrated in the National Spherical Torus Experiment, Tore Supra, and the Large Helical Device, and the detector's response to carbon particles was previously characterized in laboratory experiments. This paper presents laboratory results showing that detection of stainless steel particles at levels as low as several μg/cm{sup 2} is also possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study on in situ calibration for neutron flux monitor in the Large Helical Device based on Monte Carlo calculations

Neutron monitoring is important to manage safety of fusion experiment facilities because neutrons are generated in fusion reactions. Monte Carlo simulations play an important role in evaluating the influence of neutron scattering from various structures and correcting differences between deuterium plasma experiments and in situ calibration experiments. We evaluated these influences based on differences between the both experiments at Large Helical Device using Monte Carlo simulation code MCNP5. A difference between the both experiments in absolute detection efficiency of the fission chamber between O-ports is estimated to be the biggest of all monitors. We additionally evaluated correction coefficients for some neutron monitors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a high dynamic range spectroscopic system for observation of neutral hydrogen atom density distribution in Large Helical Device core plasma

We report development of a high dynamic range spectroscopic system comprising a spectrometer with 30% throughput and a camera with a low-noise fast-readout complementary metal-oxide semiconductor sensor. The system achieves a 10{sup 6} dynamic range (∼20 bit resolution) and an instrumental function approximated by a Voigt profile with Gauss and Lorentz widths of 31 and 0.31 pm, respectively, for 656 nm light. The application of the system for line profile observations of the Balmer-α emissions from high temperature plasmas generated in the Large Helical Device is also presented. In the observed line profiles, emissions are detected in far wings more than 1.0 nm away from the line center, equivalent to neutral hydrogen atom kinetic energies above 1 keV. We evaluate atom density distributions in the core plasma by analyzing the line profiles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Power and polarization monitor development for high power millimeter-wave

A new type monitor of power and polarization states of millimeter-waves has been developed to be installed at a miter-bend, which is a part of transmission lines of millimeter-waves, for electron cyclotron resonance heating on the Large Helical Device. The monitor measures amplitudes and phase difference of the electric field of the two orthogonal polarizations which are needed for calculation of the power and polarization states of waves. The power and phase differences of two orthogonal polarizations were successfully detected simultaneously.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗