Search NASA⌕ Search

SEARCH · Search NASA

Results for “LHP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

STS 87: Meal - Suit Up - Depart O&C - Launch Columbia On Orbit - Landing - Crew Egress

The STS-87 Space Shuttle Columbia mission begins with the introduction of the seven crew members. The seven crew members include: Commander Kevin R. Kregel, pilot Steven W. Lindsey, mission specialists: Winston E. Scott, Kalpana Chawla and Takao Doi and payload specialist Leonid K. Kadenyuk. The United States Microgravity Payload (USMP-4), Orbital Acceleration Research Experiment (OARE), the EVA Demonstration Flight Test 5 (EDFT-05), Shuttle Ozone Limb Sending Experiment (SOLSE), Loop Heat Pump (LHP), and Sodium Sulfur Battery Experiment (NaSBE) were all shown during this video presentation. The launch of the STS-87 from different Kennedy Space Flight Center (KSFC) areas and Pre-flight training at the Johnson Space Center is presented. The retrieve and recovery spot satellite are also shown. Also, the landing of the Space Shuttle Columbia is presented from different areas at Kennedy Space Flight Center.

Source record↗

Design and Testing of Non-Toxic RCS Thrusters for Second Generation Reusable Launch Vehicle

Under NASA sponsorship, Northrop Grumman Space Technology (NGST) designed, built and tested two non-toxic, reaction control engines, one using liquid oxygen (LOX) and liquid hydrogen (LH2) and the other using liquid oxygen and ethanol. This paper presents the design and testing of the LOX/LH2 thruster. The two key enabling technologies are the coaxial liquid-on-liquid pintle injector and the fuelcooling duct. The workhorse thruster was hotfire tested at the NASA Marshall Space Flight Center Test Stand 500 in March and April of 2002. All tests were performed at sea-level conditions. During the test program, 7 configurations were tested, including 2 combustion chambers, 3 LOX injector pintle tips, and 4 LHp injector settings. The operating conditions surveyed were 70 to 100% thrust levels, mixture ratios from 3.27 to 4.29, and LH2 duct cooling from 18.0 to 25.5% fuel flow. The copper heat sink chamber was used for 16 burns, each burn lasting from 0.4 to 10 seconds, totaling 51.4 seconds, followed by Haynes chamber testing ranging from 0.9 to 120 seconds, totaling 300.9 seconds. The performance of the engine reached 95% C* efficiency. The temperature on the Haynes chamber remained well below established material limits, with the exception of one localized hot spot. These results demonstrate that both the coaxial liquid-on-liquid pintle injector design and fuel duct concepts are viable for the intended application. The thruster headend design maintained cryogenic injection temperatures while firing, which validates the selected injector design approach for minimal heat soak-back. Also, off -nominal operation without adversely impacting the thermal response of the engine showed the robustness of the duct design, a key design feature for this application. By injecting fuel into the duct, the throat temperatures are manageable, yet the split of fuel through the cooling duct does not compromise the overall combstion efficiency, which indicates that, provided proper design refinement, such a concept could be applied to a high-performance version of the thruster.

Calvignac, Jacky↗

Effect of Variable Emittance Coatings on the Operation of a Miniature Loop Heat Pipe

Abstract. As the size of spacecraft shrink to accommodate small and more efficient instruments, smaller launch vehicles, and constellation missions, all subsystems must also be made smaller. Under NASA NFL4 03-OSS-02, Space Technology-8 (ST 8), NASA Goddard Space Flight Center and Jet Propulsion Laboratory jointly conducted a Concept Definition study to develop a miniature loop heat pipe (MLHP) thermal management system design suitable for future small spacecraft. The proposed MLHP thermal management system consists of a miniature loop heat pipe (LHP) and deployable radiators that are coated with variable emittance coatings (VECs). As part of the Phase A study and proof of the design concept, variable emittance coatings were integrated with a breadboard miniature loop heat pipe. The miniature loop heat pipe was supplied by the Jet Propulsion Laboratory (PL), while the variable emittance technology were supplied by Johns Hopkins University Applied Physics Laboratory and Sensortex, Inc. The entire system was tested under vacuum at various temperature extremes and power loads. This paper summarizes the results of this testing and shows the effect of the VEC on the operation of a miniature loop heat pipe.

Douglas, Donya M.↗

Miniature Loop Heat Pipe with Multiple Evaporators for Thermal Control of Small Spacecraft

This paper presents an advanced miniature heat transport system for thermal control of small spacecraft. The thermal system consists of a loop heat pipe (LHP) with multiple evaporators and multiple deployable radiators for heat transfer, and variable emittance coatings on the radiators for performance enhancement. Thermoelectric coolers are used to control the loop operating temperature. The thermal system combines the functions of variable conductance heat pipes, thermal switches, thermal diodes, and the state-of-the-art LHPs into a single integrated thermal system. It retains all the performance characteristics of state-of-the-art LHPs and offers additional advantages to enhance the functionality, performance, versatility, and reliability of the system. Steady state and transient analytical models have been developed, and scaling criteria have also been established. A breadboard unit has been built for functional testing in laboratory and thermal vacuum environments. Experimental results show excellent performance of the thermal system and correlate very well with theoretical predictions.

Ku, Jentung↗

A mini loop heat pipe suitable for Mars rovers

This paper describes the thermal design requirements, the thermal performance characteristics and the flight qualification program of a mini-LHP suitable for the Mars Rovers.

loop heat pipe Mars rover thermal control↗

Loop Heat Pipe Operation with Thermoelectric Converters and Coupling Blocks

This paper presents theoretical and experimental studies on using thermoelectric converters (TECs) and coupling blocks to control the operating temperature of a miniature loop heat pipes (MLHP). The MLHP has two parallel evaporators and two parallel condensers, and each evaporator has its own integral compensation chamber (CC). A TEC is attached to each CC, and connected to the evaporator via a copper thermal strap. The TEC can provide both heating and cooling to the CC, therefore extending the LHP operating temperature over a larger range of the evaporator heat load. A bi-polar power supply is used for the TEC operation. The bipolar power supply automatically changes the direction of the current to the TEC, depending on whether the CC requires heating or cooling, to maintain the CC temperature at the desired set point. The TEC can also enhance the startup success by maintaining a constant CC temperature during the start-up transient. Several aluminum coupling blocks are installed between the vapor line and liquid line. The coupling blocks serve as a heat exchanger which preheats the cold returning liquid so as to reduce the amount of liquid subcooling, and hence the power required to maintain the CC at the desired set point temperature. This paper focuses on the savings of the CC control heater power afforded by the TECs when compared to traditional electric heaters. Tests were conducted by varying the evaporator power, the condenser sink temperature, the CC set point temperature, the number of coupling blocks, and the thermal conductance of the thermal strap. Test results show that the TECs are able to control the CC temperature within k0.5K under all test conditions, and the required TEC heater power is only a fraction of the required electric heater power.

Ku, Jentung↗

Effects of Gravity on Start-up of a Miniature Loop Heat Pipe with Multiple Evaporators and Multiple Condensers

This paper describes an experimental study on the effect of gravity on the start-up of a miniature loop heat pipe (MLHP) with two evaporators and two condensers. Each evaporator has an outer diameter of 9 mm and has its own integral compensation chamber (CC). The MLHP was placed under five configurations where the relative elevation and tilt among the loop components were varied. The four well-known initial conditions between the evaporator and CC prior to the LHP start-up were created in this experimental study through combinations of: 1) the test configuration; 2) the method of preconditioning the loop prior to start-up, and 3) the heat load distribution among the evaporators. A total of 165 start-ups were conducted under the five test configurations. All of these start-ups were successful. However, the effect of gravity on start-up transients was clearly seen under otherwise the same heat load distribution and sink temperatures. An analytical model was used to simulate the MLHP transient behaviors, and the model predictions agreed very well with the experimental results.

Ku, Jentung↗

Analytical Approach in DeCoM

There are many papers on describing a LHP as an overall system, but few detail on the condenser section of a loop heat pipe. The DeCoM (Deepak Condenser Model) method utilizes user set initial parameters in-order to simulate a condenser by calculating the interactions between the fluid and the wall. Equations are derived for two sections of the condenser: a two-phase section and a subcooled (liquid) section. All Equations are based upon the conservation of energy theory, from which fluid temperature, and fluid quality values are solved. In order to solve for the heat transfer value, between fluid and the wall in two phase section, the Lockhart-Martinelli correlation method was implemented as a solution approach. For Liquid phase, the Reynolds number was used in-order to differentiate the flow state, from either turbulent or laminar, and Nusselt number was used to solve for the film coefficient. To represent these calculations for both sections a flow chart is presented in order to display the execution process of DeCoM. The benefit of DeCoM is that it is capable of performing preliminary analysis without requiring a license and without much of users knowledge on condensers.

Patel, Deepak↗

Introduction to Loop Heat Pipes

This is the presentation file for the short course Introduction to Loop Heat Pipes, to be conducted at the 2015 Thermal Fluids and Analysis Workshop, August 3-7, 2015, Silver Spring, Maryland. This course will discuss operating principles and performance characteristics of a loop heat pipe. Topics include: 1) pressure profiles in the loop; 2) loop operating temperature; 3) operating temperature control; 4) loop startup; 4) loop shutdown; 5) loop transient behaviors; 6) sizing of loop components and determination of fluid inventory; 7) analytical modeling; 8) examples of flight applications; and 9) recent LHP developments.

Heat Pipes↗

Instrument Thermal Management for Lunar Night Survival without Radioisotopes

This paper summarizes the technology development progress on two JPL projects focused on developing thermal designs/technologies that enable lunar instrument overnight survival without radioisotopes. Through an internal project known as ARTEMIS, JPL has developed lunar night survivable designs for magnetometer, seismometer, and IR spectrometer science payloads (SPs). These designs incorporate four hyper-isolative thermal management features under development on the NASA GCD-funded PALETTE project: (a) a dual enclosure system with high strength, low k tension cable (TC) supports and a variable conductance thermal link (VCTL) composed of a reverse-operation DTE thermal switch (ROD-TSW) in series with a miniaturized loop heat pipe (mini-LHP); (b) a parabolic reflector radiator (PRR) for low-to-mid latitude lunar sites; (c) ultra-low e* “spacerless” MLI, in which individual layers are hung from the TC supports; and (d) ultra-low G thermal isolators made with polymeric material or polymer/TC assemblies. Each instrument design incorporates solar panels, batteries, telecom, C&DH, and other features necessary for self-sufficient, extended-duration operation on the lunar surface. This paper will provide an overview of the ARTEMIS and PALETTE projects and provide a top-level description of the instrument thermal management approach.

Lin, Ying↗

Planetary and Lunar Environment Thermal Toolbox Elements (PALETTE) Project Year One Results

This paper summarizes the technology development progress made during year one of the three-year JPL PALETTE project, which is funded by the NASA STMD Game Changing Development (GCD) Program. The project goal is to ensure that a full “palette” of flight-ready (high TRL) thermal “toolbox” elements is available so that engineers can create passive, ultra-isolative thermal designs for science instruments on a variety of carriers in lunar/planetary extreme environments. PALETTE is structured to meet the need via four design/build/test tasks and four analysis/study tasks. This paper focuses on Tasks 1-4, the four design/build/test tasks. Task 1 involves the development of nested thermally-switched enclosures featuring a reverse-operation DTE thermal switch (ROD-TSW) in series with a propylene miniaturized loop heat pipe (mini-LHP). Task 2 involves the development of a parabolic reflector radiator (PRR) for low latitude lunar sites. Task 3 involves the development of a low effective emissivity (e*) multilayer insulation (MLI) known as “spacerless” MLI. Finally, Task 4 involves the development of low conductance (G) thermal isolators. Available test results for all four tasks will be summarized in the paper, as will the plans for the remainder of the PALETTE project.

Britton, Shawn R↗