Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOW PRESSURE CHAMBER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

101 records · Page 6

Characterization of Flex-Fuel Prechamber Enabled Mixing-Controlled Combustion With Gasoline/Ethanol Blends at High Load

This numerical study focuses on the characterization of prechamber-enabled mixing-controlled combustion (PC-MCC) at ~18 bar brake mean effective pressure (BMEP) and 2200 rpm with 10% by volume ethanol-gasoline blend (E10) and pure ethanol (E100). Computational fluid dynamic (CFD) simulations of a stock and prechamber retrofitted single-cylinder Caterpillar C9.3B are carried out using CONVERGE. Prechamber equivalence ratio at spark timing, prechamber spark timing advance, and main chamber injection strategy are assessed with respect to their impact on ignition assistance performance and emissions characteristics relative to a diesel baseline at the same boundary conditions. Simulation results indicate that PC-MCC is flex-fuel capable and operates well for both E10 and E100 at the operating conditions considered. The results demonstrate that the use of a pilot-main injection strategy enables spark timing in the prechamber to be advanced and thus reduces spark plug firing pressure while maintaining robust ignition assistance. Results also indicate that the rich prechamber operation is favored for improved ignition assistance capabilities. Furthermore, the findings of this work suggest that a heavy-duty vehicle using a PC-MCC engine can utilize any blend of gasoline and ethanol, up to including pure ethanol, with no major sacrifices in performance relative to the diesel engine.

33 ADVANCED PROPULSION SYSTEMS↗

Study of a linear surface wave plasma source for tin removal in an extreme ultraviolet source

Tin deposition mitigation employs hydrogen radicals and ions, formed in a hydrogen plasma, to interact with tin to form tin hydride (SnH 4 ) in the gaseous state, which is then pumped away. Surface wave plasma (SWP) technology developed at Illinois generates hydrogen radicals and ions, resulting in tin etch rates that are high enough to keep extreme ultraviolet (EUV) lithographic tools clean. An advantage of an SWP antenna is the ability to generate a high density of hydrogen radicals and hydrogen ions directly at the desired etching location. In situ etching of tin enables high availability EUV tools by maintaining high reflectivity of the multilayer mirror of the collector. Additionally, the SWP is characterized with low ion energies and low electron temperature, such that the multilayer mirror does not suffer any damage from sputtering or implantation of hydrogen ions during operation. Here, experiments elucidating the fundamental processes of tin removal are conducted by varying pressure, power, surface temperature, and gas flow rate in order to observe the etch rate behavior. Our results have shown that the presence of hydrogen ions increases etch rates because ion bombardment weakens Sn–Sn bonds, which, in turn, allows for a higher rate of chemical etching by the radicals. The ion bombardment reduces the number of radicals needed to etch a single tin atom to the range of 10 2 –10 3 . The linear SWP antenna yields plasma densities on the order of 10 17 to 10 18 m -3 and radical densities on the order of 10 18 to 10 19 m -3 , allowing for greater utilization of ion etch enhancement. Etch rates of up to 200 nm/min have been achieved. The surface temperature of the samples is an important factor in the etching process such that the decrease in the surface temperature increases the etch rates and decreases the hydrogen desorption rates. In addition, a kinetic etch model is developed to explain the behavior of etch rates as a function of surface temperature. Furthermore, results from experiments performed in an Illinois NXE:3100 chamber will be discussed.

42 ENGINEERING↗

Parameter dependencies of the separatrix density in low triangularity L-mode and H-mode JET-ILW plasmas

Abstract The midplane electron separatrix density, n e,sep , in JET-ILW L-mode and H-mode low triangularity deuterium fuelled plasmas exhibits a strong explicit dependence on the averaged outer divertor target electron temperature, n e,sep ∼ T e,ot −1/2 . This dependence is reproduced by analytic reversed two point model (rev-2PM), and arises from parallel pressure balance, as well as the ratio of the power and momentum volumetric loss factors, (1 − f cooling )/(1 − f mom-loss ). Quantifying the influence of the (1 − f cooling ) and (1 − f mom-loss ) loss factors on n e,sep has been enabled by measurement estimates of these quantities from L-mode density (fueling) ramps in the outer horizontal, VH(C), and vertical target, VV, divertor configurations. Rev-2PM n e,sep estimates from the extended H-mode and more limited L-mode datasets are recovered to within ±25% of the measurements, with a scaling factor applied to account for use of T e,ot , an averaged quantity, rather than flux tube resolved target values. Both the (1 − f cooling ) and (1 − f mom-loss ) trends and recovery of n e,sep using the rev-2PM formatting are reproduced in EDGE2D-EIRENE L-mode-like and H-mode-like density scan simulations. The general lack of a divertor configuration effect in the JET-ILW n e,sep trends can be attributed to a significant influence of main chamber recycling, which has been shown in the EDGE2D-EIRENE results to moderate n e,sep with respect to changes in divertor neutral leakage imposed by changes in the divertor configuration. The unified n e,sep vs T e,ot trends can, however, be broken if large modifications to the divertor geometry (e.g. complete removal of the outer divertor baffle structure) are introduced in the model. The more pronounced high-field side high density region formation in the VH(C) configuration with reduced clearance to the separatrix does not appear to have a significant influence on the outer midplane separatrix and pedestal parameters when mapped to T e,ot , although conditions at the inner midplane could not be assessed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new open‐path eddy covariance method for nitrous oxide and other trace gases that minimizes temperature corrections

Abstract Low‐power, open‐path gas sensors enable eddy covariance (EC) flux measurements in remote areas without line power. However, open‐path flux measurements are sensitive to fluctuations in air temperature, pressure, and humidity. Laser‐based, open‐path sensors with the needed sensitivity for trace gases like methane (CH 4 ) and nitrous oxide (N 2 O) are impacted by additional spectroscopic effects. Corrections for these effects, especially those related to temperature fluctuations, often exceed the flux of gases, leading to large uncertainties in the associated fluxes. For example, the density and spectroscopic corrections arising from temperature fluctuations can be one or two orders of magnitude greater than background N 2 O fluxes. Consequently, measuring background fluxes with laser‐based, open‐path sensors is extremely challenging, particularly for N 2 O and gases with similar high‐precision requirements. We demonstrate a new laser‐based, open‐path N 2 O sensor and a general approach applicable to other gases that minimizes temperature‐related corrections for EC flux measurements. The method identifies absorption lines with spectroscopic effects in the opposite direction of density effects from temperature and, thus, density and spectroscopic effects nearly cancel one another. The new open‐path N 2 O sensor was tested at a corn ( Zea mays L.) field in Southwestern Michigan, United States. The sensor had an optimal precision of 0.1 ppbv at 10 Hz and power consumption of 50 W. Field trials showed that temperature‐related corrections were 6% of density corrections, reducing EC random errors by 20‐fold compared to previously examined lines. Measured open‐path N 2 O EC fluxes showed excellent agreement with those made with static chambers ( m = 1.0 ± 0.3; r 2 = .96). More generally, we identified absorption lines for CO 2 and CH 4 flux measurements that can reduce the temperature‐related corrections by 10–100 times compared to existing open‐path sensors. The proposed method provides a new direction for future open‐path sensors, facilitating the expansion of accurate EC flux measurements.

47 OTHER INSTRUMENTATION↗

MOCVD Growth and Characterization of ZnSnN 2

Since the first few reports of its synthesis in 2011 and 20121-3, interest in ZnSnN 2 for diverse applications, including photovoltaics1,3,4, visible light photocatalysis5, and optoelectronics, has been growing. Novel nitride-based LED device designs promise high gains in efficiency at emission wavelengths into the green, amber and even red.6-8 Their realization requires the precise insertion of an ultrathin layer of ZnGeN 2 or ZnSnN 2 into the active region of an InGaAs-GaAs LED structure. While thin films of ZnSnN 2 have been synthesized by RF sputtering1,9 and by MBE 2,10,11, and thin films of ZnGeN 2 , ZnSiN 2 and their alloys by MOCVD, the synthesis of ZnSnN 2 thin films by MOCVD has not yet been reported. It is a challenging goal, given the narrow temperature window between efficient activation of ammonia and the thermal decomposition of ZnSnN 2 at near-atmospheric pressures. We report here the results of studies of ZnSnN 2 films grown on r- and c-plane sapphire substrates, GaN templates on sapphire, and In 0.15 Ga 0.85 N templates on GaN-on-sapphire, at temperatures from 500 °C to 560 °C, using tetramethyltin (TMSn), diethylzinc (DEZn), germane and ammonia. Chamber pressures were varied between 200 and 500 torr. In addition, the ratios of the cation precursors and the total cation-to-anion precursor ratios were varied. Single crystal growth, as evidenced by 2θ-ω x-ray diffraction scans, was achieved on all of these substrates. Wurtzitic (0002) ZnSnN 2 diffraction were observed at 2θ ~ 32.90 for the samples grown on c-sapphire, GaN (0001) and InGaN (0001) templates, and wurtzitic (11-20) peak at 2θ ~ 54.80 for the films grown on r-sapphire. Higher pressures and higher temperatures promoted better crystallinity and more continuous films, as revealed by scanning electron microscopy (SEM) images and 2θ-ω x-ray diffraction peak widths and intensities. Crystal quality was observed to be highly dependent on growth temperature. For example, in one series a 10 °C change in growth temperature resulting in a factor of 15 increase in diffraction peak intensity. SEM images show that films grown on the GaN templates had better uniformity in nucleation than those grown on sapphire. The presence of satellite peaks around the Bragg peak in the XRD 2θ-ω scan for a film grown on a GaN template, and the absence of satellite peaks for the films grown simultaneously on c- and r-sapphire, also indicate superior quality for the film grown on GaN. HAADF-STEM images of films grown on these templates showed smooth interfaces at the film-substrate boundary and show growth rates as high as 167 nm/h, considerably higher than reported previously for MBE growth.9,10 Electron diffraction patterns show single crystallinity. Rocking curves show FWHM as low as 0.100. RMS surfaces roughnesses, measured by atomic force microscopy, are of the order of 3 nm for 1µm x 1µm areas. Current work is focusing on optimizing growth on InGaN templates. These templates are promising for their relatively lower lattice mismatch with ZnSnN 2 . Their use is a next step toward producing LED device structures.

Jayatunga, Benthara Hewage Dinushi↗

First 3D vector tracking of helium recoils for fast neutron measurements at Super$\mathrm{KEKB}$

Here we present results from the first deployment of novel, high definition, compact gas Time Projection Chambers (TPCs) with pixel chip readout as part of the BEAST II beam background measurement project at SuperKEKB. The TPCs provide detailed 3D imaging of ionization from neutron-induced nuclear recoils in a helium and carbon dioxide target gas mixture at standard temperature and pressure. We present the TPC performance and the neutron backgrounds observed during the initial stage of collider commissioning. We find excellent electron background rejection, leading to background-free nuclear recoil measurements above 50 keV ee , despite the extreme high-background environment. We measure an angular resolution better than 20° for recoil tracks longer than 1.7 mm, corresponding to an average ionization energy of approximately 100 keV ee . We also obtain the full 3D vector direction of helium recoils by utilizing charge profile measurements along the recoil axis, with a correct head/tail assignment efficiency of approximately 80%. With this performance, we present comparisons between measured and simulated event rates, recoil energy spectra, and directional distributions originating from beam–gas and Touschek beam losses at SuperKEKB. We utilize head/tail recognition to distinguish neutron components traveling with positive radial velocity in the Belle II coordinate system from those traveling in the opposite direction. Finally, we present a novel method of discriminating beam–gas interactions from Touschek beam losses that can eliminate the need for dedicated accelerator runs for background measurements. This method is still statistics-limited. However, future studies should be able to verify this method, which in turn could lead to neutron background analysis runs symbiotic with normal Belle II operation. The capabilities demonstrated here also suggest that high definition recoil imaging in gas TPCs is applicable to low energy, low-background experiments, such as directional dark matter searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Verification of diesel spray ignition phenomenon in dual-fuel diesel-piloted premixed natural gas engine

Dual-fuel (DF) engines, in which premixed natural gas and air in an open-type combustion chamber is ignited by diesel-fuel pilot sprays, have been more popular for marine use than pre-chamber spark ignition (PCSI) engines because of their superior durability. However, control of ignition and combustion in DF engines is more difficult than in PCSI engines. In this context, here we focus on the ignition stability of n-heptane pilot-fuel jets injected into a compressed premixed charge of natural gas and air at low-load conditions. To aid understanding of the experimental data, chemical-kinetics simulations were carried out in a simplified engine-environment that provided insight into the chemical effects of methane (CH4) on pilot-fuel ignition. The simulations reveal that CH4 has an effect on both stages of n-heptane autoignition: the small, first-stage, cool-flame-type, low-temperature ignition (LTI) and the larger, second-stage, high-temperature ignition (HTI). As the ratio of pilot-fuel to CH4 entrained into the spray decreases, the initial oxidization of CH4 consumes the OH radicals produced by pilot-fuel decomposition during LTI, thereby inhibiting its progression to HTI. Using imaging diagnostics, the spatial and temporal progression of LTI and HTI in DF combustion are measured in a heavy-duty optical engine, and the imaging data are analyzed to understand the cause of severe fluctuations in ignition timing and combustion completeness at low-load conditions. Images of cool-flame and hydroxyl radical (OH*) chemiluminescence serve as indicators of LTI and HTI, respectively. The cycle-to-cycle and spatial variation in ignition extracted from the imaging data are used as key metrics of comparison. The imaging data indicate that the local concentration of the pilot-fuel and the richness of the surrounding natural-gas air mixture are important for LTI and HTI, but in different ways. In particular, higher injection pressures and shorter injection durations increase the mixing rate, leading to lower concentrations of pilot-fuel more quickly, which can inhibit HTI even as LTI remains relatively robust. Decreasing the injection pressure from 80 MPa to 40 MPa and increasing the injection duration from 500 µs to 760 µs maintained constant pilot-fuel mass, while promoting robust transition from LTI to HTI by effectively slowing the mixing rate. This allows enough residence time for the OH radicals, produced by the two-stage ignition chemistry of the pilot-fuel, to accelerate the transition from LTI to HTI before being consumed by CH4 oxidation. Thus from a practical perspective, for a premixed natural gas fuel–air equivalence-ratio, it is possible to improve the “stability” of the combustion process by solely manipulating the pilot-fuel injection parameters while maintaining constant mass of injected pilot-fuel. This allows for tailoring mixing trajectories to offset changes in fuel ignition chemistry, so as to promote a robust transition from LTI to HTI by changing the balance between the local concentration of the pilot-fuel and richness of the premixed natural gas and air. This could prove to be a valuable tool for combustion design to improve fuel efficiency or reduce noise or perhaps even reduce heat-transfer losses by locating early combustion away from in-cylinder walls.

42 ENGINEERING↗

Experimental Evaluation of Refrigerant Leak Characteristics for Different HVAC&R Equipment Types–Phase 2

The US Department of Energy (DOE) Building Technology Office (BTO) and the Air-conditioning, Heating & Refrigeration Technology Institute (AHRTI) collaborated to sponsor an experimental study of refrigerant leak characteristics at Oak Ridge National Laboratory (ORNL); AHRTI project 9012. The project has been conducted in two phases with objectives to conduct refrigerant leak tests on several heating, ventilating, air-conditioning and refrigeration (HVAC&R) systems under operating conditions representative of actual applications to document the pressure decay rate and the mass flow rate of leaked refrigerant as a function of time. Phase 1 of the project ran from late 2017 to late 2018 with refrigerant leaks imposed on five systems and the collection of data to meet the project objectives. Systems chosen covered three air-conditioning (AC) applications (packaged terminal AC or PTAC, 3-ton residential split system AC, and 5-ton packaged rooftop AC) and two refrigeration applications (split system unit cooler, and standalone display case). AHRTI members donated the test systems used for the project. The systems were tested at two different leak rates (catastrophic high rate simulating full line break and a lower flow rate), two leak locations (high-pressure side and low-pressure side), and two operating conditions (compressor ON or OFF). Phase 1 results were summarized in a project report by Baxter, et al. (2019)1. The leak rates imposed in Phase 1 led to much more rapid charge releases than the more typical much slower rates seen in practice that would take days, weeks, or months to empty a system of its entire charge. For Phase 2, the project sponsors asked that the “higher” leak rate target a total charge release time of about 4 min. This was intended to represent a “reasonable” worst case release scenario to match the refrigerant leak rate assumption used in the International Electrotechnical Commission (IEC) standard IEC 60335-2-40 (2016 version [IEC 2016]. A charge release time of about 20–40 min (leak release rate 5 to 10 times lower than higher rate) was targeted for the “lower” leak rate. This report provides a summary of the Phase 2 effort. Two additional HVAC systems were selected for testing in this phase. First was a multi-split air-conditioning (MS-AC) system with one outdoor section and two indoor units and a nameplate refrigerant charge of 1.75 kg (3.86 lb.) of R-410A. The MS-AC was tested in cooling only or AC operation. Second was a split system heat pump coupled to two different representative supply duct systems (HP-duct) and a nameplate charge of 3.83 kg (8.44 lb.) of R-410A. This system was tested in both space heating and AC modes. As in Phase 1 of the project, all tests were conducted using R-410A.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-rate heavy-ion tracking using MWPCs and PPACs with an Anti-Discharge Unit

This work reports on the development of two robust, heavy-ion beam tracking concepts operating at low pressure (< 15 Torr) for high rate applications (> 200 kHz). The first concept consists of a Multi-Wire Proportional Counter (MWPC) with a central anode consisting of 12 μm Au-plated Tungsten wires spaced 1 mm from each other. The anode grid is sandwiched between two segmented cathodes aligned orthogonally in the two dimensions for (x,y) particle localization. The second detector is a Parallel-Plate Avalanche Counter (PPAC) that uses the same readout geometry as the MWPC, but replaces the wire anode with a 150 nm silver layer deposited on both sides of a thin (< 1 mg/cm 2 ) polypropylene foil. Additionally, the bias circuitry for the PPAC anode central foil is equipped with an Anti-Discharge Unit (ADU) to prevent transitions from proportional operation to streamer formation, thereby avoiding damaging discharges. The localization capability of both detectors was tested with a low-rate alpha-particle source (241-Am). A position resolution of < 1 mm (FWHM) was achieved under stable, high-gas-gain (> 1000) operating conditions. Their performance in terms of detection efficiency as a function of the isotope charge (Z) was determined by irradiating the detectors with a cocktail beam (Z ≤ 15) with energy of ∼ 100 MeV/u. Full detection efficiency is maintained for all available fragments under optimal operational conditions (i.e., voltage bias). Full detection efficiency was achieved at rates above 200 kHz by irradiating the detectors with a 1 cm diameter 238 U beam at an energy of 143 MeV/u.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance Evaluation of AG-1 FC HEPA Filters and Medium in Nuclear Complex Facilities - 20434

High Efficiency Particulate Air (HEPA) filters are credited as the final barrier against the release of radioactive aerosol contamination in nearly every operating U. S. Department of Energy (DOE) and National Nuclear Security Agency (NNSA) nuclear facility. The Institute for Clean Energy Technology (ICET) at Mississippi State University maintains a research program that studies various aspects of these components of containment systems and seeks to answer key questions from across the industry. This programmatic overview will include results from recent and ongoing studies, including a study on filter design and performance envelope, degradation due to aging or fatigue, fire event impact on HEPA filters, and accelerated aging of medium and component parts. ICET has completed a study helping to define the threshold for combined elevated temperature and relative humidity resistance of separator style and separator-less style HEPA filters that are used in DOE complexes. The study provides experimental data that considers elevated temperature, elevated relative humidity (RH), and target differential pressure (dP) in an attempt to gain a better understanding or more comprehensive insight into the operating envelope of different configurations of ASME (American Society for Mechanical Engineers) AG-1 Section FC filters. Test variables including air temperature ranges of 48.88 deg. C, 54.44 deg. C, or 60 deg. C (120, 130, or 140 deg. F); air RH ranges including 60-70%, 80%, or 90+% with initial filter dP of either 497.68 Pa, 746.52 Pa, or 995.36 Pa (2 inches water column (in. w. c.), 3 in. w. c., or 4 in. w. c.) included for full bracketing of each set of conditions. A study examining the effects of aging and fatigue on nuclear grade HEPA filters and medium elucidates the physical properties of media along with testing of new and aged ASME AG-1 HEPA filters. In addition to performing autopsies of the tested, aged filters to help better understand the service life of their performance, newly designed accelerated aging chambers allow new medium to undergo accelerated aging and exposure treatments. Evaluation of degradation in physical properties and functionality requires a high population of aged filters of different ages, designs, manufacturers, and operational histories. The limited availability of this population and the impropriety of looking solely at formulations and components from past years requires experimental design that will provide foresight into future filter performance. This undertaking therefore involves not only properties analysis of aged medium from different operational histories, ages, designs, and manufacturers, but also prescience in analytical goals via accelerated aging studies of newly manufactured media. A more complete understanding of the mechanisms of degradation from past formulations as well as current and future formulations is possible. Accelerated Aging of newly manufactured media utilizes exposure treatments based on the Arrhenius equation to artificially age medium and therefore glimpse into the future. Evaluation of current media properties This testing allows for the comparison of performance and durability of new filters under upset or design basis conditions with aged filters that were in service under ambient conditions and other aged filters retained in storage. Susceptibility of HEPA filters to the effects of combustion byproducts, heat, and water is also being studied in an attempt to gain understanding on the prevention of filter failures during fire events in nuclear facilities. ICET seeks to determine the effect of filter performance due to smoke loading using characterized smoke from variable fuel compositions, geometries, and loads; the smoke capacity of various filters with different burning conditions, heat release rates and transport, as well as mass transport from the air stream will be studied in low flow containment systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multivariate environmental and trait-based controls of transpiration in the Central Amazon Rainforest

Tropical forest tree mortality is increasing due to more severe droughts, yet our understanding of how tree traits and life strategies are linked to drought stress has been limited by measurement scarcity. The BIONTE (BIOmass and NuTrient Experiment) near Manaus, Brazil hosts one of the world’s largest sap flow installations, with sensors in 90 canopy trees across a wood density gradient monitored since June 2022. The 2023 El Niño drought provided a unique opportunity to evaluate how water availability impacts tree transpiration. An interpretable machine learning framework was used to study the complex interactions between transpiration and multiple environmental variables such as soil water availability and vapor pressure deficit (VPD), and how these interactions vary with wood density and individual trees. We found varying responses of transpiration from different trees during the El Niño drought. Transpiration generally increased with temperature, with stronger effects in wetter areas and in trees with low to medium wood density. However, this response was modulated by stomatal sensitivity to VPD, which constrained transpiration under high atmospheric demand, particularly in intermediate-moisture area. The inflection in transpiration rate at high temperatures (>32°C) underscores the role of stomatal and hydraulic regulation in limiting water loss and protecting trees from excessive evaporative demand. Analysis of soil water contribution to transpiration revealed unimodal patterns in wetter area, with peak contributions near 0.45 cm 3 cm -3 of surface soil water and declining or flat responses beyond that threshold, suggesting a shift from water- to energy-limited transpiration. In contrast, drier areas exhibited limited transpiration sensitivity to soil water conditions and minimal trait-based variation in VPD responses, indicating supply-limited conditions. Despite higher wood density trees being generally more resilient, this study shows diverse tree drought resilience, prompting further investigation into the specific traits and dynamics between environmental variables in regulating transpiration and other physiological processes in trees.

Drought↗