Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser-induced plasma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

2D-imaging of absolute OH and H 2 O 2 profiles in a He–H 2 O nanosecond pulsed dielectric barrier discharge by photo-fragmentation laser-induced fluorescence

We report pulsed dielectric barrier discharges (DBD) in He–H 2 O and He–H 2 O–O 2 mixtures are studied in near atmospheric conditions using temporally and spatially resolved quantitative 2D imaging of the hydroxyl radical (OH) and hydrogen peroxide (H 2 O 2 ). The primary goal was to detect and quantify the production of these strongly oxidative species in water-laden helium discharges in a DBD jet configuration, which is of interest for biomedical applications such as disinfection of surfaces and treatment of biological samples. Hydroxyl profiles are obtained by laser-induced fluorescence (LIF) measurements using 282 nm laser excitation. Hydrogen peroxide profiles are measured by photo-fragmentation LIF (PF-LIF), which involves photo-dissociating H 2 O 2 into OH with a 212.8 nm laser sheet and detecting the OH fragments by LIF. The H 2 O 2 profiles are calibrated by measuring PF-LIF profiles in a reference mixture of He seeded with a known amount of H 2 O 2 . OH profiles are calibrated by measuring OH-radical decay times and comparing these with predictions from a chemical kinetics model. Two different burst discharge modes with five and ten pulses per burst are studied, both with a burst repetition rate of 50 Hz. In both cases, dynamics of OH and H 2 O 2 distributions in the afterglow of the discharge are investigated. Gas temperatures determined from the OH-LIF spectra indicate that gas heating due to the plasma is insignificant. The addition of 5% O 2 in the He admixture decreases the OH densities and increases the H 2 O 2 densities. The increased coupled energy in the ten-pulse discharge increases OH and H 2 O 2 mole fractions, except for the H 2 O 2 in the He–H 2 O–O 2 mixture which is relatively insensitive to the additional pulses.

hydrogen peroxide↗

Simultaneous measurements of kinetic and scalar energy spectrum time evolution in the Richtmyer–Meshkov instability upon reshock

The Richtmyer–Meshkov instability (Richtmyer, Commun. Pure Appl. Maths , vol. 13, issue 2, 1960, pp. 297–319; Meshkov, Fluid Dyn. , vol. 4, issue 5, 1972, pp. 101–104) of a twice-shocked gas interface is studied using both high spatial resolution single-shot (SS) and lower spatial resolution, time-resolved, high-speed (HS) simultaneous planar laser-induced fluorescence and particle image velocimetry in the Wisconsin Shock Tube Laboratory's vertical shock tube. The initial condition (IC) is a shear layer with broadband diffuse perturbations at the interface between a helium–acetone mixture and argon. This IC is accelerated by a shock of nominal strength Mach number $M = 1.75$ , and then accelerated again by the transmitted shock that reflects off the end wall of the tube. An ensemble of experiments is analysed after reshock while the interface mixing width grows linearly with time. The kinetic and scalar energy spectra and the terms of their evolution equation are calculated and compared between SS and HS experiments. The inertial range scaling of the scalar power spectrum is found to follow Gibson's relation (Gibson, Phys. Fluids , vol. 11, issue 11, 1968, pp. 2316–2327) as a function of Schmidt number when the effective turbulent Schmidt number is used in place of the material Schmidt number that controls equilibrium scaling. Further, the spatially integrated scalar flux follows similar behaviour observed for the kinetic energy in large eddy simulation studies by Zeng et al. ( Phys. Fluids , vol. 30, issue 6, 2018, 064106) while the spatially varying scalar flux exhibits back scatter along the centre of the mixing layer and forward energy transfer in the spike and bubble regions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a Molten Salt Flow Cell for Combined Absorbance and Laser-Induced Breakdown Spectroscopy for Online Measurements

A novel flow cell allowing for multiple optical spectroscopy measurements on flowing molten salts was designed, and demonstrative calibrations of impurities in aqueous samples were performed. Online compositional measurements of molten salts are of high interest to monitor the state of relevant solar and nuclear systems. Here, the Spectroscopic Configuration for Optical Real-Time Characterization of High-Temperature (SCORCH) fluids cell was designed to meet this need by providing optical access to a high-temperature molten salt sample stream without physical contact between the sample and window materials. Laser-induced breakdown spectroscopy (LIBS) was utilized to quantify Li, Cr, Fe, Ni, Sr, and Pr at concentrations ranging nominally from 0 to 315 mmol L −1 . Laser power, frequency, and plasma position were optimized to mitigate challenges associated with sample splashing. Univariate calibration models were built with R 2 > 0.98, percent root mean square error of cross-validation (%RMSECV) as low as 2.7%, and limits of quantification (LOQs) down to 4.1 mmol L −1 . Simultaneously, absorbance calibrations were developed for the applicable analytes (Cr, Ni, and Pr) using Beer’s law with a pathlength of 4.41 ± 0.10 mm. These models provide excellent quantification performance with R 2 > 0.999, %RMSECV as low as 0.6%, and LODs down to 0.08 mmol L −1 . Although these calibrations were performed for each spectroscopic technique separately, the two methods may be combined in the future through multivariate modeling and sensor fusion to provide more robust models with the benefits of both techniques (e.g., absorbance: oxidation state concentrations, LIBS: elemental concentration). Additionally, optimized spectrometers may be deployed to enhance sensitivity.

absorbance spectroscopy↗

Chemistry imaging and distribution analysis of rare earth elements in coal using LIBS and LA-ICP-MS instruments

Currently, demand for rare earth elements (REEs) increased significantly. Coal is actively evaluated as potential economic sources for extraction of REEs. Here, in this work, laser-induced breakdown spectroscopy (LIBS) was evaluated for rapid estimation of REEs content and their distribution in the natural coal samples. The results were compared with similar laser ablation–inductively coupled plasma–mass spectrometry (LA-ICP-MS) measurements. Thirteen coal samples (nine standard samples and five natural samples) were used in this study. Powder samples were pressed into pellets while coal chunks were directly ablated for data recording. Pellets of the powder standard samples were used to optimize the data acquisition system and then data recorded with this optimized system was used to identify the proper data acquisition and analysis models. After establishing the proper data acquisition system and analysis model using the standard samples, natural coal samples in powder form and their chunks were utilized to record LIBS and LA-ICP-MS spectra. Multivariate calibration models were developed using four of the natural samples, which were evaluated by predicting the REE content in the fifth sample. Principal component analysis was performed on the LIBS data obtained from the natural samples and it classified all the samples with high accuracy. Two-dimensional (2D) elemental mapping on coal chunk samples was also performed using both LIBS and LA-ICP-MS to study the distribution of REEs in the samples. The resulting elemental images and their correlations can be used to infer mineral distributions.

01 COAL, LIGNITE, AND PEAT↗

Advancing Elemental and Isotopic Analysis of Uranium Mineral Inclusions: Rapid Screening via Laser-Induced Breakdown Spectroscopy and High-Resolution Laser Ablation-ICP-MS Mapping

The work presented herein employs two laser-based analytical techniques (laser-induced breakdown spectroscopy (LIBS) and laser ablation – inductively coupled plasma – mass spectrometry (LA-ICP-MS)) to spatially determine the elemental and isotopic composition of uranium bearing minerals. Uniquely, this work leverages the high-speed applicability of LIBS to “screen” the sample(s) for their elemental constituents. After determining the location of the uranium inclusions (via LIBS), high-resolution LA-ICP-MS was employed to further characterize the inclusions. The high-resolution (sub-µm) capabilities of LA-ICP-MS were able to extract important information from the uranium minerals including discerning its chemical form (e.g., finchite from carnotite, Sr- and K-bearing uranyl vanadates, respectively) as well as their 235 U/ 238 U isotopic composition. This approach, LIBS followed by LA-ICP-MS, significantly reduces the analysis time (~95 %) in comparison to employing a LA-ICP-MS only approach. Furthermore, this work presented a novel approach to analyzing inclusions via a particle/inclusion analysis tool which is commercially available within the iolite 4 software. This tool allowed for a more accurate characterization of the isotopic distribution of the inclusions, as well as allowing for rapid sizing of the inclusions. Finally, this analytical approach could readily be applied to other sample types in which the target species (e.g., µm-sized inclusions) are embedded in complex matrices (e.g., cm-sized samples).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Innovative laser-based methods for monitoring fuel retention in ITER

This paper addresses the challenge of tritium inventory management in ITER and future fusion reactors, highlighting the importance of accurate tritium measurement and its spatial distribution within the vacuum vessel. Given ITER’s operational constraints, especially the limit on tritium retention, precise measurement is essential for both safety and regulatory compliance. To tackle these questions, the paper presents the T-monitor diagnostic system developed by Forschungszentrum Jülich, which uses Laser-Induced Desorption (LID) in combination with Diagnostic Residual Gas Analysis (DRGA) to measure hydrogen isotope concentrations on the surface of divertor tiles. The system integrates a high-power laser, advanced optical components, and a Fast Scanning Mirror Unit (FSMU) for accurate laser spot positioning with rapid response. Designed to measure in situ tritium retention, the diagnostic provides high-resolution spatial mapping, vital for evaluating detritiation strategies. The laser heating process increases the divertor surface temperature to 1600 K within the laser spot, promoting hydrogen isotope desorption. Accurate measurements require the precise control of laser parameters, including pulse duration and spot size, with a target relative accuracy of 20%. The optical design includes both in-vessel and ex-vessel components, such as durable high-reflectivity mirrors made of gold and copper, selected not only for their infrared performance but also for their transmission of visible wavelengths for observation purposes. To protect optical components from contamination, a pneumatic shutter is used.

Hydrogen isotopes↗

Laser-driven ionization mechanisms of aluminum for single particle aerosol mass spectrometry

Single particle aerosol mass spectrometry (SPAMS), an analytical technique for measuring the size and composition of individual micron-scale particles, is capable of analyzing atmospheric pollutants and bioaerosols much more efficiently and with more detail than conventional methods which require the collection of particles onto filters for analysis in the laboratory. Despite SPAMS’ demonstrated capabilities, the primary mechanisms of ionization are not fully understood, which creates challenges in optimizing and interpreting SPAMS signals. In this paper, we present a well-stirred reactor model for the reactions involved with the laser-induced vaporization and ionization of an individual particle. The SPAMS conditions modeled in this paper include a 248 nm laser which is pulsed for 8 ns to vaporize and ionize each particle in vacuum. The ionization of 1 μm, spherical Al particles was studied by approximating them with a 0-dimensional plasma chemistry model. The primary mechanism of absorption of the 248 nm photons was pressure-broadened direct photoexcitation to Al(y 2 D). Atoms in this highly excited state then undergo superelastic collisions with electrons, heating the electrons and populating the lower energy excited states. We found that the primary ionization mechanism is electron impact ionization of various excited state Al atoms, especially Al(y 2 D). Because the gas expands rapidly into vacuum, its temperature decreases rapidly. The rate of three-body recombination (e - + e - + Al + → Al + e - ) increases at low temperature, and most of the electrons and ions produced recombine within several μs of the laser pulse. The importance of the direct photoexcitation indicates that the relative peak heights of different elements in SPAMS mass spectra may be sensitive to the available photoexcitation transitions. We also discuss the effects of laser intensity, particle diameter, and expansion dynamics.

47 OTHER INSTRUMENTATION↗

Imaging solvated oxygen atoms with a femtosecond laser

As a powerful oxidant, atomic oxygen (O) holds considerable promise for a variety of biomedical and industrial applications. However, the inability to quantify solvated oxygen atoms has prevented the determination of the fundamental parameters governing its behaviour in relevant aqueous environments. Here, we directly image ground-state oxygen atoms in water using femtosecond two-photon absorption laser-induced fluorescence. Measurements show that oxygen atoms persist for tens of microseconds in water, penetrating hundreds of micrometres into the liquid. This observed longevity has significant implications, suggesting a need to re-evaluate existing models of solvated atomic oxygen reactivity and transport. Beyond atomic oxygen, this technique is broadly applicable to other solvated atomic species of interest, including nitrogen (N) and hydrogen (H). This work establishes that radical atomic species can be quantified in liquid with ultrafast laser spectroscopy, providing the basis for the determination of key properties including reaction rates, chemical lifetimes, and Henry’s law constants.

Fluorescence spectroscopy↗

Elemental analysis of air-sensitive frozen molten salt samples using an inert transfer chamber for LIBS/LA-ICP-TOF-MS analysis

A novel inert sample transfer system was developed and employed to enable, for the first time, the analysis of air-sensitive salt samples in a two-volume ablation cell using simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation (LA)-inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) analysis. Molten salts are of growing interest as a medium for advanced nuclear reactors and nuclear fuel reprocessing technologies continue to be developed around their use. However, compositional analysis of molten salt samples can be challenging because of their air-sensitive nature and varying solubilities leading to inaccurate measurements when digested. LA-based analysis provides an alternate method to digestion and can provide rapid elemental information with little sample preparation. In this study, LIBS and LA-ICP-TOF-MS were used to analyze the Ce content in frozen salt samples taken from a series of electrochemical experiments. Calibrations were built for each technique, and the resulting limits of detection for Ce were estimated to be 107 and 58 µg g −1 for LIBS and LA-ICP-TOF-MS, respectively. Test samples from the electrochemical experiments were analyzed using these calibrations. The results matched bulk digestion-based ICP-optical emission spectroscopy values, and daily trends in Ce concentration changes were identified. Additionally, the LIBS and LA-ICP-TOF-MS analysis was demonstrated for identifying microgram per gram levels of components and detecting trace contaminants. The impurities detected by LIBS included Al, Mg, Ca, and Na. The impurities detected by LA-ICP-TOF-MS included W, Ag, Al, Fe, Ni, Mo, Nd, Sm, Th, and U.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

Effect of nuclear charge on laser-induced fusion enhancement in advanced fusion fuels

Here, based on the preliminary work done in a previous paper [Phys. Rev. C 105, 054001 (2022)], we investigate the effects of laser-induced fusion rate enhancements of different fusion fuels. In the aforementioned work, which considered $_{1}^{2}$H-$_{1}^{3}$H (D-T) and DHe 3 fusion, it was observed that a larger product of charge numbers of the fusion reactants leads to an increased laser-induced enhancement to the fusion cross section for static external electric fields. We investigate whether this trend persists for DT, DHe 3 , and pB 11 fusion for dynamical electric fields, using the semiclassical approaches of the Wentzel-Kramers-Brillouin method and the imaginary-time method, as well as the Kramers- Henneberger method, and the Volkoff-state approximation. We find that the fusion cross section of pB 11 indeed exhibits the largest relative enhancement for all laser parameters considered and may even surpass the cross section of DT and DHe 3 fusion.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Exploration of a Combined LIBS and LA-ICP-MS Approach for Apatite Characterisation

A combined laser‐induced breakdown spectroscopy (LIBS) and laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) method is demonstrated for comprehensive apatite analysis. These measurements provide elemental imaging that can be used as a screening technique for chemical selection of grains for subsequent analysis (e.g., U‐Pb geochronology) or can be used to understand elemental distributions within a single grain that would have direct textural‐chemical implications (e.g., zoning patterns). Adding LIBS as a simultaneous measurement, to LA‐ICP‐MS U‐Pb geochronology, allowed for the direct determination of F (H and O show promise for future applications) in addition to major and trace elements of interest. Here, the quantitative measurements were validated against a series of apatites with known values and used to characterise a wide range of samples. Fluorine detection limits were determined to be as low as 70 μg g ‐1 F (broadband CMOS detector) and 4.2 μg g ‐1 F (ICCD detector). U‐Pb age dating was simultaneously collected by LA‐ICP‐MS with the quantitative elemental data from LIBS, providing a comprehensive method for geochronology.

Apatite↗

Shock physics and shadowgraphic measurements of laser-produced cerium plasmas

Shadowgraphic measurements are combined with theory on gas-dynamics to investigate the shock physics associated with nanosecond laser ablation of cerium metal targets. Time-resolved shadowgraphic imaging is performed to measure the propagation and attenuation of the laser-induced shockwave through air and argon atmospheres at various background pressures, where stronger shockwaves characterized by higher propagation velocities are observed for higher ablation laser irradiances and lower pressures. The Rankine-Hugoniot relations are also employed to estimate the pressure, temperature, density, and flow velocity of the shock-heated gas located immediately behind the shock front, predicting larger pressure ratios and higher temperatures for stronger laser-induced shockwaves.

42 ENGINEERING↗

Excitation of optically trapped single particles using femtosecond pulses

Excitation from optically trapped particles is examined through laser-induced breakdown spectroscopy following interactions with mJ-level fs pulses. Optical emissions from sub-ng ablation of precisely positioned cupric oxide microparticles are used as a method to spatially resolve laser–particle interactions resulting in excitation. External focusing lenses are often used to change the dynamics of nonlinear self-focusing of fs pulses to form laser filaments or, alternatively, to form very intense air plasmas. Given the significant implications external focusing has on laser propagation and plasma conditions, single-particle emissions are studied with focusing lenses ranging from 50 to 300 mm. It is shown that, while single particles are less excited at longer focal lengths due to limited energy transfer through laser–particle interactions, the cooler plasma results in a lower thermal background to reveal resolved single-shot emission peaks. Furthermore, by developing an understanding in the fundamental interaction that occurs between single particles and fs pulses and filaments, practical improvements can be made for atmospheric remote sensing of low-concentration aerosols.

42 ENGINEERING↗

Establishing Isotopic Measurement Capabilities using Laser-Induced Breakdown Spectroscopy for the Molten Salt Reactor Campaign

Proof-of-principle H isotope ratios of aqueous aerosol systems and liquid droplets on filter paper have been measured using laser-induced breakdown spectroscopy (LIBS) with root mean square error of prediction values down to 1.9%. Molten salt reactors (MSRs) will consist of a complex chemical and radiological system consistently producing new fission products as the reactor operates. Some of these fission products and/or their daughter species will leave the salt in the reactor off-gas. Monitoring the composition of the off-gas, as well as the salt itself, is important for monitoring reactor performance, including burnup, corrosion, and the concentration of impurities. Tritium is of concern for MSRs because it will be produced from the irradiation of key salt constituents, including Li and Be. LIBS offers an avenue for in situ salt and off-gas monitoring by firing a laser onto or into the sample stream to generate a plasma. The plasma light can be monitored to measure an elemental fingerprint of the sample. Extending this analysis to include isotopic ratios offers a critical expansion of the in situ monitoring capabilities being developed. This study demonstrates the expansion of Oak Ridge National Laboratory’s LIBS capabilities to monitor isotopes and shows how simple calibrations may provide rapid semiquantitative models.

07 ISOTOPE AND RADIATION SOURCES↗

ElementLIBS User's Guide: An operational aid for use and development

Laser-Induced Breakdown Spectroscopy or LIBS is a rapid, in-situ analytical technique where a laser of known energy is pulsed at the surface of an analyte. The laser pulse rapidly heats a localized area to many thousand degrees Kelvin, ablating part of the analyte and turning it into a plasma. As the plasma cools, excited atoms return to a ground state with known emission energies. This emitted energy is captured by various spectrometers and provides a spectrum of the emitted energies and intensities. This spectrum can be analyzed to provide the elemental composition of a sample by using known emission lines and relative abundance. ElementLIBS was developed for the SciAps hand-held LIBS model Z300 but will work with any model that provides a LIBS spectrum of similar resolution. The Z300 has an integrated resolution of 1/30 nm with a range of approximately 180nm – 960nm, providing an output spectrum of 23431 pixels across three spectrometers. These criteria are only provided as a reference, as the software was designed to work with any size spectrum, provided the input file is of the correct format and the models were developed using the same framework. If spectra of varying dimensions are used, the software will fail without warning and unusual events could occur.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser-Induced Spectrochemical Assay for Uranium Enrichment (LISA-UE)

Uranium hexafluoride (UF6) is the uranium compound typically involved in uranium enrichment process. As the first line of defense against nuclear proliferation, accurate determinations of the uranium enrichment ratio in UF6 are critical for materials verification, accounting and safeguards. Shipping gaseous UF6 samples off-site for analysis with mass spectrometry is cumbersome and costly, and results are not available for some time (months). In-field UF6 enrichment assay has the potential to substantially reduce the time, logistics and expense of sample handling. At present, COMPUCEA is the only accepted method for UF6 enrichment assay in the field. Laser-Induced Spectrochemical Assay for Uranium Enrichment (LISA-UE) is an all-optical (based on laser induced plasma emission) analytical technique intended for fieldable, accurate, precise and rapid UF6 enrichment assay. In its operation, laser induced plasma is created directly in the gaseous UF6 sample. Because different U isotopes emit at slightly different wavelengths, the isotopic information of the UF6 sample is inherently encoded in the atomic emission from the plasma. Isotopic emissions from 235U and 238U are measured simultaneously, which eliminate correlated noise from the laser induced plasma. Isotopic information of the UF6 sample can be extracted from the acquired spectrum with theoretical multi-variable non-linear spectral fitting. To date, advances made by the LISA-UE research team include optimization of the spectral window for direct gaseous UF6 enrichment assay with laser induced plasma, development of data reduction algorithms, and demonstrations of the LISA-UE technique with gaseous UF6 samples. In this presentation, the technical aspect of LISA-UE will be overviewed, the data reduction algorithm will be described, and performance of the technique will be discussed.

Chan, George↗

Towards the development of resonantly enhanced laser-based diagnostics for molten salt reactor safeguards

The adoption of Generation IV molten salt reactors (MSRs) depends on the ability to implement compatible monitoring instrumentation to ensure adherence to nuclear safeguards. This task is nontrivial due to the high temperature, reactive, and chemically complex fuel and coolant components contained within these systems. Optical spectroscopy techniques such as laser-induced fluorescence (LIF) and laser-induced breakdown spectroscopy (LIBS) are candidates for monitoring instrumentation. They offer many advantages for continuous monitoring, including the ability to operate at a standoff and compatibility with liquid-phase analytes. We discuss the use of LIF for the detection of Nd, a common fission fragment, within a liquid matrix. Results show that for NdCl3 dissolved in water, the Nd I 492.45 nm resonant transition is detectable without the need to induce a plasma and that the fluorescence emission can be separated in the time domain from the laser scatter signal. Additionally, we present a setup and preliminary results for measurements of solid Nd and U using resonant LIBS. The results demonstrate element-selective measurement capabilities and provide the foundational data necessary to continue the development of laser-based MSR diagnostics. This work also helps address gaps in the literature regarding energy level assignments of Nd.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗