Search NASA⌕ Search

SEARCH · Search NASA

Results for “Latex”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A microprocessor-based one dimensional optical data processor for spatial frequency analysis

A high degree of accuracy was obtained in measuring the spatial frequency spectrum of known samples using an optical data processor based on a microprocessor, which reliably collected intensity versus angle data. Stray light control, system alignment, and angle measurement problems were addressed and solved. The capabilities of the instrument were extended by the addition of appropriate optics to allow the use of different wavelengths of laser radiation and by increasing the travel limits of the rotating arm to + or - 160 degrees. The acquisition, storage, and plotting of data by the computer permits the researcher a free hand in data manipulation such as subtracting background scattering from a diffraction pattern. Tests conducted to verify the operation of the processor using a 25 mm diameter pinhole, a 39.37 line pairs per mm series of multiple slits, and a microscope slide coated with 1.091 mm diameter polystyrene latex spheres are described.

Collier, R. L.↗

Studies with sample conductivity, insertion rates, and particle deflection in a continuous flow electrophoresis system

The continuous flow electrophoresis system makes electrophoresis possible in a free-flowing film of aqueous electrolyte medium. The sample continuously enters the electrolyte at the top of the chamber and is subjected to the action of a lateral dc field. This divides the sample into fractions since each component has a distinctive electrophoretic mobility. Tests were made using monodisperse polystyrene latex microspheres to determine optimum sample conductivity, insertion rates and optimum electric field applications as baseline data for future STS flight experiments. Optimum sample flow rates for the selected samples were determined to be approximately 26 micro-liters/min. Experiments with samples in deionized water yielded best results and voltages in the 20 V/cm to 30 V/cm range were optimum. Deflections of formaldehyde fixed turkey and bovine erythrocytes were determined using the continuous flow electrophoresis system. The effects of particle interactions on sample resolution and migration in the chamber was also evaluated.

Williams, G., Jr.↗

STS-6 sixth Space Shuttle mission. First flight of the Challenger

A prelaunch summary of the sixth Space Shuttle mission is provided. The Challenger orbiter; launching; uprated engines; lighter weight boosters; lightweight tank; external tank reduction; landing; the tracking and data relay satellite system (TDRSS), TDRS-1 deployment; the inertial upper stage (IUS), the spacewalk;electrophoresis, monodisperse latex reactor, night time/day time optical survey of lightning, and getaway special experiments are described.

Source record↗

Convective and interfacial instabilities during solidification of succinonitrile containing ethanol

Even though slow convective flow is difficult to detect in solidifying metals, it can readily be observed in transparent materials by observing the motion of small neutrally buoyant particles. Succinonitrile, which solidifies with an unfaceted solid/liquid interface and has well characterized physical properties, is considered an excellent material for such studies. For studies of solute-induced convection, ethanol is a useful addition to succinonitrile since it has a lower density and a somewhat similar molecular structure. Samples of high purity and ethanol-doped succinonitrile are unidirectionally solidified in a vertical temperature gradient. Latex mimcrospheres 2 microns in diameter are suspended in the liquid to reveal the convective flow. Convective and morphological stability is observed as a function of solute concentration and growth velocity. These measurements are compared with theoretical calculations that predict the transition from stability to instability as a function of solidification conditions. The predicted transitions occur at low concentrations and solidification velocities; for this reason, extreme care must be taken in order to eliminate the effects of impurities or thermally induced convection.

Schaefer, R. J.↗

National Space Transportation Systems Program mission report

The 515-41B National Space Transportation Systems Program Mission Report contains a summary of the major activities and accomplishments of the sixth operational Shuttle flight and fourth flight of the OV-099 vehicle, Challenger. Since this flight was the first to land at Kennedy Space Center, the vehicle was towed directly to the OPF (Orbiter Processing Facility) where preparations for flight STS-41C, scheduled for early April 1984, began immediately. The significant problems that occurred during STS-41B are summarized and a problem tracking list that is a complete list of all problems that occurred during the flight is given. None of the problems will affect the STS 41C flight. The major objectives of flight STS-41B were to successfully deploy the Westar satellite and the Indonesian Communications Satellite-B2 (PALAPA-B2); to evaluate the MMU (Manned Maneuvering Unit) support for EVA (Extravehicular Activities); to exercise the MFR (Manipulator Foot Restraint); to demonstrate a closed loop rendezvous; and to operate the M.R (Monodisperse Latex Reactor), the ACES (Acoustic Containerless Experiment System) and the IEF (Isoelectric Focusing) in cabin experiments; and to obtain photographs with the Cinema 360 Cameras.

Collins, M. A., Jr.↗

Recommendations and calculations concerning physical characteristics of the EEVT apparatus

Several issues arose during the course of preparing for the flight of EEVT on STS-3. Documents concerning the issues are presented in the following order: (1) the possibility of mixing latex spheres with kidney cells as standard electrokinetic markers; (2) tube breakage and the potential for the development of leaks and bubbles; (3) effects of the shape of the sample gate on the electric field and the outward migration of cells; (4) suggestions for reducing electroosmosis by decreasing the diameter of the sample; and (5) predictions of the effects of modified sample dimensions on electroosmotic band spreading.

Source record↗

Reflectivity of the atmosphere-inhomogeneous surfaces system Laboratory simulation

Theoretical two- and three-dimensional solutions of the radiative transfer equation have been applied to the earth-atmosphere system. Such solutions have not been verified experimentally. A laboratory experiment simulates such a system to test the theory. The atmosphere was simulated by latex spheres suspended in water and the ground by a nonuniform surface, half white and half black. A stable radiation source provided uniform illumination over the hydrosol. The upward radiance along a line orthogonal to the boundary of the two-halves field was recorded for different amounts of the hydrosol. The simulation is a well-defined radiative transfer experiment to test radiative transfer models involving nonuniform surfaces. Good agreement is obtained between the measured and theoretical results.

Mekler, Y.↗

Electrophoresis technology

A new high resolution apparatus designed for space was built as a laboratory prototype. Using a moving wall with a low zeta potential coating, the major sources of flow distortion for an electrophoretic sample stream are removed. Highly resolved fractions, however, will only be produced in space because of the sensitivity of this chamber to buoyancy-induced convection in the laboratory. The second and third flights of the McDonnell Douglas Astronautics Corporation continuous flow electrophoresis system carried samples developed at MSFC intended to evaluate the broad capabilities of free flow electrophoresis in a reduced gravity environment. Biological model materials, hemoglobin and polystyrene latex microspheres, were selected because of their past use as electrophoresis standards and as visible markers for fluid flow due to electroosmosis, spacecraft acceleration or other factors. The dependence of the separation resolution on the properties of the sample and its suspension solution was assessed.

Snyder, R. S.↗

Multiple scattering measurements in laboratory and foggy atmosphere

Multiple scattering affects propagation of light beams in turbid media. Backscattering or forward scattering based measurements of atmospheric parameters are influenced by this effect. Although largely studied theoretically, the effect needs measurements in control of situations due to the large variety of situations of practical importance. The results of laboratory measurements pertaining to the transmission of a collimated light beam (Helium-Neon souce, 10 mW) through suspensions of latex spheres in water are presented and a comparison was made with the predictions of calculation in a foggy atmosphere will also be presented.

Bruscaglioni, P.↗

Processing materials in space - The history and the future

The development of materials processing in space, and some of the Soyuz, Apollo, Skylab, and Shuttle orbital materials experiments are reviewed. Consideration is given to protein crystal growth, electrophoresis, low-gravity isoelectric focusing, phase partitioning, a monodisperse latex reactor, semiconductor crystal growth, solution crystal growth, the triglycine sulfate experiment, vapor crystal growth experiments, the mercuric iodide experiment, electronic and electrooptical materials, organic thin films and crystalline solids, deep undercooling of metals and alloys, magnetic materials, immiscible materials, metal solidification research, reluctant glass-forming materials, and containerless glass formation. The space processing apparatuses and ground facilities, for materials processing are described. Future facilities for commercial research, development, and manufacturing in space are proposed.

Chassay, Roger↗

Control of electroosmosis in coated quartz capillaries

The effectiveness of various coatings for controlling the electroosmotic fluid flow that hinders electrophoretic processes is studied using analytical particle microelectrophoresis. The mobilities of 2-micron diameter glass and polystyrene latex spheres (exhibiting both negative and zero effective surface charge) were measured in 2-mm diameter quartz capillaries filled with NaCl solutions within the 3.5-7.8 pH range. It is found that capillary inner surface coatings using 5000 molecular weight (or higher) poly(ethylene glycol): significantly reduced electroosmosis within the selected pH range, were stable for long time periods, and appeared to be more effective than dextran, methylcellulose, or silane coatings.

Herren, Blair J.↗

Effect of conductivity and concentration on the sample stream in the transverse axis of a continuous flow electrophoresis chamber

The resolution of continuous flow electrophoresis systems is generally measured by the spread of the sample bands in the direction of the electrophoretic migration. This paper evaluates the cross section of the sample bands in the plane perpendicular to the flow and shows that the spread in the direction perpendicular to the migration increased significantly with the applied electric field. Concentrated samples of monodisperse latex particles and vinyltoluene T-butylstyrene particles in sample buffers of different electrical conductivities were used to map the shape of the sample bands relative to the zero electric field case. As the electric field was applied, the sample band spread from an initial diameter of only one-third the chamber thickness until it approached the chamber walls where electroosmosis significantly reduced the resolution of separation. It can be shown, however, that it is possible to minimize these distortions by careful sample preparation and experiment design.

Miller, Teresa Y.↗

Continuous flow electrophoresis system experiments on shuttle flights STS-6 and STS-7

A space continuous flow electrophoresis system (CFES) was developed that would incorporate specific modifications to laboratory instruments to take advantage of weightlessness. The specific objectives were to use a model sample material at a high concentration to evaluate the continuous flow electrophoresis process in the CFES instrument and compare its separation resolution and sample throughput with related devices on Earth and to expand the basic knowledge of the limitations imposed by fluid flows and particle concentration effects on the electrophoresis process by careful design and evaluation of the space experiment. Hemoglobin and polysaccharide were selected as primary samples. The results from space show a large band spread of the high concentration of the single species of hemoglobin that was due to the mismatch of electrical conductivity between the sample and the buffer. On STS-7 the major objective was to evaluate the influence of the electrical properties of the sample constituents on the resolution of the CFES. As expected, the polystyrene latex microspheres dispersed in a solution with 3 times the electrical conductivity of the curtain buffer separated with a larger band spread than in the 2nd experiment.

Snyder, Robert S.↗

Electrohydrodynamic distortion of sample streams in continuous flow electrophoresis

Continuous flow electrophoresis experiments were carried out, using an electrolyte and a sample both made of aqueous solutions of phosphate buffer (with polystyrene latex added for visibility), to investigate causes of the sample spreading in this procedure. It is shown theoretically that an electric field perpendicular to a circular filament of conducting fluid surrounded by a fluid of different conductivity produces an electrohydrodynamic flow, which distorts the filament into an ellipse. Experimental results were found to be fully consistent with theretical predictions. It was found that the rate of distortion of the sample stream into a ribbon was proportional to the square of the applied voltage gradient. Furthermore, the orientation of the ribbon depends on the ratios of dielectric constant and electrical conductivity between the buffer and the sample.

Rhodes, Percy H.↗

Online submicron particle sizing by dynamic light scattering using autodilution

Efficient production of a wide range of commercial products based on submicron colloidal dispersions would benefit from instrumentation for online particle sizing, permitting real time monitoring and control of the particle size distribution. Recent advances in the technology of dynamic light scattering (DLS), especially improvements in algorithms for inversion of the intensity autocorrelation function, have made it ideally suited to the measurement of simple particle size distributions in the difficult submicron region. Crucial to the success of an online DSL based instrument is a simple mechanism for automatically sampling and diluting the starting concentrated sample suspension, yielding a final concentration which is optimal for the light scattering measurement. A proprietary method and apparatus was developed for performing this function, designed to be used with a DLS based particle sizing instrument. A PC/AT computer is used as a smart controller for the valves in the sampler diluter, as well as an input-output communicator, video display and data storage device. Quantitative results are presented for a latex suspension and an oil-in-water emulsion.

Nicoli, David F.↗

Engineering specification and system design for CAD/CAM of custom shoes: UMC project effort

Further experimentations were made to improve the design and fabrication techniques of the integrated sole. The sole design is shown to be related to the foot position requirements and the actual shape of the foot including presence of neurotropic ulcers or other infections. Factors for consideration were: heel pitch, balance line, and rigidity conditions of the foot. Machining considerations were also part of the design problem. Among these considerations, widths of each contour, tool motion, tool feed rate, depths of cut, and slopes of cut at the boundary were the key elements. The essential fabrication techniques evolved around the idea of machining a mold then, using quick-firm latex material, casting the sole through the mold. Two main mold materials were experimented with: plaster and wood. Plaster was very easy to machine and shape but could barely support the pressure in the hydraulic press required by the casting process. Wood was found to be quite effective in terms of relative cost, strength, and surface smoothness except for the problem of cutting against the fibers which could generate ragged surfaces. The programming efforts to convert the original dBase programs into C programs so that they could be executed on the SUN Computer at North Carolina State University are discussed.

Bao, Han P.↗

Binding of alpha-fetoprotein by immobilized monoclonal antibodies during episodes of zero-gravity obtained by parabolic flight

Alpha-fetoprotein (AFP), a single-chain polypeptide which is synthesized by the liver and yolk sac of the human fetus, provided a model ligand for assessing the effects of microgravity on ligand binding to surface-immobilized model receptor molecules. Monoclonal antibodies, used as receptors for AFP, were immobilized by covalent attachment to latex microparticles. Zero gravity environment was obtained by parabolic flight aboard NASA 930, a modified KC-135 aircraft. Buring the onset of an episode of zero gravity, ligand and receptor were mixed. Timed incubation (20 s) was terminated by centrifugation, the supernatant removed, and microparticies were assessed for bound AFP by immunochemical methods. The extent of binding was not influenced by microgravity, when compared with 1-G controls, which suggests that aberrant cellular activities observed in microgravity are not the simple expression of altered macromolecular interactions.

Spooner, Brian S.↗

The fluid mechanics of continuous flow electrophoresis

The overall objective is to establish theoretically and confirm experimentally the ultimate capabilities of continuous flow electrophoresis chambers operating in an environment essentially free of particle sedimentation and buoyancy. The efforts are devoted to: (1) studying the effects of particle concentration on sample conductivity and dielectric constant. The dielectric constant and conductivity were identified as playing crucial roles in the behavior of the sample and on the resolving power and throughput of continuous flow devices; and (2) improving the extant mathematical models to predict flow fields and particle trajectories in continuous flow electrophoresis. A dielectric spectrometer was designed and built to measure the complex dielectric constant of a colloidal dispersion as a function of frequency between 500 Hz and 200 kHz. The real part of the signal can be related to the sample's conductivity and the imaginary part to its dielectric constant. Measurements of the dielectric constants of several different dispersions disclosed that the dielectric constants of dilute systems of the sort encountered in particle electrophoresis are much larger than would be expected based on the extant theory. Experiments were carried out to show that, in many cases, this behavior is due to the presence of a filamentary structure of small hairs on the particle surface. A technique for producing electrokinetically ideal synthetic latex particles by heat treating was developed. Given the ubiquitous nature of hairy surfaces with both cells and synthetic particles, it was deemed necessary to develop a theory to explain their behavior. A theory for electrophoretic mobility of hairy particles was developed. Finally, the extant computer programs for predicting the structure of electro-osmotically driven flows were extended to encompass flow channels with variable wall mobilities.

Saville, D. A.↗