ANSYS Explicit Modeling for Prospective SAVY Designs and Worst Case Impact Orientation during Drop

A preliminary experimental drop test of a new 5.5 gallon SAVY-4000 container at a 12 ft height resulted in an impact angle of approximately 26 degrees and significant deformation of the locking ring and locking collar. Subsequently, the SAVY failed leak tests following the drop test. Based on previous analyses on SAVY containers, the primary modes of failure were determined to be vertical drops directly over the lid for the larger diameter sizes. The tests were initially bounded by the 45 degree impact angle. It was necessary to determine if a new bounding case existed at or near an impact angle of 26 degrees. In addition to characterizing the drop angle, modifications to the existing SAVY components were applied and analyzed to determine if container deformations could be minimized. Figure 1 includes the primary drop configurations investigated. A parametric study was conducted to determine the sensitivity of lid and collar deformation as a function of impact angle.

42 ENGINEERING↗

Small-Scale Spray Releases: Additional Aerosol Test Results

One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. To expand the data set upon which the WTP accident and safety analyses were based, an aerosol spray leak testing program was conducted by Pacific Northwest National Laboratory (PNNL). PNNL’s test program addressed two key technical areas to improve the WTP methodology (Larson and Allen 2010). The first technical area was to quantify the role of slurry particles in small breaches where slurry particles may plug the hole and prevent high-pressure sprays. The results from an effort to address this first technical area can be found in Mahoney et al. (2012a). The second technical area was to determine aerosol droplet size distribution and total droplet volume from prototypic breaches and fluids, including sprays from larger breaches and sprays of slurries for which literature data are largely absent. To address the second technical area, the testing program collected aerosol generation data at two scales, commonly referred to as small-scale and large-scale. The small-scale testing and resultant data are described in Mahoney et al. (2012b) and the large-scale testing and resultant data are presented in Schonewill et al. (2012). In tests at both scales, simulants were used to mimic the relevant physical properties projected for actual WTP process streams.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Non-contact measurement of partial gas pressure and distribution of elemental composition using energy-resolved neutron imaging

Neutron resonance absorption imaging is a non-destructive technique that can characterize the elemental composition of a sample by measuring nuclear resonances in the spectrum of a transmitted beam. Recent developments in pixelated time-of-flight imaging detectors coupled with pulsed neutron sources pose new opportunities for energy-resolved imaging. In this paper we demonstrate non-contact measurements of the partial pressure of xenon and krypton gases encapsulated in a steel pipe while simultaneously passing the neutron beam through high-Z materials. The configuration was chosen as a proof of principle demonstration of the potential to make non-destructive measurement of gas composition in nuclear fuel rods. The pressure measured from neutron transmission spectra (~739 ± 98 kPa and ~751 ± 154 kPa for two Xe resonances) is in relatively good agreement with the pressure value of ~758 ± 21 kPa measured by a pressure gauge. This type of imaging has been performed previously for solids with a spatial resolution of ~ 100 μm. In the present study it is demonstrated that the high penetration capability of epithermal neutrons enables quantitative mapping of gases encapsulate within high-Z materials such as steel, tungsten, urania and others. This technique may be beneficial for the non-destructive testing of bulk composition of objects (such as spent nuclear fuel assemblies and others) containing various elements opaque to other more conventional imaging techniques. As a result, the ability to image the gaseous substances concealed within solid materials also allows non-destructive leak testing of various containers and ultimately measurement of gas partial pressures with sub-mm spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NREL 25-cm2 High-Pressure Low-Temperature Electrolysis Cell Hardware (Open Source)

This data resource describes an open-source cell hardware that enables low temperature electrolysis (LTE) testing at elevated pressures. Existing commercial options have several downsides when it comes to R&D testing. They are often not designed for repeated reassembly, may not be able to accommodate porous transport layers with different thicknesses, and do not give state-of-the-art performance. Therefore, this hardware was developed specifically with LTE R&D in mind and its design is being made available to the global LTE community. This work was planned and funded by the U.S. Department of Energy's H2NEW consortium (https://h2new.energy.gov/). The hardware design package (.zip file) details the drawings, auxiliary materials, and procedures required to fabricate, assemble, and operate the National Renewable Energy Laboratory's (NREL's) high-pressure low-temperature electrolysis cells. While the hardware itself—end plates, current collectors, flow fields, bolts and washers, tube fittings—is always the same, the assembly and operating procedures may change depending on the active materials being tested, especially for the membrane. Material-specific assembly and operating procedures will be posted to the H2NEW website as they are developed and validated. Disclaimer: The documents and drawings included in this download package describe a design for a low temperature electrolysis hardware that is intended to comply with leak testing according to ASME B31.1. Safe operation at ambient and elevated pressures is the sole responsibility of the end user, which should be evaluated on a case-by-case basis for each individual cell. Factors affecting the sealing capability may depend on, for example, machining quality, cell assembly components, operating conditions, and operating history. Operation at pressure should only be performed on qualified test stands by qualified operators. NREL/ALLIANCE FOR SUSTAINABLE ENERGY, LLC/DOE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND MAKES NO WARRANTY AS TO THE ACCURACY, COMPLETENESS, OR USEFULNESS OF ANY INFORMATION PROVIDED HEREIN. USE OF THIS PACKAGE IS AT THE USER’S OWN RISK.

08 HYDROGEN↗

Commissioning the cryogenic system of the first LHC sector

The LHC machine, composed of eight sectors with superconducting magnets and accelerating cavities, requires a complex cryogenic system providing high cooling capacities (18 kW equivalent at 4.5 K and 2.4 W at 1.8 K per sector produced in large cold boxes and distributed via 3.3-km cryogenic transfer lines). After individual reception tests of the cryogenic subsystems (cryogen storages, refrigerators, cryogenic transfer lines and distribution boxes) performed since 2000, the commissioning of the cryogenic system of the first LHC sector has been under way since November 2006. After a brief introduction to the LHC cryogenic system and its specificities, the commissioning is reported detailing the preparation phase (pressure and leak tests, circuit conditioning and flushing), the cool-down sequences including the handling of cryogenic fluids, the magnet powering phase and finally the warm-up. Preliminary conclusions on the commissioning of the first LHC sector will be drawn with the review of the critical points already solved or still pending. The last part of the paper reports on the first operational experience of the LHC cryogenic system in the perspective of the commissioning of the remaining LHC sectors and the beam injection test.

43 PARTICLE ACCELERATORS↗

Radiation Hardened Foam Cold Test Plan - Phase II: Foam Characterization Testing and Environmental Chamber Testing of FoamBag Fixative Foam

This document outlines the Phase II test objectives and implementation plan for a down-select foam fixative technology intended to facilitate activities in support of the Savannah River Site (SRS) F/H labs deactivation and decommissioning (D&D) efforts. It is a collaborative effort between Savannah River National Laboratory (SRNL), Florida International University (FIU), and the SRS F/H labs team intended to test and evaluate the potential of a polyurethane resin foam in mitigating the release of contamination during dismantling operations on radioactively contaminated piping in legacy facilities. The cold test plan addresses specific requirements highlighted by site and safety personnel and will be executed at FIU and SRNL test and lab facilities. Results from the cold tests will inform the hot test at F/H labs, which will use the foam fixative to confine and/or isolate residual contamination within a 3-dimensional void space of Hastelloy C-22 piping designated for removal from the area and transported to a designated disposal facility. Phase I testing was previously conducted using Hilti CP620 fixative foam. Results from Phase I testing indicate Hilti CP-620 fixative foam is incompatible with SRS site hot taps as an effective foam delivery method into Hastelloy C-22 piping. Phase II testing will be conducted using FoamBag TM fixative foam as an alternative fixative foam option. Phase II testing will address eight test objectives: (1) evaluation of the adhesion and bonding properties of FoamBag TM in Hastelloy C-22 piping, (2) evaluation of the adhesion of FoamBag TM in piping under various moisture conditions, (3) determination of the heat profile of FoamBag TM during curing, (4) determination of the internal pipe pressure after FoamBag TM deployment and curing, (5) conduct a leak test to determine if FoamBag TM is effective at creating a full seal within piping, (6) headspace testing of FoamBag TM to determine if there are any associated off-gas hazards during FoamBag TM curing, (7) conduct environmental chamber testing of FoamBag TM to understand how environmental parameters impacts FoamBag TM curing, and (8) conduct fire testing to evaluate FoamBag TM fire retardant characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Field Evidence for Strong Chemical Separation of Contaminants in the Hanford Vadose Zone

Water and chemical transport from a point source within vadose zone sediments at the Hanford Site in Washington State were examined with a leak test consisting of five 3800-L aliquots of water released at 4.5-m depth every week over a 4-wk period. The third aliquot contained bromide, D2O, and 87Sr. Movement of the tracers was monitored for 9 mo by measuring pore water compositions of samples from boreholes drilled 2 to 8 m from the injection point. Graded sedimentary layers acting as natural capillary barriers caused significant lateral spreading of the leak water. Shortly after injections were completed, D2O was found at the 9- to 11-m depth at levels in excess of 50% of the tracer aliquot concentration, while sediment layers with elevated water content at the 6- to 7-m depth had less than 3% of the D2O tracer concentration, suggesting deep penetration of the D2O tracer and limited mixing between different aliquots of leak fluids. Initially, high bromide concentrations decreased more rapidly over time than D2O, suggesting enhanced transport of bromide due to anion exclusion. No significant increase in 87Sr was detected in the sampled pore water, indicating strong retardation of Sr by the sediments. These results highlight some of the processes strongly affecting chemical transport in the vadose zone and demonstrate the significant separation of contaminant plumes that can occur.

Conrad, Mark E↗

Radiation Hardened Foam Cold Test Plan – Phase-I: Foam Adhesion, Contamination Fixation, Moisture Stresses, Pipe Cutting, and Thermal Profile Testing

This document outlines the Phase-I test objectives and implementation plan for a down-selective foam fixative technology intended to facilitate activities in support of the Savannah River Site (SRS) F/H labs deactivation and decommissioning (D&D) efforts. It is a collaborative effort between Savannah River National Laboratory (SRNL), Florida International University (FIU), and the SRS F/H labs team intended to test and evaluate the potential of an intumescent, fire-retardant foam in mitigating the release of contamination during dismantling operations on radioactively contaminated piping in legacy facilities. The cold test plan addresses specific requirements highlighted by site and safety personnel and will be executed in FIU’s Outdoor Test and Evaluation Facility using a mock-up that replicates the operational conditions at the proposed hot test location at F/H labs. Results from the cold test plan will inform the hot test at F/H labs, which will use the foam fixative to confine and/or isolate residual contamination within a 3-dimensional void space of Hastelloy C-22 piping designated for removal from the site and transported to a proper disposal facility. Phase-I testing will address eight test objectives: (1) evaluation of the adhesion and bonding properties of foam fixative in piping, (2) evaluation of the adhesion of the foam fixative in piping under varying moisture conditions, (3) determination of the heat profile of the foam fixative during curing, (4) determination of the relationship between pipe diameter and foam fixative quantity, (5) determination of the internal pipe pressure after foam deployment and curing, (6) development of a leak test standard operating procedure to test for the effectiveness of the foam plug, (7) initiation of a literature review to determine if using a hot tap is a viable method to deliver foam into piping, and (8) initiation of a 10-foot mock up test that will be used in Phase-II cold testing. The cold test will be conducted at FIU and all testing activities will comply with SRNL Conduct of R&D Protocols (SRNL-IM-2020-00019).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Novel Technology of Non-Contact Real-Time Radiation Damage Sensor for High Power Targets

High-power proton beams planned for forthcoming long-baseline neutrino experiments will subject solid targets to unprecedented radiation damage, threatening reliability and increasing costs. To address this challenge, we are building a real-time, non-contact sensor that tracks damage by measuring broadband laser reflectivity changes from the target surface. A low-power super-continuum Class 3B laser illuminates the sample inside a vacuum test chamber while a high-resolution fiber-coupled spectrometer captures S- and P-polarized light; spectral shifts reveal defect-driven variations in optical constants. My internship goal is to design, build, and commission this prototype by implementing a laser-safety interlock and light shield, integrating remote-operation cameras, and fabricating modular 3-D-printed mounts that enable tool-free swaps without disturbing alignment. The laser, spectrometer, and vacuum chamber have been delivered; interlock hardware, cameras, and mounts are in final assembly, and leak testing of the chamber is underway. Upcoming work will focus on initial calibration of the sensor and executing first beam-irradiation studies.

Pumarino, Rafael↗

LANL Phase 3 Test Plan For Container Loading to Support the Fire-Induced Pressure Response and Failure Characterization of PCV/SCV/3013 Containers

Fire testing of 3013 containers loaded with surrogate materials and water will be conducted to determine the response of 3013 containers stored in K-Area Complex (KAC) to a facility fire. Based on the proposal for the test configuration and loading, the objectives of the fire test are as follows: 1. “To increase understanding about the pressure and temperature conditions at which failure occurs; 2. To determine the allowable moisture for which failure will not occur under specified fire conditions, and 3. To increase understanding regarding the effects of salts on the pressurization, corrosion, and potential failure of the container.” Surrogate materials will be prepared at Los Alamos National Laboratory (LANL) and loaded in the 3013 containers. The containers will then be welded at LANL and shipped to Savannah River Site (SRS) for the installation of fittings and leak testing.

42 ENGINEERING↗

Additively Manufactured Intensified Device for Enhanced Carbon Capture

Additively manufactured packed bed devices for the enhancement of carbon capture were successfully developed, built, characterized, and tested in this project. The objective was to demonstrate that in situ cooling of chemical absorption could have beneficial effects on the absorption rate of CO 2 . This was achieved in two stages, divided between FY 2018 and FY 2019. First, the feasibility of printing conventional packing elements was investigated, and the core hydrodynamic metrics were experimentally validated. The data obtained in those studies informed the operating conditions set for the next stage, which was to validate the efficacy of in situ cooling provided by an additively manufactured packed bed element, referred to as the intensified device. The intensified device is designed to enable heat exchange between an internally flowing coolant and the gas-liquid system flowing on the external corrugated surface of the packing. Polymer and metal were both considered as the base materials for the device, and comparative studies on hydrodynamic properties were performed. These considerations, as well as thermal properties and leak tests led to aluminum being chosen as the base material for experimental validation of capture enhancement. The experimental validation was first conducted under non-reactive conditions, and after establishing heat-exchange capabilities, was subsequently conducted under reactive conditions. These studies demonstrated that in situ cooling can benefit absorption given the appropriate operating conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Friction surfacing and cold spray deposition for surface crack repair in austenitic stainless steels

Two technologies, friction surfacing (FS) and cold spray deposition (CSD), have been investigated for field repair of cracks in 304L austenitic stainless steel. Both technologies are low-heat-input, solid-state technologies that do not introduce the detrimental effects of solidification, such as compositionally segregated microstructures and shrinkage stresses. Friction surfacing was performed using a 304L stainless steel rod over the substrate of the same material. Further, the process was performed at a high spindle speed of 20,000 RPM allowing for process forces below 500N to be used effectively. Spherical gas-atomized 304L stainless steel powder, in size range of 25–44 µm, was used as feedstock powder for the cold spray process for deposition on 304L substrates. Both technologies showed leak-tight crack repair capabilities on ~30–50 µm wide simulated through-crack specimens based on helium leak tests.

36 MATERIALS SCIENCE↗

Development of Electroplated Au Capsule Fill Tube Assemblies (CFTA) for the Double Shell ICF Concept on NIF

Current capsules used at the National Ignition Facility (NIF) utilize a single shell design comprised of a single ablator material. Although single shell designs are currently the standard design, they suffer from several physics disadvantages, such as sensitivity to asymmetries and instabilities. The double shell is a proposed design utilizing a high-Z inner metal shell with a low-Z outer shell that is intended to mitigate the issues associated with typical single shell designs. Electroplating is one method that can be utilized to fabricate high-Z metal shells. Au is one particular material that can be electroplated with high density and uniformity. Capsule fill tube assemblies (CFTAs) built from these Au shells have passed all cryogenic leak tests. The shells have a low native surface roughness and are free of voids. Lastly, Au shells have been successfully fabricated, characterized, and built into CFTAs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Qmax Derivative Leak Tester v. 1.0

The Qmax Derivative Leak Tester is an automated tool developed to quantitatively verify the hermeticity of sealed parts without many of the pitfalls that accompany standard leak testing techniques. Sandia National Laboratories is a multi-mission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525. SAND2021-0477 O

Poulter, GregoryA.↗

Performance of Bolted Closure Joint Elastomers Under Cask Aging Conditions

The bolted closure joint of a bare spent fuel cask is susceptible to age-related degradation and potential loss of confinement function under long-term storage conditions. Elastomeric seals, a component of the joint typically used to facilitate leak testing of the primary seal that includes the metallic seal and bolting, is susceptible to degradation over time by several mechanisms, principally via thermo-oxidation, stress-relaxation, and radiolytic degradation under time and temperature condition. Irradiation and thermal exposure testing and evaluation of an ethylene-propylene diene monomer (EPDM) elastomeric seal material similar to that used in the CASTOR® V/21 cask for a matrix of temperature and radiation exposure conditions relevant to the cask extended storage conditions, and development of semiempirical predictive models for loss of sealing force is in progress. A special insert was developed to allow Compressive Stress Relaxation (CSR) measurements before and after the irradiation and/or thermal exposure without unloading the elastomer. A condition of the loss of sealing force for the onset of leakage was suggested. The experimentation and modeling being performed could enable acquisition of extensive coupled aging data as well as an estimation of the timeframe when loss of sealing function under aging (temperature/radiation) conditions may occur.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Basic Design Layout of a Modular Pumped Hydro Teaching Unit

This work was originally completed in July 2015 as a proposal to Santa Fe Community College (SFCC) for their engineering program and a follow up to a feasibility study completed for the Community College the year earlier as indicated below. The work was ahead of its time and funding was hard to obtain to implement a project. This work is now being formally released for distribution to a wider audience based on the evolving circumstances in greater society that now favor this approach with funding more readily available. Due to the distribution outside of SFCC, specific architectural drawing sets of the pertinent buildings called out in the design have been removed. No changes to the design have been made. The design layout utilizing a building is not meant to limit the implementation of the design. The elevation difference required may be obtained with a building, a small hill, jacking up the upper tank, or similar means. The design presented is a basic design, identifying major components and how they are connected together. The user may change components under their own liability. All local applicable codes and standards must be followed when building an actual unit, under the authority of a responsible engineer or owner. Appropriate measures must be followed to protect people from hazards such as electricity, water pressure, and general construction. A leak test to verify water tightness of the system should be conducted prior to any operations. The vision of this design is to allow a class of 10 to 15 students to construct the assembly within a month or so time period, and then learn to operate the assembly at their school location under the guidance of their instructor. This will allow the students to learn about the practical concept of storing electricity with water, and gain a hands on experience of the real world challenges faced with full Modular Pumped Hydro Projects.

13 HYDRO ENERGY↗

Fabrication and Characterization of Plutonium Targets for Irradiation in the Flattop Critical Assembly

In FY16, Pu targets were fabricated in support of the Nuclear Physics: Cumulative Fission Product Yields (Fission R-values) task of the F2016 venture project; these targets are suitable for irradiation in the Flattop critical assembly at the Nevada National Security Site (NNSS). This report documents an overview of the target design, preparation of the Pu metal materials by removing the oxide layer and appropriate sizing for the target holders, target fabrication including filling an inner aluminum cup with the Pu material and the sealing of an outer stainless steel capsule, target assay using gamma spectroscopy, and the He leak testing of the final targets. Four targets were fabricated with two containing 99% 239 Pu metal and two containing 93% 239 Pu metal. Additional samples of each material were set aside for mass spectrometric analysis at PNNL and Los Alamos National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FY2023 Status Report: Model 9975 O-Ring Fixture Long-Term Leak Performance

Leak testing experiments to monitor the aging performance of Viton ® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗