Search NASA⌕ Search

SEARCH · Search NASA

Results for “Light amplification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Solitary Magnetic Structures at Quasi–Parallel Collisionless Shocks: Formation

Solitary magnetic structures known as SLAMS (short large-amplitude magnetic structures) have been considered as essential elements of collisionless shocks with quasi-parallel geometries. Yet the physics underlying their formation remains an open question. In this paper, we use measurements from the magnetospheric multiscale mission combined with fully kinetic simulations to study the formation of SLAMS. We find that gyro-resonance between solar wind ions and right-hand circularly polarized electromagnetic waves results in magnetic field amplification. Gyro-trapping by the growing magnetic field builds up the plasma density that further enhances the current and field. The solitary nature of SLAMS stems from a beat-like magnetic field envelope where the maximum sets the initial location for nonlinear growth. Our results present a conceptual advance on SLAMS, and may shed new light on the open question of magnetic field amplification at astrophysical shocks.

58 GEOSCIENCES↗

Deep UV light generation by a fiber/bulk hybrid amplifier at 199 nm

A high-pulse-repetition-frequency (PRF) pulsed light source in the deep ultraviolet region has been realized by a multiple wavelength conversion technique using a hybrid fiber/bulk amplifier system. Output of 199 nm with a power of 50 mW was achieved at 2.4 MHz PRF. The 1 {mu}m amplifier consisted of a Yb-doped fiber amplifier and a Nd-doped YVO4 amplifier. A 1.5 {mu}m fiber master-oscillator power amplifier was employed as the other fundamental source. The amplifiers exhibited good amplification properties in pulse energy, polarization extinction ratio, and spectrum for nonlinear wavelength conversion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Specification and R and D Program on Magnet Alignment Tolerances for NSLS-II

The NSLS-II light source is a proposed 3 GeV storage ring, with the potential for ultra-low emittance. Despite the reduced emittance goal for the bare lattice, the closed orbit amplification factors are on average >55 in both planes, for random quadrupole alignment errors. The high chromaticity will also require strong sextupoles and the low 3 GeV energy will require large dynamic and momentum aperture to insure adequate lifetime. This will require tight alignment tolerances ({approx} 30{micro}m) on the multipole magnets during installation. By specifying tight alignment tolerances of the magnets on the support girders, the random alignment tolerances of the girders in the tunnel can be significantly relaxed. Using beam based alignment to find the golden orbit through the quadrupole centers, the closed orbit offsets in the multipole magnets will then be reduced to essentially the alignment errors of the magnets, restoring much of the dynamic aperture and lifetime of the bare lattice. Our R&D program to achieve these tight alignment tolerances of the magnets on the girders using a vibrating wire technique, will be discussed and initial results presented.

43 PARTICLE ACCELERATORS↗

Parallel parametric amplification of coherently excited propagating spin waves in a microscopic Ni{sub 81}Fe{sub 19} waveguide

We present parallel parametric amplification of coherently excited, propagating spin waves in a microstructured magnonic Ni{sub 81}Fe{sub 19} waveguide. Amplification is achieved by the pumping field generated by a microwave current flowing through a Cu micro-stripline underneath the waveguide. By employing microfocussed Brillouin light scattering spectroscopy, we investigate the spatial decay of the propagating spin waves and their amplification by means of parallel pumping. We analyze the dependence of the intensity of the amplified spin waves on the spin-wave excitation power, pumping power, and pumping duration, revealing the most efficient working point for a noise-free amplification. This paves the way for a frequency selective amplification of spin waves in microstructured magnonic circuits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Coherent anti-Stokes Raman scattering with squeezed light: CARS for quantum-enhanced spectroscopy and imaging

We theoretically investigate quantum-enhanced coherent anti-Stokes Raman scattering (CARS) using squeezed light to amplify vibrational transition rates at low photon flux. Quantum sensing approaches are needed for nondestructive nanometrology such as in bioimaging where reduced photodamage is desired while retaining resolution and sensitivity. We analyze both single-mode squeezing applied to the pump field and two-mode squeezing between the pump and Stokes fields. We also show that the ordering of displacement and squeezing operations—whether displacement precedes squeezing or squeezing precedes displacement—has an impact on the resulting CARS transition amplitudes due to a difference in the photon number and the quantum-enhancement coefficients, with the latter offering a stronger enhancement in the case of two modes squeezing of the pump and Stokes under experimentally accessible conditions. Furthermore, our calculations capture these quantum enhancements through the intrinsic photon-number correlations of squeezed light, eliminating the need for interferometric detection or higher pump powers that are otherwise required to reach comparable sensitivities in classical CARS. Finally, we outline a quantum plasmonic extension of our model in which local field enhancements caused by surface plasmon excitation in metallic nanoparticles can be incorporated via mode-selective field amplification factors, offering a pathway toward combining squeezed-light quantum optics with surface-enhanced nanoscale spectroscopy and imaging.

Atomic & molecular structure↗

Photorefractive deceleration of light pulses

We theoretically study the effect of light deceleration in photorefractive nonlinear media. This includes consideration of different types of the photorefractive nonlinear response, different wave interaction schemes, and an analysis of the influence of the input parameters, such as the input temporal pulse width and the coupling strength, on the output pulse characteristics: the time delay, the propagation velocity, the amplification factor, and the output width. We show that photorefractive light deceleration has numerous advantages over other known techniques. It works already at low intensities, at room temperature, and within wide spectral ranges and offers a vast variety of handles for manipulating light pulses. An analogy with the light deceleration method based on the quantum effect of electromagnetically induced transparency in ultracold resonant gases is also considered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spin optodynamics analog of cavity optomechanics

The dynamics of a large quantum spin coupled parametrically to an optical resonator is treated in analogy with the motion of a cantilever in cavity optomechanics. Distinct spin optodynamic phenomena are predicted, such as cavity-spin bistability, optodynamic spin-precession frequency shifts, coherent amplification and damping of spin, and the spin optodynamic squeezing of light.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photomultiplier Tubes: Calibration and Neutrino Physics

Photomultiplier Tubes are devices designed to amplify very small light signals, on the order of single photons, to levels that are detectable by conventional electronics. Such a high level of amplification, however, comes with a quite a few potential problems, as the relationship between a light signal in and the current out- the response of the system- can be difficult to determine, meaning that photomultiplier tubes' use in scientific research requires a great deal of sensitive calibration. Once calibrated, the photomultiplier tube is a tool that can be used on a number of interesting problems, including the field of neutrino physics. This work deals with the use of photomultiplier tubes' use in the upcoming Double Chooz experiment to determine the mixing angle theta{sub 13}, between different neutrino mass eigenstates. Calibration of the tubes requires measurement of the charge characteristics, most notably, the gain, pedestal, and the dark rate of a tube. Moreover, for all modern tubes, there is an additional feature which can be used to calibrate the system, the single photo electron peak, which describes the response of the tube to a single photon. Some theories predict higher order effects, in addition to the single photoelectron peak, including things like incomplete multiplication of a single photon electron, features which are theoretically able to be determined by a detailed examination of the single photoelectron peak. This paper goes through the methods of calibrating a phototubes both with and without a single photoelectron peak, and is unable to determine conclusively whether or not partial multiplication is able to explain certain features of photomultiplier tubes with a single photoelectron peak.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser-driven plasma sources of intense, ultrafast, and coherent radiation

High-power lasers can deliver extreme light intensities, but avoiding damage in optical components requires large beam sizes, hindering further advances. The use of plasma as a medium for generating and manipulating light avoids the damage thresholds of solid materials and can support extraordinarily bright radiation. In this work, we discuss here how parametric plasma amplification and relativistic high-order harmonic generation offer paths to the development of light sources with peak powers beyond the capabilities of solid-state optics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-beam effects on backscatter and its saturation in experiments with conditions relevant to ignition

To optimize the coupling to indirect drive targets in the National Ignition Campaign (NIC) at the National Ignition Facility, a model of stimulated scattering produced by multiple laser beams is used. The model has shown that scatter of the 351 nm beams can be significantly enhanced over single beam predictions in ignition relevant targets by the interaction of the multiple crossing beams with a millimeter scale length, 2.5 keV, 0.02 - 0.05 x critical density, plasma. The model uses a suite of simulation capabilities and its key aspects are benchmarked with experiments at smaller laser facilities. The model has also influenced the design of the initial targets used for NIC by showing that both the stimulated Brillouin scattering (SBS) and stimulated Raman scattering (SRS) can be reduced by the reduction of the plasma density in the beam intersection volume that is caused by an increase in the diameter of the laser entrance hole (LEH). In this model, a linear wave response leads to a small gain exponent produced by each crossing quad of beams (<~1 per quad) which amplifies the scattering that originates in the target interior where the individual beams are separated and crosses many or all other beams near the LEH as it exits the target. As a result all 23 crossing quads of beams produce a total gain exponent of several or greater for seeds of light with wavelengths in the range that is expected for scattering from the interior (480 to 580 nm for SRS). This means that in the absence of wave saturation, the overall multi-beam scatter will be significantly larger than the expectations for single beams. The potential for non-linear saturation of the Langmuir waves amplifying SRS light is also analyzed with a two dimensional, vectorized, particle in cell code (2D VPIC) that is benchmarked by amplification experiments in a plasma with normalized parameters similar to ignition targets. The physics of cumulative scattering by multiple crossing beams that simultaneously amplify the same SBS light wave is further demonstrated in experiments that benchmark the linear models for the ion waves amplifying SBS. Here, the expectation from this model and its experimental benchmarks is shown to be consistent with observations of stimulated Raman scatter in the first series of energetic experiments with ignition targets, confirming the importance of the multi-beam scattering model for optimizing coupling.

42 ENGINEERING↗

Envelope matching for enhanced backward Raman amplification by using self-ionizing plasmas

Backward Raman amplification (BRA) in plasmas has been promoted as a means for generating ultrapowerful laser pulses. For the purpose of achieving the maximum intensities over the shortest distances, an envelope matching between the seed pulse and the amplification gain is required, i.e., the seed pulse propagates at the same velocity with the gain such that the peak of the seed pulse can always enjoy the maximum gain. However, such an envelope matching is absent in traditional BRA because in the latter the amplification gain propagates at superluminous velocity while the seed pulse propagates at the group velocity, which is less than the speed of light. It is shown here that, by using self-ionizing plasmas, the speed of the amplification gain can be well reduced to reach the envelope matching regime. This results in a favorable BRA process, in which higher saturated intensity, shorter interaction length and higher energy-transfer efficiency are achieved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deep Diversity: Novel Approach to Overcoming the PCR Bias Encountered During Environmental Analysis of Microbial Populations for Alpha-Diversity

Alpha-diversity studies are of crucial importance to environmental microbiologists. The polymerase chain reaction (PCR) method has been paramount for studies interrogating microbial environmental samples for taxon richness. Phylogenetic studies using this technique are based on the amplification and comparison of the 16S rRNA coding regions. PCR, due disproportionate distribution of microbial species in the environment, increasingly favors the amplification of the most predominant phylotypes with every subsequent reaction cycle. The genetic and chemical complexity of environmental samples are intrinsic factors that exacerbate an inherit bias in PCR-based quantitative and qualitative studies of microbial communities. We report that treatment of a genetically complex total genomic environmental DNA extract with Propidium Monoazide (PMA), a DNA intercalating molecule capable of forming a covalent cross-linkage to organic moieties upon light exposure, disproportionally inactivates predominant phylotypes and results in the exponential amplification of previously shadowed microbial ?-diversity quantified as a 19.5% increase in OUTs reported via phylogenetic screening using PhyloChip.

phylogenetic microarray technologies↗

Robust Quantum Control via Multipath Interference for Thousandfold Phase Amplification in a Resonant Atom Interferometer

We introduce a novel technique for enhancing the robustness of light-pulse atom interferometers against the pulse infidelities that typically limit their sensitivities. The technique uses quantum optimal control to favorably harness the multipath interference of the stray trajectories produced by imperfect atom-optics operations. We apply this method to a resonant atom interferometer and achieve thousandfold phase amplification, representing a 50-fold improvement over the performance observed without optimized control. Moreover, we find that spurious interference can arise from the interplay of spontaneous emission and many-pulse sequences and demonstrate optimization strategies to mitigate this effect. Given the ubiquity of spontaneous emission in quantum systems, these results may be valuable for improving the performance of a diverse array of quantum sensors. We anticipate our findings will significantly benefit the performance of matter-wave interferometers for a variety of applications, including dark matter, dark energy, and gravitational wave detection.

47 OTHER INSTRUMENTATION↗

Multichannel Doppler transmission grating spectrometer at the Alcator C-Mod tokamak

Upgrades to an existing transmission grating spectrometer for visible light used for Doppler velocity and temperature measurements at the Alcator C-Mod tokamak are given. These include a new Princeton Instruments Photonmax 512B charge-coupled device and a four channel fiber optic input. These together allow improvements to the signal level, time resolution, and the number of spatial channels. The fiber optic input allows four simultaneous spatial channels each of which offers a larger percentage of input light flux when compared to the standard fiber slit combination. The ''on chip'' amplification combined with versatile pixel binning further increases the signal to noise ratio allowing a continuous acquisition of spectra every 8 ms. The error bars for extracted velocity and temperature values are potentially smaller owing to the smaller pixel size and increased light flux which allow a more detailed line shape and simplifies line fitting. Examples of time and space resolved spectra are shown and further improvements are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrading a high-throughput spectrometer for high-frequency (<400 kHz) measurements

The upgraded spectrometer used for charge exchange recombination spectroscopy on the Madison Symmetric Torus resolves emission fluctuations up to 400 kHz. The transimpedance amplifier’s cutoff frequency was increased based upon simulations comparing the change in the measured photon counts for time-dynamic signals. We modeled each signal-processing stage of the diagnostic and scanned the filtering frequency to quantify the uncertainty in the photon counting rate. This modeling showed that uncertainties can be calculated based on assuming each amplification stage is a Poisson process and by calibrating the photon counting rate with a DC light source to address additional variation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

COMPACT, TUNABLE COMPTON SCATTERING GAMMA-RAY SOURCES

Recent progress in accelerator physics and laser technology have enabled the development of a new class of gamma-ray light sources based on Compton scattering between a high-brightness, relativistic electron beam and a high intensity laser pulse produced via chirped-pulse amplification (CPA). A precision, tunable gamma-ray source driven by a compact, high-gradient X-band linac is currently under development at LLNL. High-brightness, relativistic electron bunches produced by the linac interact with a Joule-class, 10 ps laser pulse to generate tunable {gamma}-rays in the 0.5-2.5 MeV photon energy range via Compton scattering. The source will be used to excite nuclear resonance fluorescence lines in various isotopes; applications include homeland security, stockpile science and surveillance, nuclear fuel assay, and waste imaging and assay. The source design, key parameters, and current status are presented.

42 ENGINEERING↗

CHARACTERIZATION OF THE RESONANT CAUSTIC PERTURBATION

Four of nine exoplanets found by microlensing were detected by the resonant caustic, which represents the merging of the planetary and central caustics at the position when the projected separation of a host star and a bounded planet is s approx 1. One of the resonant caustic lensing events, OGLE-2005-BLG-169, was a caustic-crossing high-magnification event with A {sub max}approx 800 and the source star was much smaller than the caustic, nevertheless the perturbation was not obviously apparent on the light curve of the event. In this paper, we investigate the perturbation pattern of the resonant caustic to understand why the perturbations induced by the caustic do not leave strong traces on the light curves of high-magnification events despite a small source/caustic size ratio. From this study, we find that the regions with small magnification excess around the center of the resonant caustic are rather widely formed, and the event passing the small-excess region produces a high-magnification event with a weak perturbation that is small relative to the amplification caused by the star and thus does not noticeably appear on the light curve of the event. We also find that the positive excess of the inside edge of the resonant caustic and the negative excess inside the caustic become stronger and wider as q increases, and thus the resonant caustic-crossing high-magnification events with the weak perturbation occur in the range of q <= 10{sup -4}. We determine the probability of the occurrence of events with the small excess |epsilon| <= 3% in high-magnification events induced by a resonant caustic. As a result, we find that for Earth-mass planets with a separation of approx2.5 AU the resonant caustic high-magnification events with the weak perturbation can occur with a significant frequency.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of the naive murine antibody repertoire using unamplified high-throughput sequencing

Antibody specificity and diversity are generated through the enzymatic splicing of genomic gene segments within each B cell. Antibodies are heterodimers of heavy- and light-chains encoded on separate loci. We studied the antibody repertoire from pooled, splenic tissue of unimmunized, adult female C57BL/6J mice, using high-throughput sequencing (HTS) without amplification of antibody transcripts. We recovered over 90,000 heavy-chain and over 135,000 light-chain immunoglobulin sequences. Individual V-, D-, and J-gene segment usage was uniform among the three mouse pools, particularly in highly abundant gene segments, with low frequency V-gene segments not being detected in all pools. Despite the similar usage of individual gene segments, the repertoire of individual B-cell CDR3 amino acid sequences in each mouse pool was highly varied, affirming the combinatorial diversity in the B-cell pool that has been previously demonstrated. There also was some skewing in the V-gene segments that were detected depending on chromosomal location. This study presents a unique, non-primer biased glimpse of the conventionally housed, unimmunized antibody repertoire of the C57BL6/J mouse.

Science & Technology - Other Topics↗