Search NASA⌕ Search

SEARCH · Search NASA

Results for “Limit of detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Pisces VII: discovery of a possible satellite of Messier 33 in the DESI legacy imaging surveys

ABSTRACT We report deep imaging observations with DOLoRes@TNG of an ultra-faint dwarf satellite candidate of the Triangulum galaxy (M33) found by visual inspection of the public imaging data release of the DESI Legacy Imaging Surveys. Pisces VII/Triangulum (Tri) III is found at a projected distance of $72\, {\rm kpc}$ from M33, and using the tip of the red giant branch method, we estimate a distance of $D=1.0^{+0.3}_{-0.2}\, {\rm Mpc}$, meaning the galaxy could either be an isolated ultra-faint or the second known satellite of M33. We estimate an absolute magnitude of MV = −6.1 ± 0.2 if Pisces VII/Tri II is at the distance of M33, or as bright as MV = −6.8 ± 0.2 if the galaxy is isolated. At the isolated distance, it has a physical half-light radius of $r_{\rm h}=131\pm 61\, {\rm pc}$ consistent with similarly faint galaxies around the Milky Way. As the tip of the red giant branch is sparsely populated, constraining a precision distance is not possible, but if Pisces VII/Tri III can be confirmed as a true satellite of M33, it is a significant finding. With only one potential satellite detected around M33 previously (Andromeda XXII/Tri I), it lacks a significant satellite population in stark contrast to the similarly massive Large Magellanic Cloud. The detection of more satellites in the outskirts of M33 could help to better illuminate if this discrepancy between expectation and observations is due to a poor understanding of the galaxy formation process, or if it is due to the low luminosity and surface brightness of the M33 satellite population which has thus far fallen below the detection limits of previous surveys. If it is truly isolated, it would be the faintest known field dwarf detected to date.

Martínez-Delgado, David↗

ToF-SIMS in material research: A view from nanoscale hydrogen detection

Hydrogen in materials has attracted tremendous interest as its incorporation leads to significant alterations in nanoscale structure, composition, and chemistry, impacting functional properties. It has also been integral to nuclear fusion reactors and is considered a future clean energy source. However, nanoscale characterization and manipulation of hydrogen in materials are challenging as only a selected few analytical techniques can readily detect hydrogen, among which time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a unique and powerful one due to its excellent detection limit along with decent depth and lateral resolutions. Here, in this review, we discuss, using selected examples, how to detect and quantify hydrogen in materials by ToF-SIMS and its impact on revealing the hydrogenation/protonation-induced novel functional states in different classes of materials. In addition, we present our protocols on sample preparation and experimental conditions optimization, allowing us to achieve the best possible results. Finally, we highlight future research directions that can lead to the discovery of novel functional states and ultimately provide a deeper understanding of scientific questions in materials science.

36 MATERIALS SCIENCE↗

Data Summary Report for Soil and Slab Sampling at Former Building 175

Lawrence Livermore National Security (LLNS) and the U.S. Department of Energy (DOE) are in the process of returning the area where Building 175 existed to beneficial use for future site development. The completed assessment will help LLNS and DOE to outline project scope and costs associated with the removal, characterization, and disposal of materials generated when the concrete slab for the former building and any associated remaining subsurface structures are demolished. Slab removal under the Transition & Disposition process requires full screening for potential site contamination to determine appropriate future land use. Borehole locations and depths were designed to correctly assess DOE’s future liability for characterizing residual vadose zone contamination. If a residual source area is identified at depth, DOE will need to evaluate the additional cost of future subsurface cleanup (with limited access) due to planned development. This is necessary to leave the location in a “ready-to-build” status. As a result, Phase II sampling requirements may in some cases extend beyond the construction zone required for slab removal to ensure the necessary due diligence. To avoid the potential spread of contamination and/or the creation of an environmental release by impacting the integrity of known contamination areas (e.g., pit within room 102 and the east to west boundary seam), these locations were not sampled for this project. During demolition of the slab, these locations and their underlying soils should be further evaluated. The assessment was conducted in accord with the May 2022 Lawrence Livermore National Laboratory Former Building 175 Assessment Soil Sampling and Analysis Plan / Quality Assurance Plan. Thirty-six, direct-push borings were advanced, along with collecting concrete (where present) and soil samples for laboratory analyses. Thirty-two of the borings were advanced to a depth of 25 feet below ground (bgs), and four borings were advanced to a depth of 55 feet bgs. The concrete slab for former Building 175 ranged from approximately 8 inches to over two feet in thickness. Soils encountered during the investigation consisted primarily of clayey silt, with interbeds of sandy gravel and silty sand to the total depth explored of 55 feet bgs. Field photoionization detector readings – checking for volatile organic compound (VOC) vapors in soils, ranged from zero (0) to a peak of 33 parts per million at 25 feet bgs in boring PC-B175- 028. The cause for the peak reading is unknown, however, no visually discolored or odorous soils were encountered during the assessment and all VOC results were below Lawrence Livermore National Laboratory’s (LLNL’s) Soil Screening and Management Plan (SSMP) soil screening levels (SSL). Groundwater was not encountered during the assessment and is expected to occur at roughly 65 feet bgs in the project area. No metals were detected at concentrations of concern in the concrete core samples collected and analyzed. Low gross alpha and beta activity concentrations were detected in the concrete core samples collected and analyzed. The detected activity concentrations would appear to be from naturally occurring radioactive isotopes, i.e., potassium 40, present in the raw materials used to make concrete and not artificially added. Tritium was not detected above the testing laboratory's Method Detection Limit (MDL) in any of the concrete core samples collected and analyzed. The radioactive isotopes - actinium 228, bismuth 214, lead 212, lead 214, potassium 40, radium 226, radium 228, and thallium 208, were detected at low activity concentrations in the concrete core samples analyzed. Based on the detected activity concentrations, the isotopes would appear to be naturally occurring in the raw materials used to make concrete and not artificially added. Acetone – a common laboratory contaminant, was detected in nine of the soil samples collected and analyzed. Concentrations of two other volatile organic compounds (benzene and tetrachloroethene) were detected in five of the soil samples analyzed. All concentrations were below SSLs. Total petroleum hydrocarbons as diesel range organics were detected at 43.9 milligrams per kilogram (mg/kg) in the 20-foot bgs duplicate sample from boring PC-B175-007. Total petroleum hydrocarbons as motor oil were detected at 7.20 mg/kg in the 15-foot bgs routine sample from boring PC-B175-001, and at 20.7 mg/kg in the 20-foot bgs duplicate sample from boring PC-B175-007. The SSL for diesel-range TPHs is 260 mg/kg. LLNL does not have an SSL for motor oil range TPHs. No indications of a release, e.g., visibly stained, or odorous soil, were present at the boring locations. No samples collected contained polychlorinated biphenyls (PCBs) in concentrations above the laboratory reporting limit. Arsenic was detected above its SSL of 8.51 mg/kg in the 25-foot bgs routine sample collected from boring PC-B175-023. Nickel was detected above its SSL of 86.0 mg/kg in the 10-foot bgs routine sample from boing PC-B175-005, the 20-foot bgs routine sample from boring PC-B175-025, and the 25-foot bgs routine sample from boring PC-B175-034. The detected concentrations, however, were well below ten times (10x) their respective STLCs. Gross alpha and/or gross beta were detected above their respective SSL activity concentrations in three routine soil samples. Retesting (two per sample) of the samples showed that the initial reported activity concentrations were anomalous. Tritium was not detected in any of the routine or duplicate soil samples collected and analyzed during the investigation. The radioactive isotopes - actinium 228, bismuth 212 and 214, lead 212 and 214, potassium 40, radium 224, 226 and 228, thallium 208, thorium 234 and uranium, were detected at low activity concentrations in the soil samples analyzed for radioactive constituents. The detected isotopes and their associated activity concentrations are typical of those naturally occurring in the marine-type sedimentary deposits underlying the Livermore Valley. No radiological controls are necessary for the soil evaluated.

54 ENVIRONMENTAL SCIENCES↗

Atomically Precise Hexanuclear Ce(IV) Clusters as Functional Fluorescent Nanosensors for Rapid One-Step Detection of PFAS

Here, the presence of poly- and perfluoroalkyl substances (PFAS) in the environment is associated with adverse health effects but measuring PFAS is challenging due to the associated high cost and technical complexities of the analysis. Here, the reactivity of atomically precise metal-oxo clusters is reported and the foundation for their use is provided as fluorescent nanosensors for PFAS detection. The material comprises crystalline, water soluble, hexanuclear cerium-oxo clusters [Ce 6 (µ 3 -O) 4 (µ 3 -OH) 4 ] 12+ decorated with glycine molecules (Ce-Gly) characterized by fluorescence emission at 353 nm. The Ce-Gly fluorescence is found sensitive to long chain carboxylated PFAS of CF 3 –(CF 2 ) n –, where n ≥ 6, such as perfluorooctanoic, perfluorononanoic and perfluorodecanoic acids. This unique reactivity leads to a change in the emission spectra in a concentration dependent manner, enabling PFAS detection through ligand exchange and aggregation-induced emission (AIE) enhancement. No significant cross-reactivity from potentially co-existing species, including sulfonated PFAS, octanoic and dodecanoic acids, humic acid, and inorganic ions is observed. With an optimal concentration of 3.3 µg mL -1 Ce-Gly, the method demonstrated detection limits of 0.24 ppb for PFOA and 0.4 ppb for PFNA. These findings highlight the potential of fluorescence-based detection strategies utilizing nanoscale probes such as Ce-Gly as fluorescent probes and nanosensors for PFAS.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Striking luminescence phenomena of carbon dots and their applications as a double ratiometric fluorescence probes for H2S detection

Here, we report some new observations on the luminescence of carbon dots (CDs) that are passivated with polyethylene glycol, and explored them, for the first time, as highly sensitive H2S detection probe. The as-prepared CDs have an ultraviolet (UV) emission at 350 nm and a green emission at 540 nm when excited at 270 nm, but they have only a green emission at 523 nm when excited at 365 nm. As Na2S is added to the CDs, the UV emission decreases gradually, while the green emission increases slightly, and interestingly a new emission appears at 455 nm is increased linearly in intensity with the increase of Na2S concentration. The blue emission at 455 nm is from the intrinsic core of CDs, and the green emissions at 540 or 523 nm are from their surface states, while the UV emission at 350 nm is from the anchored PEG. Both the emission intensity ratios of F-450/F-350 and F-455/F-523 show an excellent linear relationship with the Na2S concentration in the range of 0-800 mu M, and the detection limit estimated from both of them is approximately 7.0 nM, indicating our method is the most sensitive H2S CDs based detection method reported thus far. Furthermore, the detection was tested successfully for H2S imaging in live cells. We propose that the interactions of H2S with the CDs and the anchored ligands, as well as the energy transfer between the ligands and the CDs, are responsible for the luminescence responses for H2S detection. Our studies enrich the world of carbon dots with plenty of potential applications. (C) 2020 Elsevier Ltd. All rights reserved.

Bioimaging↗

Ambient ion focusing from a field-free region to a detector: enhanced signal for explosives and drug detection with mass spectrometry

This study demonstrates ion focusing at ambient pressure and increased ion signal by creating a voltage gradient from a field-free region to a detector, thereby improving the detection of chemicals, such as explosives and drugs. At ambient pressure, ion loss and resulting signal reduction pose challenges that limit detection sensitivity in analytical instruments. Techniques to increase sensitivity, such as atmospheric flow tube-mass spectrometry (AFT-MS), extend ion-molecule reaction times but result in significant overall ion loss due to diffusion. Ion manipulation techniques, though challenging at ambient pressure, can mitigate these losses by concentrating ions toward the detector inlet. Using SIMION, ion trajectories were modeled with a voltage gradient applied between a flow tube and a detector, revealing ion focusing at ambient pressure. Experimental verification with an atmospheric flow tube employed both mass spectrometry and Faraday plate detectors to measure ion beam profiles across varying flow rates, tube diameters, and voltage gradients. Application of a voltage gradient effectively directed ions to the axial center of the flow tube, narrowed ion beam width, and increased signal intensity by 5 to 10 times compared to conditions without a voltage gradient. This ion focusing approach shows promise for improving sensitivity in ambient-pressure instruments. This technique has the potential to enhance detection levels in security and forensic applications, with particular benefits for field-portable devices used at checkpoints to identify explosives and drugs.

ambient pressure↗

Emission Spectra of Uranium Particulates at High Temperature

The emission spectrum of micron-scale uranium particulates at high temperatures in the ultraviolet, visible, and near-infrared spectral regions is investigated using a heterogeneous shock tube. Temperatures from 3000 to 9000 K are characterized in an inert argon environment and with incremental amounts of added oxygen. Atomic line spectra do not emerge above the continuum emission spectrum until between 4500 and 5000 K in pure argon, and 6100 and 6600 K in 1% oxygen. For 5% oxygen, however, the threshold for atomic emission drops below 3800 K. Uranium monoxide molecular emission in the strongest visible band at 595.4 nm is not observed at any condition. Uncertainties in particle temperature determination in high-temperature shock tube environments are discussed, and limitations to such measurements are presented, such as those from experimental factors such as the powder loading method and expected detection limits of uranium species in relevant conditions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A New Field Instrument for Leaf Volatiles Reveals an Unexpected Vertical Profile of Isoprenoid Emission Capacities in a Tropical Forest

Both plant physiology and atmospheric chemistry are substantially altered by the emission of volatile isoprenoids (VI), such as isoprene and monoterpenes, from plant leaves. Yet, since gaining scientific attention in the 1950’s, empirical research on leaf VI has been largely confined to laboratory experiments and atmospheric observations. Here, we introduce a new field instrument designed to bridge the scales from leaf to atmosphere, by enabling precision VI detection in real time from plants in their natural ecological setting. With a field campaign in the Brazilian Amazon, we reveal an unexpected distribution of leaf emission capacities (EC) across the vertical axis of the forest canopy, with EC peaking in the mid-canopy instead of the sun-exposed canopy surface, and moderately high emissions occurring in understory specialist species. Compared to the simple interpretation that VI protect leaves from heat stress at the hot canopy surface, our results encourage a more nuanced view of the adaptive role of VI in plants. We infer that forest emissions to the atmosphere depend on the dynamic microenvironments imposed by canopy structure, and not simply on canopy surface conditions. We provide a new emissions inventory from 52 tropical tree species, revealing moderate consistency in EC within taxonomic groups. We highlight priorities in leaf volatiles research that require field-portable detection systems. Our self-contained, portable instrument provides real-time detection and live measurement feedback with precision and detection limits better than 0.5 nmol VI m -2 leaf s -1 . We call the instrument ‘PORCO’ based on the gas detection method: photoionization of organic compounds. We provide a thorough validation of PORCO and demonstrate its capacity to detect ecologically driven variation in leaf emission rates and thus accelerate a nascent field of science: the ecology and ecophysiology of plant volatiles.

54 ENVIRONMENTAL SCIENCES↗

Isotopic analysis of Nd nanoparticles using single particle MC-ICP-MS: A comparative study with single particle-ICP-TOF-MS

Single particle - inductively coupled plasma - mass spectrometry (SP-ICP-MS) is a powerful technique for characterization of the elemental and isotopic composition of individual particles. In this work, the capabilities of the newest generation of MC-ICP-MS with acquisition rates down to 50 ms were evaluated for single particle analysis, with a focus on isotopic precision achievable on a single-particle level. Nd (NdVO 4 ) nanoparticles (~120 nm in diameter) were used as case study and were first characterized in terms of mass (respective size) and particle number concentration by SP-ICP-TOF-MS and then by SP-MC-ICP-MS for isotopic precision. For the isotopic ratio measurements, the MC-ICP-MS performance was compared to the ICP-TOF-MS and it was found that the isotope ratio precision was increased (R 2 between 0.98 and 0.99) compared to ICP-TOF-MS (R 2 between 0.88 and 0.97). The accuracy attained on a single particle level, was compared to bulk digestion followed by MC-ICP-MS analysis, and the SP-MC-ICP-MS technique was able to determine the particle population average to be <4 %, percent relative differences for the 142 Nd/ 144 Nd, 143 Nd/ 144 Nd, 145 Nd/ 144 Nd, 146 Nd/ 144 Nd, and 148 Nd/ 144 Nd ratios The detection limit for the SP-MC-ICP-MS approach was also assessed. Here, when utilizing an all Faraday-cup based detection scheme the determined LOD for the measurements was 0.2fg for Nd, per particle. Based on these results, the newest generation of MC-ICP-MS has demonstrated its utility for performing SP measurement, particularly when high precision isotopic determination is warranted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Atacama Cosmology Telescope: A Search for Planet 9

We use Atacama Cosmology Telescope (ACT) observations at 98 GHz (2015–2019), 150 GHz (2013–2019), and 229 GHz (2017–2019) to perform a blind shift-and-stack search for Planet 9. The search explores distances from 300 au to 2000 au and velocities up to 6farcm3 per year, depending on the distance (r). For a 5 Earth-mass Planet 9 the detection limit varies from 325 au to 625 au, depending on the sky location. For a 10 Earth-mass planet the corresponding range is 425 au to 775 au. The predicted aphelion and most likely location of the planet corresponds to the shallower end of these ranges. The search covers the whole 18,000 square degrees of the ACT survey. No significant detections are found, which is used to place limits on the millimeter-wave flux density of Planet 9 over much of its orbit. Overall we eliminate roughly 17% and 9% of the parameter space for a 5 and 10 Earth-mass Planet 9, respectively. These bounds approach those of a recent INPOP19a ephemeris-based analysis, but do not exceed it. We also provide a list of the 10 strongest candidates from the search for possible follow-up. More generally, we exclude (at 95% confidence) the presence of an unknown solar system object within our survey area brighter than 4–12 mJy (depending on position) at 150 GHz with current distance 300 au < r < 600 au and heliocentric angular velocityy <?CDATA $1\buildrel{\,\prime}\over{.} 5\,{\mathrm{yr}}^{-1}\lt v\cdot \tfrac{500\,\mathrm{au}}{r}\lt 2\buildrel{\prime\prime}\over{.} 3\,{\mathrm{yr}}^{-1}$?> 1 .' 5 yr – 1 < v · 500 au r < 2 ." 3 yr – 1 , corresponding to low-to-moderate eccentricities. These limits worsen gradually beyond 600 au, reaching 5–15 mJy by 1500 au.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct and Sensitive Electrochemical Evaluation of Pramipexole Using Graphitic Carbon Nitride (gCN) Sensor

Pramipexole (PMXL) belongs to the benzothiazole class of aromatic compounds and is used in treating Parkinson’s disease; however, overdosage leads to some abnormal effects that could trigger severe side effects. Therefore, it demands a sensitive analytical tool for trace level detection. In this work, we successfully developed an electrochemical sensor for the trace level detection of PMXL, using the voltammetric method. For the analysis, graphitic carbon nitride (gCN) was opted and synthesized by using a high-temperature thermal condensation method. The synthesized nanoparticles were employed for surface characterization, using transmission electron microscopy (TEM), X-ray diffraction (XRD), and atomic force microscopy (AFM) techniques. The electrochemical characterization of the material was evaluated by using the electrochemical impedance spectroscopy (EIS) technique to evaluate the solution–electrode interface property. The cyclic voltammetry (CV) behavior of PMXL displayed an anodic peak in the forward scan, indicating that PMXL underwent electrooxidation, and an enhanced detection peak with lower detection potential was achieved for gCN-modified carbon paste electrode (gCN·CPE). The influence of different parameters on the electrochemical behavior was analyzed, revealing the diffusion governing the electrode process with an equal number of hydronium ions and electron involvement. For the fabricated gCN·CPE, good linearity range was noticed from 0.05 to 500 µM, and a lower detection limit (L D ) of 0.012 µM was achieved for the selected concentration range (0.5 to 30 µM). Selectivity of the electrode in PMXL detection was investigated by conducting an interference study, while the tablet sample analysis demonstrates the sensitive and real-time application of the electrode. The good recovery values for the analysis illustrate the efficiency of the electrode for PMXL analysis.

36 MATERIALS SCIENCE↗

Label-free nanoscopy of cell metabolism by ultrasensitive reweighted visible stimulated Raman scattering

Nanoscopic imaging of cell metabolism is hindered by the incompatibility of small metabolites with fluorescent dyes and the limited resolution of imaging mass spectrometry. We present ultrasensitive reweighted visible stimulated Raman scattering (URV-SRS), a label-free vibrational nanoscopy technique that enables multiplexed detection of metabolic nanostructures within cells. We developed an extensively chirped spectral focusing visible SRS microscope that achieves a detection limit of 4,000 molecules and introduced a self-supervised learning-based denoiser to robustly suppress non-independent SRS noise by over 7.2 dB. The instrumentation-based signal enhancement and computation-based noise suppression synergistically improved the detection sensitivity by 50 times over near-infrared SRS. Leveraging this enhanced sensitivity, we further pushed the resolution to nanoscopic levels by introducing Fourier reweighting to amplify sub-100 nm spatial frequencies previously overwhelmed by noise. Validated by Fourier ring correlation, URV-SRS achieves a lateral resolution of 86 nm in cellular imaging. Here, we applied URV-SRS to elucidate the reprogramming of metabolic nanostructures associated with virus replication in Vero E6 host cells and to compositionally delineate subcellular fatty acid synthesis in engineered Escherichia coli, demonstrating its capability towards nanoscopic spatial metabolomics.

59 BASIC BIOLOGICAL SCIENCES↗

Parsec-scale Properties of Steep- and Flat-spectrum Extragalactic Radio Sources from a VLBA Survey of a Complete North Polar Cap Sample

We observed with the Very Long Baseline Array (VLBA) at 2.3 and 8.6 GHz a complete flux-density-limited sample of 482 radio sources with decl. > +75° brighter than 200 mJy at 1.4 GHz drawn from the NVSS catalog. A total of 34% of the sources show parsec-scale emission above the flux density detection limit of 30 mJy; their accurate positions and parsec-scale structure parameters are determined. Among all the sources detected at least at the shortest VLBA baselines, the majority, or 72%, have a steep single-dish spectrum. The fraction of the sources with a detectable parsec-scale structure is above 95% among the flat-spectrum objects and close to 25% among the steep-spectrum objects. We identified 82 compact steep-spectrum source candidates, which make up 17% of the sample; most of them are reported for the first time. The compactness and the brightness temperature of the sources in our sample show a positive correlation with single-dish and VLBA spectral indices. All the sources with a significant 8 GHz variability were detected by the VLBA snapshot observations, which independently confirmed their compactness. We demonstrated that 54% of the sources detected by the VLBA at 2.3 GHz in our sample have a steep VLBA spectrum. The compact radio emission of these sources is likely dominated by optically thin jets or mini-lobes, not by an opaque jet core. These results show that future VLBI surveys aimed at searching for new sources with parsec-scale structure should include not only flat-spectrum sources but also steep-spectrum ones in order to reach an acceptable level of completeness.

47 OTHER INSTRUMENTATION↗

2D Graphene Sheets as a Sensing Material for the Electroanalysis of Zileuton

Zileuton (ZLT) is an active oral inhibitor of enzyme 5-lipoxygenase, and long-term intake and overdose of ZLT cause adverse effects, leading to critical conditions in patients. This is a well-recognized issue that necessitates a better approach for ZLT sensing. Given the increasing interest in ZLT sensing and the limitations of previous techniques, there is a need for a highly sensitive, robust, and fast operation method that is inexpensive and easy to use. Thus, for the sensitive detection and determination of ZLT, an electrochemical sensor based on graphene was fabricated. Graphene has excellent properties, such as high surface area, low toxicity, conductivity, and electroactive conjugation with biomolecules, making it suitable for sensing. The electrocatalytic property of graphene promotes the redox-coupled reaction of ZLT. Electrochemical investigation of the modifier was carried out by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). An optimization and analysis of the influence of different parameters on the electrochemical behavior of ZLT were carried out using the CV approach. The scan rate study aided in exploring the physicochemical properties of the electrode process, and two electrons with two protons were found to be involved in the electrooxidation of ZLT. The fabricated sensor showed a wide range of linearity with ZLT, from 0.3 µM to 100.0 µM, and the detection limit was evaluated as 0.03 µM under optimized conditions. The analysis of spiked urine samples, with good recovery values for percent RSD, provided support for the efficiency and applicability of the developed electrode.

2D Material↗

Spectral Induced Polarization-Biogeochemical Relationships for Remediation Amendment Monitoring

Geophysical tools such as electrical resistivity (ER) can indirectly monitor subsurface changes in response to remedial injections. These methods exhibit relatively low spatial resolution compared to sediment core characterization but are advantageous due to the ability to collect measurements non-intrusively over time across large volumes of the subsurface. Moreover, along with confirmatory groundwater or core sampling, geophysical methods can be used during active biogeochemical remedies to monitor short-term contaminant transformations and mobility, as well as part of an overall strategy for long-term monitoring of subsurface contaminated sites. The use of alternating current spectral induced polarization (SIP) provides significantly more information than conventional geophysical methods like direct current ER. SIP allows for monitoring changes in both solution and surface conductivity by separation of real and imaginary conductivity, respectively, as well as surface capacitance. In principle, SIP can measure indicators of remedy progression such as precipitation reactions that sequester contaminants, potentially providing a better indication of amendment delivery and reactivity as compared to conventional ER methods. However, multiple processes and material properties have overlapping (interacting) electrical responses across a range of frequencies. Hence, the purpose of this scoping study was to evaluate if SIP can be used to monitor (a) amendment delivery and (b) precipitation and reactivity of amendments under consideration at Hanford. SIP measurements were collected in fully saturated columns packed with sand and Hanford formation sediments containing (a) amendments that were highly conductive with significant capacitance (zero valent iron – ZVI, sulfur modified iron – SMI) and (b) amendments that exhibited low electrical conductivity with a small capacitance (calcite, apatite, bismuth). The sand was a quartz material with homogenous particle size that exhibited a relatively low surface conductivity. It was used as a control for comparison with the sediments from the Hanford Site, which have a greater surface conductivity because of their complex mineralogy and heterogeneous particle size distribution and may have complex interactions with amendments. The amendment mass fraction was varied to represent the different stages and subsurface locations associated with the delivery of a remedy. The primary objective was to identify the solution and solid surface changes associated with the delivery amendments and their secondary reactions within the subsurface. The figure below summarizes results for the amendments tested through this project. The SIP phase shift or imaginary conductivity change for the high conductivity amendments was more than 10 times that of the low conductivity amendments, highlighting the relative ease of detection of ZVI and SMI independent of the background signal from sand or Hanford sediments. The ZVI phase shift and imaginary conductivity changes occur primarily at high frequency (> 100 Hz) whereas SMI changes were at low frequency (0.01 to 10 Hz). SIP signals of SMI also increased over time and the maximum shifted to lower frequencies. The low conductivity amendments (calcite, abiotic and biotic apatite, bismuth subnitrate) exhibited relatively small phase and imaginary conductivity changes when added to sediments. The changes were above minimum detection limits (0.5 mrad for phase shift, 0.03 µS/cm for imaginary conductivity) for the highest concentration except for the commercial bismuth material. The lowest amendment concentration that can be detected is likely sediment specific, as minerals in sediments (clays, magnetite, Fe-oxides) have some capacitance and, therefore, exhibit a variable phase shift.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Diagnostic Evaluation of the IS1081-Targeted Real-Time PCR for Detection of Mycobacterium bovis DNA in Bovine Milk Samples

The ability of Mycobacterium bovis (M. bovis) to survive in bovine milk has emerged as a serious public health concern. The first objective of this study was to evaluate the diagnostic utility of IS1081-targeted real-time PCR for the detection of M. bovis DNA in different fractions of bovine milk. In a model study, bovine milk samples were spiked with serially diluted M. bovis BCG to investigate the detection limit of M. bovis DNA in whole milk and milk fractions (cream, pellet, and pellet + cream combined) using IS1081 real-time PCR. The assay was then used to detect M. bovis DNA in whole milk and milk fractions from naturally infected animals. The results showed that the IS1081 real-time PCR was more sensitive when detecting M. bovis DNA in the cream layer alone and cream + pellet combined compared to whole milk or the pellet alone. While PCR-based diagnostic assays for the detection of M. bovis in milk samples provide a quicker diagnostic tool for bovine tuberculosis, safe processing, and handling of M. bovis-infected milk samples remain a challenge and pose a human health risk. PrimeStore Molecular Transport Medium (MTM) has been shown to rapidly inactivate infected specimens while preserving nucleic acid for subsequent Molecular analysis. Therefore, the secondary objective of this study was to evaluate the ability of MTM to inactivate M. bovis BCG in spiked milk samples as well as its ability to preserve BCG DNA for the PCR assay. The results showed that MTM can successfully inactivate BCG alone or in spiked milk samples while preserving DNA for the PCR assay. The CT values of M. bovis BCG alone and spiked milk samples aliquoted in MTM and without MTM were similar at various dilutions. Taken together, our results indicate that using DNA extracted from the milk cream fraction alone or combined milk cream and pellet improved the recovery rate of M. bovis DNA in bovine milk samples. MTM has the potential to provide a safe and rapid sample processing tool for M. bovis inactivation in milk samples and preserve DNA for molecular diagnostics.

59 BASIC BIOLOGICAL SCIENCES↗

Forward Modeling the Orbits of Companions to Pulsating Stars from Their Light Travel Time Variations

Mutual gravitation between a pulsating star and an orbital companion leads to a time-dependent variation in path length for starlight traveling to Earth. These variations can be used for coherently pulsating stars, such as the δ Scuti variables, to constrain the masses and orbits of their companions. Observing these variations for δ Scuti stars has previously relied on subdividing the light curve and measuring the average pulsation phase in equally sized subdivisions, which leads to undersampling near periapsis. We introduce a new approach that simultaneously forward models each sample in the light curve and show that this method improves upon current sensitivity limits—especially in the case of highly eccentric and short-period binaries. We find that this approach is sensitive enough to observe Jupiter mass planets around δ Scuti stars under ideal conditions, and use gravity-mode pulsations in the subdwarf B star KIC 7668647 to detect its companion without radial velocity data. We further provide robust detection limits as a function of the signal-to-noise ratio of the pulsation mode and determine that the minimum detectable light travel time amplitude for a typical Kepler δ Scuti is around 2 s. This new method significantly enhances the application of light travel time variations to detecting short-period binaries with pulsating components, and pulsating A-type exoplanet host stars, especially as a tool for eliminating false positives.

79 ASTRONOMY AND ASTROPHYSICS↗