Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid hydrogen”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Performance Gains of Propellant Management Devices for Liquid Hydrogen Depots

This paper presents background, experimental design, and preliminary experimental results for the liquid hydrogen bubble point tests conducted at the Cryogenic Components Cell 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. The purpose of the test series was to investigate the parameters that affect liquid acquisition device (LAD) performance in a liquid hydrogen (LH2) propellant tank, to mitigate risk in the final design of the LAD for the Cryogenic Propellant Storage and Transfer Technology Demonstration Mission, and to provide insight into optimal LAD operation for future LH2 depots. Preliminary test results show an increase in performance and screen retention over the low reference LH2 bubble point value for a 325 2300 screen in three separate ways, thus improving fundamental LH2 LAD performance. By using a finer mesh screen, operating at a colder liquid temperature, and pressurizing with a noncondensible pressurant gas, a significant increase in margin is achieved in bubble point pressure for LH2 screen channel LADs.

Hartwig, Jason W.↗

Flow Visualization of Liquid Hydrogen Line Chilldown Tests

We present experimental measurements of wall and fluid temperature during chill-down tests of a warm cryogenic line with liquid hydrogen. Synchronized video and fluid temperature measurements are used to interpret stream temperature profiles versus time. When cold liquid hydrogen starts to flow into the warm line, a sequence of flow regimes, spanning from all-vapor at the outset to bubbly with continuum liquid at the end can be observed at a location far downstream of the cold inlet. In this paper we propose interpretations to the observed flow regimes and fluid temperature histories for two chilldown methods, viz. trickle (i.e. continuous) flow and pulse flow. Calculations of heat flux from the wall to the fluid versus wall temperature indicate the presence of the transition/nucleate boiling regimes only. The present tests, run at typical Reynolds numbers of approx O(10 (exp 5)), are in sharp contrast to similar tests conducted at lower Reynolds numbers where a well-defined film boiling region is observed.

Line chill down↗

Integrated Refrigeration and Storage for Advanced Liquid Hydrogen Operations

NASA has used liquefied hydrogen (LH2) on a large scale since the beginning of the space program as fuel for the Centaur and Apollo upper stages, and more recently to feed the three space shuttle main engines. The LH2 systems currently in place at the Kennedy Space Center (KSC) launch pads are aging and inefficient compared to the state-of-the-art. Therefore, the need exists to explore advanced technologies and operations that can drive commodity costs down, and provide increased capabilities. The Ground Operations Demonstration Unit for Liquid Hydrogen (GODU-LH2) was developed at KSC to pursue these goals by demonstrating active thermal control of the propellant state by direct removal of heat using a cryocooler. The project has multiple objectives including zero loss storage and transfer, liquefaction of gaseous hydrogen, and densification of liquid hydrogen. The key technology challenge was efficiently integrating the cryogenic refrigerator into the LH2 storage tank. A Linde LR1620 Brayton cycle refrigerator is used to produce up to 900W cooling at 20K, circulating approximately 22 g/s gaseous helium through the hydrogen via approximately 300 m of heat exchanger tubing. The GODU-LH2 system is fully operational, and is currently under test. This paper will discuss the design features of the refrigerator and storage system, as well as the current test results.

Liquefaction↗

Helium Conservation by Diffusion Limited Purging of Liquid Hydrogen Tanks

Recently, the new 1.2-million-gallon liquid hydrogen (LH 2 ) storage tank at the Kennedy Space Center Launch Complex 39 was purged, replacing nitrogen with helium, using a piston purge process. This purging approach had been used on Space Shuttle External Tanks (ET) in the past, but not on one of the large LH 2 tanks. The result was a huge success, potentially saving more than 1 million cubic feet of helium and significant labor. To better understand this result, a diffusion-based purge model was developed. The model predictions accurately match the helium concentration data, providing understanding of the helium savings and suggesting how to better optimize the purging of this large tank for future operations. The model was then applied to the piston purging of the Space Shuttle ETs, showing that these purges were not optimal, but that the amount of wasted helium was not excessive and that additional helium might have been saved by small changes to the process. The Space Shuttle Program (SSP) has ended, but these results are applicable to the purging of future large cylindrical LH 2 tanks. Finally, data have been obtained on inerting the Space Launch System (SLS) Core Stage (CS) LH 2 tank, replacing hydrogen with helium after an aborted launch. This is a more complicated case, but the model predicts that substantial helium might be saved by modifying the current purging process.

Helium Conservation↗

Glass Bubbles Insulation for Liquid Hydrogen Storage Tanks

A full-scale field application of glass bubbles insulation has been demonstrated in a 218,000 L liquid hydrogen storage tank. This work is the evolution of extensive materials testing, laboratory scale testing, and system studies leading to the use of glass bubbles insulation as a cost efficient and high performance alternative in cryogenic storage tanks of any size. The tank utilized is part of a rocket propulsion test complex at the NASA Stennis Space Center and is a 1960's vintage spherical double wall tank with an evacuated annulus. The original perlite that was removed from the annulus was in pristine condition and showed no signs of deterioration or compaction. Test results show a significant reduction in liquid hydrogen boiloff when compared to recent baseline data prior to removal of the perlite insulation. The data also validates the previous laboratory scale testing (1000 L) and full-scale numerical modeling (3,200,000 L) of boiloff in spherical cryogenic storage tanks. The performance of the tank will continue to be monitored during operation of the tank over the coming years.

Glass bubble↗

Integrated gasifier combined cycle polygeneration system to produce liquid hydrogen

An integrated gasifier combined cycle (IGCC) system which simultaneously produces electricity, process steam, and liquid hydrogen was evaluated and compared to IGCC systems which cogenerate electricity and process steam. A number of IGCC plants, all employing a 15 MWe has turbine and producing from 0 to 20 tons per day of liquid hydrogen and from 0 to 20 MWt of process steam were considered. The annual revenue required to own and operate such plants was estimated to be significantly lower than the potential market value of the products. The results indicate a significant potential economic benefit to configuring IGCC systems to produce a clean fuel in addition to electricity and process steam in relatively small industrial applications.

Burns, R. K.↗

Liquid hydrogen turbopump foil bearing

Space transfer vehicles and other power and propulsion systems require long-life turbopumps. Rolling element bearings used in current turbopumps do not have sufficient life for these applications. Process fluid foil bearings have established long life, with exceptional reliability, over a wide range of temperatures and fluids in many high-speed turbomachinery applications. However, liquid hydrogen turbopumps require high-load capacity bearings. An experimental study was conducted to measure foil journal bearing load capacity in liquid hydrogen, using a bearing designed specifically for cryogenic hydrogen turbopump applications. Additional performance parameters such as power loss, stability, cooling flow requirements, and bearing life were measured. These tests showed a load capacity safety factor of approximately 10 for liquid hydrogen turbopump applictions. These tests also demonstrated good rotor stability, low power loss and cooling flow, and long life.

Saville, M.↗