Accelerated Aging Humidity Chamber for Nuclear Grade HEPA Filter Media

A unique accelerated aging humidity chamber for simulating the natural aging process of nuclear grade high efficiency particulate air (HEPA) filter media is being designed, implemented, and tested. The nuclear industry currently lacks information regarding the shelf life and service life of HEPA filter media. The Department of Energy recommends disposing of HEPA filters 10 years after the manufacture date for filters operated under dry conditions. Studies have shown the tensile strength and water repellency of HEPA filter media diminish with age. The chamber's principal function is to sustain an elevated relative humidity condition for an extended duration specified by the Arrhenius aging model. To accomplish this, various design parameters were established: (1) consistently achieve uniform humidity conditions within the chamber to equally expose media sheets, (2) ensure the chamber is sufficiently sealed to mitigate the uncontrolled infiltration of air, (3) confidently secure the media sheets to avert the introduction of unnecessary stressing/creasing, (4) fabricate the chamber from clear polycarbonate material to allow inspection of the media sheets, (5) provide a safe and ergonomic design for personnel, (6) ensure the chamber design is replicable and relatively easy to fabricate/assemble. A humidity source, fan, PID controller, humidity and temperature transmitters, and data loggers are required for proper operation and control of the chamber. The humidity source must accommodate target values up to 95% relative humidity throughout the chamber. The three humidity and temperature transmitters are strategically spaced throughout the chamber to ensure uniform conditions. The 10 cubic feet per minute (CFM) fan selected intends to accomplish the desired air change rate inside the chamber of approximately 20 air changes per hour (ACH). The 2 plenums on the upper and lower portions of the chamber utilize a perforated design to uniformly distribute air, promote air mixing, and control the air velocity entering the chamber. Industrial blueprint hanging clamps are being retrofitted to be seated within the chamber drawers and firmly secure the nuclear grade filter media. The aged media will be evaluated using autopsy methodology, and the results obtained intend to help clarify the useful life of nuclear grade HEPA filters. Nuclear grade high efficiency particulate air (HEPA) filters are defined as disposable, extended-media, dry-type filters with a rigid casing enclosing the full depth of the pleats and have a minimum particle removal efficiency of 99.97%. [1] - HEPA filters are constantly exposed to stressors and subsequently have been shown to degrade as the filter ages. Properties such as tensile strength and water repellency, along with others, are negatively impacted. [2] - Due to the scarcity of naturally aged HEPA filters available, it is crucial to develop accelerated aging methods which effectively mimic the natural degradation effects. - After accelerated aging, the filters are subject to testing in the Axial Flow Large Scale Test Stand (ALSTS) and other analysis techniques such as the same qualification tests performed directly after being manufactured. - Quality data is necessary for future decisions regarding the lifetime of nuclear grade HEPA filters. - The objective is to develop a prototype accelerated aging humidity chamber for nuclear grade HEPA filter media. The chamber should expose the media to commonly occurring stressors to expedite the degradation process caused by aging. PID yields reliable and reproducible results: - CFD model correlates well with actual performance; - Further analysis is needed to complete characterization; - Future work for the chamber is still to be completed. The data shown in Figure 5 and Table 1 indicate the system is functioning as designed. As can be determined from the system response evaluation in Table 1, the PID controller is yielding reliable and reproducible results at each set point. As the set point increases, the time constant and 20% settling time increase accordingly. From the results in Table 1, it stands to reason that the CFD model correlates well with the actual performance of the system. Each system response parameter for the 90%RH* CFD model is slightly lower than the parameters collected from the physical model tested at an equivalent set point. This is to be expected considering the inlet in the CFD model is a constant supply of water vapor, whereas the physical model uses a PID controller to monitor the amount of water vapor needed and reacts accordingly. More analysis is still to be done on the prototype chamber. A pressure test will be conducted in order to determine the hourly leak rate of the chamber. This test will involve constant air flow into the chamber until the desired pressure is reached. A uniformity test will also be conducted in order to ensure each filter medium is being exposed to equivalent relative humidity levels. This test will involve an array of humidity meters strategically oriented inside the chamber to record any possible gradients. Future work for the chamber includes dehumidification abilities, tests while fully loaded with filters, and temperature control. Once completed, the autopsy team at Institute of Clean Energy Technology will conduct necessary accelerated aging studies as needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of different fuel design options with SiC cladding for light water reactors

It is very important to avoid high tensile stresses in SiC if it is to be used safely as the cladding material in LWRs. To achieve this goal, three fuel design options are examined here: fuel pellets with a 10% vol central void, adding 10% vol BeO in UO{sub 2} fuel and replacing the gas gap with Lead-Bismuth Eutectic (LBE) bond. For each case, a neutronic analysis is first applied using CASMO-4E to obtain the required enrichment to achieve a fuel average burnup of 50 MWd/kgU. The fuel performance code FRAPCON, specifically FRAPCON-3.3 and FRAPCON-EP, is modified and then used to simulate the effects of steady-state irradiation in each case for typical PWR peak rod conditions. Key parameters like fuel average temperature and plenum pressure are examined for the relative performance of each approach. The results show that all three options can improve the fuel performance by lowering the fuel temperature as well as the plenum pressure. Fuel pellets with a central void design offers the most advantages since the larger void volume in the fuel rod results in the lowest plenum pressure, which is the limiting condition for safe operation of the SiC cladding. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Propane vehicles : status, challenges, and opportunities.

Propane as an auto fuel has a high octane value and has key properties required for spark-ignited internal combustion engines. To operate a vehicle on propane as either a dedicated fuel or bi-fuel (i.e., switching between gasoline and propane) vehicle, only a few modifications must be made to the engine. Until recently propane vehicles have commonly used a vapor pressure system that was somewhat similar to a carburetion system, wherein the propane would be vaporized and mixed with combustion air in the intake plenum of the engine. This leads to lower efficiency as more air, rather than fuel, is inducted into the cylinder for combustion (Myers 2009). A newer liquid injection system has become available that injects propane directly into the cylinder, resulting in no mixing penalty because air is not diluted with the gaseous fuel in the intake manifold. Use of a direct propane injection system will improve engine efficiency (Gupta 2009). Other systems include the sequential multi-port fuel injection system and a bi-fuel 'hybrid' sequential propane injection system. Carbureted systems remain in use but mostly for non-road applications. In the United States a closed-loop system is used in after-market conversions. This system incorporates an electronic sensor that provides constant feedback to the fuel controller to allow it to measure precisely the proper air/fuel ratio. A complete conversion system includes a fuel controller, pressure regulator valves, fuel injectors, electronics, fuel tank, and software. A slight power loss is expected in conversion to a vapor pressure system, but power can still be optimized with vehicle modifications of such items as the air/fuel mixture and compression ratios. Cold start issues are eliminated for vapor pressure systems since the air/fuel mixture is gaseous. In light-duty propane vehicles, the fuel tank is typically mounted in the trunk; for medium- and heavy-duty vans and trucks, the tank is located under the body of the vehicle. Propane tanks add weight to a vehicle and can slightly increase the consumption of fuel. On a gallon-to-gallon basis, the energy content of propane is 73% that of gasoline, thus requiring more propane fuel to travel an equivalent distance, even in an optimized engine (EERE 2009b).

02 PETROLEUM↗

Protection of extreme ultraviolet lithography masks. II. Showerhead flow mitigation of nanoscale particulate contamination [Protection of EUV lithography masks II: Showerhead flow mitigation of nanoscale particulate contamination]

An analysis is presented of a method to protect the reticle (mask) in an extreme ultraviolet (EUV) mask inspection tool using a showerhead plenum to provide a continuous flow of clean gas over the surface of a reticle. The reticle is suspended in an inverted fashion (face down) within a stage/holder that moves back and forth over the showerhead plenum as the reticle is inspected. It is essential that no particles of 10-nm diameter or larger be deposited on the reticle during inspection. Particles can originate from multiple sources in the system, and mask protection from each source is explicitly analyzed. The showerhead plate has an internal plenum with a solid conical wall isolating the aperture. The upper and lower surfaces of the plate are thin flat sheets of porous-metal material. These porous sheets form the top and bottom showerheads that supply the region between the showerhead plate and the reticle and the region between the conical aperture and the Optics Zone box with continuous flows of clean gas. The model studies show that the top showerhead provides robust reticle protection from particles of 10-nm diameter or larger originating from the Reticle Zone and from plenum surfaces contaminated by exposure to the Reticle Zone. Protection is achieved with negligible effect on EUV transmission. Furthermore, the bottom showerhead efficiently protects the reticle from nanoscale particles originating from the Optics Zone.

36 MATERIALS SCIENCE↗

Spectral Analysis of LDV Measurements inside of the TAMU Air-Cooled Reactor Cavity Cooling System - 18688

Spectral analysis was applied to the LDV measurements inside of the TAMU air-cooled RCCS facility at two different locations to both evaluate the feasibility of spectral methods for this experiment and gain a first insight into the flow behavior using a Fourier representation. Application of the wavelet transform showed that there are patterns in the flow signified by repeating frequencies and flow structures. Although the sampling rate of 7.92 Hz at the data point centered at the bottom center of riser 4 was lower than the higher frequency sampling rate of 57.92 Hz at the top data point of the upper plenum, the wavelet transforms of the higher frequency data point showed that the dominant frequencies were bounded within 4 Hz. Application of wavelet analysis is limited by the size of the interrogation window but may be modified according to the frequency range of interest by adjusting the size of the time width for the undilated Morlet mother wavelet. Spectral analysis can be applied to future experiments to understand uncharacterized flow behavior such as flow reversal inside of the upper plenum and for benchmarking future CFD simulations. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Examination of entrainment, combustibility, and heat transfer due to cell venting inside simplified battery energy storage enclosures

Battery energy storage systems (ESS) assembled of modules containing lithium-ion batteries can pose fire and explosion hazards during thermal runaway because vented gases may accumulate, combust, or escape enclosures. Here, we propose a prototypical configuration composed of the main components of an ESS rack, where modules are represented as rectangles within an enclosure and vent gas is injected steadily through the top of a module. This idealized geometry allows for exploration of how rack-level characteristics can influence smaller single-cell or module-level scales. Through this geometry, we conduct numerical simulations to understand how variations in the vent velocity, temperature, and vertical location affect entrainment rates, fraction of uncombusted fuel, rich-gas coverage, and heat flux to other modules. At lower vent velocities and vertical positions, buoyancy drives enough entrainment and mixing to react with most of the vent gases on the converging plenum. As jet momentum increases and/or buoyancy decreases via higher vent position in the rack, vent gases can propagate into and burn in the divergence plenum. Heat flux to the impinged module scales strongly with vent momentum and temperature, while heat transfer to upper modules peaks when flames in the diverging plenum reach the surface and declines when combustion is suppressed.

Computational fluid dynamics↗

3D CFD Model Validation Using Benchmark Data of 1/16th Scaled VHTR Upper Plenum and Development of Wall Heat-Transfer Correlation For Laminar Flow

With support from the U.S. Department of Energy-Office of Nuclear Energy’s (DOE-NE’s) Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, an effort has been pursued to support high-temperature gas-cooled reactor (HTGR) technology development and its modeling and simulation needs. There is a particular need for advanced modeling and simulation tools to predict thermal-fluid behavior in the nuclear reactor primary system, especially in the core and the lower and upper plena, during safety-related transients. In this report, two main such activities are presented relevant to the HTGRs: (1) three-dimensional (3D) computational fluid dynamics (CFD) validation using benchmark data from the upper plenum of Texas A&M University’s 1/16th scaled very-high-temperature gas-cooled reactor (VHTR), and (2) development of wall heat-transfer correlation for laminar flow in a wall-heated pipe. The CFD tool validation exercises can be helpful to choose the models and CFD tools to simulate and design specific components of the HTRGs such as upper plenum where jet mixing is a complex phenomenon. In a loss of forced circulation event, the laminar flow can be observed during the development of natural circulation flow. This work includes the development and validation of heat transfer correlations for laminar flow using the Nek5000 CFD code due to limited available experimental data for laminar flow conditions to guide low-order models (1D). In this report, the flow characteristics of a single isothermal jet discharging into the upper plenum was investigated using the Nek5000 Large-Eddy Simulation (LES) CFD tool. Several numerical simulations were performed for various jet-discharged Reynolds numbers ranging from 3,413 to 12,819. A grid-independent study was performed. The numerical results of mean velocity, root-mean-square fluctuating velocity, and Reynolds stress were compared against the benchmark data. Good agreement was obtained between simulated and measured data for axial mean velocities, except near the upper plenum hemisphere. The maximum predicted errors for axial mean velocities at various normalized coolant channel diameter heights of 1, 5, and 10 are 1.56%, 1.88%, and 3.82%, respectively. In addition, the predicted root-mean-square fluctuating velocity and Reynolds stress are qualitatively in agreement with the experimental data. The Nek5000 code was used to develop wall-heat transfer correlation for laminar flow in a cylindrical tube. Several simulations were performed for various Reynolds flow and wall-heat fluxes. A new heat transfer correlation was developed using data from Nek5000 simulation results and regression functions in Matlab. The developed heat transfer correlation is valid for various Reynolds flows from 200 to 2000. The predicted R² value for model fit was 0.875, which ensures that 87.5% of the model data lies on the Nek5000 data. Moreover, a machine learning (ML) tool was used to train and test the Nek5000 data. A good fit of the ML-based model was observed with the test data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

THREE-DIMENSIONAL THERMAL MODELING ANALYSIS OF CST MEDIA FOR THE SMALL ION EXCHANGE PROJECT

The Small Column Ion Exchange (SCIX) project is designed to accelerate closure of High Level Waste (HLW) tanks at the Savannah River Site (SRS). The SRS tanks store HLW in three forms: sludge, saltcake, and supernate. An in-tank ion exchange process is being designed to treat supernate and dissolved saltcake waste. Through this process, radioactive cesium from the salt solution is adsorbed into Crystalline Silicotitanate (CST) ion exchange media packed within a flow-through column. A packed column loaded with radioactive cesium generates significant heat from radiolytic decay. The waste supernate solution within the ion exchange bed will boil around 120 C. Solution superheating above the boiling point within the column could lead to violent hazardous energy releases. System heating from loaded CST is also of concern in other process modules, such as the waste tank. Due to tank structural integrity concerns, the wall temperature limit for the SRS waste tanks is 100 C. The transfer of cesium-loaded CST to the tank could result in localized hot spots on the tank floor and walls which may exceed this limit. As a result, thermal modeling calculations have been conducted to predict the maximum temperatures achievable both in the column and in the waste tank. As specified in the associated Technical Task Plan, one objective of the present work was to compute temperature distributions within the ion exchange column module under accident scenarios including loss of salt solution flow through the bed and loss of coolant system flow. The column modeling domain and the scope of the calculations in this case were broadened relative to previous two-dimensional calculations to include vertical temperature distributions within the packed bed of ion exchange media as well as the upper column plenum region containing only fluid. The baseline design conditions and in-column modeling domain for the ion-exchange column module are shown in Figure 1. These evaluations assumed the maximum bounding cesium loading considered possible based on current knowledge regarding CST media and the anticipated feed compositions. Since this cesium loading was considerably higher than the nominal loading conditions in SRS waste, cases with lower loading were also evaluated. Modeling parameters were the same as those used previously unless otherwise indicated. The current model does not capture multi-phase cooling mechanisms operative when solution boiling occurs. This feature is conservative in the sense that it does not account for the large cooling effects associated with phase transfer. However, the potential transfer of heat to the plenum region associated with vertical bubble ascension through the column during boiling is also neglected. Thermal modeling calculations were also performed for the entire waste storage tank for the case where loaded and ground CST was transferred to the tank. The modeling domain used for the in-tank calculations is provided in Figure 2. The in-tank domain is based on SRS Tank 41, which is a Type-IIIA tank. Temperature distributions were evaluated for cylindrical, ground CST mounds located on the tank floor. Media grinding is required prior to vitrification processing of the CST in the SRS Defense Waste Processing Facility (DWPF). The location of the heat source region on the tank floor due to the accumulation of CST material was assumed to be just under the grinder. The shape of the CST mound was assumed to be cylindrical. This shape is believed to be most representative of the actual mound shape formed in the tank, given that submersible mixing pumps will be available for media dispersion. Alternative configurations involving other geometrical shapes for the CST mound were evaluated in the previous work. Sensitivity analysis for the in-tank region was performed for different amounts of CST media. As was the case for the in-column model, the in-tank model does not include multi-phase cooling mechanisms operative when solution boiling occurs. The in-column and the in-tank evaluations incorporated recently updated maximum cesium loading levels calculated using the current SCIX feed compositions, which resulted in significantly higher cesium loading than previously calculated. The calculations were conducted to ensure conservative predictions for the maximum temperatures achievable using the current baseline design. The degree of conservatism was reduced for in-column calculations relative to the previous work by using a three-dimensional modeling approach and selecting parameters which were nearer to expected conditions. The degree of conservatism for the in-tank calculations was also reduced by lowering the soil penetration depth below the tank from 150 to 20 feet. The primary goals of the extended thermal modeling effort were to determine whether fluid boiling or superheating are possible within the column module and to determine the maximum floor temperatures within the tank loaded with spent CST.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

X-ray and gamma-ray tomographic imaging of fuel relocation inside sodium fast reactor test assemblies during severe accidents

The present work reports on x-ray and gamma-ray high-spatial resolution computerized tomography measurements of the Pin Bundle Metallic Fuel Relocation (PBR) assemblies tested in the Metallic Uranium Safety Experiment (MUSE) facility at Argonne National Lab (ANL). The aim of the study was to characterize fuel relocation structures that develop during severe core accidents pertaining to SFR assemblies; these include but are not limited to advanced core disruption recreated in the PBR-1 assembly, and cladding breach recreated in the PBR-2 assembly. We report the x-ray tomography measurements were able to resolve small quantities of relocation fuel; with increased presence of relocation fuel, the x-ray 1measurements spatially mapped the material but could not resolve the inner regions of these. The gamma-tomography measurements showed improved results, resolving the relocation structures in great detail. The upper plenum of the PBR-1 assembly where the molten uranium was initially inserted presented high structural damage, reflected by the partial and complete disintegration of the central rods. Relocation fuel filled the subchannels, adhering to surviving cladding walls and the assembly casing. In the lower portion of the measured section, the tomogram degrades due to photon starvation effects hinting at the increased amount of relocation fuel potentially plugging the assembly; flow blockage in this section was difficult to determine due to the tomogram’s degradation from photon starvation. Small fragments were observed further down the assembly, dislodged from the initial insertion of the molten material. This section was used as an unperturbed assembly reference, with a calculated blockage of less than 1% from the present fragments. The PBR-2 assembly was characterized by columnar relocation structures propagating through the subchannels. Three of the relocation structures were captured in the measured section, with evidence of cross migration on to adjacent subchannels. The measured section in this assembly captures the leading edge of two structures. The calculated flow blockage was 16% in the planes where the three relocation structures are present, but this quickly decreases to approximately 5% past the leading edge of two of the structures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Transient behavior of a supersonic three-dimensional micronozzle with an intersecting capillary

An analysis of the interaction between a pulsed, supersonic microjet and an intersecting gas-filled capillary is presented, which enables a direct measurement of the pressure evolution inside the nozzle of the microjet. Plasma-emission spectroscopy was used to resolve, on a sub-microsecond timescale, the build-up and decay of pressure in the nozzle, which are shown to be correlated to the volume of the plenum supplying the nozzle and to the nozzle-throat size, respectively. The microjet, which was integrated with a capillary-discharge waveguide in a sapphire structure, was used to create a small, tunable region of high density gas within a centimeter-scale plateau of lower-density for use in a laser-plasma accelerator. The resultant longitudinally structured gas-density profile has been used to provide control of electron trapping and acceleration, but its evolution has not previously been directly quantified. Overall, the results presented here pave the way for improved control of laser-plasma accelerators and are also relevant to applications such as miniature satellites and lab-on-a-chip where precise knowledge of microjet pressure evolution is critical.

47 OTHER INSTRUMENTATION↗

Implementing Fuel Cladding Bonding and Assessing its Impact on Axial Gas Communication

Fuel rods irradiated in light-water reactors to burnup values above 45 MWd/kgU are subject to the formation of a chemical and mechanical bond between the fuel and cladding upon gap closure. The formation of the bond subsequently inhibits the ability of fission gases released from the fuel to flow freely to the plenum of the rod. The flowing of gases within fuel rods is referred to as axial gas communication. During transients, such as loss of coolant accidents, the bond may influence cladding deformation prior to breaking. Upon bond breakage, gases are able to more freely communicate to the lower pressure regions of the rod. The impact of bonding on gas communication and the ballooning behavior of the cladding during a loss of coolant accident is of interest to the nuclear industry in support of burnup extension for the existing light-water reactor fleet. In this report, a model to capture the effects of fuel cladding bonding in the BISON fuel performance code is presented. The theory of the model along with implementation testing is provided. A summary of a previously developed axial gas communication is given to set the stage for how the two models may be coupled together. A full-length pressurized-water reactor fuel rod demonstration is highlighted to evaluate the impact of including bonding on axial gas communication calculations using a preliminary coupling methodology. An overview of the next steps regarding the modeling of bonding, axial gas communication, and a more tightly coupled framework is also provided.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sodium Pumping via Condensation within a Non-Wetting Porous Structure

The sodium thermal electrochemical converter (Na-TEC) is a heat engine that generates electricity via the isothermal expansion of sodium ions through a beta”-alumina solid-electrolyte. The transfer of liquid sodium from a low-pressure condenser to a high-pressure evaporator is necessary to complete the thermodynamic cycle for this conversion process. A unique sodium capillary pump for the Na-TEC is proposed, whereby low-pressure sodium vapor is condensed within a non-wetting (i.e. contact angle > 90o) stainless steel porous structure. Due to the curvature of the non-wetting liquid-vapor interface, the liquid adjacent to the interface is at a higher pressure than the vapor. This is in contrast to traditional wicks, where the liquid adjacent to the interface has a lower pressure. Thus, the curvature created at this non-wetting condensation interface supplies a directed force upon the liquid sodium that effectively “pushes” it towards a high pressure region, whereas a traditional capillary wick “pulls” the liquid. Porous structures made of stainless steel 316 are commercially available, and this material is non-wetting to sodium at the relevant temperature range of the Na-TEC condenser (500K – 673K). An experimental set-up is used to measure several interfacial and transport properties of the condensed sodium within this porous structure. These properties include the temperature dependent Laplace pressure generated at the phase change interface and the permeability of the porous structure. Liquid sodium is in contact with the porous structure and is progressively pressurized with argon gas until the sodium “breaks through” and the liquid begins to flow. This break-through pressure is determined when electrical contact is established between the flowing liquid metal and a set of electrodes cemented along the flow path. The velocity of the flowing sodium can also be measured with these electrodes, and the permeability is then determined by fitting velocity data to the classical Darcy law. These interfacial properties are then applied to a conjugate heat transfer model, which treats the coupled momentum and thermal transport processes within the non-wetting porous structure as sodium vapor is condensed. Due to the low mass flowrates in the Na-TEC (< 0.1 mg/s), higher order friction terms are neglected and the classical Darcy’s law is used for non-isothermal, compressible sodium vapor flow. At lower temperatures, the sodium vapor density becomes sufficiently small and there is a transition from classic Poiseuille flow (Kn < 0.1) to Knudsen flow (Kn > 10). Furthermore, transport due to binary diffusion is considered for situations where there is a substantial presence of non-condensable argon inside the sodium vapor plenum. Initial modeling results showing expected mass flowrates, temperature profiles, and liquid-vapor interface locations are presented for various physical conditions. Finally, the main design features of an experimental set-up used to demonstrate this capillary pumping is described in detail, including the method used to measure the low sodium mass flowrates. Initial experimental results demonstrating sodium pumping for a range of temperatures (800K – 1100K) will be presented and compared against the model predictions. A pump curve used to gauge the performance of this pumping mechanism is also created.

14 SOLAR ENERGY↗

Sodium Pumping via Condensation within a Non-Wetting Porous Structure

The transfer of liquid sodium from a low-pressure condenser to a high-pressure evaporator is required to complete the thermodynamic cycle of a sodium thermal electrochemical converter (Na-TEC). A unique capillary pump is explored in this work, whereby low-pressure sodium vapor is condensed within a non-wetting (i.e. contact angle > pi/2) stainless steel porous structure. Due to the curvature of the non-wetting liquid-vapor interface, the liquid adjacent to the interface is at a higher pressure than the vapor. This is in contrast to traditional wicks, where the liquid adjacent to the interface has a lower pressure. Conjugate heat transfer techniques are used to model the coupled momentum and thermal transport processes within this non-wetting porous structure. Due to the low mass flowrates in the Na-TEC (< 0.1 mg/s), higher order friction terms are neglected and the classical Darcy’s law is used for the non-isothermal, compressible vapor flow. At lower temperatures, the sodium vapor density becomes sufficiently small and there is a transition from classic Poiseuille flow (Kn < 0.1) to Knudsen flow (Kn > 10). Furthermore, transport due to binary diffusion is also considered for situations where there is a substantial presence of non-condensable argon in the sodium vapor plenum. Initial modeling results showing expected mass flowrates, temperature profiles, and liquid-vapor interface locations are presented for various physical conditions. The main design features of an experimental set-up used to demonstrate this capillary pumping is also described in detail, including the method used to measure the low sodium mass flowrates. Initial experimental results demonstrating sodium pumping for a range of temperatures (800K – 1100K) will be presented and compared against the model predictions. Finally, several of the challenges with this experiment will be discussed, and specific strategies used to address these are presented.

14 SOLAR ENERGY↗

Stasis PCM Test Results

A phase change material product distributed by Stasis Group, designed to reduce the cooling energy requirements of multi-story commercial buildings, was tested in a side-by-side comparison at FLEXLAB® (LBNL, 2018), a calibrated test facility for low energy building technology solutions. The product was installed according to Stasis recommendations in the ceiling plenum of a 600 ft 2 cell representative of an office space, while an identical cell was operated in the same conditions, except for the night-time pre-cooling sequence and without the product, to gather baseline data. The cells were operated to replicate summer conditions of a candidate office building for retrofit. For the tests conducted at FLEXLAB, two Phase Change Material (PCM) compositions were tested, with the second product having an upgraded composition for thermal performance and upgraded packaging that was used to meet with fire safety requirements for a plenum application. Two rounds of tests were performed, which were designed to collect data for both core (designated as Round 1) and perimeter (Round 2) office space conditions. Following the analysis of the data collected during Round 1, the experimental design was modified to better represent the thermal conditions of a typical office space in relation to the PCM performance. A new product was also brought in for testing in Round 2, which had an improved operational temperature range and packaging properties. In Round 1, multiple tests were conducted to evaluate the performance of the product under different conditions of internal loads, temperature setpoints, pre-cooling strategies and temperature control strategies. In Round 2, the internal conditions were kept constant, while the test conditions only differ in the amount of PCM installed in the test cell plenum and the length of the nighttime pre-cooling sequence. The performance benefits of PCM are generally two-fold: the material may reduce peak cooling energy use during daytime hours (a peak demand energy use benefit) and may allow for energy savings with pre-cooling at night through night flush HVAC controls when night time outside air temperatures are lower, and fan energy use for cooling is more efficient than the use of daytime compressor-based cooling. The focus of this research project was mainly on quantifying the energy savings potential of the latter case although some effects on peak reduction were noted. Between the cell with PCM and nighttime precooling and the reference cell without PCM or precooling, a reduction in cooling load during occupied hours was noted between 7.6 kWh (or 22% of occupied hours cooling load) and 12.5 kWh (or 33% of occupied pg. 7 hours cooling load). Future work can further evaluate the peak cooling load reduction benefits of this product in more detail. This report highlights the results of Round 2, which reflect the performance of the modified PCM product when operated in suitable conditions. The results of Round 1, along with an analysis of the experimental data to identify the factors that prevented the product from performing as desired are presented in Appendix B.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Counter cross-flow evaporator geometries for supercritical organic Rankine cycles

With recent advancements in advanced manufacturing techniques, it is now possible to fabricate complex geometries that take advantage of well known principles of heat transfer. Therefore, unconventional configurations to enhance effectiveness beyond conventional designs can now be considered for practical application. Thermal performance and overall cost of a new design of heat exchangers in counter cross-flow configurations are studied using a simplified but accurate computational method. The new heat exchanger design was introduced and studied previously for a cross-flow configuration by Sabau et al. (2016, 2018). This new design concept uses multi-scale configurations with successive plenums for the working fluid. At the smallest scale the tubes are sized to be equal to the hydraulic entrance length of the inside fluid, in accord with constructal design. With this being said, results indicate that compared to the earlier cross-flow configuration, the counter cross-flow arrangement improves the thermal performance of the heat exchanger by as much as 17% and lowers the total cost by as much as 14%.

42 ENGINEERING↗

Studying the effect of the upper internal structure design on thermal stratification in sodium fast reactors

Thermal stratification and mixing in large reactor pools can pose significant issues with regard to operation and safety of nuclear plants. While significant work has been done in this area on light water reactors it is more critical for sodium reactors and there is far less data with regard to low Prandtl number fluids. Here this paper focuses on the effect of the upper internal structure on the formation of thermal stratification in a scaled sodium fast reactor upper plenum. Six different upper internal structure configurations were tested to observe the effect on thermal stratification. The degree of stratification was quantified using the stratification number. Each configuration was tested from low to high flow rates at a temperature difference of 50 and 100 °C. Over this broad array of testing, it was observed that higher flow rates, more porosity in the upper internal structure design, and a smaller temperature difference yielded a lower degree of stratification. This information can be used to aid in the design of the upper internal structure in a sodium fast reactor. Furthermore, this high resolved temperature data can be used to verify models under prototypic low Prandtl numbers.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Visual Inspection of Defense Waste Processing Facility Melter 2 Interior after End of Service

Defense Waste Processing Facility (DWPF) Melter 2 reached its end of service life after nearly14 years. A visual inspection of the interior of the melter was performed using a remotely operated camera to provide insight into melter performance and potential failure mechanisms. The condition of the interior of the melter was generally good considering its relatively long service life. The plenum refractory appeared to be in good condition. Spalling and wear of the glass contact refractory was evident at the melt line. There appeared to be some degree of degradation and deposition of material at the dome heater penetrations. Deformation, or sagging of the dome heaters was visible. Only the top surfaces of the upper electrodes were visible due to the full inventory of glass remaining after melter shutdown. The electrodes exhibited small cracks as well as minor deformation (creep or slumping). The lower electrode failure mechanism could not be determined since it was not visible.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

25-Pin metallic fuel performance benchmark case based on the EBR-II X430 experiments series

A metallic fuel benchmark case was developed for the fuel performance code BISON based on 25 uranium-zirconium and uranium-plutonium-zirconium pins of the Experimental Breeder Reactor II X430 experiment series. Results of the benchmarks were compared with measurements and calculations made at the time of the experiment as well as subsequent measurements reported in 2019. The comparisons were used to quantify the accuracy of the BISON predictions and to identify patterns in the BISON differences.BISON predicted burnup, plenum pressure, and fission gas release fractions accurately. BISON temperature predictions were somewhat cooler than the temperatures determined at the time of the experiment but appeared to be reasonably accurate considering uncertainties in the legacy temperature calculations, uncertainties in the legacy linear heat rate calculations, and the high sensitivities of the BISON-predicted temperatures to BISON inputs. Fuel axial elongation predictions had errors correlated to fuel composition; BISON tended to underpredict the elongation of binary fuels and overpredict the elongation of ternary fuels. BISON cladding radial dilation predictions were also significantly lower than legacy PIE measurements.Recommendations were made to improve the BISON fuel gaseous swelling model to account for fuel composition, to add additional capabilities to the coolant channel temperature model to ease benchmark development, and to continue developing benchmark cases based on a wide range of experiments in several reactors. Once a wide array of benchmarks is developed, an attempt can be made to enhance or calibrate BISON models to improve the cladding dilation predictions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗