Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Hiss or equatorial noise? Ambiguities in analyzing suprathermal ion plasma wave resonance

Previous studies have shown that low-energy ion heating occurs in the magnetosphere due to strong equatorial noise emission. Observations from the Van Allen Probes Helium Oxygen Proton Electron (HOPE) instrument recently determined that there was a depletion in the 1–10 eV ion population in the postmidnight sector of Earth during quiet times at L < 3. The diurnal variation of equatorially mirroring 1–10 eV H + ions at 2 < L < 3 is connected with similar diurnal variation in the electric field component of plasma waves ranging between 150 and 600 Hz. Measurements from the Van Allen Probes Electric and Magnetic Field Instrument Suite and Integrated Science (EMFISIS) data set are used here to analyze waves of this frequency in near-Earth space. However, when we examine the polarization of the waves in the 150 to 600 Hz range in the equatorial plane, the majority are right-hand polarized plasmaspheric hiss waves. The 1–10 eV H + equatorially mirroring population does not interact with right-hand waves, despite a strong statistical relationship suggesting that the two are linked. We present evidence supporting the relationship, both in our own work and the literature, but we ultimately conclude that the 1–10 eV H + heating is not related to the strong enhancement of 150 to 600 Hz waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic and electric bulge-test instrument for the determination of coupling mechanical properties of functional free-standing films and flexible electronics

For the first time a novel multi-field bulge-test instrument which enables measurements of the biaxial mechanical properties and electro-magnetic-mechanical coupling effect of free-standing films in external magnetic/electric fields was proposed. The oil pressure was designed with two ranges, 0–1 MPa for elastic small deformation and 0–7 MPa for plastic/damage large deformation. A magnetic field that was horizontal and uniform in the film plane was supplied by a hollow cylindrical magnet. The magnitude could be changed from 0 to 10 000 Oe by adjusting the position of the testing film. Meanwhile, an electric field applied on the film was provided by a voltage source (Maximum voltage: 1000 V; Maximum current: 1 A). Various signals related to deformation, mechanical loading, magnetic field, and electric field could be measured simultaneously without mutual interference, which was confirmed by the coincidence of the measured P-H curves for titanium (Ti)/nickel (Ni) specimens with/without external fields. A hardening phenomenon under magnetic/electric fields was observed for Ni and lead zirconate titanate specimens. The multi-field bulge-test instrument will provide a powerful research tool to study the deformation mechanism of functional films and flexible electronics in the coupling field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systematic evaluation of magnetic sensitivities of anisotropic magnetoresistive sensors at liquid helium temperature for superconducting cavities

Trapped magnetic flux in bulk superconductors reduces the quality factor Q in superconducting radio-frequency (SRF) cavities. However, the mechanisms underlying flux trapping and radio-frequency loss are not well understood. Detailed observation of the magnetic distributions is important for understanding such phenomena. Magnetic field mapping is useful for observing the magnetic field distribution around SRF cavities. Measuring the change in the magnetic field around the cavity elucidates the flux trapping behavior. Anisotropic magnetoresistive (AMR) sensors are inexpensive and small devices that can detect magnetic flux density. The magnetic sensitivities of AMR sensors need to be evaluated at liquid helium temperature for the magnetic field mapping of SRF cavities. In this study, a test stand was constructed to calibrate the magnetic sensitivities of AMR sensors in liquid helium, and 110 AMR sensors were tested using this stand. The magnetic sensitivities were evaluated systematically. A solenoid coil was used to control the uniform external magnetic field and to measure the magnetic sensitivity at low temperatures. All AMR sensors exhibited suitable sensitivities to the magnetic field around the SRF cavity. The variation in these sensitivities in all AMR sensors was ~1%. Further, the AMR sensors were found to have sufficient sensitivity for mapping the magnetic field around the exterior surface of the SRF cavity.

43 PARTICLE ACCELERATORS↗

NSLS-II HIGH LEVEL APPLICATION INFRASTRUCTURE AND CLIENT API DESIGN

The beam commissioning software framework of NSLS-II project adopts a client/server based architecture to replace the more traditional monolithic high level application approach. It is an open structure platform, and we try to provide a narrow API set for client application. With this narrow API, existing applications developed in different language under different architecture could be ported to our platform with small modification. This paper describes system infrastructure design, client API and system integration, and latest progress. As a new 3rd generation synchrotron light source with ultra low emittance, there are new requirements and challenges to control and manipulate the beam. A use case study and a theoretical analysis have been performed to clarify requirements and challenges to the high level applications (HLA) software environment. To satisfy those requirements and challenges, adequate system architecture of the software framework is critical for beam commissioning, study and operation. The existing traditional approaches are self-consistent, and monolithic. Some of them have adopted a concept of middle layer to separate low level hardware processing from numerical algorithm computing, physics modelling, data manipulating, plotting, and error handling. However, none of the existing approaches can satisfy the requirement. A new design has been proposed by introducing service oriented architecture technology. The HLA is combination of tools for accelerator physicists and operators, which is same as traditional approach. In NSLS-II, they include monitoring applications and control routines. Scripting environment is very important for the later part of HLA and both parts are designed based on a common set of APIs. Physicists and operators are users of these APIs, while control system engineers and a few accelerator physicists are the developers of these APIs. With our Client/Server mode based approach, we leave how to retrieve information to the developers of APIs and how to use them to form a physics application to the users. For example, how the channels are related to magnet and what the current real-time setting of a magnet is in physics unit are the internals of APIs. Measuring chromaticities are the users of APIs. All the users of APIs are working with magnet and instrument names in a physics unit. The low level communications in current or voltage unit are minimized. In this paper, we discussed our recent progress of our infrastructure development, and client API.

43 PARTICLE ACCELERATORS↗

COMPARISON OF CORONAL EXTRAPOLATION METHODS FOR CYCLE 24 USING HMI DATA

Two extrapolation models of the solar coronal magnetic field are compared using magnetogram data from the Solar Dynamics Observatory /Helioseismic and Magnetic Imager instrument. The two models, a horizontal current–current sheet–source surface (HCCSSS) model and a potential field–source surface (PFSS) model, differ in their treatment of coronal currents. Each model has its own critical variable, respectively, the radius of a cusp surface and a source surface, and it is found that adjusting these heights over the period studied allows for a better fit between the models and the solar open flux at 1 au as calculated from the Interplanetary Magnetic Field (IMF). The HCCSSS model provides the better fit for the overall period from 2010 November to 2015 May as well as for two subsets of the period: the minimum/rising part of the solar cycle and the recently identified peak in the IMF from mid-2014 to mid-2015 just after solar maximum. It is found that an HCCSSS cusp surface height of 1.7 R {sub ⊙} provides the best fit to the IMF for the overall period, while 1.7 and 1.9 R {sub ⊙} give the best fits for the two subsets. The corresponding values for the PFSS source surface height are 2.1, 2.2, and 2.0 R {sub ⊙} respectively. This means that the HCCSSS cusp surface rises as the solar cycle progresses while the PFSS source surface falls.

79 ASTRONOMY AND ASTROPHYSICS↗

The occurrence and wave properties of H⁺-, He⁺-, and O⁺-band EMIC waves observed by the Van Allen Probes

We perform a statistical study of electromagnetic ion cyclotron (EMIC) waves detected by the Van Allen Probes mission to investigate the spatial distribution of their occurrence, wave power, ellipticity, and normal angle. The Van Allen Probes have been used which allow us to explore the inner magnetosphere (1.1 to 5.8 RE). Magnetic field measurements from the Electric and Magnetic Field Instrument Suite and Integrated Science on board the Van Allen Probes are used to identify EMIC wave events for the first 22 months of the mission operation (8 September 2012 to 30 June 2014). EMIC waves are examined in H⁺-, He⁺-, and O⁺-bands. Over 700 EMIC wave events have been identified over the three different wave bands (265 H⁺-band events, 438 He⁺-band events, and 68 O⁺-band events). EMIC wave events are observed between L = 2 – 8, with over 140 EMIC wave events observed below L = 4. The results show that H⁺-band EMIC waves have two peak magnetic local time (MLT) occurrence regions: pre-noon (09:00 < MLT ≤ 12:00) and afternoon (15:00 < MLT ≤ 17:00) sectors. He⁺-band EMIC waves feature an overall stronger dayside occurrence. O⁺-band EMIC waves have one peak region located in the morning sector at lower L shells (L < 4). He⁺-band EMIC waves average the highest wave power overall (>0.1 nT²/Hz), especially in the afternoon sector. Ellipticity observations reveal that linearly polarized EMIC waves dominate in lower L shells.

58 GEOSCIENCES↗

Magnetic compressibility of layered ferromagnet under pressure

This study systematically investigates the magnetic properties of the layered ferromagnet MnPt 5 As under pressure through a combination of experimental measurements and theoretical simulations. MnPt 5 As exhibits a ferromagnetic transition at approximately 301 K. Neutron diffraction measurements under applied pressures up to ∼4.9 GPa were performed over a temperature range from 320 to 100 K to probe its magnetic behavior. The results confirm that the Mn atoms maintain a ferromagnetic order under applied pressures, consistent with the ambient-pressure findings. However, magnetic anisotropy is notably suppressed. To further elucidate the compressibility of magnetic anisotropy in MnPt 5 As, x-ray diffraction under pressure was conducted. The results reveal that the c-axis undergoes a greater and more rapid compression compared to the ab -plane, which may contribute to the observed suppression of Mn ferromagnetic ordering along the c -axis. Additionally, theoretical calculations indicate that magnetic ordering exhibits a similar pressure-induced trend under applied pressure, supporting the experimental observations. These findings offer insights into the pressure-dependent magnetic properties and anisotropy of MnPt 5 As, with potential implications for strain engineering in Mn-based magnetic devices.

Electronic band structure↗

PREDICTING CORONAL MASS EJECTIONS USING MACHINE LEARNING METHODS

Of all the activity observed on the Sun, two of the most energetic events are flares and coronal mass ejections (CMEs). Usually, solar active regions that produce large flares will also produce a CME, but this is not always true. Despite advances in numerical modeling, it is still unclear which circumstances will produce a CME. Therefore, it is worthwhile to empirically determine which features distinguish flares associated with CMEs from flares that are not. At this time, no extensive study has used physically meaningful features of active regions to distinguish between these two populations. As such, we attempt to do so by using features derived from (1) photospheric vector magnetic field data taken by the Solar Dynamics Observatory ’s Helioseismic and Magnetic Imager instrument and (2) X-ray flux data from the Geostationary Operational Environmental Satellite’s X-ray Flux instrument. We build a catalog of active regions that either produced both a flare and a CME (the positive class) or simply a flare (the negative class). We then use machine-learning algorithms to (1) determine which features distinguish these two populations, and (2) forecast whether an active region that produces an M- or X-class flare will also produce a CME. We compute the True Skill Statistic, a forecast verification metric, and find that it is a relatively high value of ∼0.8 ± 0.2. We conclude that a combination of six parameters, which are all intensive in nature, will capture most of the relevant information contained in the photospheric magnetic field.

79 ASTRONOMY AND ASTROPHYSICS↗

High-speed digitization readout of silicon photomultipliers for time of flight positron emission tomography

We report on work to develop a system with about 100 picoseconds (ps) time resolution for time of flight positron emission tomography [TOF-PET]. The chosen photo detectors for the study were Silicon Photomultipliers (SiPM's). This study was based on extensive experience in studying timing properties of SiPM's. The readout of these devices used the commercial high speed digitizer DRS4. We applied different algorithms to get the best time resolution of 155 ps Guassian (sigma) for a LYSO crystal coupled to a SiPM. We consider the work as a first step in building a prototype TOF-PET module. The field of positron-emission-tomography (PET) has been rapidly developing. But there are significant limitations in how well current PET scanners can reconstruct images, related to how fast data can be acquired, how much volume they can image, and the spatial and temporal resolution of the generated photons. Typical modern scanners now include multiple rings of detectors, which can image a large volume of the patient. In this type of scanner, one can treat each ring as a separate detector and require coincidences only within the ring, or treat the entire region viewed by the scanner as a single 3 dimensional volume. This 3d technique has significantly better sensitivity since more photon pair trajectories are accepted. However, the scattering of photons within the volume of the patient, and the effect of random coincidences limits the technique. The advent of sub-nanosecond timing resolution detectors means that there is potentially much better rejection of scattered photon events and random coincidence events in the 3D technique. In addition, if the timing is good enough, then the origin of photons pairs can be determined better, resulting in improved spatial resolution - so called 'Time-of-Flight' PET, or TOF-PET. Currently a lot of activity has occurred in applications of SiPMs for TOF-PET. This is due to the devices very good time resolution, low profile, lack of high voltage needed, and their non-sensitivity to magnetic fields. While investigations into this technique have begun elsewhere, we feel that the extensive SiPM characterization and data acquisition expertise of Fermilab, and the historical in-depth research of PET imaging at University of Chicago will combine to make significant strides in this field. We also benefit by a working relationship with the SiPM producer STMicroelectronics (STM).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced magnetocaloric effects in metastable phases of Mn 1- x Co x NiGe generated through thermal quenching and high-pressure annealing

Metastable phases were formed in Mn 1-x Co x NiGe (x = 0.05 and 0.08) by annealing at 800 °C followed by rapid cooling, i.e., quenching, at ambient pressure (P = 0) and under a pressure of P = 3.5 GPa, and their phase transitions and associated magnetocaloric properties were investigated. The crystal cell volumes of the metastable phases decreased, and their structural transitions significantly shifted to lower temperatures relative to those of the slow-cooled compounds, with a greater reduction observed in the samples where the rapid cooling occurred under high pressures. The magnetic and structural transitions coupled to form a magnetostructural transition in the metastable phases, resulting in large magnetic entropy changes up to -79.6 J kg -1 K -1 (x = 0.08 ) for a 7-T field change. As a result, the experimental results demonstrate thermal quenching and high-pressure annealing as alternative methods to create magnetostructural transitions, without modifying the compositions of the materials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Insert Coil Test for HEP High Field Magnets Using YBCO Coated Conductor Tapes

The final beam cooling stages of a Muon Collider may require DC solenoid magnets with magnetic fields of 30-50 T. In this paper we present progress in insert coil development using commercially available YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} Coated Conductor. Technological aspects covered in the development, including coil geometry, insulation, manufacturing process and testing are summarized and discussed. Test results of double pancake coils operated in liquid nitrogen and liquid helium are presented and compared with the performance of YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} tape short samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Small-angle neutron polarimetry apparatus (SANPA): Development at the NIST Center for Neutron Research

Spherical neutron polarimetry directly measures the rotation of the neutron polarization after scattering from materials with magnetic structure. It is an under utilized measurement technique that is capable of measuring all nine elements of the polarization tensor of a material. In this article, we describe our new cryogen-free small-angle neutron polarimetry apparatus and infrastructure at the NIST Center for Neutron Research. The resulting apparatus is capable of continuous operation and is designed for measurements at low temperatures (4–8 K) using niobium Meissner shielding and mu-metal shielding to produce a zero-field (≤1 μT) cooling sample environment.

47 OTHER INSTRUMENTATION↗

On the origin of a sunquake during the 2014 March 29 X1 flare

Helioseismic data from the Helioseismic Magnetic Imager instrument have revealed a sunquake associated with the X1 flare SOL2014-03-29T17:48 in active region NOAA 12017. We try to discover if acoustic-like impulses or actions of the Lorentz force caused the sunquake. We analyze spectropolarimetric data obtained with the Facility Infrared Spectrometer (FIRS) at the Dunn Solar Telescope (DST). Fortunately, the FIRS slit crossed the flare kernel close to the acoustic source during the impulsive phase. The infrared FIRS data remain unsaturated throughout the flare. Stokes profiles of lines of Si I 1082.7 nm and He I 1083.0 nm are analyzed. At the flare footpoint, the Si I 1082.7 nm core intensity increases by a factor of several, and the IR continuum increases by 4% ± 1%. Remarkably, the Si I core resembles the classical Ca II K line's self-reversed profile. With nLTE radiative models of H, C, Si, and Fe, these properties set the penetration depth of flare heating to 100 ± 100 km (i.e., photospheric layers). Estimates of the non-magnetic energy flux are at least a factor of two less than the sunquake energy flux. Milne-Eddington inversions of the Si I line show that the local magnetic energy changes are also too small to drive the acoustic pulse. Our work raises several questions. Have we missed the signature of downward energy propagation? Is it intermittent in time and/or non-local? Does the 1-2 s photospheric radiative damping time discount compressive modes?.

79 ASTRONOMY AND ASTROPHYSICS↗

Conceptual design of extended magnetic probe set to improve 3D field detection in NSTX-U

Adding toroidal arrays of magnetic probes at the top and bottom of NSTX-U would improve both the detection of the multimodal plasma response to applied magnetic perturbations and the identification of the poloidal structure of unstable plasma modes, as well as contribute to the validation of MHD models, improve the understanding of the plasma response to external fields, and improve the error field correction. In this paper, the linear MHD code MARS-F/K has been used to identify poloidal locations that would improve the capability to measure stationary or near-stationary 3D fields that may result from the plasma response to external sources of non-axisymmetric fields. The study highlighted 6 poloidal positions where new arrays of both poloidal and radial magnetic field sensors would improve the poloidal resolution. Here, the proposed set of new arrays combined with the present ones is shown to be capable of measuring the poloidal structure of perturbations with n ≤ 6 and of detecting the multimodal plasma response. Assessment of the trade-off in the poloidal length of the probes leads to an ideal length between 10 cm and 30 cm. A method to configure the probes of a toroidal array based on the singular value decomposition condition number is proposed, and an ideal solution and a low-cost one are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Boosting the signal-to-noise of low-field MRI with deep learning image reconstruction

Recent years have seen a resurgence of interest in inexpensive low magnetic field (< 0.3 T) MRI systems mainly due to advances in magnet, coil and gradient set designs. Most of these advances have focused on improving hardware and signal acquisition strategies, and far less on the use of advanced image reconstruction methods to improve attainable image quality at low field. We describe here the use of our end-to-end deep neural network approach (AUTOMAP) to improve the image quality of highly noise-corrupted low-field MRI data. We compare the performance of this approach to two additional state-of-the-art denoising pipelines. We find that AUTOMAP improves image reconstruction of data acquired on two very different low-field MRI systems: human brain data acquired at 6.5 mT, and plant root data acquired at 47 mT, demonstrating SNR gains above Fourier reconstruction by factors of 1.5- to 4.5-fold, and 3-fold, respectively. In these applications, AUTOMAP outperformed two different contemporary image-based denoising algorithms, and suppressed noise-like spike artifacts in the reconstructed images. The impact of domain-specific training corpora on the reconstruction performance is discussed. The AUTOMAP approach to image reconstruction will enable significant image quality improvements at low-field, especially in highly noise-corrupted environments.

42 ENGINEERING↗

Using motional Stark splitting of D$_α$ emission to constrain MHD equilibrium analysis in DIII-D plasmas

Herein we report tests of an alternate technique for constraining MHD equilibrium analysis in tokamak plasmas using internal magnetic field measurements based on |$B$| measurements from the motional Stark splitting of D$_α$ spectral lines emitted by a neutral heating beam (MSE-LS). We compare results using MSE-LS with those of the standard equilibrium analysis technique based on line polarization of the D$_α$ emission (MSE-LP). An alternative to MSE-LP is needed in future devices such as ITER where MSE-LP will be difficult due to a plasma-induced coating of the first optical element. The tests utilized data from 10 DIII-D shots with 7 MSE-LS and 14 MSE-LP views covering a range of radii along the outer midplane of the plasma. Seven MSE-LS measurements can contribute significantly to the equilibrium reconstruction of pressure and q profiles using both synthetic and experimental DIII-D MSE-LS data. For example, 7 MSE-LS plus seven MSE-LP measurements give a fit quality that is as good as the same cases with 14 MSE-LP measurements. Analyzing synthetic data for 14 MSE-LS measurements shows significant improvement in fitting quality over the case with 7 MSE-LS locations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

STUDY OF THE 3D GEOMETRIC STRUCTURE AND TEMPERATURE OF A CORONAL CAVITY USING THE LIMB SYNOPTIC MAP METHOD

We present the three-dimensional geometric structure and thermal properties of a coronal cavity deduced from limb synoptic maps. The observations are extreme ultraviolet images from the Atmospheric Imager Assembly (AIA) and magnetic images from the Helioseismic Magnetic Imager instruments on board the Solar Dynamics Observatory. We describe a limb synoptic-map method used to effectively identify and measure cavities from annuli of radiance above the solar limb. We find that cavities are best seen in the 211, 193, and 171 Å passbands. The prominence associated with each cavity is best seen in the 304 Å synoptic maps. We also estimate the thermal properties of the cavity and surrounding plasma by combining the AIA radiances with a differential emission measure analysis. This paper focuses on one long cavity from a catalog of coronal cavities that we are developing. Cavities in this catalog are designated by a coded name using the Carrington Rotation number and position. Cavity C211347177N was observed during Carrington Rotation 2113 at the northwestern limb of the solar disk with an average latitude of 47° N and a central longitude of 177°. We showed the following. (1) The cavity is a long tube with an elliptical cross-section with ratios of the length to width and the length to height of 11:1 and 7:1, respectively. (2) The cavity is about 1360 Mm long, or 170° in longitude. (3) It is tilted in latitude. (4) And it is slightly hotter than its surroundings.

79 ASTRONOMY AND ASTROPHYSICS↗

High-Speed Active Integrators for Magnetic Probes

This report discusses a low cost, easy to develop instrument to measure magnetic fields in pulsed solenoids used for the MagNIF pulse power system. The instrument is designed to integrate voltage signals from custom B-dot probes made from PCB inductor chips. The instrument is battery powered with ± 9V rails. Acceptable B-dot probe inputs range from mV to 20V with frequencies up to 4MHz. Details of the circuit design and practical considerations for working with high speed signals are discussed.

42 ENGINEERING↗