A magnetic field measurement technique using a miniature transducer

The development, fabrication, and application of a magnetometer are described. The magnetometer has a miniature transducer and is capable of automatic scanning. The magnetometer described here is capable of detecting static magnetic fields as low as 1.6 A/m and its transducer has an active area 0.64 mm by 0.76 mm. Thin and rugged, the transducer uses wire, 0.05 mm in diameter, which is plated with a magnetic film, enabling measurement of transverse magnetic fields as close as 0.08 mm from a surface. The magnetometer, which is simple to operate and has a fast response, uses an inexpensive clip-on milliammeter (commonly found in most laboratories) for driving and processing the electrical signals and readout. A specially designed transducer holding mechanism replaces the XY recorder ink pen; this mechanism provides the basis for an automatic scanning technique. The instrument has been applied to the measurements of magnetic fields arising from remanent magnetization in experimental plated-wire memory planes and regions of magnetic activity in geological rock specimens.

Fales, C. L., Jr.

Development of a capacitance measurement for pulsed magnetic fields

Capacitance measurements are crucial for probing the electrical properties of materials. In this study, we develop and implement a capacitance measurement technique optimized for pulsed magnetic fields. Our approach employs an auto-balancing bridge method, leveraging a high-bandwidth transimpedance amplifier to mitigate parasitic contributions from coaxial cables. This technique enables precise capacitance measurements in rapidly changing magnetic fields, as demonstrated in experiments on the magnetoelectric material NiCo 2 TeO 6 . The results reveal strong magnetoelectric coupling, including a pronounced hysteresis in capacitance that coincides with magnetization measurements and an enhanced energy dissipation peak at high sweep rates. Compared to traditional LCR meter measurements in DC fields, our method exhibits excellent agreement while providing additional insight into field-induced phase transitions. This work establishes a robust methodology for capacitance measurements under extreme conditions and opens new opportunities for studying multiferroic and correlated electron systems under high magnetic fields.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Absolute magneto-optical measurement of magnetic field on a long pulse high electrical current driven solenoid

We describe a direct absolute magneto-optical approach to measuring the magnetic field driven by long pulse width (>5 ms) and high electrical current (∼kA) in a solenoidal coil. The magnetic field and electrical current are among the most important operating parameters in lightning research and electrical power distribution and are essential to understanding the properties of the radiation output in pulsed energy accelerators as well as other research platforms. However, accurately measuring these magnetic fields and electrical currents using conventional electrical diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element material sensing crystal that is highly resistant to electromagnetic interference, allows for absolute measurement, and does not require an external calibration. Here, we focus on device theory, operating parameters, magneto-optical results from an experiment on a high current solenoid, and comparison with a calculation of the magnetic field and reference electrical current flowing downstream of the solenoid.

Owens, Israel [Sandia National Laboratories (SNL-N

Modeling of injected current stream-induced 3D perturbations in local helicity injection plasmas

Solenoid-free tokamak startup techniques are essential for spherical tokamaks and offer a pathway to cost reduction and design simplification in fusion energy systems. Local helicity injection (LHI) is one such approach, employing compact edge current sources to drive open field line current that initiates and sustains tokamak plasmas. The recently commissioned Pegasus-III Experiment provides a platform for advancing this and other solenoid-free startup methods. This study investigates the effect of LHI on magnetic topology in Pegasus-III plasmas. A helical filament model represents the injected current, and the linear plasma response to its three-dimensional field is calculated with M3D-C1. Poincaré mapping reveals substantial flux surface degradation in all modeled cases. The onset of overlapping magnetic structures and large-scale surface deformation begins near Ψ N ≈ 0.37, indicating a broad region of perturbed topology extending toward the edge. In rotating plasmas, both single-fluid and two-fluid models exhibit partial screening of the n = 1 perturbation, with two-fluid calculations showing stronger suppression near the edge. In contrast, the absence of rotation leads to strong resonant field amplification in the single-fluid case, while the two-fluid case with zero electron rotation mitigates this amplification and preserves edge screening. Magnetic probe measurements indicate that modeling the stream with spatial spreading—representing distributed current and/or oscillatory motion—better reproduces measured magnetic power profiles than a rigid filament model. The results underscore the role of rotation and two-fluid physics in screening stream perturbations and point to plasma flow measurements and refined stream models as key steps toward improving predictive fidelity.

Schaefer, Carolyn E. [Univ. of Wisconsin, Madison,

Measurements of magnetic fields in solar prominences

Magnetic fields can be measured, in solar prominences, by means of two different basic mechanisms that are responsible for the introduction (or the reduction) of a given amount of polarization in spectral lines: these are the Zeeman effect and the Hanle effect. Through the splitting of the magnetic components of a spectral line, the Zeeman effect is capable of introducing a certain amount of circular polarization across the line profile. The Hanle effect consist of a modification of the linear polarization that is induced in spectral lines by the anisotropic illumination of the prominence plasma by the photospheric radiation field. These two effects are briefly discussed.

Deglinnocenti, Egidio Landi

Two-stage magnetometer measures weak magnetic fields

Sensitive magnetometer capable of measuring field strengths of 10 nanogauss is described. High permeability core is aligned parallel to magnetic field in first stage. In second stage, ferromagnetic toroid saturates rapidly. Adjustment of turns and area ratios of each stage provides wide range of sensitivities.

Buntenbach, R. W.

Synthesis of a series of rare-earth-based multi-anion chalcogenide iodides RE 3 Si 2 Se x S 8− x I (RE = La, Ce, Pr, and Nd) using the flux-assisted boron–chalcogen mixture method

Single crystals and polycrystalline powders of rare earth mixed chalcogenide iodides La 3 Si 2 Se 1.21 S 6.79 I, Ce 3 Si 2 Se 1.39 S 6.61 I, Pr 3 Si 2 Se 1.22 S 6.78 I, and Nd 3 Si 2 Se 1.18 S 6.82 I were prepared using the reactive flux-assisted boron–chalcogen mixture (BCM) method at 850 °C. All compounds crystallized in the monoclinic crystal system, space group C2/c (space group number 15). The series adopts the La 3 Si 2 O 8 Cl structure type, containing isolated SiQ 4 tetrahedra connected by REQ 8 (RE = La, Ce, Pr and Nd) polyhedra; this arrangement creates tunnels that are filled by I atoms. The partial substitution of S by Se was carried out to modulate the optical properties. Phase pure samples and uniform solid solutions were obtained for all compositions as determined using powder X-ray diffraction patterns. Polycrystalline powders were used for physical property measurements, including magnetic susceptibility and UV-Vis diffuse reflectance. The solid-state UV-Vis data for the polycrystalline La 3 Si 2 Se 1.21 S 6.79 I, Ce 3 Si 2 Se 1.39 S 6.61 I, and Pr 3 Si 2 Se 1.22 S 6.78 I samples revealed band gaps of E g = 2.5(1), 2.2(1), and 2.3(1) eV, typical of semiconductors. Magnetic measurements indicated that Ce 3 Si 2 Se 1.39 S 6.61 I and Nd 3 Si 2 Se 1.18 S 6.82 I exhibit paramagnetic behavior with slightly negative Weiss constants θ = −25 and −38. The photoluminescence spectrum of Ce 3 Si 2 Se 1.39 S 6.61 I exhibits a broad emission band around ∼493 nm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Cryogenics for spacecraft

It is pointed out that cryogenic engineering has been an integral part of space research almost from the beginning of the space age because of the significant performance advantages available from cryogenically fueled rocket engines. In recent years, space-related cryogenic engineering has expanded from booster engines to include spacecraft systems because of the vastly improved performance available from cooled detectors and systems. The requirements for detector cooling in space are examined, taking into account earth observation, atmospheric measurements, infrared astronomy, X-ray astronomy, gamma-ray astronomy, radio astronomy, relativity measurements, magnetic field measurements, time measurements, and data processing. A description is presented of 1978-1981 U.S. spacecraft cryogenic detector systems.

Vorreiter, J. W.

C/NOFS Measurements of Magnetic Perturbations in the Low-Latitude Ionosphere During Magnetic Storms

The Vector Electric Field Investigation suite on the C/NOFS satellite includes a fluxgate magnetometer to monitor the Earth s magnetic fields in the low-latitude ionosphere. Measurements yield full magnetic vectors every second over the range of +/-45,000 nT with a one-bit resolution of 1.37 nT (16 bit A/D) in each component. The sensor s primary responsibility is to support calculations of both V x B and E x B with greater accuracy than can be obtained using standard magnetic field models. The data also contain information about large-scale current systems that, when analyzed in conjunction with electric field measurements, promise to significantly expand understanding of equatorial electrodynamics. We first compare in situ measurements with the POMME (Potsdam Magnetic Model of the Earth) model to establish in-flight sensor "calibrations" and to compute magnetic residuals. At low latitudes the residuals are predominately products of the storm time ring current. Since C/NOFS provides a complete coverage of all local times every 97 min, magnetic field data allow studies of the temporal evolution and local time variations of storm time ring current. The analysis demonstrates the feasibility of using instrumented spacecraft in low-inclination orbits to extract a timely proxy for the provisional Dst index and to specify the ring current s evolution.

Le, Guan

Pioneer Solar Plasma and Magnetic Field Measurements in Interplanetary Space During August 2-17, 1972

Solar wind plasma and magnetic field measurements from Pioneers 9 and 10 during August 2-17, 1972, reveal complex and large-amplitude variations on a one-hour time scale and numerous discontinuities. During this time period an approximate radial alignment of the two spacecraft as seen from the Sun occurred with heliocentric distances of 0.8 AU for Pioneer 9 and 2.2 AU for Pioneer 10, both at 45 deg east of the Earth's solar longitude. The peak hourly average solar wind proton bulk velocity measured at Pioneer 9 was 990 km sec (exp -1) during hour 0 UT of August 5. The peak hourly average proton number density was 62 cm (exp -3) during hour 11 UT of August 3. The peak solar wind speeds are generally much reduced at Pioneer 10 compared with those observes at Pioneer 9. The peak 30 minute average magnetic field magnitude was 85 gamma during 1245 - 1315 UT of August 3. The Pioneer 9 data indicate passage of four fast forward interplanetary shocks, and one slow forward interplanetary shock.

Mihalov, J. D.

Venera-9 magnetic field measurements in the Venus wake - Evidence for an earth-like interaction

Venera-9 magnetic field measurements in the Venus wake provide additional support for the hypothesis that Venus has an intrinsic planetary field. The observed field is in the direction expected for a northward moment, and is similar to that observed in equivalent locations in the terrestrial magnetosphere, both in its temporal and spatial behavior. In particular, Venera-9 appears to have observed a plasma sheet expansion, field-aligned currents, and tail-field dipolarization.

Russell, C. T.

Magnetic Susceptibility Measurements for in Situ Characterization of Lunar Soil

Magnetic separation is a viable method for concentration of components of lunar soils and rocks for use as feedstocks for manufacture of metals, oxygen, and for recovery of volatiles such as He-3. Work with lunar materials indicates that immature soils are the best candidates for magnetic beneficiation. The magnetic susceptibility at which selected soil components such as anorthite, ilmenite, or metallic iron are separated is not affected by soil maturity, but the recovery of the concentrated components is. Increasing soil maturity lowers recovery. Mature soils contain significant amounts of glass-encased metallic iron. Magnetic susceptibility, which is sensitive to metallic iron content, can be used to measure soil maturity. The relationship between the ratio of magnetic susceptibility and iron oxide and the conventional maturity parameter, I(sub s)/FeO, ferromagnetic resonant intensity divided by iron oxide content is given. The magnetic susceptibilities were determined using apparatus designed for magnetic separation of the lunar soils.