Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

The energy confinement response of DIII-D plasmas to Resonant Magnetic Perturbations

Here, Resonant Magnetic Perturbations (RMPs) are a leading method for edge localized modes (ELMs) Control in fusion plasmas. However they can also cause a rapid degradation in energy confinement. In this paper we show that the energy confinement in low collisionality (v* e < 0.3) DIII-D ITER Similar Shape (ISS) plasmas often recovers after several energy confinement times for RMP amplitudes up to the threshold for ELM suppression. Immediately following the application of the RMP, the plasma stored energy decreases in proportion to the decrease in the line-averaged density during density "pump-out". Later in the discharge confinement recovery is observed in the thermal ion channel and is correlated with the increase in the ion temperature at the top of the H-mode pedestal. A correlation between the inverse scale length of the ion temperature (α/L Ti ) and the E x B shearing rate at the top of the pedestal is seen during the confinement recovery phase. Transport analysis reveals that the confinement improvement in the ion channel results from the self-similarity in the ion temperature profiles in the plasma core combined with the observed increase in α/L Ti in the plasma edge following density pump-out. In contrast the electron temperature scale length (α/L Ti ) remains essentially unchanged in response to the application of the RMP. At significantly higher RMP levels the edge EXB shearing rate and α/L Ti does not increase and the confinement does not recover following density pump-out.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Automatic segmentation of the glenohumeral cartilages from magnetic resonance images

Purpose: Magnetic resonance (MR) imaging plays a key role in investigating early degenerative disorders and traumatic injuries of the glenohumeral cartilages. Subtle morphometric and biochemical changes of potential relevance to clinical diagnosis, treatment planning, and evaluation can be assessed from measurements derived from in vivo MR segmentation of the cartilages. However, segmentation of the glenohumeral cartilages, using approaches spanning manual to automated methods, is technically challenging, due to their thin, curved structure and overlapping intensities of surrounding tissues. Automatic segmentation of the glenohumeral cartilages from MR imaging is not at the same level compared to the weight-bearing knee and hip joint cartilages despite the potential applications with respect to clinical investigation of shoulder disorders. In this work, the authors present a fully automated segmentation method for the glenohumeral cartilages using MR images of healthy shoulders. Methods: The method involves automated segmentation of the humerus and scapula bones using 3D active shape models, the extraction of the expected bone–cartilage interface, and cartilage segmentation using a graph-based method. The cartilage segmentation uses localization, patient specific tissue estimation, and a model of the cartilage thickness variation. The accuracy of this method was experimentally validated using a leave-one-out scheme on a database of MR images acquired from 44 asymptomatic subjects with a true fast imaging with steady state precession sequence on a 3 T scanner (Siemens Trio) using a dedicated shoulder coil. The automated results were compared to manual segmentations from two experts (an experienced radiographer and an experienced musculoskeletal anatomist) using the Dice similarity coefficient (DSC) and mean absolute surface distance (MASD) metrics. Results: Accurate and precise bone segmentations were achieved with mean DSC of 0.98 and 0.93 for the humeral head and glenoid fossa, respectively. Mean DSC scores of 0.74 and 0.72 were obtained for the humeral and glenoid cartilage volumes, respectively. The manual interobserver reliability evaluated by DSC was 0.80 ± 0.03 and 0.76 ± 0.04 for the two cartilages, implying that the automated results were within an acceptable 10% difference. The MASD between the automatic and the corresponding manual cartilage segmentations was less than 0.4 mm (previous studies reported mean cartilage thickness of 1.3 mm). Conclusions: This work shows the feasibility of volumetric segmentation and separation of the glenohumeral cartilages from MR images. To their knowledge, this is the first fully automated algorithm for volumetric segmentation of the individual glenohumeral cartilages from MR images. The approach was validated against manual segmentations from experienced analysts. In future work, the approach will be validated on imaging datasets acquired with various MR contrasts in patients.

60 APPLIED LIFE SCIENCES↗

Image Distortions on a Plastic Interstitial Computed Tomography/Magnetic Resonance Brachytherapy Applicator at 3 Tesla Magnetic Resonance Imaging and Their Dosimetric Impact

Purpose: To quantify magnetic resonance imaging (MRI) distortions on a plastic intracavitary/interstitial applicator with plastic needles at a field strength of 3 T and to determine the dosimetric impact, using patient data. Methods and Materials: For 11 cervical cancer patients, our clinical MRI protocol was extended with 3 scans. From the first scan, a multi-echo acquisition, a map of the magnetic field (B{sub 0}) was calculated and used to quantify the field inhomogeneity. The expected displacements of the applicator were quantified for the clinical sequence using the measured field inhomogeneity and the clinical sequence's bandwidth. The second and third scan were our routine clinical sequence (duration: <5 minutes each), acquired consecutively using opposing readout directions. The displacement of the applicator between these scans is approximately twice the displacement due to B{sub 0} inhomogeneity. The impact of the displacement on the dose was determined by reconstructing the applicator on both scans. The applicator was then shifted and rotated the same distance as the observed displacement to create a worst-case scenario (ie, twice the actual displacement due to B{sub 0} inhomogeneity). Next, the dose to 98%/90% (D{sub 98}/D{sub 90}) of the clinical target volume at high risk, as well as the dose to the most irradiated 2 cm{sup 3} for bladder and rectum, were calculated for the original plan as well as the shifted plan. Results: For a volume of interest containing the intrauterine device and the ovoids the 95th percentile of the absolute displacement ranged between 0.2 and 0.75 mm, over all patients. For all patients, the difference in D{sub 98}/D{sub 90} in the opposing readout scans with the original plan was at most 4.7%/4.3%. For the dose to the most irradiated 2 cm{sup 3} of bladder/rectum, the difference was at most 6.0%/6.3%. Conclusions: The dosimetric impact of distortions on this plastic applicator with plastic needles is limited. Applicator reconstruction for brachytherapy planning purposes is feasible at 3 T MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Longitudinal and transverse magnetization components in thin films: A resonant magnetic reflectivity investifation using circularly polarized soft x-rays

An in-plane vectorial analysis of the magnetization of thin magnetic films is presented. Longitudinal soft x-ray resonant magnetic reflectivity curves display characteristic nodes where the longitudinal scattering component is suppressed by x-ray interference. The transverse magnetic component can be effectively retrieved at these nodal points, despite the use of circular polarization and longitudinal scattering geometry. Using a single geometric configuration, transverse and longitudinal magnetic hysteresis loops can be clearly separated. Calculations based on a Stoner-Wohlfarth model satisfactorily describe both loops. Therefore, this method presents a viable alternative to standard vectorial analysis techniques, with the additional benefit of element specificity.

36 MATERIALS SCIENCE↗

Magnetic-resonance and thermophysical studies of the magnetic phase diagram for a GdFe{sub 2.1}Ga{sub 0.9}(BO{sub 3}){sub 4} single crystal

The antiferromagnetic resonance, heat capacity, magnetic properties, and magnetic phase diagram of a GdFe{sub 3}(BO{sub 3}){sub 4} crystal in which some of the iron ions were substituted by diamagnetic gallium ions have been investigated. It has been found that the Neel temperature upon diamagnetic substitution decreased to 17 K compared to 38 K in the unsubstituted crystal. The effective exchange and anisotropy fields for GdFe{sub 2.1}Ga{sub 0.9}(BO{sub 3}){sub 4} have been estimated from the field dependences of magnetization and resonance measurements. The magnetic phase diagram of the crystal has been constructed from magnetic and resonance measurements. In GdFe{sub 2.1}Ga{sub 0.9}(BO{sub 3}){sub 4}, there is no spontaneous reorientation and, in the absence of a magnetic field, the crystal remains an easy-axis one in the entire domain of magnetic ordering. The critical field of the reorientation transition to an induced easy-plane state in a magnetic field along the trigonal axis has been found to increase compared to that in the unsubstituted crystal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SQUIDs vs. Faraday coils for ultlra-low field nuclear magnetic resonance: experimental and simulation comparison

Nuclear magnetic resonance (NMR) methods are widely used in medicine, chemistry and industry. One application area is magnetic resonance imaging or MRI. Recently it has become possible to perform NMR and MRI in ultra-low field (ULF) regime that requires measurement field strengths only of the order of 1 Gauss. These techniques exploit the advantages offered by superconducting quantum interference devices or SQUIDs. Our group at LANL has built SQUID based MRI systems for brain imaging and for liquid explosives detection at airports security checkpoints. The requirement for liquid helium cooling limits potential applications of ULF MRI for liquid identification and security purposes. Our experimental comparative investigation shows that room temperature inductive magnetometers provide enough sensitivity in the 3-10 kHz range and can be used for fast liquid explosives detection based on ULF NMR/MRI technique. We describe an experimental and computer simulation comparison of the world's first multichannel SQUID based and Faraday coils based instruments that are capable of performing ULF MRI for liquids identification.

42 ENGINEERING↗

Imaging of the hip joint. Computed tomography versus magnetic resonance imaging

The authors reviewed the applications and limitations of computed tomography (CT) and magnetic resonance (MR) imaging in the assessment of the most common hip disorders. Magnetic resonance imaging is the most sensitive technique in detecting osteonecrosis of the femoral head. Magnetic resonance reflects the histologic changes associated with osteonecrosis very well, which may ultimately help to improve staging. Computed tomography can more accurately identify subchondral fractures than MR imaging and thus remains important for staging. In congenital dysplasia of the hip, the position of the nonossified femoral head in children less than six months of age can only be inferred by indirect signs on CT. Magnetic resonance imaging demonstrates the cartilaginous femoral head directly without ionizing radiation. Computed tomography remains the imaging modality of choice for evaluating fractures of the hip joint. In some patients, MR imaging demonstrates the fracture even when it is not apparent on radiography. In neoplasm, CT provides better assessment of calcification, ossification, and periosteal reaction than MR imaging. Magnetic resonance imaging, however, represents the most accurate imaging modality for evaluating intramedullary and soft-tissue extent of the tumor and identifying involvement of neurovascular bundles. Magnetic resonance imaging can also be used to monitor response to chemotherapy. In osteoarthrosis and rheumatoid arthritis of the hip, both CT and MR provide more detailed assessment of the severity of disease than conventional radiography because of their tomographic nature. Magnetic resonance imaging is unique in evaluating cartilage degeneration and loss, and in demonstrating soft-tissue alterations such as inflammatory synovial proliferation.

Review↗

Prospects for neutron probed magnetic resonance imaging

The information gained from magnetic resonance imaging has provided useful insight into many insulators. Extending this technique to conductors requires an alternative means of spin manipulation besides electromagnetic radiation. A method to use neutron measurement of the Zeeman splitting to measure the relaxation time is described. The Zeeman splitting is observed by a neutron spectrometer as an incoherent signal with an energy transfer equal to the Zeeman energy. This energy scale is so small that fields in excess of 15 T are required to sufficiently separate this line from other incoherent processes. Once the Zeeman splitting is observed, a perturbation of the system is required to enable measurement of the nuclear spin relaxation time; the physical quantity measured in a Nuclear Magnetic Resonance experiment. The proposed perturbation is a pulsed field of 10 T. The relaxation of the Zeeman splitting back to the 15 T condition is then recorded as a function of time. The resultant data is the aforementioned measure of the relaxation time. With the ability to measure the relaxation times the image map can be created by rastering the sample with respect to the beam.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NP-MRD: the Natural Products Magnetic Resonance Database

The Natural Products Magnetic Resonance Database (NP-MRD) is a comprehensive, freely available electronic resource for the deposition, distribution, searching and retrieval of nuclear magnetic resonance (NMR) data on natural products, metabolites and other biologically derived chemicals. NMR spectroscopy has long been viewed as the ‘gold standard’ for the structure determination of novel natural products and novel metabolites. NMR is also widely used in natural product dereplication and the characterization of biofluid mixtures (metabolomics). All of these NMR applications require large collections of high quality, well-annotated, referential NMR spectra of pure compounds. Unfortunately, referential NMR spectral collections for natural products are quite limited. It is because of the critical need for dedicated, open access natural product NMR resources that the NP-MRD was funded by the National Institute of Health (NIH). Since its launch in 2020, the NP-MRD has grown quickly to become the world's largest repository for NMR data on natural products and other biological substances. It currently contains both structural and NMR data for nearly 41,000 natural product compounds from >7400 different living species. All structural, spectroscopic and descriptive data in the NP-MRD is interactively viewable, searchable and fully downloadable in multiple formats. Extensive hyperlinks to other databases of relevance are also provided. The NP-MRD also supports community deposition of NMR assignments and NMR spectra (1D and 2D) of natural products and related meta-data. The deposition system performs extensive data enrichment, automated data format conversion and spectral/assignment evaluation.

59 BASIC BIOLOGICAL SCIENCES↗

Identification of the Ga interstitial in Al(x)Ga(1-x)As by optically detected magnetic resonance

A new optically detected magnetic resonance spectrum in Al(x)Ga(1-x)As is reported and assigned to native Ga interstitials. Luminescence-quenching signals were observed over the energy region from 0.75 to 1.1 eV. The optically detected magnetic resonance is nearly isotropic, with spin-Hamiltonian parameters g = 2.025 + or - 0.006, central hyperfine splitting A(Ga-69) = 0.050 + or - 0.001/cm, and A(Ga-71) = 0.064 + or - 0.001/cm for H near the 001 line. The strong hyperfine coupling denotes an electronic state of A1 symmetry, which current theories predict for the Ga interstitial but not the Ga antisite. The slight anisotropy probably indicates that the Ga(i) is paired with a second, unknown defect.

Kennedy, T. A.↗

Re-Evaluation of 6th Edition of AJCC Staging System for Nasopharyngeal Carcinoma and Proposed Improvement Based on Magnetic Resonance Imaging

Purpose: To use magnetic resonance imaging to re-evaluate and improve the 6th edition of the International Union Against Cancer/American Joint Committee on Cancer staging system for nasopharyngeal carcinoma. Methods and Materials: We performed a retrospective review of the data from 924 biopsy-proven nonmetastatic nasopharyngeal carcinoma cases. All patients had undergone magnetic resonance imaging examinations and received radiotherapy as their primary treatment. Results: The T classification, N classification, and stage group were independent predictors. No significant differences in the local failure hazards between adjacent T categories were observed between Stage T2b and T1, Stage T2b and T2a, and Stage T2b and T3. Although the disease failure hazards for Stage T1 were similar to those for Stage T2a, those for Stage T2b were similar to those for Stage T3. Survival curves of the different T/N subsets showed a better segregation when Stage T2a was downstaged to T1, T2b and T3 were incorporated into T2, and the nodal greatest dimension was rejected. The disease failure hazard for T3N0-N1 subsets were similar to those of the T1-T2N1 subsets belonging to Stage II; the same result was found for the T4N0-N2 subsets in the sixth American Joint Committee on Cancer staging system. However, the staging system we propose shows more consistent hazards within the same stage group and better survival discrimination among T categories, N categories, and overall stages. Conclusion: Using the 6th American Joint Committee on Cancer staging system produces an acceptable distribution of patient numbers and segregation of survival curves among the different stage groups. The prognostic accuracy of the staging system could be improved by recategorizing the T, N, and group stage criteria.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of ringing effects due to magnetic core materials in pulsed nuclear magnetic resonance circuits

This work presents investigations and detailed analysis of ringing in a non-resonant pulsed nuclear magnetic resonance (NMR) circuit. Ringing is a commonly observed phenomenon in high power switching circuits. The oscillations described as ringing impede measurements in pulsed NMR systems. It is therefore desirable that those oscillations decay fast. It is often assumed that one of the causes behind ringing is the role of the magnetic core used in the antenna (acting as an inductive load). We will demonstrate that an LRC subcircuit is also set-up due to the inductive load and needs to be considered due to its parasitic effects. It is observed that the parasitics associated with the inductive load become important at certain frequencies. The output response can be related to the response of an under-damped circuit and to the magnetic core material. This research work demonstrates and discusses ways of controlling ringing by considering interrelationships between different contributing factors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optically Detected Magnetic Resonance Studies on π-conjugated semiconductor systems

Optically Detected Magnetic Resonance (ODMR) techniques were used to investigate the dynamics of excitons and charge carriers in π-conjugated organic semiconductors. Degradation behavior of the negative spin-1/2 electroluminescence-detected magnetic resonance (ELDMR) was observed in Alq3 devices. The increase in the resonance amplitude implies an increasing bipolaron formation during degradation, which might be the result of growth of charge traps in the device. The same behavior of the negative spin-1/2 ELDMR was observed in 2wt% Rubrene doped Tris(8-hydroxyquinolinato)aluminium (Alq3) devices. However, with increasing injection current, a positive spin-1/2 ELDMR, together with positive spin 1 triplet powder patterns at Δm S =±1 and Δm S =±2, emerges. Due to the similarities in the frequency dependences of single and double modulated ELDMR and the photoluminescence-detected magnetic resonance (PLDMR) results in poly[2-methoxy-5-(2 -ethyl-hexyloxy)-1,4-phenyl ene vinylene] (MEH-PPV) films, the mechanism for this positive spin-1/2 ELDMR was assigned to enhanced triplet-polaron quenching under resonance conditions. The ELDMR in rubrene doped Alq3 devices provides a path to investigate charge distribution in the device under operational conditions. Combining the results of several devices with different carrier blocking properties and the results from transient EL, it was concluded trions not only exist near buffer layer but also exist in the electron transport layer. This TPQ model can also be used to explain the positive spin-1/2 PLDMR in poly(3-hexylthiophene) (P3HT) films at low temperature and in MEH-PPV films at various temperatures up to room temperature. Through quantitative analysis, TE-polaron quenching (TPQ) model is shown having the ability to explain most behaviors of the positive spin-1/2 resonance. Photocurrent detected magnetic resonance (PCDMR) studies on MEH-PPV devices revealed a novel transient resonance signal. The signal may originate from the higher concentration of deep traps near cathode. A quantitative analysis based on this assumption was carried out and found to be consistent with the experimental results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The excitation of geodesic acoustic mode flows by a resonant magnetic field and by resonant heating

Toroidal magnetohydrodynamic (MHD) simulations demonstrate that sheared poloidal flows in tokamaks can be generated by the resonant excitation of the geodesic acoustic mode (GAM). Poloidal flows are generated by two resonant excitation methods: oscillating currents in an external coil and an oscillating heat source. The coil current and the heat source oscillate in time at the local GAM frequency. The sheared poloidal flow generated by the excitation of the GAM may be useful for the suppression of plasma instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gradient-based surface nuclear magnetic resonance for groundwater investigation

In medical magnetic resonance imaging, spatial localization (imaging) is based upon the application of controlled magnetic field gradients on top of the main magnetic field to spatially modulate the frequency and/or phase of the nuclear magnetic resonance (NMR) signal across the volume of investigation. In this work, we have applied similar physical principles to produce controlled magnetic field gradients during surface NMR-based groundwater investigations. In this approach, a gradient pulse of variable amplitude or duration is applied immediately after the excitation pulse to cause predictable phase encoding of the NMR signal as a function of depth. This approach is also applicable to emerging surface NMR detection methods that use a prepolarization field with fast nonadiabatic turn-off to generate detectable NMR signals from the shallow subsurface. In this case, the gradient pulse is applied after terminating the prepolarization field and provides a heretofore unavailable means of localizing the NMR response as a function of depth. The application of gradients can also be combined with tip-angle-based modulation to yield higher imaging resolution than can be achieved through either gradient- or tip-angle-based imaging alone. We implemented this new gradient-based capability into a surface NMR gradient generation accessory that is compatible with the GMR-Flex instrument and developed surface NMR-specific forward modeling and linear inverse models. We validated the accuracy of this novel gradient-based sNMR technology using computer simulations, experiments using a small pool filled with a discrete layer of bulk water, and field experiments at well-characterized groundwater test sites along Ebey Island, WA, and Larned, KS. The gradient-based sNMR imaging observations were compared with high-resolution direct push NMR results observed at these sites. The results of computer simulations and field experiments indicate improvements in both the detection (signal-to-noise ratio) and spatial resolution of shallow subsurface water content using gradient-based surface NMR, compared with traditional surface NMR imaging methods.

Geochemistry & Geophysics↗

Mode locking and island suppression by resonant magnetic perturbations in Rutherford regime

We demonstrate in theory that tearing mode locking and magnetic island suppression by resonant magnetic perturbations (RMPs) can correspond to different states of a same dynamic system governed by the torque balance and the nonlinear island evolution in the Rutherford regime. In particular, mode locking corresponds to the exact steady state of this system. A new exact analytic solution has been obtained for such a steady state, which quantifies the dependence of the locked mode island width on RMP amplitude in different plasma regimes. Furthermore, two different branches of mode locking have been revealed with the new analytic solution and the branch with suppressed island width turns out to be unstable in general. On the other hand, the system also admits stable states of island suppression achieved through the RMP modulation of tearing mode rotational frequency. When the RMP amplitude is above a certain threshold, the island suppression is transient until the tearing mode eventually gets locked. When the RMP amplitude is below the mode locking threshold, the island can be suppressed in a steady state on time-average, along with transient oscillations in rotational frequency and island width due to the absence of mode locking.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗