Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RIGIDITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Two-chord interferometry using 3.39 {mu}m He-Ne laser on a flux-coil-generated FRC

A two-chord {lambda}{sub IR}{approx}3.39 {mu}m He-Ne laser interferometer system was developed for a flux-coil-generated field-reversed configuration to estimate the electron density and the total temperature of the field-reversed configuration (FRC) plasma. This two-chord heterodyne interferometer system consists of a single {approx}2 mW infrared He-Ne laser, a visible ({lambda}{sub vis}{approx}632.8 nm) He-Ne laser for the alignment, a 40 MHz acousto-optic modulator, photodetectors, and quadrature phase detectors. Initial measurement was performed and the measured average electron densities were 2-10x10{sup 19} m{sup -3} at two different radial positions in the midplane. A time shift in density was observed as the FRC expands radially. The time evolution of the line-averaged density agrees with the density estimated from the in situ internal magnetic probes, based on a rigid-rotor profile model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flexible spin-orbit torque devices

We report on state-of-the-art spintronic devices synthesized and fabricated directly on a flexible organic substrate. Large perpendicular magnetic anisotropy was achieved in ultrathin ferromagnetic heterostructures of Pt/Co/MgO sputtered on a non-rigid plastic substrate at room temperature. Subsequently, a full magnetic reversal of the Co was observed by exploiting the spin orbit coupling in Pt that leads to a spin accumulation at the Pt/Co interface when an in-plane current is applied. Quasi-static measurements show the potential for operating these devices at nano-second speeds. Importantly, the behavior of the devices remained unchanged under varying bending conditions (up to a bending radius of ≈ ±20–30 mm). Furthermore, the devices showed robust operation even after application of 10{sup 6} successive pulses, which is likely sufficient for many flexible applications. Thus, this work demonstrates the potential for integrating high performance spintronic devices on flexible substrates, which could lead to many applications ranging from flexible non-volatile magnetic memory to local magnetic resonance imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Selective Detection of Intermediate-Amplitude Motion by Solid-State NMR

The coexistence of rigid and mobile molecules or molecular segments abounds in biomolecular assemblies. Examples include the carbohydrate-rich cell walls of plants and intrinsically disordered proteins that contain rigid β-sheet cores. In solid-state nuclear magnetic resonance (NMR) spectroscopy, dipolar polarization transfer experiments are well suited for detecting rigid components, whereas scalar-coupling experiments are well suited for detecting highly mobile components. However, few NMR methods are available to detect the segments that undergo intermediate-amplitude fast motion. Here, we introduce two NMR experiments, a two-dimensional T 2H -filtered CP-hCH correlation and a three-dimensional J-INADEQUATE CCH correlation, to observe this intermediate-amplitude motion. Both experiments involve 1 H detection under fast magic-angle spinning (MAS). By combining 1 H transverse relaxation (T 2H ) filters with dipolar polarization transfer, we suppress the signals of both highly rigid and highly mobile species, thus revealing the signals of intermediate mobile species. 1 H detection under fast MAS is crucial for distinguishing the different motional amplitudes. Here, we demonstrate these techniques on several plant cell wall samples and show that they allow the selective detection and resolution of certain hemicellulose and pectin signals, which are usually masked by the signals of the rigid cellulose and the highly dynamic pectins in purely dipolar and scalar NMR spectra.

59 BASIC BIOLOGICAL SCIENCES↗

Design and construction of a point-contact spectroscopy rig with lateral scanning capability

The design and realization of a cryogenic rig for point-contact spectroscopy measurements in the needle-anvil configuration is presented. Thanks to the use of two piezoelectric nano-positioners, the tip can move along the vertical (z) and horizontal (x) direction and thus the rig is suitable to probe different regions of a sample in situ. Moreover, it can also form double point-contacts on different facets of a single crystal for achieving, e.g., an interferometer configuration for phase-sensitive measurements. For the later purpose, the sample holder can also host a Helmholtz coil for applying a small transverse magnetic field to the junction. A semi-rigid coaxial cable can be easily added for studying the behavior of Josephson junctions under microwave irradiation. The rig can be detached from the probe and thus used with different cryostats. The performance of this new probe has been tested in a Quantum Design PPMS system by conducting point-contact Andreev reflection measurements on Nb thin films over large areas as a function of temperature and magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Brownian motion of massive skyrmions in magnetic thin films

We report on the thermal effects on the motion of current-driven massive magnetic skyrmions. The reduced equation for the motion of skyrmion has the form of a stochastic generalized Thiele’s equation. We propose an ansatz for the magnetization texture of a non-rigid single skyrmion that depends linearly with the velocity. By using this ansatz it is found that the skyrmion mass tensor is closely related to intrinsic skyrmion parameters, such as Gilbert damping, skyrmion-charge and dissipative force. We have found an exact expression for the average drift velocity as well as the mean-square velocity of the skyrmion. The longitudinal and transverse mobility of skyrmions for small spin-velocity of electrons is also determined and found to be independent of the skyrmion mass.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spin-torsion effects in the hyperfine structure of methanol

The magnetic hyperfine structure of the non-rigid methanol molecule is investigated experimentally and theoretically. 12 hyperfine patterns are recorded using molecular beam microwave spectrometers. These patterns, along with previously recorded ones, are analyzed in an attempt to evidence the effects of the magnetic spin-torsion coupling due to the large amplitude internal rotation of the methyl group [J. E. M. Heuvel and A. Dymanus, J. Mol. Spectrosc. 47, 363 (1973)]. The theoretical approach setup to analyze the observed data accounts for this spin-torsion in addition to the familiar magnetic spin-rotation and spin-spin interactions. The theoretical approach relies on symmetry considerations to build a hyperfine coupling Hamiltonian and spin-rotation-torsion wavefunctions compatible with the Pauli exclusion principle. Although all experimental hyperfine patterns are not fully resolved, the line position analysis yields values for several parameters including one describing the spin-torsion coupling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ferromagnetic Double Perovskite Semiconductors with Tunable Properties

Abstract The authors successfully dope the magnetically silent double perovskite semiconductor Sr 2 GaSbO 6 to induce ferromagnetism and tune its bandgap, with Ga 3+ partially substituted by the magnetic trivalent cation Mn 3+ , in a rigid cation ordering with Sb 5+ . The new ferromagnetic semiconducting Sr 2 Ga 1− x Mn x SbO 6 double perovskite, which crystallizes in tetragonal symmetry (space group I 4/ m ) and has tunable ferromagnetic ordering temperature and bandgap, suggests that magnetic ion doping of double perovskites is a productive avenue toward obtaining materials for application in next‐generation oxide‐based spintronic devices.

36 MATERIALS SCIENCE↗

Magnetic Methods for Tracking Particle Motions and Temperatures within Opaque Vessels

A three year LDRD was undertaken to look at the feasibility of using magnetic sensing to determine flows within sealed vessels at high temperatures and pressures. Uniqueness proofs were developed for tracking of single magnetic particles with multiple sensors. Experiments were shown to be able to track up to 3 dipole particles undergoing rigid-body rotational motion. Temperature was wirelessly monitored using magnetic particles in static and predictable motions. Finally high-speed vibrational motion was tracked using magnetic particles. Ideas for future work include using small particles for measuring vorticity and better calibration methods for tracking multiple particles.

47 OTHER INSTRUMENTATION↗

Vacuum insulated room temperature bore horizontal cryostat for 4-Tesla superconducting magnet

4-Tesla warm bore superconducting magnet is being constructed at Bhabha Atomic Research Centre in India. The adiabatically cooled superconducting magnet will be used for corrosion and Magneto Hydro Dynamic (MHD) studies related to development of Lead Lithium Cooled Ceramic Breeder (LLCB) test blanket module (TBM). Magnet aperture is of 300 mm diameter and is accessible from both ends. Magnet is completely immersed in liquid helium bath at 4.2K. The stored magnetic energy during normal operation is 2.6 MJ. Huge amount of Lorentz forces acts on the magnet coils during operation. These forces try to axially compress the coils and cause outward radial movement of the conductor. Micro meter movement of the coils result in energy deposition due to large operating fields. This energy, albeit small, is still sufficient to cause quench in the magnet as the heat capacities at cryogenic temperatures are very low. Pre-stressing and banding of the superconducting strands help to overcome conductor movement by increasing structural rigidity. This paper describes the thermal, structural and magnetic design the superconducting solenoid magnet. (author)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrical Control of Structural and Physical Properties via Strong Spin-Orbit Interactions in Sr 2 IrO 4

Electrical control of structural and physical properties is a long-sought, but elusive goal of contemporary science and technology. We propose that a combination of strong spin-orbit interactions (SOI) and a canted antiferromagnetic Mott state is sufficient to attain that goal. The antiferromagnetic insulator Sr 2 IrO 4 provides a model system in which strong SOI lock canted Ir magnetic moments to IrO6 octahedra, causing them to rigidly rotate together. A novel coupling between an applied electrical current and the canting angle reduces the N´eel temperature and drives a large, nonlinear lattice expansion that closely tracks the magnetization, increases the electron mobility, and precipitates a unique resistive switching effect. Our studies open new avenues for understanding fundamental physics driven by strong SOI in condensed matter, and provide a new paradigm for functional materials and devices.

36 MATERIALS SCIENCE↗

Solar Modulation of {sup 2}H/{sup 1}H and {sup 3}He/{sup 4}He according to Data Obtained in the PAMELA Satellite-Borne Experiment between 2006 and 2014

Preliminary results of measurements of the solar modulation of the isotopic hydrogen and helium content in galactic cosmic rays are presented for the first time. These data were obtained between 2006 and 2014 in the PAMELA international orbital experiment via measuring the time of flight of nuclei in the Pamela scintillation telescope and via analyzing, in the multilayered calorimeter of the PAMELA magnetic spectrometer, ionization losses of nuclei whose rigidity was known from trajectory measurements and which traversed the instrument without undergoing nuclear interactions. The results of these measurements are compared with existing experimental and calculated data, which are quite scanty.

79 ASTRONOMY AND ASTROPHYSICS↗

FLARING SOLAR HALE SECTOR BOUNDARIES

The sector structure that organizes the magnetic field of the solar wind into large-scale domains has a clear pattern in the photospheric magnetic field as well. The rotation rate, 27-28.5 days, implies an effectively rigid rotation originating deeper in the solar interior than the sunspots. The photospheric magnetic field is known to be concentrated near that portion (the Hale boundary) in each solar hemisphere, where the change in magnetic sector polarity matches that between the leading and following sunspot polarities in active regions in the respective hemispheres. We report here that flares and microflares also concentrate at the Hale boundaries, implying that flux emergence and the creation of free magnetic energy in the corona also have a direct cause in the deep interior.

79 ASTRONOMY AND ASTROPHYSICS↗

New 3-D coordination polymers based on semi-rigid V-shape tetracarboxylates

Under the hydrothermal conditions, the reactions of transition-metal salts, tetracarboxylic acids and N,N′-donor ligands yielded three new coordination polymers as [Cu{sub 4}(fph){sub 2}(bpe){sub 3}(H{sub 2}O){sub 2}]·2H{sub 2}O (fph=4,4′-(hexafluoroisopropylidene)diphthalate, bpe=1,2-bis(pyridyl)ethylene) 1, [Co{sub 2}(fph)(bpa){sub 2}(H{sub 2}O){sub 2}]·3H{sub 2}O (bpa=1,2-bis(pyridyl)ethylane) 2, and [Ni(H{sub 2}O)(H{sub 2}oph)(bpa)] (oph=4,4′-oxydiphthalate) 3. X-ray single-crystal diffraction analysis revealed that the title three compounds all possess the three-dimensional (3-D) network structures. For compound 1, the fph molecules first link the Cu{sup 2+} ions into a two-dimensional (2-D) wave-like layer with a (4,4) topology. The bpe molecules act as the second linkers, extending the 2-D layers into a 3-D network. For compound 2, the fph molecules still serve as the first connectors, linking the Co{sup 2+} ions into a one-dimensional (1-D) tube-like chain. Then the bpa molecules propagate the chains into a 3-D (4,4,4)-connected network. In the formation of the 3-D network of compound 3, the oph molecule does not play a role. The bpa molecules as well as the water molecules act as a mixed bridge. Only a kind of 4-connected metal node is observed in compound 3. The magnetic properties of compounds 1–3 were investigated and all exhibit the predominant antiferromegnetic magnetic behaviors. - Graphical abstract: Structures of three semi-rigid V-shape tetracarboxylate-based coordination polymers were reported, and their magnetic properties were investigated. - Highlights: • Structures of three tetracarboxylate-based coordination polymers were reported. • Role of organic bases in metal–tetracarboxylate compounds was discussed. • Characters of V-shape and semi-rigidity for tetracarboxylate play a key role in crystal growth. • Their magnetic properties were investigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Robust cycloid crossover driven by anisotropy in the skyrmion host GaV 4 S 8

We report on the anomalous magnetization dynamics of the cycloidally modulated spin textures under the influence of uniaxial anisotropy in multiferroic GaV 4 S 8 . The temperature and field dependence of the linear ac susceptibility [$χ'_{1ω}$ (T, H)], AC magnetic loss [$χ''_{1ω}$ (T, H)], and nonlinear AC magnetic response [$M_{3ω}$ (T, H)] are examined across the magnetic phase diagram in the frequency range f = 10 - 10 000 Hz. According to recent theory, skyrmion vortices under axial crystal symmetry are confined along specific orientations, resulting in enhanced robustness against oblique magnetic fields and altered spin dynamics. We characterize the magnetic response of each spin texture and find that the dynamic rigidity of the Néel skyrmion lattice appears enhanced compared to Bloch-type skyrmions in cubic systems, even in the multidomain state. Anomalous M 3 ω and strong dissipation emerge over the same phase regime where strong variations in the cycloid pitch were observed on lowering temperature in recent small-angle neutron-scattering experiments [White et al., Phys. Rev. B 97, 020401(R) (2018)]. Here, we show that strong anisotropy also drives an extended crossover of the zero-field cycloid texture in GaV 4 S 8 . The frequency dependence of these dynamic signatures is consistent with that of a robust anharmonic spin texture exhibiting a correlated domain arrangement. The results underpin the essential role of magnetic anisotropy in enhancing the rigidity of topological spin textures for diverse applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SDO OBSERVATIONS OF MAGNETIC RECONNECTION AT CORONAL HOLE BOUNDARIES

With the observations from the Atmospheric Imaging Assembly and the Helioseismic and Magnetic Imager on board the Solar Dynamics Observatory, we investigate the coronal hole boundaries (CHBs) of an equatorial extension of the polar coronal hole. At the CHBs, many extreme-ultraviolet jets, which appear to be the signatures of magnetic reconnection, are observed in the 193 A images, and some jets occur repetitively at the same sites. The evolution of the jets is associated with the emergence and cancellation of magnetic fields. We note that both the east and west CHBs shift westward, and the shift velocities are close to the velocities of rigid rotation compared with those of the photospheric differential rotation. This indicates that magnetic reconnection at CHBs results in the evolution of CHBs and maintains the rigid rotation of coronal holes.

79 ASTRONOMY AND ASTROPHYSICS↗

Mechanical analysis and test results of 4-coil superconducting helical solenoid model

Novel configurations of helical superconducting magnets for muon beam 6D phase space cooling channels and demonstration experiments are being designed at Fermilab. Operating as needed for the beam cooling in a cryogenic environment, the helical solenoid generates longitudinal and transverse magnetic fields; meanwhile, large Lorentz forces are produced, so rigid coil support structures need to be designed. A short model of a helical solenoid (HS), consisting of four coils and supporting structures, was designed, built and tested at Fermilab. The magnetic and mechanical designs were analyzed using TOSCA and ANSYS. The supporting structures were fabricated and assembled using SSC NbTi cable. Strain gauges were utilized to monitor the deformation of the structures due to both thermal contraction and Lorentz forces. The superconducting coils were trained during the test. The model should prove the design concept, fabrication technology, and the magnet system performance.

43 PARTICLE ACCELERATORS↗

Thermal equilibrium of non-neutral plasma in dipole magnetic field

Self-organization of a long-lived structure is one of the remarkable characteristics of macroscopic systems governed by long-range interactions. In a homogeneous magnetic field, a non-neutral plasma creates a “thermal equilibrium,” which is a Boltzmann distribution on a rigidly rotating frame. Here, we study how a non-neutral plasma self-organizes in inhomogeneous magnetic field; as a typical system, we consider a dipole magnetic field. In this generalized setting, the plasma exhibits its fundamental mechanism that determines the relaxed state. The scale hierarchy of adiabatic invariants is the determinant; the Boltzmann distribution under the topological constraint by the robust adiabatic invariants (hence, the homogeneous distribution with respect to the fragile invariant) is the relevant relaxed state, which turns out to be a rigidly rotating clump of particles (just same as in a homogeneous magnetic field), while the density is no longer homogeneous.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A multimodality segmentation framework for automatic target delineation in head and neck radiotherapy

Purpose: To develop an automatic segmentation algorithm integrating imaging information from computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI) to delineate target volume in head and neck cancer radiotherapy. Methods: Eleven patients with unresectable disease at the tonsil or base of tongue who underwent MRI, CT, and PET/CT within two months before the start of radiotherapy or chemoradiotherapy were recruited for the study. For each patient, PET/CT and T1-weighted contrast MRI scans were first registered to the planning CT using deformable and rigid registration, respectively, to resample the PET and magnetic resonance (MR) images to the planning CT space. A binary mask was manually defined to identify the tumor area. The resampled PET and MR images, the planning CT image, and the binary mask were fed into the automatic segmentation algorithm for target delineation. The algorithm was based on a multichannel Gaussian mixture model and solved using an expectation–maximization algorithm with Markov random fields. To evaluate the algorithm, we compared the multichannel autosegmentation with an autosegmentation method using only PET images. The physician-defined gross tumor volume (GTV) was used as the “ground truth” for quantitative evaluation. Results: The median multichannel segmented GTV of the primary tumor was 15.7 cm{sup 3} (range, 6.6–44.3 cm{sup 3}), while the PET segmented GTV was 10.2 cm{sup 3} (range, 2.8–45.1 cm{sup 3}). The median physician-defined GTV was 22.1 cm{sup 3} (range, 4.2–38.4 cm{sup 3}). The median difference between the multichannel segmented and physician-defined GTVs was −10.7%, not showing a statistically significant difference (p-value = 0.43). However, the median difference between the PET segmented and physician-defined GTVs was −19.2%, showing a statistically significant difference (p-value =0.0037). The median Dice similarity coefficient between the multichannel segmented and physician-defined GTVs was 0.75 (range, 0.55–0.84), and the median sensitivity and positive predictive value between them were 0.76 and 0.81, respectively. Conclusions: The authors developed an automated multimodality segmentation algorithm for tumor volume delineation and validated this algorithm for head and neck cancer radiotherapy. The multichannel segmented GTV agreed well with the physician-defined GTV. The authors expect that their algorithm will improve the accuracy and consistency in target definition for radiotherapy.

60 APPLIED LIFE SCIENCES↗