Non-Intrusive Characterization of the Wear of the HERMeS Thruster Using Optical Emission Spectroscopy

The Hall Effect Rocket with Magnetic Shielding (HERMeS) is a 12.5 kW Hall thrusterelectric propulsion string that has been in development by NASA Glenn Research Center(GRC) and NASA JPL since 2012. Due to the magnetically shielded design, service life-limiting erosion of the boron nitride discharge has been virtually eliminated. The innerfront pole cover (IFPC) has now been identied as the component dening erosion-basedservice life. Optical emission spectroscopy (OES) is used as an in-situ diagnostic to measurerelative erosion trends during operation of the HERMeS thruster during a series of shortduration wear tests. Erosion trends obtained from the OES data will be compared totraditional erosion data measured with a non-contact prolometer.

hall thruster

Non-Intrusive Characterization of the Wear of the HERMeS Thruster Using Optical Emission Spectroscopy

The Hall Effect Rocket with Magnetic Shielding (HERMeS) is a 12.5 kW Hall thruster electric propulsion string that has been in development by NASA Glenn Research Center(GRC) and NASA JPL since 2012. Due to the magnetically shielded design, service life-limiting erosion of the boron nitride discharge has been virtually eliminated. The inner front pole cover (IFPC) has now been identified as the component defining erosion-based service life. Optical emission spectroscopy (OES) is used as an in-situ diagnostic to measure relative erosion trends during operation of the HERMeS thruster during a series of short duration wear tests. Erosion trends obtained from the OES data will be compared to traditional erosion data measured with a non-contact profilometer.

Gray, Timothy G.

Property and microstructural nonuniformity in the yttrium-barium-copper-oxide superconductor determined from electrical, magnetic, and ultrasonic measurements

The purpose of this dissertation was the following: (1) to characterize the effect of pore fraction on a comprehensive set of electrical and magnetic properties for the yttrium-barium-copper-oxide (YBCO) high temperature ceramic superconductor; and (2) to determine the viability of using a room-temperature, nondestructive characterization method to aid in the prediction of superconducting (cryogenic) properties. The latter involved correlating ultrasonic velocity measurements at room temperature with property-affecting pore fraction and oxygen content variations. The use of ultrasonic velocity for estimating pore fraction in YBCO is presented, and other polycrystalline materials are reviewed, modeled, and statistically analyzed. This provides the basis for using ultrasonic velocity to interrogate microstructure. The effect of pore fraction (0.10-0.25) on superconductor properties of YBCO samples was characterized. Spatial (within-sample) variations in microstructure and superconductor properties were investigated, and the effect of oxygen content on elastic behavior was examined. Experimental methods used included a.c. susceptibility, electrical, and ultrasonic velocity measurements. Superconductor properties measured included transition temperature, magnetic transition width, transport and magnetic critical current density, magnetic shielding, a.c. loss, and sharpness of the voltage-current characteristics. An ultrasonic velocity image constructed from measurements at 1mm increments across a YBCO sample revealed microstructural variations that correlated with variations in magnetic shielding and a.c. loss behavior. Destructive examination using quantitative image analysis revealed pore fraction to be the varying microstructural feature.

Roth, Don J.

Long Duration Wear Test of the NASA HERMeS Hall Thruster

The NASA Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5-kW Hall thruster is the subject of extensive technology maturation by NASA GRC and JPL in preparation for development into a flight propulsion system. As part of this on-going effort, a series of three wear tests have been conducted to identify erosion phenomena and the accompanying failure modes as well as to validate service-life models for magnetically-shielded thrusters. This paper presents an overview and summary of the results obtained over the first 1715 hours of the third wear test, which has the overall goal of serving as a pathfinder to identify and correct design or facility issues prior to the flight qualification campaign. Overall, negligible changes in performance and stability are observed as a function of operating time as well as relative to previous wear tests. Erosion of the inner and outer front pole covers is shown to vary by 76-300 percent as a function of discharge voltage and by up to 40 percent as a function of magnetic field strength. Shifting the cathode position upstream relative to the pole covers is shown to reduce keeper erosion rates by 84 percent, which supports this approach for mitigating the elevated keeper wear observed during previous wear tests.

Frieman, Jason D.

Long Duration Wear Test of the NASA HERMeS Hall Thruster

The NASA Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5-kW Hall thruster is the subject of extensive technology maturation by NASA GRC and JPL in preparation for development into a flight propulsion system. As part of this on-going effort, a series of three wear tests have been conducted to identify erosion phenomena and the accompanying failure modes as well as to validate service-life models for magnetically-shielded thrusters. This paper presents an overview and summary of the results obtained over the first 1715 hours of the third wear test, which has the overall goal of serving as a pathfinder to identify and correct design or facility issues prior to the flight qualification campaign. Overall, negligible changes in performance and stability are observed as a function of operating time as well as relative to previous wear tests. Erosion of the inner and outer front pole covers is shown to vary by 76-300 percent as a function of discharge voltage and by up to 40 percent as a function of magnetic field strength. Shifting the cathode position upstream relative to the pole covers is shown to reduce keeper erosion rates by 84 percent, which supports this approach for mitigating the elevated keeper wear observed during previous wear tests.

Frieman, Jason D.

Long Duration Wear Test of the NASA HERMeS Hall Thruster

The NASA Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5-kW Hall thruster is the subject of extensive technology maturation by NASA GRC (Glenn Research Center) and JPL (Jet Propulsion Laboratory) in preparation for development into a flight propulsion system. As part of this on-going effort, a series of three wear tests have been conducted to identify erosion phenomena and the accompanying failure modes as well as to validate service-life models for magnetically-shielded thrusters. This paper presents an overview and summary of the results obtained over the first 1715 hours of the third wear test, which has the overall goal of serving as a pathfinder to identify and correct design or facility issues prior to the flight qualification campaign. Overall, negligible changes in performance and stability are observed as a function of operating time as well as relative to previous wear tests. Erosion of the inner and outer front pole covers is shown to vary by 76-300 percent as a function of discharge voltage and by up to 40 percent as a function of magnetic field strength. Shifting the cathode position upstream relative to the pole covers is shown to reduce keeper erosion rates by 84 percent, which supports this approach for mitigating the elevated keeper wear observed during previous wear tests.

Frieman, Jason D.

Completion of the Long Duration Wear Test of the NASA HERMeS Hall Thruster

The NASA Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5-kW Hall thruster has been the subject of extensive technology maturation by NASA GRC and JPL in preparation for development into a flight propulsion system. As part of this effort, a series of wear tests have been conducted to identify erosion phenomena and the accompanying failure modes as well as to validate service-life models for magnetically-shielded thrusters. This work presents a summary of the results obtained during the Long Duration Wear Test (LDWT), which was the third in this wear test series. The LDWT accumulated approximately 3,570 hours of operation and had the overall goal to identify and correct design or facility issues prior to the flight qualification campaign. Thruster performance, stability, and plume properties were invariant throughout the duration of the LDWT and consistent with measurements acquired during previous HERMeS performance and wear characterizations. Average erosion rates of a carbon-carbon composite pole cover were found to match those measured with graphite to within the empirical uncertainty while the previously observed time-dependence of pole cover erosion rates was linked to changes in pole cover roughness. Azimuthal variations in keeper wear rate were observed including deposition on one of the azimuthal-facing sides of the keeper mask. This strongly suggests the presence of an azimuthal component in the process driving keeper erosion.

Frieman, Jason D.

Completion of the Long Duration Wear Test of the NASA HERMeS Hall Thruster

The NASA Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5-kW Hall thruster has been the subject of extensive technology maturation by NASA GRC and JPL in preparation for development into a flight propulsion system. As part of this effort, a series of wear tests have been conducted to identify erosion phenomena and the accompanying failure modes as well as to validate service-life models for magnetically-shielded thrusters. This work presents a summary of the results obtained during the Long Duration Wear Test (LDWT), which was the third in this wear test series. The LDWT accumulated approximately 3,570 hours of operation and had the overall goal to identify and correct design or facility issues prior to the flight qualification campaign. Thruster performance, stability, and plume properties were invariant throughout the duration of the LDWT and consistent with measurements acquired during previous HERMeS performance and wear characterizations. Average erosion rates of a carbon-carbon composite pole cover were found to match those measured with graphite to within the empirical uncertainty while the previously observed time-dependence of pole cover erosion rates was linked to changes in pole cover roughness. Azimuthal variations in keeper wear rate were observed including deposition on one of the azimuthal-facing sides of the keeper mask. This strongly suggests the presence of an azimuthal component in the process driving keeper erosion.

Frieman, Jason D.

Completion of the Long Duration Wear Test of the NASA HERMeS Hall Thruster

The NASA Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5-kW Hall thruster has been the subject of extensive technology maturation by NASA GRC and JPL in preparation for development into a flight propulsion system. As part of this effort, a series of wear tests have been conducted to identify erosion phenomena and the accompanying failure modes as well as to validate service-life models for magnetically-shielded thrusters. This work presents a summary of the results obtained during the Long Duration Wear Test (LDWT), which was the third in this wear test series. The LDWT accumulated approximately 3,570 hours of operation and had the overall goal to identify and correct design or facility issues prior to the flight qualification campaign. Thruster performance, stability, and plume properties were invariant throughout the duration of the LDWT and consistent with measurements acquired during previous HERMeS performance and wear characterizations. Average erosion rates of a carbon-carbon composite pole cover were found to match those measured with graphite to within the empirical uncertainty while the previously observed time-dependence of pole cover erosion rates was linked to changes in pole cover roughness. Azimuthal variations in keeper wear rate were observed including deposition on one of the azimuthal-facing sides of the keeper mask. This strongly suggests the presence of an azimuthal component in the process driving keeper erosion.

Jason David Frieman

Optical Characterization of Component Wear and Near-Field Plasma of the Hermes Thruster

Optical emission spectral (OES) data are presented which correlate trends in sputtered species and the near-field plasma with the Hall-Effect Rocket with Magnetic Shielding (HERMeS) thruster operating condition. The relative density of singly-ionized xenon (Xe II) is estimated using a collisional-radiative model. OES data were collected at three radial and several axial locations downstream of the thruster's exit plane. These data were deconvolved to show the structure for the near-field plasma as a function of thruster operating condition. The magnetic field is shown to have a much greater affect on plasma structure than the discharge voltage with the primary ionization/acceleration zone boundary being similar for all nominal operating voltages at constant power. OES measurement of sputtered boron shows that the HERMeS thruster is magnetically shielded across its operating envelope. Preliminary assessment of carbon sputtered from the keeper face suggest it increases significantly with operating voltage, but the uncertainty associated with these measurements is very high.

Electric Propulsion

Quantifying trapped magnetic vortex losses in niobium resonators at mK temperatures

Trapped magnetic vortices in niobium introduce microwave losses that degrade the performance of superconducting resonators. While such losses have been extensively studied above 1 K, we report here their direct quantification in the millikelvin and low-photon regime relevant to quantum devices. Using a high-quality factor 3D niobium cavity cooled through its superconducting transition in controlled magnetic fields, we isolate vortex-induced losses and find the resistive component of the sensitivity to trapped flux S to be approximately 2 n Ω/mG at 10 mK and 6 GHz. The decay rate is initially dominated by two-level system (TLS) losses from the native niobium pentoxide, with vortex-induced degradation of T 1 occurring above B trap ∼ 50 mG. In the absence of the oxide, even 10 mG of trapped flux limits performance, Q 0 ∼ 10 10 , or T 1 ∼ 350 ms, underscoring the need for stringent magnetic shielding. The resistive sensitivity, S, decreases with temperature and remains largely field-independent, whereas the reactive component, S′, exhibits a maximum near 0.8 K. These behaviors are well modeled within the Coffey–Clem framework in the zero-creep limit, under the assumption that vortex pinning is enhanced by thermally activated processes. Our results suggest that niobium-based transmon qubits can tolerate vortex-induced dissipation at trapped field levels up to several hundred mG, but achieving long coherence times still requires careful magnetic shielding to suppress lower-field losses from other mechanisms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Quantifying Trapped Magnetic Vortex Losses in Niobium Resonators at mK Temperatures

Trapped magnetic vortices in niobium introduce microwave losses that degrade the performance of superconducting resonators. While such losses have been extensively studied above 1 K, we report here their direct quantification in the millikelvin and low-photon regime relevant to quantum devices. Using a high-quality factor 3D niobium cavity cooled through its superconducting transition in controlled magnetic fields, we isolate vortex-induced losses and find the resistive component of the sensitivity to trapped flux S to be approximately 2 nOhm/mG at 10 mK and 6 GHz. The decay rate is initially dominated by two-level system (TLS) losses from the native niobium pentoxide, with vortex-induced degradation of T1 occurring above Btrap~50 mG. In the absence of the oxide, even 10 mG of trapped flux limits performance, Q0 ~ 1010, or T1 ~350 ms, underscoring the need for stringent magnetic shielding. The resistive sensitivity, S, decreases with temperature and remains largely field-independent, whereas the reactive component, S , exhibits a maximum near 0.8 K. These behaviors are well modeled within the Coffey Clem framework in the zero-creep limit, under the assumption that vortex pinning is enhanced by thermally activated processes. Our results suggest that niobium-based transmon qubits can tolerate vortex-induced dissipation at trapped field levels up to several hundred mG, but achieving long coherence times still requires careful magnetic shielding to suppress lower-field losses from other mechanisms

Bafia, Daniel P. [Fermilab]

The Low Temperature Microgravity Physics Experiments Project

The Low Temperature Microgravity Physics Facility (LTMPF) is being developed by NASA to provide long duration low temperature and microgravity environment on the International Space Station (ISS) for performing fundamental physics investigations. Currently, six experiments have been selected for flight definition studies. More will be selected in a two-year cycle, through NASA Research Announcement. This program is managed under the Low Temperature Microgravity Physics Experiments Project Office at the Jet Propulsion Laboratory. The facility is being designed to launch and returned to earth on a variety of vehicles including the HII-A and the space shuttle. On orbit, the facility will be connected to the Exposed Facility on the Japanese Experiment Module, Kibo. Features of the facility include a cryostat capable of maintaining super-fluid helium at a temperature of 1.4 K for 5 months, resistance thermometer bridges, multi-stage thermal isolation system, thermometers capable of pico-Kelvin resolution, DC SQUID magnetometers, passive vibration isolation, and magnetic shields with a shielding factor of 80dB. The electronics and software architecture incorporates two VME buses run using the VxWorks operating system. Technically challenging areas in the design effort include the following: 1) A long cryogen life that survives several launch and test cycles without the need to replace support straps for the helium tank. 2) The minimization of heat generation in the sample stage caused by launch vibration 3) The design of compact and lightweight DC SQUID electronics. 4) The minimization of RF interference for the measurement of heat at pico-Watt level. 5) Light weighting of the magnetic shields. 6) Implementation of a modular and flexible electronics and software architecture. The first launch is scheduled for mid-2003, on an H-IIA Rocket Transfer Vehicle, out of the Tanegashima Space Center of Japan. Two identical facilities will be built. While one facility is onboard the ISS, the other is re-integrated on the ground with new experiments. When the cryogen of the facility in space are exhausted, it will be swapped with the other facility with the new experiment. A total of 20 science missions are envisioned over the next 20 years.

Holmes, Warren

A Compact, Modular Package for Superconducting Bolometer Arrays

As bolometer arrays grow to ever-larger formats, packaging becomes a more critical engineering issue. We have designed a detector package to house a superconducting bolometer array, SQUID multiplexers, bias and filtering circuitry, and electrical connectors. The package includes an optical filter, magnetic shielding, and has well-defined thermal and mechanical interfaces. An early version of this package has been used successfully in the GISMO 2mm camera, a 128-pixel camera operating at a base temperature of 270mK. A more advanced package permits operation at lower temperatures by providing direct heat sinking to the SQUIDS and bias resistors, which generate the bulk of the dissipation in the package. Standard electrical connectors provide reliable contact while enabling quick installation and removal of the package. We describe how the design compensates for differing thermal expansions, allows heat sinking of the bolometer array, and features magnetic shielding in critical areas. We highlight the performance of this detector package and describe its scalability to 1280-pixel arrays in the near future.

Benford, D.

Wear Testing of the HERMeS Thruster

The Hall-Effect Rocket with Magnetic Shielding (HERMeS) thruster is being developed and tested at NASA GRC and NASA JPL through support of the Space Technology Mission Directorate (STMD) as primary propulsion for the Asteroid Rendezvous and Redirect Mission (ARRM). This thruster is advancing the state of the art of hall-effect thrusters (HETs) and is intended to serve as a precursor to higher power systems for human interplanetary exploration. The HERMeS Thruster Demonstration Unit One (TDU-1) has entered a 2000-hour wear test campaign at NASA GRC and has completed the first three of four test segments totaling 728 hours of operation. This is the first test of a NASA-designed magnetically shielded thruster to extend beyond 300 hours of continuous operation.

Thruster

Performance of the 12.5-kW Advanced Electric Propulsion System Engineering Test Unit Hall Thruster

This work presents a summary of the performance test campaign of the 12.5 kW Advanced Electric Propulsion System (AEPS) Engineering Test Unit 2 (ETU-2) thruster produced by Aerojet Rocketdyne. This test campaign had three major goals: to assess design compliance with thruster requirements, provide a comparison to the previously-tested NASA Hall Effect Rocket with Magnet Shielding (HERMeS) Technology Demonstration Units (TDUs) from which the AEPS ETU design was derived, and support AEPS application on the Power and Propulsion Element (PPE). Assessments of ETU-2 performance were conducted at discharge powers of 2.6 to 13.1 kW, which encompasses the original AEPS throttle conditions as well as those most relevant for AEPS application on PPE. The results from the test campaign indicate that ETU-2 performance meets or exceeds all AEPS thruster performance requirements and matches the values and trends previously measured with the HERMeS TDUs. In addition, similar to the HERMeS TDUs, ETU-2 performance showed minimal variation over approximately 1636 h of operating time due to the incorporation of magnetic shielding. Taken together, these results show that the AEPS design is successfully replicating the performance of the HERMeS TDUs to within the empirical uncertainty and meeting its performance requirements as the design progresses to its Critical Design Review.

HERMeS

Performance of the 12.5-kW Advanced Electric Propulsion System Engineering Test Unit Hall Thruster

This work presents a summary of the performance test campaign of the 12.5 kW Advanced Electric Propulsion System (AEPS) Engineering Test Unit 2 (ETU-2) thruster produced by Aerojet Rocketdyne. This test campaign had three major goals: to assess design compliance with thruster requirements, provide a comparison to the previously-tested NASA Hall Effect Rocket with Magnet Shielding (HERMeS) Technology Demonstration Units (TDUs) from which the AEPS ETU design was derived, and support AEPS application on the Power and Propulsion Element (PPE). Assessments of ETU-2 performance were conducted at discharge powers of 2.6 to 13.1 kW, which encompasses the original AEPS throttle conditions as well as those most relevant for AEPS application on PPE. The results from the test campaign indicate that ETU-2 performance meets or exceeds all AEPS thruster performance requirements and matches the values and trends previously measured with the HERMeS TDUs. In addition, similar to the HERMeS TDUs, ETU-2 performance showed minimal variation over approximately 1636 h of operating time due to the incorporation of magnetic shielding. Taken together, these results show that the AEPS design is successfully replicating the performance of the HERMeS TDUs to within the empirical uncertainty and meeting its performance requirements as the design progresses to its Critical Design Review.

Jason D Frieman

A PdMn Based High Resolution Thermometer for the Temperature Range of 0.7-1 K

Experiments Along the Coexistence near Tricriticality (EXACT) will test exact predictions made by Renormalization Group theory by mapping the phase diagram of liquid He-3 and He-4 mixtures at the tricritical point, Tcp=0.867 K. A PdMn based High Resolution Thermometer (HRT) will be utilized by EXACT to make accurate measurements with a resolution that has never been attained for the temperature range 0.7-1 K. The basic design of this mini high resolution thermometer comprises a sensing element whose magnetic susceptibility changes with temperature, a thermal connector, magnetic shielding, and some permanent magnets to apply a constant magnetic field. In this study, we will quantitatively determine the resolution of possible sensing element candidates of 0.15%, 0.20%, and 0.25% ppm Mn and compare them with an annealed group of PdMn with the corresponding concentrations to see how this processing technique affects sensitivity.

Koo, Peter K.