Search NASA⌕ Search

SEARCH · Search NASA

Results for “MASS SPECTROMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Interlaboratory Study for Characterizing Monoclonal Antibodies by Top-Down and Middle-Down Mass Spectrometry

The Consortium for Top-Down Proteomics (www.topdownproteomics.org) launched the present study to assess the state of top-down mass spectrometry (TD MS) and middle-down mass spectrometry (MD MS) for characterizing monoclonal antibody (mAb) primary structures, including their modifications. To meet the needs of the rapidly growing therapeutic antibody market, it is important to develop analytical strategies to characterize the heterogeneity of a therapeutic product’s primary structure reliably and reproducibly. The major objective of the present study was to determine whether current TD/MD MS technologies and protocols can add value to the more commonly employed bottom-up approaches, such as confirming protein integrity, sequencing variable domains, ruling out artefacts, and revealing modifications and their locations. A panel of three mAbs was selected and centrally provided to twenty laboratories worldwide for the analysis: Sigma mAb standard (SiLuLite), NIST mAb standard, and the therapeutic mAb Herceptin (trastuzumab). A variety of different MS instrument platforms and ion dissociation techniques were employed. Overall, the present study confirms that MD/TD MS strategies are valuable and readily available tools in laboratories worldwide. They provide complementary information to the bottom-up approach and can add unique information, which may be crucial for comprehensive mAb characterization. The current limitations, as well as possible solutions to overcome them, are also outlined. One of the limitations revealed by the results of the present study is that the expert knowledge in both experiment and data analysis is indispensable to practice TD/MD MS, but the number of TD/MD MS experts is still very low.

59 BASIC BIOLOGICAL SCIENCES↗

Carbon nanotube substrates enhance SARS-CoV-2 spike protein ion yields in matrix-assisted laser desorption–ionization mass spectrometry

Nanostructured surfaces enhance ion yields in matrix-assisted laser desorption–ionization mass spectrometry (MALDI-MS). The spike protein complex, S1, is one fingerprint signature of Sars-CoV-2 with a mass of 75 kDa. Here, we show that MALDI-MS yields of Sars-CoV-2 spike protein ions in the 100 kDa range are enhanced 50-fold when the matrix–analyte solution is placed on substrates that are coated with a dense forest of multi-walled carbon nanotubes, compared to yields from uncoated substrates. Nanostructured substrates can support the development of mass spectrometry techniques for sensitive pathogen detection and environmental monitoring.

60 APPLIED LIFE SCIENCES↗

Accurate determination of genotypic variance of cell wall characteristics of a Populus trichocarpa pedigree using high-throughput pyrolysis-molecular beam mass spectrometry

Abstract Background Pyrolysis-molecular beam mass spectrometry (py-MBMS) analysis of a pedigree of Populus trichocarpa was performed to study the phenotypic plasticity and heritability of lignin content and lignin monomer composition. Instrumental and microspatial environmental variability were observed in the spectral features and corrected to reveal underlying genetic variance of biomass composition. Results Lignin-derived ions (including m/z 124, 154, 168, 194, 210 and others) were highly impacted by microspatial environmental variation which demonstrates phenotypic plasticity of lignin composition in Populus trichocarpa biomass. Broad-sense heritability of lignin composition after correcting for microspatial and instrumental variation was determined to be H 2 = 0.56 based on py-MBMS ions known to derive from lignin. Heritability of lignin monomeric syringyl/guaiacyl ratio ( S / G ) was H 2 = 0.81. Broad-sense heritability was also high (up to H 2 = 0.79) for ions derived from other components of the biomass including phenolics (e.g., salicylates) and C5 sugars (e.g., xylose). Lignin and phenolic ion abundances were primarily driven by maternal effects, and paternal effects were either similar or stronger for the most heritable carbohydrate-derived ions. Conclusions We have shown that many biopolymer-derived ions from py-MBMS show substantial phenotypic plasticity in response to microenvironmental variation in plantations. Nevertheless, broad-sense heritability for biomass composition can be quite high after correcting for spatial environmental variation. This work outlines the importance in accounting for instrumental and microspatial environmental variation in biomass composition data for applications in heritability measurements and genomic selection for breeding poplar for renewable fuels and materials.

09 BIOMASS FUELS↗

Novel principal component analysis tool based on python for analysis of complex spectra of time-of-flight secondary ion mass spectrometry

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a powerful surface analysis tool, which can simultaneously provide elemental, isotopic, and molecular information with part per million (ppm) sensitivity. However, each spectrum may be composed of hundreds of ion signals, which makes the spectra data complex. Principal component analysis (PCA) is a multivariate analysis technique that has been widely used to figure out the variances among samples in ToF-SIMS spectra data analysis and is showing great success in the explanation of complex ToF-SIMS spectra. So far, several software tools have been developed for PCA of ToF-SIMS spectra; however, none of them are freely available. Such a situation leads to some difficulties in extending applications of PCA to various research fields. More importantly, it has long been challenging for common researchers to understand PCA plots and extract chemical differences among samples. In this work, we developed a new and flexible software tool (named “advanced spectra pca toolbox”) based on python for PCA of complex ToF-SIMS spectra along with an easy-to-read manual. It can generate data analysis reports automatically to explain chemical differences among samples, allowing less experienced researchers to easily understand tricky PCA results. Moreover, it is expandable and compatible with artificial intelligence/machine learning functions. Pure goethite and different lignin adsorbed goethite samples were used as a model system to demonstrate our new software tool, proving that our software tool can be readily used in complex spectra data processing. Our new software tool is open-source, convenient, flexible, and expandable. We expect this open-source tool will benefit the ToF-SIMS community.

47 OTHER INSTRUMENTATION↗

Algorithms and file structures to enhance software workflows for ion mobility mass spectrometry (IM-MS): CRADA 410 (Final Report)

This document is the final report for CRADA 410 (Project No. 72496). The purpose of this project was supporting customizations of algorithms and raw data file structures to enhance software workflows for liquid chromatography (LC), mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS)-based metabolite characterization. PNNL worked with Agilent to evaluate and improve the integration of ion mobility into existing MS data analysis methods of Agilent software tools. The project augmented PNNL’s capabilities to analyze complex omics samples. These capabilities are directly beneficial to DOE and PNNL efforts to characterize and analyze compounds in microbial and plant communities. The project assisted Agilent in further developing improved instrument-software solutions combining ion mobility with mass spectrometry for widespread applications in life sciences and other fields.

97 MATHEMATICS AND COMPUTING↗

Product specific thermal degradation kinetics of bisphenol F epoxy in inert and oxidative atmospheres using evolved gas analysis–mass spectrometry

Knowledge of the degradation kinetics for polymer materials is important for understanding thermal stability. In this study, evolved gas analysis–mass spectrometry and pyrolysis gas-chromatography-mass spectrometry were evaluated for the potential to deliver additional insight into thermal degradation kinetics of diglycidal ether of bisphenol F (DGEBF) epoxy thermoset under inert and oxidative atmospheres. Degradation products of selected precursor ions were evaluated for their uniqueness to the specific precursor using extracted ion thermographs. Unique mass peaks, solely attributed to a single reaction pathway of a specific product, were determined from extracted ion thermographs and used to determine both activation energy (E a ) and pre-exponential factors for the specific primary reaction pathways. These primary reaction pathways for DGEBF epoxy degradation were then evaluated in the context of transition state theory (TST) and related transition state enthalpies (ΔH ‡ ) and entropies (ΔS ‡ ) of activation to further elucidate the degradation process. It was determined under pyrolysis conditions, as suggested by the E a , the formation of bisphenol F monomer was the rate-limiting step toward the formation of xanthene and phenol. In contrast, under thermo-oxidative conditions, reactions involving oxygen containing species were identified as the rate-limiting step for all observed products based on the large negative ΔS ‡ calculated from TST. This work demonstrates a powerful combination of technique and theory that can provide new insight into the degradation of polymer materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microscale mass spectrometry systems, devices and related methods

Mass spectrometry systems or assemblies therefore include an ionizer that includes at least one planar conductor, a mass analyzer with a planar electrode assembly, and a detector comprising at least one planar conductor. The ionizer, the mass analyzer and the detector are attached together in a compact stack assembly. The stack assembly has a perimeter that bounds an area that is between about 0.01 mm 2 to about 25 cm 2 and the stack assembly has a thickness that is between about 0.1 mm to about 25 mm.

47 OTHER INSTRUMENTATION↗

Molecular beam mass spectrometry measurements of vibrationally excited N 2 in the effluent of an atmospheric plasma jet: a comparison with a state-to-state kinetic model

Vibrationally excited N 2 molecules are suggested to be one of the possible key species responsible for the observed synergistic effects in plasma catalysis for NH 3 synthesis. To assess the impact of vibrationally excited species in plasma-catalysis, quantitative measurements near interfaces are required, which remains challenging. In this letter, we report spatially resolved measurements of vibrationally excited N 2 in the effluent of an atmospheric pressure plasma jet by molecular beam mass spectrometry (MBMS). The mass spectrometry signals as a function of electron energy of the ionizer were fitted with the effective electron-impact ionization cross section of N 2 (v) considering the vibrational distribution function as determined by a detailed vibrational level resolved plasma kinetic calculation. Here, the reported method presented in this letter shows the capability of MBMS to measure vibrationally excited species of N 2 near interfaces when the vibrational distribution function is known or assumed and shows excellent agreement with state-to-state kinetic models of N 2 (v).

42 ENGINEERING↗

Evaluating inkjet dispenser/liquid vortex capture-mass spectrometry for single-cell metabolomics in Hep G2 steatosis caused by tamoxifen

Single-cell mass spectrometry (MS) is advancing our understanding of metabolic pathways in heterogeneous cell populations; however, many techniques are slow or require disruptive sample preparations. This study evaluated coupling a modified HP D100 single-cell inkjet dispenser with liquid vortex capture-mass spectrometry (D100/LVC-MS). The D100 is a single-cell inkjet dispenser capable of titrating solutions and isolating single cells via disposable cassettes equipped with microfluidic channels and an impedance sensor. The LVC-MS enables high-throughput capture, lysis, and ionization of analytes for mass spectrometric analysis. The D100/LVC-MS system was characterized through titration and single-cell experiments. Propranolol titration demonstrated linearity across a broad concentration range using the D100/LVC-MS system. Additionally, Hep G2 hepatocarcinoma cells and Chlamydomonas reinhardtii algae were used to showcase the D100’s high-throughput or low-buffer-volume single-cell dispensing strategies. The D100/LVC-MS system’s performance was validated by evaluating tamoxifen-induced steatosis in Hep G2 cells. Tamoxifen, associated with nonalcoholic fatty liver disease in breast cancer patients following long-term use, was tested in Hep G2 cells at 20 µM for 72 h against DMSO-treated controls. High-throughput analysis of 500 cells per condition, completed in 25 min per run, demonstrated the system’s efficiency. The D100/LVC-MS system simultaneously quantified tamoxifen and measured triglycerides and phosphatidylcholines. Triglycerides were upregulated in the tamoxifen-treated cells and the results indicated two distinct cell populations, differing in tamoxifen and phosphatidylcholines levels, suggesting heterogeneity within the treated population. In conclusion, these findings highlight the D100/LVC-MS system as a cost-effective, high-throughput platform for single-cell metabolomics and lipidomics, with significant potential for evaluating metabolic alterations.

Chromatography↗

Development and investigation of efficient resonance ionization mass spectrometry schemes of gadolinium

Resonance ionization mass spectrometry of gadolinium can be used for nuclear forensics and to further the understanding of stellar nucleosynthesis but has been used only a handful of times due to the high laser power required and interference from non-resonant ionization of molecules of other elements. Herein we present the development of two novel resonance ionization spectroscopy schemes for gadolinium that provide improvements in isotopic fractionation and ionization efficiency, respectively, opening new applications for gadolinium analysis. The schemes are demonstrated and compared in a mixed sample of gadolinium and neodymium.

and nuclear chemistry↗

Experimental Assessment of Mammalian Lipidome Complexity Using Multimodal 21 T FTICR Mass Spectrometry Imaging

Herein, we assess the complementarity and complexity of data that can be detected within mammalian lipidome mass spectrometry imaging (MSI) via matrix-assisted laser desorption ionization (MALDI) and nanospray desorption electrospray ionization (nano-DESI). We do so by employing 21 T Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) with absorption mode FT processing in both cases, allowing unmatched mass resolving power per unit time (≥613k at m/z 760, 1.536 s transients). While our results demonstrated that molecular coverage and dynamic range capabilities were greater in MALDI analysis, nano-DESI provided superior mass error, and all annotations for both modes had sub-ppm error. Taken together, these experiments highlight the coverage of 1676 lipids and serve as a functional guide for expected lipidome complexity within nano-DESI-MSI and MALDI-MSI. To further assess the lipidome complexity, mass splits (i.e., the difference in mass between neighboring peaks) within single pixels were collated across all pixels from each respective MSI experiment. The spatial localization of these mass splits was powerful in informing whether the observed mass splits were biological or artificial (e.g., matrix related). Mass splits down to 2.4 mDa were observed (i.e., sodium adduct ambiguity) in each experiment, and both modalities highlighted comparable degrees of lipidome complexity. Further, we highlight the persistence of certain mass splits (e.g., 8.9 mDa; double bond ambiguity) independent of ionization biases. Here, we also evaluate the need for ultrahigh mass resolving power for mass splits ≤4.6 mDa (potassium adduct ambiguity) at m/z > 1000, which may only be resolved by advanced FTICR-MS instrumentation.

21T-FTICR-MS↗

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Machine Learning-Based Classification of Lignocellulosic Biomass from Pyrolysis-Molecular Beam Mass Spectrometry Data

High-throughput analysis of biomass is necessary to ensure consistent and uniform feedstocks for agricultural and bioenergy applications and is needed to inform genomics and systems biology models. Pyrolysis followed by mass spectrometry such as molecular beam mass spectrometry (py-MBMS) analyses are becoming increasingly popular for the rapid analysis of biomass cell wall composition and typically require the use of different data analysis tools depending on the need and application. Here, the authors report the py-MBMS analysis of several types of lignocellulosic biomass to gain an understanding of spectral patterns and variation with associated biomass composition and use machine learning approaches to classify, differentiate, and predict biomass types on the basis of py-MBMS spectra. Py-MBMS spectra were also corrected for instrumental variance using generalized linear modeling (GLM) based on the use of select ions relative abundances as spike-in controls. Machine learning classification algorithms e.g., random forest, k-nearest neighbor, decision tree, Gaussian Naïve Bayes, gradient boosting, and multilayer perceptron classifiers were used. The k-nearest neighbors (k-NN) classifier generally performed the best for classifications using raw spectral data, and the decision tree classifier performed the worst. After normalization of spectra to account for instrumental variance, all the classifiers had comparable and generally acceptable performance for predicting the biomass types, although the k-NN and decision tree classifiers were not as accurate for prediction of specific sample types. Gaussian Naïve Bayes (GNB) and extreme gradient boosting (XGB) classifiers performed better than the k-NN and the decision tree classifiers for the prediction of biomass mixtures. The data analysis workflow reported here could be applied and extended for comparison of biomass samples of varying types, species, phenotypes, and/or genotypes or subjected to different treatments, environments, etc. to further elucidate the sources of spectral variance, patterns, and to infer compositional information based on spectral analysis, particularly for analysis of data without a priori knowledge of the feedstock composition or identity.

59 BASIC BIOLOGICAL SCIENCES↗

Algorithms and file structures to enhance software workflows for ion mobility mass spectrometry (IM-MS)

Support customizations of algorithms and raw data file structures to enhance software workflows for liquid chromatography (LC), mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS)-based metabolite characterization. Evaluate and improve the integration of ion mobility to existing MS analysis methods of the Mass Profiler Professional workflow (Mass Profiler, ID Browser and Mass Profiler Professional).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An approach to nearest neighbor analysis of pigment-protein complexes using chemical cross-linking in combination with mass spectrometry

Herein, protein cross-linking is the process of chemically joining two amino acids in a protein or protein complex by a covalent bond. When combined with mass spectrometry, it becomes one of the structural mass spectrometry techniques gaining in importance for deriving valuable three-dimensional structural information on proteins and protein complexes. This platform complements existing structural methods, such as NMR spectroscopy, X-ray crystallography, and cryo-EM. Photosynthetic pigment protein complexes serve as light-energy harvesting systems and perform photochemical conversion as part of the “early events” of photosynthesis. This chapter outlines how to prepare cross-linking pigment protein complex samples for LC-MS/MS analysis, including identification of the cross-linked species, network analysis in a protein complex, and structural modeling and justification.

59 BASIC BIOLOGICAL SCIENCES↗

Role of Transition Metals in Metal–Organic Frameworks as Nanoporous Ion Emitters for Thermal Ionization Mass Spectrometry

Thermal ionization mass spectroscopy (TIMS) is a powerful analytical technique that allows for precise determination of isotopic ratios. Analysis on low abundance samples, however, can be limited by the ionization efficiency. Following an investigation into a new type of metal-organic hybrid material devised to promote the emission of analyte ions (nano-PIES) and reduce traditional sample loading problems, this work probes the impact that changing the metal in the material has on the ionization of Uranium-238. Being derived from metal-organic frameworks (MOFs), nano-PIEs inherit the tunability of the parent MOFs; the MOF-74 series has been well studied for probing the impact various framework metals (i.e., Mg, Mn, Co, Ni, Cu, Zn, and Cd) have on material properties, and thus, a series of nano-PIEs with different metals were derived from an isoreticular MOF-74 series. In conclusion, trends in ionization efficiency were studied as a function of ionization potential, volatility, and work function of the framework metals as well as the mechanism of ionization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward nanoscale molecular mass spectrometry imaging via physically constrained machine learning on co-registered multimodal data

Mass spectrometry imaging (MSI) plays a pivotal role in investigating the chemical nature of complex systems that underly our understanding in biology and medicine. Multiple fields of life science such as proteomics, lipidomics and metabolomics benefit from the ability to simultaneously identify molecules and pinpoint their distribution across a sample. However, achieving the necessary submicron spatial resolution to distinguish chemical differences between individual cells and generating intact molecular spectra is still a challenge with any single imaging approach. Here, we developed an approach that combines two MSI techniques, matrix-assisted laser desorption/ionization (MALDI) and time-of-flight secondary ion mass spectrometry (ToF-SIMS), one with low spatial resolution but intact molecular spectra and the other with nanometer spatial resolution but fragmented molecular signatures, to predict molecular MSI spectra with submicron spatial resolution. The known relationships between the two MSI channels of information are enforced via a physically constrained machine-learning approach and directly incorporated in the data processing. We demonstrate the robustness of this method by generating intact molecular MALDI-type spectra and chemical maps at ToF-SIMS resolution when imaging mouse brain thin tissue sections. This approach can be readily adopted for other types of bioimaging where physical relationships between methods have to be considered to boost the confidence in the reconstruction product.

97 MATHEMATICS AND COMPUTING↗