Search NASA⌕ Search

SEARCH · Search NASA

Results for “MATERIALS TESTING REACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Development, calibration and experimental results obtained with an innovative calorimeter (CALMOS) for nuclear heating measurements

Nuclear heating inside an MTR reactor has to be known in order to be able to control samples temperature during irradiation experiments. An R and D program has been carried out at CEA to design a new type of in-core calorimetric system. This new development, started in 2002, has for main objective to manufacture a calorimeter suitable to monitoring nuclear heating inside the 70 MWth OSIRIS material testing reactor operated by CEA's Nuclear Energy Div. at the Saclay research center. An innovative calorimetric probe, associated to a specific handling system, has been designed to provide access to measurements both along the fissile height and on the upper part of the core, where nuclear heating still remains high. Two mock-ups of the probe were manufactured and tested in 2005 and 2009 in ex-core area of OSIRIS reactor for process validation, while a displacement system has been especially studied to move the probe along a given axial measurement range. This paper deals with the development, tests on preliminary mock-ups and the finalization of the probe. Main modeling and experimental results are presented. Moreover, alternative methods to calibration for nuclear heating rate measurements which are now possible with this new calorimeter are presented and discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development, calibration, and experimental results obtained with an innovative calorimeter (CALMOS) for nuclear heating measurements

Nuclear heating inside an MTR reactor has to be known in order to be able to control samples temperature during irradiation experiments. An R and D program has been carried out at CEA to design a new type of in-core calorimetric system. This new development, started in 2002, has for main objective to manufacture a calorimeter suitable to monitoring nuclear heating inside the 70 MWth OSIRIS material testing reactor operated by CEA's Nuclear Energy Division at the Saclay research center. An innovative calorimetric probe, associated to a specific handling system, has been designed to provide access to measurements both along the fissile height and on the upper part of the core, where nuclear heating still remains high. Two mock-ups of the probe were manufactured and tested in 2005 and 2009 in ex-core area of OSIRIS reactor for process validation, while a displacement system has been especially studied to move the probe along a given axial measurement range. This paper deals with the development, tests on preliminary mock-ups and the finalization of the probe. Main modeling and experimental results are presented. Moreover, alternative methods to calibration for nuclear heating rate measurements which are now possible with this new calorimeter are presented and discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Summary of the Department of Energy’s Advanced Demonstration and Test Reactor Options Study

An assessment of advanced reactor technology options was conducted to provide a sound comparative technical context for future decisions by the U.S. Department of Energy (DOE) concerning these technologies. Strategic objectives were established that span a wide variety of important missions, and advanced reactor technology needs were identified based on recent DOE and international studies. A broad team of stakeholders from industry, academia, and government was assembled to develop a comprehensive set of goals, criteria, and metrics to evaluate advanced irradiation test and demonstration reactor concepts. Point designs of a select number of concepts were commissioned to provide a deeper technical basis for evaluation. The technology options were compared on the bases of technical readiness and the ability to meet the different strategic objectives. Using the study's evaluation criteria and metrics, an independent group of experts from industry, universities, and national laboratories scored each of the point designs. Pathways to deployment for concepts of varying technical maturities were estimated for the different demonstration systems with regard to cost, schedule, and possible licensing approaches. This study also presents the trade-offs that exist among the different irradiation test reactor options in terms of the ability to conduct irradiations in support of advanced reactor research and development and to serve potential secondary missions. The main findings of the study indicate the following: (1) for industrial process heat supply, a high-temperature gas-cooled reactor is the best choice because of the high outlet temperature of the reactor and its strong passive and inherent safety characteristics; (2) for resource utilization and waste management, a sodium-cooled fast reactor (SFR) is best because of the use of a fast flux to destroy actinides; (3) to realize the advantages of a promising but less-mature technology, a fluoride salt-cooled high-temperature reactor and a lead-cooled fast reactor fare about the same; (4) for fulfilling the needs of a materials test reactor, a SFR is considered best because of its ability to produce high fast flux, incorporate test loops, and provide additional large volumes for testing.

Advanced reactors↗

The Fast-spectrum Transmutation Experimental Facility FASTEF: Main design achievements (part 2: Reactor building design and plant layout) within the FP7-CDT collaborative project of the European Commission

MYRRHA (Multi-purpose hybrid Research Reactor for High-tech Applications) is the flexible experimental accelerator-driven system (ADS) in development at SCK-CEN in replacement of its material testing reactor BR2. SCK-CEN in association with 17 European partners from industry, research centres and academia, responded to the FP7 (Seventh Framework Programme) call from the European Commission to establish a Central Design Team (CDT) for the design of a Fast Spectrum Transmutation Experimental Facility (FASTEF) able to demonstrate efficient transmutation and associated technology through a system working in subcritical and/or critical mode. The project has started on April 01, 2009 for a period of three years. In this paper, we present the latest concept of the reactor building and the plant layout. The FASTEF facility has evolved quite a lot since the intermediate reporting done at the ICAPP'10 and ICAPP'11 conferences 1,2. Many iterations have been performed to take into account the safety requirements. The present configuration enables an easy operation and maintenance of the facility, including the possibility to change large components of the reactor. In a companion paper 3, we present the latest configuration of the reactor core and primary system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhancing TREAT’s Pulsing Capabilities Using TREAT Upgrade Fuel

The Transient Reactor Test Facility (TREAT) at Idaho National Laboratory is an air-cooled, thermal, heterogeneous facility used to test reactor materials in simulated accident conditions by inducing fission heating with intense neutron pulses. TREAT operated from 1959 until 1994 with the primary goal of testing fast reactor fuels and was brought back online in 2017 to re-establish DOE's nuclear fuels transient testing capabilities. Beginning in the late 1970s, Idaho National Laboratory worked in conjunction with other organizations to increase TREAT's capability for in-pile testing. While these upgrades had not been implemented by the time the reactor was put into standby mode, new assemblies and graphite-urania fuel blocks with increased uranium concentrations had already been designed and fabricated. This project, as part of Idaho National Laboratory's Department of Reactor Physics, modeled the TREAT Upgrade (TU) fuel assemblies in MCNP and implemented them in an existing TREAT model. Calculations were performed using INL's high performance computer to find a critical combination of TU and standard fuel and this geometry's excess reactivity. Future work will include calculating a power coupling factor in the experiment, determining power peaking factors throughout the core, and assessing how much reactivity would be added by replacing the Inconel-625 cladding with silicon carbide.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhancing TREAT's pulsing abilities using TREAT upgrade fuel. SULI Intern Report

The Transient Reactor Test Facility (TREAT) at Idaho National Laboratory is an air-cooled, thermal, heterogeneous facility used to test reactor materials in simulated accident conditions by inducing fission heating with intense neutron pulses. TREAT operated from 1959 until 1994 with the primary goal of testing fast reactor fuels and was brought back online in 2017 to re-establish DOE’s nuclear fuels transient testing capabilities. Beginning in the late 1970s, Idaho National Laboratory worked in conjunction with other organizations to increase TREAT’s capability for in-pile testing. While these upgrades had not been implemented by the time the reactor was put into standby mode, new assemblies and graphite-urania fuel blocks with increased uranium concentrations had already been designed and fabricated. This project, as part of Idaho National Laboratory’s Department of Reactor Physics, modeled the TREAT Upgrade (TU) fuel assemblies in MCNP and implemented them in an existing TREAT model. Calculations were performed using INL’s high performance computer to find a critical combination of TU and standard fuel and this geometry’s excess reactivity. Future work will include calculating a power coupling factor in the experiment, determining power peaking factors throughout the core, and assessing how much reactivity would be added by replacing the Inconel-625 cladding with silicon carbide.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Advanced Test Reactor Long-Term (20-Year) Operational Strategy

The Department of Energy Office of Nuclear Energy (DOE-NE) and the Naval Nuclear Propulsion Program (NNPP) have identified the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) as a critical need for continued thermal irradiation testing capability to support and advance U.S. commercial and naval nuclear power systems. The ATR is currently the only suitable test reactor operating in the world that can provide these capabilities at volume. ATR must, then, plan to operate for at least the next 20 years. As of the beginning of 2024, ATR has operated for 57 years, with many of the original reactor structures, systems, and components installed and operated for 60 years. Some ATR Complex and reactor support equipment that is currently in use was installed 75 years ago with the startup of the Materials Testing Reactor (MTR).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Infrastructure and Testing Needs for Molten Salt Reactor Safeguards

Molten salt reactors (MSRs) are an attractive advanced reactor technology because of their increased fuel utilization and efficiency, the ease of fueling, and the potential to use alternative fuel cycles, including thorium and breeder/burner scenarios. Since an MSR has never been domestically operated for commercial electricity production, minimal infrastructure exists to support performance and materials testing, reactor licensing (including research, test, and operating reactors), and technology development in general. These factors could present challenges for the commercialization of the proposed design technology. Several research and development efforts and investments have begun to identify and supplement the infrastructure to accommodate the molten salt concept, including the United States Department of Energy Office of Nuclear Energy Molten Salt Reactor Program. This report reviews safeguards technology and domestic infrastructure to support the evaluation of nuclear safeguards (primarily material control and accounting) measures and approaches for salt-fueled MSRs. Recommendations for potential priority infrastructure investments, including safeguards measurement test beds and future research, are presented.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fibre optic extensometer for high radiation and high temperature nuclear applications

In the framework of the Joint Instrumentation Laboratory (LCI), gathering resources from SCK-CEN (Belgium) and CEA (France), we are developing an optical sensor in order to accurately measure radiation-induced elongation of material placed in the core of a Material Testing Reactor (MTR). This extensometer displays common advantages of Fibre Optic (FO) sensors: high resolution, easy remote sensing and multiplexing, and also compact size which is of particular interest for in pile experiments with little room available. In addition, light weight reduces gamma heating hence limiting the thermal effect. In accordance with the specifications, the sensor has preferably two fixing points defining a gauge length of 10 to 15 mm (as a minimum). The diameter is less than 2 mm. Intense gamma and neutron irradiation as well as high temperatures are the most difficult environment conditions to withstand. Reactor radiation produces huge losses in common optical fibre. The losses can be limited by selecting the fibres (mainly with high purity silica core), the wavelength range (800-1200 nm), and a measurement based on interferometry (largely insensitive to losses in the fibre thanks to the wavelength encoding of the useful signal). Heavy neutron - mainly - and gamma flux such as in MTR, also produce compaction of silica, resulting in a significant drift and preventing the use of commercial FO sensors in such environment. Knowing this issue we revised the basic scheme of Extrinsic Fabry Perot Interferometer (EFPI) in order to limit the effects of compaction. A first sensor prototype fixed on a stainless steel support was tested in the Smirnof test facility in the BR2 MTR in Mol (Belgium). The support was subject to a constant mechanical and thermal stress, and his dimensions were not supposed to vary. This test showed a very low drift of the revisited EPFI design under high irradiation field in comparison with a commercial EFPI. This result has to be confirmed with second generation sensors with an increased robustness. The other difficulty to face is high temperature. Fibre optics with metal coating allows safe operation under temperatures up to 400 deg.C and even higher. But differential dilatation between silica and typical metallic material produces differential elongation in the range of 0.5 10{sup -2} i.e 5000{mu}{epsilon} for an increase in temperature of 300-400 deg. C. Such large elongation has to be considered carefully in the sensor design and its fixing on the sample. Laboratory tests with a second generation of adapted sensors demonstrated their good accuracy: less than 1% error over a displacement of 100{mu}m (< 1 {mu}m error), at room temperature. The displacement measured can reach 250{mu}m (20000{mu}{epsilon} with a gauge length of 12.5 mm) or more. We are currently implementing metal-coated fibre and we are preparing the next in pile irradiation on the BR2 reactor scheduled for mid-2011. Other applications of the sensor can be considered. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Report on the Integration of Experimental and Modeling Data for Initial Equivalence Study of Microstructural Evolution in Irradiated LPBF 316SS

Advanced materials and manufacturing technologies are poised to improve the safety and design characteristics of nuclear technologies and meet US energy, environmental, and economic needs. In particular, metal additive manufacturing (AM) provides an opportunity to produce novel materials and component geometries, but their use is not without hurdles arising from the inherent microstructure variability that can result from the layer-by-layer build approach. Given the greater possible microstructure variability in AM materials—and the dearth of materials test reactors—it is impractical to rely solely on neutron irradiation studies to produce data for materials qualification for every possibility. This work within the Advanced Materials and Manufacturing Technologies (AMMT) Environmental Effects technical area contributes to the rapid qualification framework by developing a science-driven framework for the accelerated qualification of materials for nuclear environments. A key product of the Environmental Effects technical area of the AMMT program is the Licensing Approach with Ions and Neutrons (LAIN). This approach recognizes that whether using existing materials in new environments, newly developed materials tailored for these environments, or new manufacturing methods, the traditional decades-long approach for materials qualification does not facilitate rapid deployment. In FY 2023, the AMMT program presented a conceptual framework of specific steps to fulfill several technical challenges associated with qualifying materials for performance in radiation environments on an accelerated time frame informed by the state of the art in materials science and a review of the current regulatory landscape. The objective of this section of the Environmental Effects technical area is to critically evaluate and refine the proposed qualification framework presented under AMMT by integrating the research results of the neutron irradiations, the ion irradiations, and modeling efforts. These ongoing efforts span across Argonne National Laboratory (ANL), Idaho National Laboratory (INL), and Oak Ridge National Laboratory (ORNL) and are closely coordinated.

36 MATERIALS SCIENCE↗

Calibrating and training of neutron based NSA techniques with less SNM standards

Accessing special nuclear material (SNM) standards for the calibration of and training on nondestructive assay (NDA) instruments has become increasingly difficult in light of enhanced safeguards and security regulations. Limited or nonexistent access to SNM has affected neutron based NDA techniques more than gamma ray techniques because the effects of multiplication require a range of masses to accurately measure the detector response. Neutron based NDA techniques can also be greatly affected by the matrix and impurity characteristics of the item. The safeguards community has been developing techniques for calibrating instrumentation and training personnel with dwindling numbers of SNM standards. Monte Carlo methods have become increasingly important for design and calibration of instrumentation. Monte Carlo techniques have the ability to accurately predict the detector response for passive techniques. The Monte Carlo results are usually benchmarked to neutron source measurements such as californium. For active techniques, the modeling becomes more difficult because of the interaction of the interrogation source with the detector and nuclear material; and the results cannot be simply benchmarked with neutron sources. A Monte Carlo calculated calibration curve for a training course in Indonesia of material test reactor (MTR) fuel elements assayed with an active well coincidence counter (AWCC) will be presented as an example. Performing training activities with reduced amounts of nuclear material makes it difficult to demonstrate how the multiplication and matrix properties of the item affects the detector response and limits the knowledge that can be obtained with hands-on training. A neutron pulse simulator (NPS) has been developed that can produce a pulse stream representative of a real pulse stream output from a detector measuring SNM. The NPS has been used by the International Atomic Energy Agency (IAEA) for detector testing and training applications at the Agency due to the lack of appropriate SNM standards. This paper will address the effect of reduced access to SNM for calibration and training of neutron NDA applications along with the advantages and disadvantages of some solutions that do not use standards, such as the Monte Carlo techniques and the NPS.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NEET Enhanced Micro-Pocket Fission Detector for High Temperature Reactors - FY16 Status Report

A collaboration between the Idaho National Laboratory (INL), the Kansas State University (KSU), and the French Atomic Energy Agency, Commissariat à l'Énergie Atomique et aux Energies Alternatives, (CEA), has been initiated by the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) program for developing and testing High Temperature Micro-Pocket Fission Detectors (HT MPFD), which are compact fission chambers capable of simultaneously measuring thermal neutron flux, fast neutron flux and temperature within a single package for temperatures up to 800 °C. The MPFD technology utilizes a small, multi-purpose, robust, in-core fission chambers and thermocouple. As discussed within this report, the small size, variable sensitivity, and increased accuracy of the MPFD technology represent a revolutionary improvement over current methods used to support irradiations in US Material Test Reactors (MTRs). Previous research conducted through NEET ASI1-3 has shown that the MPFD technology could be made robust and was successfully tested in a reactor core. This new project will further the MPFD technology for higher temperature regimes and other reactor applications by developing a HT MPFD suitable for temperatures up to 800 °C. This report summarizes the research progress for year two of this three year project. Highlights from research accomplishments include: • Continuation of a joint collaboration between INL, KSU, and CEA. Note that CEA is participating at their own expense because of interest in this unique new sensor. • An updated parallel wire HT MPFD design was developed. • Program support for HT MPFD deployments was given to Accident Tolerant Fuels (ATF) and Advanced Gas-cooled Reactor (AGR) irradiation test programs. • Quality approved materials for HT MPFD construction were procured by irradiation test programs for upcoming deployments. • KSU improved and performed electrical contact and fissile material plating. • KSU delivered fissile HT MPFD parts to INL for final construction of HT MPFD prototype. • A prototype HT MPFD was constructed and analyzed at INL. • The HT MPFD has been modeled in MCNP to optimize the amount of fissile material deposition. • The HT MPFD has been modeled in MCNP to optimize the sensor location in the irradiation test. • The fissile material deposition is undergoing independent verifications. • Detector amplifier electronics have been revised and tested by KSU. • Several project meetings were held at INL and KSU to discuss the roles and responsibilities between INL, KSU, and CEA for development and deployment of the HT MPFDs. As documented in this report, FY16 funding has allowed the project to meet year two planned accomplishments to develop a HT MPFD. In addition, the accomplishments of this project have attracted independent funding from other Department of Energy Office of Nuclear Energy (DOE-NE) programs for MTR irradiations of the MPFD technology. These are significant opportunities for this NEET Enhanced Micro-Pocket Fission Detector for High Temperature Reactors project because the irradiation expense of these experiments could not be included in the original project scope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of fission gas release kinetics by on-line mass spectrometry

The release of fission gas (Xe and Kr) and helium out of nuclear fuel materials in normal operation of a nuclear power reactor can constitute a strong limitation of the fuel lifetime. Moreover, radioactive isotopes of Xe and Kr contribute significantly to the global radiological source term released in the primary coolant circuit in case of accidental situations accompanied by fuel rod loss of integrity. As a consequence, fission gas release investigation is of prime importance for the nuclear fuel cycle economy, and is the driven force of numerous R and D programs. In this domain, for solving current fuel behavior understanding issues, preparing the development of new fuels (e.g. for Gen IV power systems) and for improving the modeling prediction capability, there is a marked need for innovations in the instrumentation field, mainly for: . Quantification of very low fission gas concentrations, released from fuel sample and routed in sweeping lines. Monitoring of quick gas release variations by quantification of elementary release during a short period of time. Detection of a large range of atomic masses (e.g. H{sub 2}, HT, He, CO, CO{sub 2}, Ne, Ar, Kr, Xe), together with a performing separation of isotopes for Xe and Kr elements. Coupling measurement of stable and radioactive gas isotopes, by using in parallel mass spectrometry and gamma spectrometry techniques. To fulfill these challenging needs, a common strategy for analysis equipment implementation has been set up thanks to a recently launched collaboration between the CEA and the Univ. of Provence, with the technological support of the Liverpool Univ.. It aims at developing a chronological series of mass spectrometer devices based upon mass filter and 2D/3D ion traps with Fourier transform operating mode and having increasing levels of performances to match the previous challenges for out-of pile and in-pile experiments. The final objective is to install a high performance online mass spectrometer coupled to a gamma spectrometer in the fission product laboratory of the future Jules Horowitz Material Test Reactor. An intermediate step will consist of testing first equipment on an existing experimental facility in the LECA-STAR Hot Cell Laboratory of the CEA Cadarache. This paper presents the scientific and operational stakes linked to fission gas issues, resumes the current state of art for analyzing them in nuclear facilities, then presents the skills gathered through this collaboration to overcome technological bottlenecks. Finally it describes the implementation strategy in nuclear research facilities of the CEA Cadarache. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of Proliferation Resistance Optimization (PRO-X) Methodology to a Generic Research Reactor

The Proliferation Resistance Optimization Program (PRO-X) has been established by the NNSA to provide a framework for evaluating and integrating proliferation resistance into nuclear reactor system (core, fuel, and auxiliary facilities) designs that also maintain the safety and peaceful use missions of those systems. The research reactor (PRO-RR) area is the component of PRO-X that supports the program objectives by applying state-of-the-art analysis methods to research reactor systems. This report details the results of using a defined set of analytical tools to evaluate the neutronics, thermal hydraulics and proliferation risk characteristics of a set of parametric cores based on a generic 10 MW materials test reactor that uses a plate-type low enriched uranium (LEU) fuel. The analysis shows that by suitable adjustment of the core size, reflector configuration and power level, mission performance and safety margins can be maintained or improved while reducing the potential for production of special nuclear material.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NEET Micro-Pocket Fission Detector. Final Project report

A collaboration between the Idaho National Laboratory (INL), the Kansas State University (KSU), and the French Alternative Energies and Atomic Energy Commission, Commissariat à l'Énergie Atomique et aux Energies Alternatives, (CEA), is funded by the Nuclear Energy Enabling Technologies (NEET) program to develop and test Micro-Pocket Fission Detectors (MPFDs), which are compact fission chambers capable of simultaneously measuring thermal neutron flux, fast neutron flux and temperature within a single package. When deployed, these sensors will significantly advance flux detection capabilities for irradiation tests in US Material Test Reactors (MTRs). Ultimately, evaluations may lead to a more compact, more accurate, and longer lifetime flux sensor for critical mock-ups, and high performance reactors, allowing several Department of Energy Office of Nuclear Energy (DOE-NE) programs to obtain higher accuracy/higher resolution data from irradiation tests of candidate new fuels and materials. Specifically, deployment of MPFDs will address several challenges faced in irradiations performed at MTRs: Current fission chamber technologies do not offer the ability to measure fast flux, thermal flux and temperature within a single compact probe; MPFDs offer this option. MPFD construction is very different than current fission chamber construction; the use of high temperature materials allow MPFDs to be specifically tailored to survive harsh conditions encountered in-core of high performance MTRs. The higher accuracy, high fidelity data available from the compact MPFD will significantly enhance efforts to validate new high-fidelity reactor physics codes and new multi-scale, multi-physics codes. MPFDs can be built with variable sensitivities to survive the lifetime of an experiment or fuel assembly in some MTRs, allowing for more efficient and cost effective power monitoring. The small size of the MPFDs allows multiple sensors to be deployed, offering the potential to accurately measure the flux and temperature profiles in the reactor. This report summarizes the status at the end of year two of this three year project. As documented in this report, all planned accomplishments for developing this unique new, compact, multipurpose sensor have been completed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imminent: Irradiation Testing of (Th,Pu)O{sub 2} Fuel - 13560

Commercial-prototype thorium-plutonium oxide (Th-MOX) fuel pellets have been loaded into the material test reactor in Halden, Norway. The fuel is being operated at full power - with instrumentation - in simulated LWR / PHWR conditions and its behaviour is measured 'on-line' as it operates to high burn-up. This is a vital test on the commercialization pathway for this robust new thoria-based fuel. The performance data that is collected will support a fuel modeling effort to support its safety qualification. Several different samples of Th-MOX fuel will be tested, thereby collecting information on ceramic behaviours and their microstructure dependency. The fuel-cycle reasoning underpinning the test campaign is that commercial Th- MOX fuels are an achievable intermediate / near-term SNF management strategy that integrates well with a fast reactor future. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of the continuous dilatometer method of silicon carbide thermometry for passive irradiation temperature determination

Silicon carbide (SiC) is a primary candidate for passive irradiation temperature monitoring, and continuous dilatometry (CD) has been proposed as the key method for extracting irradiation temperatures from SiC thermometry samples. The CD method was evaluated to determine the sensitivity of the technique to the analysis procedure, as well as its accuracy and precision. Analysis found that the CD method had a ±20 °C sensitivity to the algorithm used to determine the irradiation temperatures. Comparison of the CD method with the continuous length change method for SiC thermometry showed CD is a more viable method of extracting irradiation temperatures. In conclusion, a comparison of irradiation temperatures determined by CD with those from active thermocouple measurements further validated the CD method for accurately and precisely determining irradiation temperatures in materials test reactor irradiations.

36 MATERIALS SCIENCE↗