Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Simulation Study of High-Precision Characterization of MeV Electron Interactions for Advanced Nano-Imaging of Thick Biological Samples and Microchips

The resolution of a mega-electron-volt scanning transmission electron microscope (MeV-STEM) is primarily governed by the properties of the incident electron beam and angular broadening effects that occur within thick biological samples and microchips. A precise understanding and mitigation of these constraints require detailed knowledge of beam emittance, aberrations in the STEM column optics, and energy-dependent elastic and inelastic critical angles of the materials being examined. This simulation study proposes a standardized experimental framework for comprehensively assessing beam intensity, divergence, and size at the sample exit. This framework aims to characterize electron-sample interactions, reconcile discrepancies among analytical models, and validate Monte Carlo (MC) simulations for enhanced predictive accuracy. Our numerical findings demonstrate that precise measurements of these parameters, especially angular broadening, are not only feasible but also essential for optimizing imaging resolution in thick biological samples and microchips. By utilizing an electron source with minimal emittance and tailored beam characteristics, along with amorphous ice and silicon samples as biological proxies and microchip materials, this research seeks to optimize electron beam energy by focusing on parameters to improve the resolution in MeV-STEM/TEM. This optimization is particularly crucial for in situ imaging of thick biological samples and for examining microchip defects with nanometer resolutions. Our ultimate goal is to develop a comprehensive mapping of the minimum electron energy required to achieve a nanoscale resolution, taking into account variations in sample thickness, composition, and imaging mode.

36 MATERIALS SCIENCE↗

Probing an MeV-scale scalar boson in association with a TeV-Scale top-quark partner at the LHC

Searches for new low-mass matter and mediator particles have actively been pursued at fixed target experiments and at e + e - colliders. It is challenging at the CERN LHC, but they have been searched for in Higgs boson decays and in B meson decays by the ATLAS and CMS Collaborations, as well as in a low transverse momentum phenomena from forward scattering processes (e.g., FASER). We propose a search for a new scalar particle in association with a heavy vector-like quark. We consider the scenario in which the top quark (t) couples to a light scalar φ' and a heavy vector-like top quark T. We examine single and pair production of T in pp collisions, resulting in a final state with a top quark that decays purely hadronically, a T which decays semileptonically (T → W + b → ℓ ν b), and a φ' that is very boosted and decays to a pair of collimated photons which can be identified as a merged photon system. The proposed search is expected to achieve a discovery reach with signal significance greater than 5σ (3σ) for m(T) as large as 1.8 (2) TeV and m(φ') as small as 1 MeV, assuming an integrated luminosity of 3000 fb -1 . This search can expand the reach of T, and demonstrates that the LHC can probe low-mass, MeV-scale particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Self-interacting sub-GeV dark matter with strong MeV gamma-ray

Sub-GeV dark matter (DM) with s-channel resonant self-scattering provides a promising framework for addressing small-scale structure problems. However, models that also account for the observed relic abundance through the same resonance are strongly constrained by current γ-ray observations, since the associated signals are significantly enhanced. To overcome this limitation, we propose a framework in which the relic abundance and self-scattering are governed independently by two distinct mediators. As a concrete realization, we present a singlet scalar DM model in which self-scattering is mediated by a vector boson associated with a gauged baryon number, while the relic density is determined by forbidden annihilation into dark Higgs bosons that generate the gauge boson mass. By imposing cosmological, experimental, and theoretical constraints, We identify viable parameter regions that reproduce the observed relic density, alleviate small-scale problems, and remain consistent with current bounds. Notably, the model predicts multiple distinctive MeV γ-ray signals, a significant fraction of which will be testable with next-generation MeV γ-ray telescopes, including the Compton Spectrometer and Imager (COSI).

Models for Dark Matter↗

Effect of Confinement of SIA Cluster Diffusion by Impurities on Radiation Defect Accumulation due to 14MeV neutrons in Tungsten

Impurities acting as traps, reduce the self-interstitial atom (SIA) cluster mobility, thereby increasing recombination and in turn enhancing radiation-resistance of polycrystalline materials. However, at elevated temperatures, depending on SIA-trap (impurity) binding energy, SIA clusters may trap and detrap (detach) numerous times. In tungsten, SIA clusters of all sizes glide one-dimensionally (1D) along their Burgers vector direction. Hence, detrapped SIAs would retrace their path, confining their 1D-glide between traps. However, small SIA clusters can change the direction of their 1D-glide by overcoming a rotation barrier. In addition, impurities or solutes are known to reduce this barrier. A lower rotation barrier can result in detrapped SIA clusters that diffuse in a random 1D direction, effectively leading to 3D (net-3D) diffusion. Here we investigate the effect of two cases of SIA diffusion, namely confined-1D diffusion and net-3D diffusion, on the damage accumulation in polycrystalline tungsten under 14 MeV neutron irradiation using the object kinetic Monte Carlo method. Simulations were performed using cascade debris obtained from molecular dynamics simulations with primary knock-on atom (PKA) energies corresponding to 14 MeV neutrons. In the simulations with net-3D diffusion, SIA clusters of all sizes diffuse in a random 1D direction after the clusters detrap. While for the confined 1D diffusion case, SIA clusters larger than size 5 retain their original direction of 1D-glide. In both types of simulations, trapped vacancies are assumed to be permanently immobilized. Unexpectedly, the damage accumulation was lower with confined 1D diffusion than that with net-3D. We present a systematic comparison of the influence of the two cases of SIA diffusion on the radiation damage accumulation as a function of dose rate, detrapping barrier, and impurity concentration at 1025 K.

Accumulation and recovery of lattice damage, tungs↗

Stopping Force Analysis of 235 U Elemental Fission Product Yields for $E_n$ = 0.11–92.4 MeV

We report most evaluated elemental fission product yield distributions are not experimentally measured. Instead, the majority of evaluated distributions are based on analytic expressions of the Zp-model for relevant cumulative yields. Here we report independent elemental fission product yield distributions of a 235 U target for incident neutron energies ranging from 0.11 MeV through 92.4 MeV. Atomic numbers are calculated by an approach that combines a 2E analysis with a stopping force analysis method, developed within this paper. These analyses are applied to more than 6.1 × 10 6 fission fragment ionization tracks captured within the NIFFTE (Neutron Induced Fission Fragment Tracking Experiment) collaboration fission time projection chamber (fissionTPC). A 3-Z resolution was obtained with the fissionTPC spatial and energy resolutions. Tabulated results are presented for the atomic yield and experimentally derived Zp values as a function of pre-neutron-emission fragment masses for the complete range of incident neutron energies. The stopping-force-derived Zp values tend to support the unchanged charge distribution theory within uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Response of a high-pressure 4 He scintillation detector to nuclear recoils up to 9 MeV

Helium-4-based scintillation detector technology is emerging as a strong alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, particularly in extreme gamma-ray environments. The 4 He detector is intrinsically insensitive to gamma radiation, as it has a relatively low cross-section for gamma-ray interactions, and the stopping power of electrons in the 4 He medium is low compared to that of 4 He recoil nuclei. Consequently, gamma rays can be discriminated by simple energy deposition thresholding instead of the more complex pulse shape analysis. The energy resolution of 4 He scintillation detectors has not yet been well-characterized over a broad range of energy depositions, which limits the ability to deconvolve the source spectra. In this work, an experiment was performed to characterize the response of an Arktis S670 4 He detector to nuclear recoils up to 9 MeV. The 4 He detector was positioned in the center of a semicircular array of organic scintillation detectors operated in coincidence. Deuterium–deuterium and deuterium–tritium neutron generators provided monoenergetic neutrons, yielding geometrically constrained nuclear recoils ranging from 0.0925 to 8.87 MeV. The detector response provides evidence for scintillation linearity beyond the previously reported energy range. Finally, the measured response was used to develop an energy resolution function applicable to this energy range for use in high-fidelity detector simulations needed by future applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

59 Co(p,X) spallation reaction cross sections for 250 MeV to 2 GeV protons

Cobalt is an advantageous target for probing the physics of nuclear spallation, because it is a naturally mono-isotopic element ( 59 Co), and its per-nucleon binding energy (BE/A = 8.768 MeV) is near the maximum value for all nuclei. We measured nuclear spallation cross sections for the 59 Co(p,X) reaction at five kinetic energies ranging from 250 MeV to 2 GeV. Cross sections for the production of 58 Co, 57 Co, 57 Mn, 56 Co, 56 Mn, 56 Cr, 55 Fe, 53 Fe, 54 Mn, 52 Mn, 51 Cr, 49 Cr, 48 V, 47 Sc, 46 Sc, 44 Sc, and 44 Scm are reported. Where comparable data exist in the EXFOR reaction database, we find that our measured cross sections generally agree. In many cases, we provide data for reactions or energies not currently reported in EXFOR. Our cross sections also provide evidence for the presence of α-clusters within the 59 Co nucleus, a surprising result given the asymmetry in Z (27) and N (32) for this nucleus. Finally, we use our measurements to evaluate the accuracy of spallation cross section simulations from GEANT4-based radiation transport toolkit, performed with the INCLXX-, Bertini-, and Binary-ion-cascade (BIC) based physics lists. This benchmarking activity revealed that the simulations overestimated the cross sections by a factor of ∼2–4 on average, and that the INCL-XX physics list provides the most reliable results. This evaluation informs the selection of the GEANT4 physics lists used for the analysis of data from NASA’s Psyche mission, which will measure γ rays and neutrons resulting from spallation reactions occurring on the surface of an asteroid whose surface is thought to be rich in iron-nickel metal.

43 PARTICLE ACCELERATORS↗

Ku-band electron linac for battery-powered hand-portable 2-MeV X-ray generator

X-ray generators, producing radiation in MeV range, are a critical tool for radiography, non-destructive testing and security applications. Field operation of such source requires them to be hand-portable, autonomous and allow parameter adjustability. RF linear accelerators can serve as a flexible, reliable, and robust radiation generator alternative to dangerous radioisotopes and bulky betatrons that are currently used for field radiography if their size, weight, cost, and imaging performance are matched to these sources. Here, in this paper, we present the design and test results of a 2 MeV Ku-band electron linac for a hand-portable X-ray generator system for field radiography being developed by RadiaBeam. The dramatic scale of miniaturization and cost-reduction is achieved thanks to the implementation of innovative technologies such as air-cooled Ku-band air-traffic control magnetrons, a split accelerating structure fabrication technique, and solid-state Marx modulators. This paper presents the design of the first prototype of the accelerator, its operation from Li-Ion batteries, as well as high-power and beam measurements.

43 PARTICLE ACCELERATORS↗

A Short-lived Three-Belt Structure for sub-MeV Electrons in the Van Allen Belts: Time Scale and Energy Dependence

In this study we focus on the radiation belt dynamics driven by the geomagnetic storms during September 2017. Besides the long-lasting three-belt structures of ultrarelativistic electrons (>2 MeV, existing for tens of days), which has been studied intensively during the Van Allen Probe era, it is found that magnetospheric electrons of hundreds of keVs can also have three-belt structures at similar L extent during storm time. Measurements of 500–800 keV electrons from MagEIS instrument onboard Van Allen Probes show double-peaked (L = 3.5 and 4.5, respectively) flux-versus-L-shell profile in the outer belt, which lasted for 2–3 days. During the time interval of such transient three-belt structure, the energy-versus-L spectrogram shows novel distributions differing from both “S-shaped” and “V-shaped” spectrograms reported previously. Such peculiar distribution also illustrates the energy-dependent occurrence of the three-belt profile. Furthermore, the gradual formation of “reversed energy spectrum” at L ~ 3.5 also indicates that hiss scattering inside the plasmapause contributed to the fast decay of sub-MeV remnant belt.

79 ASTRONOMY AND ASTROPHYSICS↗

Differentiating multi-MeV, multi-ion spectra with CR-39 solid-state nuclear track detectors

The development of high intensity petawatt lasers has created new possibilities for ion acceleration and nuclear fusion using solid targets. In such laser-matter interaction, multiple ion species are accelerated with broad spectra up to hundreds of MeV. To measure ion yields and for species identification, CR-39 solid-state nuclear track detectors are frequently used. However, these detectors are limited in their applicability for multi-ion spectra differentiation as standard image recognition algorithms can lead to a misinterpretation of data, there is no unique relation between track diameter and particle energy, and there are overlapping pit diameter relationships for multiple particle species. In this report, we address these issues by first developing an algorithm to overcome user bias during image processing. Second, we use calibration of the detector response for protons, carbon and helium ions (alpha particles) from 0.1 to above 10 MeV and measurements of statistical energy loss fluctuations in a forward-fitting procedure utilizing multiple, differently filtered CR-39, altogether enabling high-sensitivity, multi-species particle spectroscopy. To validate this capability, we show that inferred CR-39 spectra match Thomson parabola ion spectrometer data from the same experiment. Filtered CR-39 spectrometers were used to detect, within a background of ~ 2 × 10 11 sr -1 J -1 protons and carbons, (1.3 ± 0.7) × 10 8 sr -1 J -1 alpha particles from laser-driven proton-boron fusion reactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a mock up nuclear waste package using energy resolved MeV neutron analysis

Reliable radiographic methods for characterizing nuclear waste packages non-destructively (without the need to open containers) have the potential to significantly contribute to safe handling and future disposal options, particularly for legacy waste of unknown content. Due to required shielding of waste containers and the need to characterize materials consisting of light elements, X-ray methods are not suitable. Here, energy-resolved MeV neutron radiography is demonstrated as a first-of-its-kind application for non-destructive and remote examination of mock up nuclear waste packages from a safe position using time-of-flight techniques enabled by a novel event-mode imaging detector system. Energy-resolved neutron transmission spectra were measured spatially, permitting the detection of analogue materials to actual nuclear waste such as water, melamine, and ion exchange resin within a 2.54 cm wall thickness steel pipe. The results demonstrate the capability to locate the materials through this wall thickness by radiography and tomographic reconstruction, revealing detailed 3D distributions and structural anomalies. The method effectively detects residual water in ion exchange resin, highlighting its sensitivity to moisture content, a crucial parameter for nuclear waste characterization. Monte Carlo simulations are in agreement with the experimental findings, providing a pathway to simulate waste forms more difficult to tackle experimentally. This work paves the way to apply sub-nanosecond intense MeV neutron sources, such as laser-driven neutron sources under development, to nuclear waste characterization.

36 MATERIALS SCIENCE↗

A multi-MeV alpha particle source via proton-boron fusion driven by a 10-GW tabletop laser

Nuclear fusion between protons and boron-11 nuclei has undergone a revival of interest thanks to the rapid progress in pulsed laser technology. Potential applications of such reaction range from controlled nuclear fusion to radiobiology and cancer therapy. A laser-driven fusion approach consists in the interaction of high-power, high-intensity pulses with H- and B-rich targets. We report on an experiment exploiting proton-boron fusion in CN-BN targets to obtain high-energy alpha particle beams (up to 5 MeV) using a very compact approach and a tabletop laser system with a peak power of ~10 GW, which can operate at high-repetition rate (up to 1 kHz). The secondary resonance in the cross section of proton-boron fusion (~150 keV in the center-of-mass frame) is exploited using a laser-based approach. The generated alpha particles are characterized in terms of energy, flux, and angular distribution using solid-state nuclear-track detectors, demonstrating a flux of ~10 5 particles per second at 10 Hz, and ~10 6 per second at 1 kHz. Hydrodynamic and particle-in-cell numerical simulations support our experimental findings. Potential impact of our approach on future spread of ultra-compact, multi-MeV alpha particle sources driven by moderate intensity (10 16 -10 17 W/cm 2 ) laser pulses is anticipated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-repetition-rate, multi-MeV deuteron acceleration from converging heavy water microjets at laser intensities of 10 21 W/cm 2

Herein we demonstrate high repetition-rate deuteron acceleration by irradiating a continuously flowing, ambient temperature liquid heavy water jet with the high-intensity ALEPH laser. The laser delivered up to 5.5 J (120 TW, 1.2 × 10 21 W/cm 2 ) laser energy on target at 0.5 Hz. A high repetition-rate Thomson parabola spectrometer measured the deuteron beam energy spectra on each shot for 60 sequential shots (two minutes). Peak fluxes of 5 x 10 10 deuterons/sr/pulse, corresponding to an average flux of 1.5 x 10 12 deuterons/sr/min, were demonstrated with deuteron energies reaching up to 4.4 MeV. High shot-to-shot stability is observed up to 40%–50% of the maximum deuteron energy. These deuteron beams are suited for fast neutron production through deuteron breakup in a converter yielding energies similar to deuteron–deuteron (D–D, 2.45 MeV) fusion reactions of importance for material damage studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Image plate multi-scan response to fusion protons in the range of 1–14 MeV

Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.

Instruments & Instrumentation↗

Scalings of laser-driven MeV electron sources with relativistic multi-picosecond laser pulses

We investigate the generation of MeV electrons in relativistic multi-picosecond laser–solid interactions, using two-dimensional particle-in-cell simulations. Scanning a parameter space of intensities from 10 18 to 10 20 W/cm 2 and pulse durations between 100 fs and 10 ps, we discuss scalings of the effective hot electron temperature and MeV electron dose relevant to applications, as well as the direct laser acceleration mechanism that drives electrons to energies much higher than the ponderomotive potential of the laser pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and scaling of MeV x-ray radiography at NIF-ARC

We investigate the generation of MeV x-rays using the Advanced Radiography Capability laser system at the National Ignition Facility using 1, 10, and 38 ps pulse durations, with laser energies reaching up to 4 kJ and using compound parabolic concentrators. Hydrodynamic simulations using up-to-date measurements of the contrast of the ARC laser are conducted, allowing us to employ an electron scaling model that incorporates scale length and pulse duration, which aligns closely with the observed temperature distributions. Comparable x-ray sources, in terms of dose, are generated when using a 10 ps pulse duration with 2.4 kJ at ∼1.9 ± 0.4 × 10 18 W/cm 2 and when using a 38 ps pulse duration with 4 kJ at 9.9 ± 0.4 × 10 17 W/cm 2 , both achieving ∼16 rad in air at 1 m for x-ray energies > 0.5 MeV. Radiographs performed on the laser “line-of-sight” show significant improvements in image quality than radiographs performed at 65 degrees to the laser axis. We verify the radiography performance using Monte Carlo Simulations.

Physics - Plasma physics↗

Energy response characterization of current-mode MeV Cherenkov aerogel detectors

Current-mode Cherenkov aerogel detectors have been used to measure time resolved spectra of MeV radiographic x-ray sources and have been considered to replace gas Cherenkov systems. The simulations of the Cherenkov response of aerogel detectors have uncertainties in how to model the complex structure of aerogels. Data from three sites—the Idaho electron beam, the Los Alamos Site electron beam and microtron sources at Los Alamos—have been used to calibrate the relative energy response of 15 aerogels, varying in density from 10 to 430 mg/cm 3 , from incident electrons with energies from 1 to 12 MeV. Detector simulations need to introduce density variation in the aerogels to match the collected data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase-space sensitivity (weight functions) of 3 MeV proton diagnostics

Abstract The weight function W ( X ) is a diagnostic sensitivity to phase-space variables X that relates the measured signal C to the distribution function F ( X ) through the equation C = ∫ W ( X ) F ( X ) d X . In the present work, an algorithm to calculate W for a diagnostic that measures 3 MeV protons produced in d(d,p)t fusion reactions between a fast ion and a thermal deuteron is developed. The emitted protons escape the tokamak on curved orbits and are detected. These curved orbits constitute effective diagnostic ‘sightlines’. The presented algorithm accounts for the complications associated with these curved sightlines. An initial calculation of time-reversed proton orbits computes effective solid angles and sightlines for the relevant range of incident proton velocity vectors. These precomputed orbits are then used within the framework of FIDASIM (2020 Plasma Phys. Cont. Fusion 62 105008) to calculate the reactivity averaged over the thermal distribution of the ‘target’ deuterons and the probability that a fast ion of specified energy and pitch has a gyroangle that is consistent with the kinematic equations along each of the sightlines. Comparisons with analytic formulas and with independent calculations for the Mega Amp Spherical Tokamak 3 MeV proton diagnostic verify the algorithm.

Physics↗