Microchannel Voltammetry in the Presence of Large External Voltages and Electric Fields

The ability to perform electrochemistry in the presence of large voltages and electric field magnitudes without concern for the local potential has many possible applications in micro/nanofluidic assays and in capillary electrophoresis. Traditionally, electrochemistry in the presence of significant external electric fields has been dominated by end-channel detection for capillary and microchip electrophoresis detection. Here, we describe novel instrumentation for potentiostatically controlled voltammetry that can be applied in the presence of high external voltages and electric fields. Cyclic voltammetry is demonstrated without significant shifts in the half-wave potential at working electrodes at local potentials of up to ~1500 V and field strengths of up to 3000 V/cm, using a standard Ag/AgCl reference electrode.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integration of CeO 2 -Based Memristor with Vertically Aligned Nanocomposite Thin Film: Enabling Selective Conductive Filament Formation for High-Performance Electronic Synapses

The CeO 2 -based memristor has attracted significant attention due to its intrinsic resistive switching (RS) properties, large on/off ratio, and great plasticity, making it a promising candidate for artificial synapses. However, significant challenges such as high power consumption and poor device reliability hinder its broad application in neuromorphic microchips. To tackle these issues, in this work, we design a novel bilayer (BL) memristor by integrating a CeO 2 -based memristor with a Co-CeO 2 vertically aligned nanocomposite (VAN) layer and compare it with the single layer (SL) memristor. Preliminary electrical testing reveals that the BL memristor offers a reduced set/reset voltage (~67% lower), a higher on/off ratio (~5 × 10 2 ), enhanced device reliability, and improved device-to-device variation compared to the SL memristor. Insight from COMSOL simulation, coupled with microstructural analysis, provides a comprehensive elucidation on how the VAN layer facilitates the selective conductive filament (CF) formation. Subsequently, the plasticity of the BL memristor is evaluated through long-term potentiation/depression (LTP/LTD), paired-pulse facilitation (PPF), and spike-time-dependent plasticity (STDP). The spiking neural network (SNN) built upon the BL memristor achieves remarkable accuracy (~94%) after only 12 iterations, underscoring its potential for high-performance neural networks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Online monitoring of solutions within microfluidic chips: simultaneous Raman and UV-Vis absorption spectroscopies

Microfluidics is an appealing analytical tool in the global effort to close the nuclear fuel cycle. Using a microfluidic chip permits analysis of greatly reduced sample volumes compared to what is necessary for traditional analytical methods. There is a commensurate reduction in disposal volume and cost. Development of spectroscopic methods practicable on the microscale are necessary to take advantage of the microchip configuration. This study uses simultaneously applied UV-vis and micro-Raman spectroscopies adapted to function on the microscale to analyze in situ both the Nd3+ (UV-vis active) and HNO3 (Raman active) concentrations in the same sample. An adjustable translation platform was designed to hold the micro-Raman probe above and perpendicular to the chip face, and the UV-vis probe in the plane of the chip. These complimentary spectral techniques when processed through multivariate PLS (Partial Least Squares) models gave an accurate picture of the widely varying solution concentrations as a function of time for each solution component. Solution matrix effects can drastically alter analyte signatures as measured by both UV-vis absorbance and Raman spectroscopy. PLS methods successfully modeled these spectral changes and accurately measured concentrations of components of interest within the microfluidic chip.

on-line monitoring, microfluidics, Raman, UV-vis↗

High-throughput and high-efficiency sample preparation for single-cell proteomics using a nested nanowell chip

Abstract Global quantification of protein abundances in single cells could provide direct information on cellular phenotypes and complement transcriptomics measurements. However, single-cell proteomics is still immature and confronts many technical challenges. Herein we describe a nested nanoPOTS (N2) chip to improve protein recovery, operation robustness, and processing throughput for isobaric-labeling-based scProteomics workflow. The N2 chip reduces reaction volume to <30 nL and increases capacity to >240 single cells on a single microchip. The tandem mass tag (TMT) pooling step is simplified by adding a microliter droplet on the nested nanowells to combine labeled single-cell samples. In the analysis of ~100 individual cells from three different cell lines, we demonstrate that the N2 chip-based scProteomics platform can robustly quantify ~1500 proteins and reveal membrane protein markers. Our analyses also reveal low protein abundance variations, suggesting the single-cell proteome profiles are highly stable for the cells cultured under identical conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Multi-beam X-ray ptychography using coded probes for rapid non-destructive high resolution imaging of extended samples

Imaging large areas of a sample non-destructively and with high resolution is of great interest for both science and industry. For scanning coherent X-ray diffraction microscopy, i. e., ptychography, the achievable scan area at a given spatial resolution is limited by the coherent photon flux of modern X-ray sources. Multibeam X-ray ptychography can improve the scanning speed by scanning the sample with several parallel mutually incoherent beams, e. g., generated by illuminating multiple focusing optics in parallel by a partially coherent beam. The main difficulty with this scheme is the robust separation of the superimposed signals from the different beams, especially when the beams and the illuminated sample areas are quite similar. We overcome this difficulty by encoding each of the probing beams with its own X-ray phase plate. This helps the algorithm to robustly reconstruct the multibeam data. We compare the coded multibeam scans to uncoded multibeam and single beam scans, demonstrating the enhanced performance on a microchip sample with regular and repeating structures.

47 OTHER INSTRUMENTATION↗

Correlative Electron and Fluorescence Microscopy of Magnetotactic Bacteria in Liquid: Toward In Vivo Imaging

Magnetotactic bacteria biomineralize ordered chains of uniform, membrane-bound magnetite or greigite nanocrystals that exhibit nearly perfect crystal structures and species-specific morphologies. Transmission electron microscopy (TEM) is a critical technique for providing information regarding the organization of cellular and magnetite structures in these microorganisms. However, conventional TEM can only be used to image air-dried or vitrified bacteria removed from their natural environment. Here we present a correlative scanning TEM (STEM) and fluorescence microscopy technique for imaging viable cells of Magnetospirillum magneticum strain AMB-1 in liquid using an in situ fluid cell TEM holder. Fluorescently labeled cells were immobilized on microchip window surfaces and visualized in a fluid cell with STEM, followed by correlative fluorescence imaging to verify their membrane integrity. Notably, the post-STEM fluorescence imaging indicated that the bacterial cell wall membrane did not sustain radiation damage during STEM imaging at low electron dose conditions. We investigated the effects of radiation damage and sample preparation on the bacteria viability and found that approximately 50% of the bacterial membranes remained intact after an hour in the fluid cell, decreasing to ~30% after two hours. These results represent a first step toward in vivo studies of magnetite biomineralization in magnetotactic bacteria.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass spectrometry-based proteomics: existing capabilities and future directions

Mass spectrometry-based proteomics provides a means for identification, characterization, and quantification of biomolecules that are integral components of the processes essential for life. Characterization of proteins present in a biological system at the proteome and sub-proteomes (e.g., the phosphoproteome, proteoglycome, or degradome/peptidome) levels provides a foundation for understanding fundamental aspects as well as potentially a range of translational applications. Emerging technologies such as ion mobility separations coupled with mass spectrometry and microchip-based - proteome measurements combined with continued enhancement of MS instrumentation and separation techniques, such as reversed phase liquid chromatography and potentially capillary electrophoresis, show great promise for both broad undirected as well as targeted measurements and will be critical for e.g., the proteome-wide characterization of post translational modifications and identification, or the verification, and validation of potential biomarkers of disease. MS-based proteomics is also increasingly demonstrating great potential for contributing to our understanding of the dynamics, reactions, and roles proteins and peptides play advancing our understanding of biology on a system wide level for a wide range of applications, from investigations of microbial communities, bioremediation, and human health and disease states alike.

59 BASIC BIOLOGICAL SCIENCES↗

Enhancing Biological Analyses with Three Dimensional Field Asymmetric Ion Mobility, Low Field Drift Time Ion Mobility and Mass Spectrometry (µFAIMS/IMS-MS) Separations

We report the first evaluation of a platform coupling a high speed field asymmetric ion mobility spectrometry microchip (µFAIMS) with drift tube ion mobility and mass spectrometry (IMS-MS). The µFAIMS/IMS-MS platform was used to analyze biological samples and simultaneously acquire multidimensional information of detected features from the measured FAIMS compensation fields and IMS drift times, while also obtaining accurate ion masses. These separations thereby increase the overall separation power, resulting increased information content, and provide more complete characterization of more complex samples. The separation conditions were optimized for sensitivity and resolving power by the selection of gas compositions and pressures in the FAIMS and IMS separation stages. The resulting performance provided three dimensional separations, benefitting both broad complex mixture studies and targeted analyses by e.g. improving isomeric separations and allowing detection of species obscured by “chemical noise” and other interfering peaks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neodymium zirconate (Nd{sub 2}Zr{sub 2}O{sub 7}) transparent ceramics as a solid state laser material

Transparent neodymium zirconate (Nd{sub 2}Zr{sub 2}O{sub 7}) ceramics have been fabricated from nanoparticles prepared by combustion synthesis. Emission at 1054.5 nm has been demonstrated using a laser diode pump at 800 nm. A transmittance of 60% at wavelengths longer than {approx}900 nm was achieved. A consequence of the very high concentration of Nd ions (1.32x10{sup 28} ions/m{sup 3}) is that the absorption bands are wider than those of Nd doped Y{sub 3}Al{sub 5}O{sub 12} (Nd:YAG) facilitating pumping over a broader range of wavelengths. The full width at half maximum of the emission peak is also larger than that of Nd:YAG, and the decay time is 460 {mu}s making Nd{sub 2}Zr{sub 2}O{sub 7} an excellent candidate for efficient high-power microchip lasers emitting at 1054 nm with diode pumping at {approx}800 or {approx}900 nm.

36 MATERIALS SCIENCE↗

Controllable giant dielectric constant in AlO{sub x}/TiO{sub y} nanolaminates.

Dielectric materials exhibiting high dielectric constants play critical roles in a wide range of applications from microchip energy storage embedded capacitors for implantable biomedical devices to energy storage capacitors for a new generation of renewable energy generation/storage systems. Instead of searching for new materials, we demonstrate that giant dielectric constants can be achieved by integrating two simple oxides with low dielectric constants into nanolaminate structures. In addition, the obtained dielectric constant values are highly tunable by manipulating the sub-layer thicknesses of the component oxides to control the number of interfaces and oxygen redistribution. The work reported here opens a new pathway for the design and development of high dielectric constant materials based on the nanolaminate concept.

36 MATERIALS SCIENCE↗

Open and closed loop manipulation of charged microchiplets in an electric field

We demonstrate the ability to orient, position, and transport microchips (“chiplets”) with electric fields. In an open-loop approach, modified four phase traveling wave potential patterns manipulate chiplets in a dielectric solution using dynamic template agitation techniques. Repeatable parallel assembly of chiplets is demonstrated to a positional accuracy of 6.5 μm using electrodes of 200 μm pitch. Chiplets with dipole surface charge patterns are used to show that orientation can be controlled by adding unique charge patterns on the chiplets. Chip path routing is also demonstrated. With a closed-loop control system approach using video feedback, dielectric, and electrophoretic forces are used to achieve positioning accuracy of better than 1 μm with 1 mm pitch driving electrodes. These chip assembly techniques have the potential to enable future printer systems where inputs are electronic chiplets and the output is a functional electronic system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dependence of electric strength on the ambient temperature

At present, the volume concentration of electronic components in their miniaturization to different types of microchips and increasing their performance raises the problem of cooling such elements due to the increasing density of heat flow of heat loss. Compliance with safe operating temperature of active semiconductor element is very closely related to the reliability and durability not only components, but also the entire device. Often it is also necessary to electrically isolate the unit from the side of the cooler air. Cooling demand by natural convection is typical for applications with high operating reliability. To the reliability of the system for removing heat loss increased, it is necessary to minimize need to use the mechanically or electrically powered elements, such as circulation pumps or fans. Experience to date with applications of heat pipe in specific systems appears to be the most appropriate method of cooling.

42 ENGINEERING↗

Femtosecond laser three-dimensional micro- and nanofabrication

The rapid development of the femtosecond laser has revolutionized materials processing due to its unique characteristics of ultrashort pulse width and extremely high peak intensity. The short pulse width suppresses the formation of a heat-affected zone, which is vital for ultrahigh precision fabrication, whereas the high peak intensity allows nonlinear interactions such as multiphoton absorption and tunneling ionization to be induced in transparent materials, which provides versatility in terms of the materials that can be processed. More interestingly, irradiation with tightly focused femtosecond laser pulses inside transparent materials makes three-dimensional (3D) micro- and nanofabrication available due to efficient confinement of the nonlinear interactions within the focal volume. Additive manufacturing (stereolithography) based on multiphoton absorption (two-photon polymerization) enables the fabrication of 3D polymer micro- and nanostructures for photonic devices, micro- and nanomachines, and microfluidic devices, and has applications for biomedical and tissue engineering. Subtractive manufacturing based on internal modification and fabrication can realize the direct fabrication of 3D microfluidics, micromechanics, microelectronics, and photonic microcomponents in glass. These microcomponents can be easily integrated in a single glass microchip by a simple procedure using a femtosecond laser to realize more functional microdevices, such as optofluidics and integrated photonic microdevices. The highly localized multiphoton absorption of a tightly focused femtosecond laser in glass can also induce strong absorption only at the interface of two closely stacked glass substrates. Consequently, glass bonding can be performed based on fusion welding with femtosecond laser irradiation, which provides the potential for applications in electronics, optics, microelectromechanical systems, medical devices, microfluidic devices, and small satellites. This review paper describes the concepts and principles of femtosecond laser 3D micro- and nanofabrication and presents a comprehensive review on the state-of-the-art, applications, and the future prospects of this technology.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of non-contact measurement of the thermal expansion coefficients of materials based on laser feedback interferometry

The noncooperative and ultrahigh sensitive length measurement approach is of great significance to the study of a high-precision thermal expansion coefficient (TEC) determination of materials at a wide temperature range. The novel approach is presented in this paper based on the Nd:YAG microchip laser feedback interferometry with 1064 nm wavelength, the beam frequency of which is shifted by a pair of acousto-optic modulators and then the heterodyne phase measurement technique is used. The sample is placed in a muffle furnace with two coaxial holes opened on the opposite furnace walls. The measurement beams are perpendicular and coaxial on each surface of the sample, the configuration which can not only achieve the length measurement of sample but also eliminate the influence of the distortion of the sample supporter. The reference beams inject on the reference mirrors which are put as possible as near the holes, respectively, to eliminate the air disturbances and the influence of thermal lens effect out of the furnace chamber. For validation, the thermal expansion coefficients of aluminum and steel 45 samples are measured from room temperature to 748 K, which proved measurement repeatability of TECs is better than 0.6 × 10{sup −6}(K{sup −1}) at the range of 298 K–598 K and the high-sensitive non-contact measurement of the low reflectivity surface induced by the oxidization of the samples at the range of 598 K–748 K.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing photon-pair generation electronically using a p-i-n diode incorporated in a silicon microring resonator

Silicon photonic microchips may be useful for compact, inexpensive, room-temperature optically pumped photon-pair sources, which unlike conventional photon-pair generators based on crystals or optical fibers, can be manufactured using CMOS-compatible processes on silicon wafers. It has been shown that photon pairs can be created in simple structures such as microring resonators at a rate of a few hundred kilohertz using less than a milliwatt of optical pump power, based on the process of spontaneous four-wave mixing. To create a practical photon-pair source, however, also requires some way of monitoring the device and aligning the pump wavelength when the temperature varies, since silicon resonators are highly sensitive to temperature. In fact, monitoring photodiodes are standard components in classical laser diodes, but the incorporation of germanium or InGaAs photodiodes would raise the cost and fabrication complexity. Here, we present a simple and effective all-electronic technique for finding the optimum operating point for the microring used to generate photon pairs, based on measuring the reverse-biased current in a silicon p-i-n junction diode fabricated across the waveguide that constitutes the silicon microring. We show that by monitoring the current, and using it to tune the pump laser wavelength, the photon-pair generation properties of the microring can be preserved over a temperature range of more than 30 °C.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Highly sensitive simple homodyne phase detector for ultrasonic pulse-echo measurements

Progress in microelectronic technology has allowed us to design and develop a simple but, professional quality instrument for ultrasonic pulse-echo probing of the elastic properties of materials. The heart of this interfer- ometer lies in the AD8302 microchip, a gain and phase detector from Analog Devices, Inc. The interferometer was tested by measuring the temperature dependences of the ultrasound speed and attenuation in a ferro- electric KTa 0.92 Nb 0.08 O 3 (KTN) crystal at a frequency of about 40 MHz. These tests demonstrated that our instrument is capable of detecting the relative changes in the sound speed v on the level of Δv/v ~ 10 –7 . In addition, the ultrasound attenuation revealed new features in the development of the low-temperature structure of the ferroelectric KTN crystal.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Generating photon pairs from a silicon microring resonator using an electronic step recovery diode for pump pulse generation

Generation of photon pairs from compact, manufacturable, and inexpensive silicon (Si) photonic devices at room temperature may help develop practical applications of quantum photonics. An important characteristic of photon-pair generation is the two-photon joint spectral intensity, which describes the frequency correlations of the photon pair. Recent attempts to generate a factorizable photon-pair state suitable for heralding have used short optical pump pulses from mode-locked lasers, which are much more expensive and bigger table-top or rack-sized instruments compared with the Si microchip used for generating photon pairs, and thus dominate the cost and inhibit the miniaturization of the source. Here, we generate photon pairs from an Si microring resonator by using an electronic step-recovery diode to drive an electro-optic modulator which carves the pump light from a continuous-wave laser diode into pulses of the appropriate width, thus potentially eliminating the need for optical mode-locked lasers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A micro-scale plasma spectrometer for space and plasma edge applications (invited)

A plasma spectrometer design based on advances in lithography and microchip stacking technologies is described. A series of curved plate energy analyzers, with an integrated collimator, is etched into a silicon wafer. Tests of spectrometer elements, the energy analyzer and collimator, were performed with a 5 keV electron beam. The measured collimator transmission and energy selectivity were in good agreement with design targets. A single wafer element could be used as a plasma processing or fusion first wall diagnostic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗