Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROFLUIDICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

EcAMSat and BioSentinel: Autonomous Bio Nanosatellites Addressing Strategic Knowledge Gaps for Manned Spaceflight Beyond LEO

Manned missions beyond low Earth orbit (LEO) require that several strategic knowledge gaps about the effects of space travel on the human body be addressed. NASA Ames Research Center has been the leader in developing autonomous bio nanosatellites, including past successful missions for GeneSat, PharmaSat, and O/OREOS, that tackled some of these issues. These nanosatellites provide in situ measurements, which deliver insight into the dynamic changes in cell behavior in microgravity. In this talk, two upcoming bio nanosatellites developed at Ames, the E. coli Antimicrobial Satellite (EcAMSat) and BioSentinel, will be discussed. Both satellites contain microfluidic systems that precisely deliver nutrients to the microorganisms stored within wells of fluidic cards. Each well, in turn, has its own 3-color LED and detector system which is used to monitor changes in metabolic activity with alamarBlue, a redox indicator, and the optical density of the cells. EcAMSat investigates the effects of microgravity on bacterial resistance to antimicrobial drugs, vital knowledge for understanding how to maintain the health of astronauts in long-term and beyond LEO spaceflight. The behavior of wild type and mutant uropathic E. coli will be compared in microgravity and with ground data to help understand the molecular mechanisms behind antibiotic resistance and how these phenotypes might change in space. BioSentinel seeks to directly measure the effects of space radiation on budding yeast S. cerevisiae, particularly double strand breaks (DSB). While hitching a ride on the SLS EM-1 mission (Orion's first unmanned mission to the moon) in 2018, BioSentinel will be kicked off and enter into a heliocentric orbit, becoming the first study of the effects of radiation on living organisms outside LEO since the Apollo program. The yeast are stored in eighteen independent 16-well microfluidic cards, which will be individually activated over the 12 month mission duration. In addition to the wild type and radiation-sensitive mutant strains, a BioSentinel strain of yeast has been developed, which requires a DSB to reactivate growth, thereby allowing for a direct measurement of DSBs caused by radiation. These two missions demonstrate the utility of using autonomous nanosatellites to address strategic knowledge gaps in the push to once again extend manned spaceflight beyond LEO.

Padgen, Michael R.↗

EcAMSat and BioSentinel: Autonomous Bio Nanosatellites Addressing Strategic Knowledge Gaps for Manned Spaceflight Beyond LEO

Manned missions beyond low Earth orbit (LEO) require that several strategic knowledge gaps about the effects of space travel on the human body be addressed. NASA Ames Research Center has been the leader in developing autonomous bio nanosatellites, including past successful missions for GeneSat, PharmaSat, and OOREOS, that tackled some of these issues. These nanosatellites provide in situ measurements, which deliver insight into the dynamic changes in cell behavior in microgravity. In this talk, two upcoming bio nanosatellites developed at Ames, the E. coli Antimicrobial Satellite (EcAMSat) and BioSentinel, will be discussed. Both satellites contain microfluidic systems that precisely deliver nutrients to the microorganisms stored within wells of fluidic cards. Each well, in turn, has its own 3-color LED and detector system which is used to monitor changes in metabolic activity with alamarBlue, a redox indicator, and the optical density of the cells. EcAMSat investigates the effects of microgravity on bacterial resistance to antimicrobial drugs, vital knowledge for understanding how to maintain the health of astronauts in long-term and beyond LEO spaceflight. The behavior of wild type and mutant uropathic E. coli will be compared in microgravity and with ground data to help understand the molecular mechanisms behind antibiotic resistance and how these phenotypes might change in space. BioSentinel seeks to directly measure the effects of space radiation on budding yeast S. cerevisiae, particularly double strand breaks (DSB). While hitching a ride on the SLS EM-1 mission (Orions first unmanned mission to the moon) in 2018, BioSentinel will be kicked off and enter into a heliocentric orbit, becoming the first study of the effects of radiation on living organisms outside LEO since the Apollo program. The yeast are stored in eighteen independent 16-well microfluidic cards, which will be individually activated over the 12 month mission duration. In addition to the wild type and radiation-sensitive mutant strains, a BioSentinel strain of yeast has been developed, which requires a DSB to reactivate growth, thereby allowing for a direct measurement of DSBs caused by radiation. These two missions demonstrate the utility of using autonomous nanosatellites to address strategic knowledge gaps in the push to once again extend manned spaceflight beyond LEO.

Padgen, Mike↗

Sample Processor for Life on Icy Worlds (SPLIce): Design and Test Results

We report the design, development, and testing of the Sample Processor for Life on Icy Worlds (SPLIce) system, a microfluidic sample processor to enable autonomous detection of signatures of life and measurements of habitability parameters in Ocean Worlds. This monolithic fluid processing-and-handling system (Figure 1; mass 0.5 kg) retrieves a 50-L-volume sample and prepares it to supply a suite of detection instruments, each with unique preparation needs. SPLIce has potential applications in orbiter missions that sample ocean plumes, such as found in Saturns icy moon Enceladus, or landed missions on the surface of icy satellites, such as Jupiters moon Europa. Answering the question Are we alone in the universe? is captivating and exceptionally challenging. Even general criteria that define life very broadly include a significant role for water [1,2]. Searches for extinct or extant life therefore prioritize locations of abundant water whether in ancient (Mars), or present (Europa and Enceladus) times. Only two previous planetary missions had onboard fluid processing: the Viking Biology Experiments [3] and Phoenixs Wet Chemistry Laboratory (WCL) [4]. SPLIce differs crucially from those systems, including its capability to process and distribute L-volume samples and the integration autonomous control of a wide range of fluidic functions, including: 1) retrieval of fluid samples from an evacuated sample chamber; 2) onboard multi-year storage of dehydrated reagents; 3) integrated pressure, pH, and conductivity measurement; 4) filtration and retention of insoluble particles for microscopy; 5) dilution or vacuum-driven concentration of samples to accommodate instrument working ranges; 6) removal of gas bubbles from sample aliquots; 7) unidirectional flow (check valves); 8) active flow-path selection (solenoid-actuated valves); 9) metered pumping in 100 nL volume increments. The SPLIce manifold, made of three thermally fused layers of precision-machined cyclo-olefin polymer, supports all fluidic components (Figure 1) and integrated microchannels (125 x 250 m). Fluid is pumped by a stepper-motor-driven pump (Lee Co.). The functionality of the integrated MEMS pressure sensor (Honeywell) and passive check valves (Figure 2) were tested in conjunction with our newly designed integral bubble traps (Figure 3) and hydrophobic membrane-based concentrator (Figure 4). The concentrator (initially tested as a standalone component) demonstrated 5-fold vacuum-evaporative concentration. Polyethylene fused bead beds (PEFBBs; 50 porosity) store drylyophilized buffers, calibrants, and fluorescent dyes, and also promote mixing of sample with calibrant, dye, or H2O. Software-controlled automated tests demonstrated successful 1) fluid delivery to each component 2) valve and pump synchronization 3) sample aliquot delivery to instrument interface ports, and 4) rehydration of vacuum-dried fluorescent dye. In Figure 5, fluorescein on PEFBBs was rehydrated for 15 min using a pump-delivered water aliquot; it is displaced as H2O enters the bottom of the channel and pushes the dye into a check valve. Ultimately, SPLIce will fluorescently label amino acids in the sample for microchip-based electrophoretic (MCE) chiral separation and detection to seek and quantify key organic bio-signatures [5]; it will also deliver sample to a microfluidic version of WCL (mWCL) to measure soluble ions and redox-active species.

Life detection↗

Biosentinel: Improving Desiccation Tolerance of Yeast Biosensors for Deep-Space Missions

BioSentinel is one of 13 secondary payloads to be deployed on Exploration Mission 1 (EM-1) in 2019. We will use the budding yeast Saccharomyces cerevisiae as a biosensor to determine how deep-space radiation affects living organisms and to potentially quantify radiation levels through radiation damage analysis. Radiation can damage DNA through double strand breaks (DSBs), which can normally be repaired by homologous recombination. Two yeast strains will be air-dried and stored in microfluidic cards within the payload: a wild-type control strain and a radiation sensitive rad51 mutant that is deficient in DSB repairs. Throughout the mission, the microfluidic cards will be rehydrated with growth medium and an indicator dye. Growth rates of each strain will be measured through LED detection of the reduction of the indicator dye, which correlates with DNA repair and the amount of radiation damage accumulated. Results from BioSentinel will be compared to analog experiments on the ISS and on Earth. It is well known that desiccation can damage yeast cells and decrease viability over time. We performed a screen for desiccation-tolerant rad51 strains. We selected 20 re-isolates of rad51 and ran a weekly screen for desiccation-tolerant mutants for five weeks. Our data shows that viability decreases over time, confirming previous research findings. Isolates L2, L5 and L14 indicate desiccation tolerance and are candidates for whole-genome sequencing. More time is needed to determine whether a specific strain is truly desiccation tolerant. Furthermore, we conducted an intracellular trehalose assay to test how intracellular trehalose concentrations affect or protect the mutant strains against desiccation stress. S. cerevisiae cell and reagent concentrations from a previously established intracellular trehalose protocol did not yield significant absorbance measurements, so we tested varying cell and reagent concentrations and determined proper concentrations for successful protocol use.

BioSentinel↗

Biosentinel: Improving Desiccation Tolerance of Yeast Biosensors for Deep-Space Missions

BioSentinel is one of 13 secondary payloads to be deployed on Exploration Mission 1 (EM-1) in 2019. We will use the budding yeast Saccharomyces cerevisiae as a biosensor to determine how deep-space radiation affects living organisms and to potentially quantify radiation levels through radiation damage analysis. Radiation can damage DNA through double strand breaks (DSBs), which can normally be repaired by homologous recombination. Two yeast strains will be air-dried and stored in microfluidic cards within the payload: a wild-type control strain and a radiation sensitive rad51 mutant that is deficient in DSB repairs. Throughout the mission, the microfluidic cards will be rehydrated with growth medium and an indicator dye. Growth rates of each strain will be measured through LED detection of the reduction of the indicator dye, which correlates with DNA repair and the amount of radiation damage accumulated. Results from BioSentinel will be compared to analog experiments on the ISS and on Earth. It is well known that desiccation can damage yeast cells and decrease viability over time. We performed a screen for desiccation-tolerant rad51 strains. We selected 20 re-isolates of rad51 and ran a weekly screen for desiccation-tolerant mutants for five weeks. Our data shows that viability decreases over time, confirming previous research findings. Isolates L2, L5 and L14 indicate desiccation tolerance and are candidates for whole-genome sequencing. More time is needed to determine whether a specific strain is truly desiccation tolerant. Furthermore, we conducted an intracellular trehalose assay to test how intracellular trehalose concentrations affect or protect the mutant strains against desiccation stress. S. cerevisiae cell and reagent concentrations from a previously established intracellular trehalose protocol did not yield significant absorbance measurements, so we tested varying cell and reagent concentrations and determined proper concentrations for successful protocol use.

BioSentinel↗

The Double-Drained Drop: Symmetric Draining of Liquids from Containers with Interior Corners

An analytic solution is found for the late stage draining of a wetting capillary liquid from an interior corner. The solution exploits the symmetry of volumetric sink conditions at opposing ends of such a `double-drained' interior corner flow with applications ranging from liquid recovery in microfluidic devices on earth to liquid fuels scavenging in large fuel tanks aboard spacecraft. At long times t, the liquid depth is h~t^n, the liquid volume is V~ t^(2n), and the maximum volumetric liquid removal rate is Q~t^(2n-1), where n =-1. Representative experiments are conducted at larger length scales aboard the International Space Station and at microfluidic length scales in a terrestrial laboratory. Both sets of experiments confirm the solutions. We show that the approach offers a method to predict maximum drain rates from related geometries where a single drain location provides the required symmetry. We also show that the `fixed length' solution is one of many practical similarity solutions to the governing nonlinear evolution equation for the transient liquid profile along the interior corner. Exponential asymptotic Fourier series solutions are also found for partial corner fillling as well as draining.

microgravity↗

Water/Oil Emulsions with Controlled Droplet Sizes for In Vitro Selection Experiments

In the early history of life, RNA might have had many catalytic functions as ribozymes that do not exist today. To explore this possibility, catalytically active RNAs can be identified by in vitro selection experiments. Some of these experiments are best performed in nanodroplets to prevent diffusion between individual RNA sequences. In order to explore the suitability for the large-scale in emulsio selection of water-in-oil emulsions made by passing a mixture of mineral oil, the emulsifier ABIL-EM90, and a few percent of an aqueous phase through a microfluidizer, we used dynamic light scattering to characterize the size of aqueous droplets dispersed throughout the oil. We found that seven or more passes through the microfluidizer at 8000 psi with close to half molar inorganic salts and 10% polyethylene glycol produced droplets with sizes below 100 nm that were ideal for our purposes. We also identified conditions that would produce larger or smaller droplets, and we demonstrate that the emulsions are stable over weeks and months, which is desirable for different types of in vitro selection experiments.

Douglas Magde↗

The BioSensor Instrument Beyond LEIA: a Versatile Platform for Lunar Biology

Introduction: The BioSensor is a deep-space-compatible automated microfluidic culturing instrument. While originally designed to measure the effects of deep space radiation on yeast growth for the BioSentinel mission, it has the potential to host a diverse range of life science experiments with single- and/or multi-celled organisms and can be adapted to interface with a diverse range of platforms in both crewed and uncrewed settings. It is therefore a leading candidate for hosting life sciences experimentation associated with a lunar surface habitat. BioSensor design: The function of the BioSensor is to monitor the growth and metabolic activity of samples in batch fluidic culture, without the need for crew involvement. The current configuration houses organisms in 16 wells within 16 microfluidic cards, accommodating a total of 256 samples, replicates, and controls. Each well has an optical system including three LEDs and a photodiode detector to measure absorbance at three wavelengths, enabling measurement of optical density, color change in dyes such as alamarBlue, and bioproduction of pigmented compounds. Organisms are loaded into fluidic wells and air-dried for storage during integration, launch, and transit, then activated by the introduction of culture medium from storage bags via manifolds that fill one card at a time. Temperature is controlled by individual card heaters, and timing of all activities (fluidics fills, optical measurements, temperatures) is directed by an experiment script. The self-contained BioSensor payload is roughly 4U in volume; with electrical/mechanical/thermal interface, e.g. for operation on ISS or a lunar lander, as well as a linear energy-transfer (LET) charged-particle radiation spectrometer, the entire system is closer to 6U. BioSentinel and LEIA: Flown on the ISS and in a deep-space free flyer for BioSentinel, the BioSensor has been modified for use in the LEIA mission, including improvements to reduce the sensitivity to lengthy launch delays. LEIA will monitor yeast growth in the radiation and reduced-gravity environment of the lunar surface no earlier than 2026, on a CLPS lander [4]. Changes include accommodating additional culture media and an additional LED color for a new biological assay (bioproduction of carotenoids-- dietary antioxidants), as well as modifications to the housing to allow late-load biology changeout and improved isolation between fluidics and electronics. Future prospects: Future work with the BioSensor, beyond LEIA, will include expanding the range and diversity of organisms and assays accommodated. Preliminary work has demonstrated the growth of Arabidopsis seedlings in BioSensor fluidic cards, including optical measurements of growth rate over time. Minor modifications could allow measurement of phenotypes related to photosynthetic capacity in both plants and cyanobacteria. The experimental capabilities of the BioSensor could be dramatically increased by introducing the capability for fluorescence measurements, and/or the design of novel biological assays using luminescence. The BioSensor can also be adapted for new platforms and experiment settings; in addition to free-flyer, ISS, and CLPS lander, a preliminary design concept has been developed for crewed deployment directly to the lunar surface. The instrument could be accommodated inside a lunar habitat, where its automated operation would make it an excellent candidate for experiments from fundamental investigations into the response of organisms to lunar surface conditions to applied-science purposes such as screening engineered strains of various organisms for bioproduction capability.

J A Lee↗

Yeast strain development to test in-space bioproduction in the Lunar Explorer Instrument for space biology Applications (LEIA) mission

The Lunar Explorer Instrument for space biology Applications (LEIA) is investigating the effects of lunar radiation and gravity on yeast viability, growth, and metabolism. LEIA is part of the CP-22 Commercial Lunar Payload Services (CLPS) surface mission to the south polar region of the Moon. The biological payload will test genetic factors that are likely to influence the tolerance of yeast for deep space and lunar surface radiation. LEIA is also investigating in-space production of β-carotene in bioengineered yeast. This carotenoid is both an antioxidant and pro-vitamin A- an essential human micronutrient. We report progress on engineering carotenoid-expressing strains to test the impacts of strain background and specific genetic variants on growth and production of β-carotene. To test for enhanced sensitivity to the LEIA mission environment, we generated gene knockouts for the RAD51 DNA damage repair locus as well as the SOD1, SOD2, and TSA1 reactive oxygen species (ROS) defense enzymes. We are also generating strains expected to increase tolerance to abiotic stressors and ROS. To be included in the biology payload, each strain needs to satisfy a series of requirements to be compatible with the mission concept of operations. The LEIA mission will conduct experiments using an autonomous light emitting diode optical detection system and microfluidics incubator to quantify growth, metabolism, and carotenoid production. Strains must produce sufficient carotenoids for bioproduction to be detectable with this optical system. Cells will be loaded into microfluidics cards, desiccated, and stored for 8-12 months prior to the initiation of lunar surface operations. The CLPS lander will operate for one lunar day, and strains will need to grow to stationary phase within 96 hours to ensure that telemetry of LEIA data to Earth can be completed. Genetic variants also need to display expected phenotypes within these optical detection, storage, and growth cycle constraints.

Yeast Engineering↗

Lab-on-a-Chip Based Protein Crystallization

We are developing a novel technique with which we will grow protein crystals in very small volumes, utilizing chip-based, microfluidic ("LabChip") technology. This development, which is a collaborative effort between NASA's Marshall Space Flight Center and Caliper Technologies Corporation, promises a breakthrough in the field of protein crystal growth. Our initial results obtained from two model proteins, Lysozyme and Thaumatin, show that it is feasible to dispense and adequately mix protein and precipitant solutions on a nano-liter scale. The mixtures have shown crystal growth in volumes in the range of 10 nanoliters to 5 microliters. In addition, large diffraction quality crystals were obtained by this method. X-ray data from these crystals were shown to be of excellent quality. Our future efforts will include the further development of protein crystal growth with LabChip(trademark) technology for more complex systems. We will initially address the batch growth method, followed by the vapor diffusion method and the liquid-liquid diffusion method. The culmination of these chip developments is to lead to an on orbit protein crystallization facility on the International Space Station. Structural biologists will be invited to utilize the on orbit Iterative Biological Crystallization facility to grow high quality macromolecular crystals in microgravity.

vanderWoerd, Mark J.↗

Micro-Detection System for Determination of the Biotic or Abiotic Origin of Amino Acids

The research involved the development of a breadboard version of a spacecraft based system for the detection of amino acid chirality (handedness) on solar system bodies. The design concept has three distinct components: a sublimation chamber for the release of amino acids from an acquired sample; a microchip based capillary electrophoresis (CE) chip for the separation of amino acids and their enantiomers; and a fluorescent based detection system. In addition, we have investigated the use of a microfluidics system for the extraction of amino acids in samples in which sublimation has proven to be problematic. This is a joint project carried out at the Scripps Institution of Oceanography (SIO), University of California at San Diego; the Jet Propulsion Laboratory (JPL), Pasadena; and the Department of Chemistry, University of California, Berkeley.

Bada, Jeffrey L.↗

Experiences with Lab-on-a-chip Technology in Support of NASA Supported Research

Under the auspices of the Microgravity Sciences and Application Department at Marshall Space Flight Center, we have custom designed and fabricated a lab-on-a-chip (LOC) device, along with Caliper Technologies, for macromolecular crystal growth. The chip has been designed to deliver specified proportions of up-to five various constituents to one of two growth wells (on-chip) for crystal growth. To date, we have grown crystals of thaumatin, glucose isomerase and appoferitin on the chip. The LOC approach offered many advantages that rendered it highly suitable for space based hardware to perform crystal growth on the International Space Station. The same hardware that was utilized for the crystal growth investigations, has also been used by researchers at Glenn Research Center to investigate aspects of microfluidic phenomenon associated with two-phase flow. Additionally, our LOCAD (Lab-on-a-chip Application Development) team has lent its support to Johnson Space Center s Modular Assay for Solar System Exploration project. At present, the LOCAD team is working on the design and build of a unique lab-on-a-chip breadboard control unit whose function is not commercially available. The breadboard can be used as a test bed for the development of chip size labs for environmental monitoring, crew health monitoring assays, extended flight pharmacological preparations, and many more areas. This unique control unit will be configured for local use and/or remote operation, via the Internet, by other NASA centers. The lab-on-a-chip control unit is being developed with the primary goal of meeting Agency level strategic goals.

Monaco, Lisa↗

Challenges in Physics of Biocrystals and Biocrystallization

Selected problems in biocrystal mechanics(1), nucleation(2) and growth(3) will be addressed. (1) Elastic moduli of protein crystals found from triple bonding, rod vibrations, ultrasound speed and Brillion light scattering vary in a wide range of 0.3 - 3 GPa. This diversity comes from behaviour of intracrystalline liquid. Namely, liquid flow through the narrow intermolecular channels between compressed and expanded regions within an inhomogeneously deformed crystal was considered. The deformation comes from bending or ultrasound wave propagation. (2) Wide scattering in the number of crystals nucleated in the batch technique may come from liquid flow turbulence associated with pipetting; the Reynolds number these injections reaches 10(exp 3). (3) Poor reproducibility in crystal size and, probably, perfection is supposed to come from a variety of growth conditions in the same batch. Growth in a kinetic growth mode in laminar flow, e.g., in a microfluidic device, would allow to better understand growth kinetics and defect formation.

Chernov, Alexander A.↗

Poly(ethylene glycol) hydrogel microstructures encapsulating living cells

We present an easy and effective method for the encapsulation of cells inside PEG-based hydrogel microstructures fabricated using photolithography. High-density arrays of three-dimensional microstructures were created on substrates using this method. Mammalian cells were encapsulated in cylindrical hydrogel microstructures of 600 and 50 micrometers in diameter or in cubic hydrogel structures in microfluidic channels. Reducing lateral dimension of the individual hydrogel microstructure to 50 micrometers allowed us to isolate 1-3 cells per microstructure. Viability assays demonstrated that cells remained viable inside these hydrogels after encapsulation for up to 7 days.

Non-NASA Center↗

Contactless conductivity detector for microchip capillary electrophoresis

A microfabricated electrophoresis chip with an integrated contactless conductivity detection system is described. The new contactless conductivity microchip detector is based on placing two planar sensing aluminum film electrodes on the outer side of a poly(methyl methacrylate) (PMMA) microchip (without contacting the solution) and measuring the impedance of the solution in the separation channel. The contactless route obviates problems (e.g., fouling, unwanted reactions) associated with the electrode-solution contact, offers isolation of the detection system from high separation fields, does not compromise the separation efficiency, and greatly simplifies the detector fabrication. Relevant experimental variables, such as the frequency and amplitude of the applied ac voltage or the separation voltage, were examined and optimized. The detector performance was illustrated by the separation of potassium, sodium, barium, and lithium cations and the chloride, sulfate, fluoride, acetate, and phosphate anions. The response was linear (over the 20 microM-7 mM range) and reproducible (RSD = 3.4-4.9%; n = 10), with detection limits of 2.8 and 6.4 microM (for potassium and chloride, respectively). The advantages associated with the contactless conductivity detection, along with the low cost of the integrated PMMA chip/detection system, should enhance the power and scope of microfluidic analytical devices.

NASA Center JPL↗

Two-Photon Flow Cytometry

Flow cytometry is a powerful technique for obtaining quantitative information from fluorescence in cells. Quantitation is achieved by assuring a high degree of uniformity in the optical excitation and detection, generally by using a highly controlled flow such as is obtained via hydrodynamic focusing. In this work, we demonstrate a two-beam, two- channel detection and two-photon excitation flow cytometry (T(sup 3)FC) system that enables multi-dye analysis to be performed very simply, with greatly relaxed requirements on the fluid flow. Two-photon excitation using a femtosecond near-infrared (NIR) laser has the advantages that it enables simultaneous excitation of multiple dyes and achieves very high signal-to-noise ratio through simplified filtering and fluorescence background reduction. By matching the excitation volume to the size of a cell, single-cell detection is ensured. Labeling of cells by targeted nanoparticles with multiple fluorophores enables normalization of the fluorescence signal and thus ratiometric measurements under nonuniform excitation. Quantitative size measurements can also be done even under conditions of nonuniform flow via a two-beam layout. This innovative detection scheme not only considerably simplifies the fluid flow system and the excitation and collection optics, it opens the way to quantitative cytometry in simple and compact microfluidics systems, or in vivo. Real-time detection of fluorescent microbeads in the vasculature of mouse ear demonstrates the ability to do flow cytometry in vivo. The conditions required to perform quantitative in vivo cytometry on labeled cells will be presented.

Zhog, Cheng Frank↗

Integration of a Micro-Chip Amino Acid Chirality Detector into the MOD Instrument Concept

The MOD (Mars Organic Detector) instrument concept consists of a sublimation apparatus for organic compound isolation connected to a microfabricated microfluidic analyzer containing a sipper, pumps and a separation channel for organic compound characterization. The target organic compounds are amino acids and polycyclic aromatic hydrocarbons (PAHs). Solid samples are placed within the sublimation apparatus and heated to release organic compounds which sublime onto a cold finger. Half of the cold finger is coated with fluorescamine. which reacts with amino acids and other primary amines to generate an intense fluorescent derivative while the other half is uncoated and is used to directly detect PAH fluorescence, A capillary sipper is then used to dissolve and sample the labeled amino acids and integrated microfabricated pumps transport the labeled amino acids to the chip for analysis. The sample is separated using capillary zone electrophoresis (CZE) together with chiral dextrins to determine amino acid composition and chirality. During the grant period, the following steps have been completed toward the development of a robust instrument and chemistry.

Bada, Jeffrey L.↗

Miniaturized multiplex label-free electronic chip for rapid nucleic acid analysis based on carbon nanotube nanoelectrode arrays

BACKGROUND: Reducing cost and time is the major concern in clinical diagnostics, particularly in molecular diagnostics. Miniaturization technologies have been recognized as promising solutions to provide low-cost microchips for diagnostics. With the recent advancement in nanotechnologies, it is possible to further improve detection sensitivity and simplify sample preparation by incorporating nanoscale elements in diagnostics devices. A fusion of micro- and nanotechnologies with biology has great potential for the development of low-cost disposable chips for rapid molecular analysis that can be carried out with simple handheld devices. APPROACH: Vertically aligned multiwalled carbon nanotubes (MWNTs) are fabricated on predeposited microelectrode pads and encapsulated in SiO2 dielectrics with only the very end exposed at the surface to form an inlaid nanoelectrode array (NEA). The NEA is used to collect the electrochemical signal associated with the target molecules binding to the probe molecules, which are covalently attached to the end of the MWNTs. CONTENT: A 3 x 3 microelectrode array is presented to demonstrate the miniaturization and multiplexing capability. A randomly distributed MWNT NEA is fabricated on each microelectrode pad. Selective functionalization of the MWNT end with a specific oligonucleotide probe and passivation of the SiO2 surface with ethylene glycol moieties are discussed. Ru(bpy)2+ -mediator-amplified guanine oxidation is used to directly measure the electrochemical signal associated with target molecules. SUMMARY: The discussed MWNT NEAs have ultrahigh sensitivity in direct electrochemical detection of guanine bases in the nucleic acid target. Fewer than approximately 1000 target nucleic acid molecules can be measured with a single microelectrode pad of approximately 20 x 20 microm2, which approaches the detection limit of laser scanners in fluorescence-based DNA microarray techniques. MWNT NEAs can be easily integrated with microelectronic circuitry and microfluidics for development of a fully automated system for rapid molecular analysis with minimum cost.

Carbon↗