Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROSPHERES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Establishment of time‐resolved fluoroimmunoassay of IgG4 based on magnetic microspheres

Abstract Background The abnormal increase in serum IgG4 level is an important clinical symptom of IgG4‐related disease (IgG4‐RD), and the detection of serum IgG4 level is a powerful tool for the diagnosis of IgG4‐RD. This study was conducted to establish a simple and rapid immunoassay for the determination of human serum IgG4 levels. Methods Based on the competition method, a novel immunoassay was established for the determination of human serum IgG4 using a combination of time‐resolved fluoroimmunoassay (TRFIA) and magnetic microspheres. IgG4 was coupled with magnetic microspheres and competed with IgG4 in the samples to bind the Eu 3+ ‐labeled anti‐IgG4 antibody. The immunocomplex was separated and washed in a magnetic field, and the fluorescence counts were measured according to the number of dissociated europium ions. Results The analytical sensitivity of IgG4‐TRFIA based on magnetic microspheres was 0.006 g/L, and the detection range was 0.006–20 g/L under optimal conditions. The precision, recovery, and specificity of this immunoassay were demonstrated to be acceptable. The clinical application of IgG4‐TRFIA based on magnetic microspheres was evaluated and compared with that of immunonephelometry. The results showed that the two detection methods had a good correlation, with a correlation coefficient of .9871. Conclusion IgG4‐TRFIA based on magnetic microspheres has the advantages of high sensitivity, wide detection range, and short analysis time and has the potential to become a useful tool for the diagnosis of IgG4‐RD.

Wu, Qingqing↗

Arterial Distribution of Calibrated Tris-Acryl Gelatin and Polyvinyl Alcohol Embolization Microspheres in Sheep Uterus

The purpose of this study was to compare, after embolization, the distribution in the uterine arterial vasculature of tris-acryl gelatin microspheres (TGMS) and polyvinyl alcohol microspheres (PVAMS). A limited bilateral uterine artery embolization was performed in six adult sheep under fluoroscopic control by injecting in each uterine artery 0.25 ml of 500- to 700-{mu}m TGMS of PVAMS suspended in 50/50 saline/contrast medium. Sacrifices were performed 1 week after embolization and uteri were analyzed histologically. The number and size of microspheres and vessels were measured, as well as the histological location according to a classification in four zones of the uterus. One hundred sixty-five vessels (69 vessels occluded with TGMS and 96 vessels occluded with PVAMS) were measured. The size of the occluded vessels decreased significantly from proximal to distal zones of the uterine vasculature (P < 0.0001). The location of TGMS and PVAMS within the vasculature was significantly different (P < 0.0001) since PVAMS blocked significantly more distally than TGMS. Deformation of the microspheres within the tissue was greater for PVAMS (18.0% {+-} 12.3%) than for TGMS (8.7% {+-} 9.2%) (P < 0.0001). In conclusion, PVAMS have a more distal distribution in the sheep uterine vasculature, compared to TGMS. Such differences in partition, already described in the kidney embolization model, can ultimately explain the different clinical outcome reported with these two types of microspheres in uterine fibroid embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Production of 75–150 µm and <75 µm of cerium dioxide microspheres in high yield and throughput using the internal gelation process

Hundreds of grams of calcined cerium dioxide (CeO 2 ) microspheres were produced in this paper using the internal gelation process with a focus on 75–150 µm and <75 µm diameter sizes. To achieve these small sizes, a modified internal gelation system was employed, which utilized a two-fluid nozzle, two static mixers for turbulent flow, and 2-ethyl-1-hexanol as the medium for gel formation at 333–338 K. This effort generated over 400 g of 75–150 µm and 300 g of <75 µm CeO 2 microspheres. The typical product yields for the 75–150 µm and <75 µm microspheres that were collected and processed were 72 and 99%, respectively, with a typical throughput of 66–73 g of CeO 2 microspheres per test, which could generate a maximum of 78.6 g of CeO 2 . The higher yield of very small cerium spheres led to challenges and modifications, which are discussed in detail. Finally, as expected, when the <75 µm microspheres were targeted, losses to the system increased significantly.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Use of boiled hexamethylenetetramine and urea to increase the porosity of cerium dioxide microspheres formed in the internal gelation process

Cerium dioxide (CeO 2 ) is a commonly used simulant for plutonium dioxide and for plutonium (Pu) in a mixed uranium (U) and Pu oxide [(U, Pu)O 2 ] in nuclear fuel development. This effort developed CeO 2 microspheres with different porosities and diameters for use in a crush-strength study. The internal gelation technique has produced CeO 2 microspheres with limited initial porosity. When an equal molar solution of urea and hexamethylenetetramine (HMTA) is gently boiling for 1 hr and used in the gelation process, the crystallite size and porosity of mixed U and thorium oxide microspheres and the (U, Pu)O 2 microspheres increased significantly. In this study with cerium, the combination of ammonium cerium nitrate and 1-h boiled HMTA-urea failed to produce a stable feed broth. However, when the 1-h heated HMTA-urea was combined with unheated HMTA-urea in 1 to 3 volume ratio or the boiling time of the HMTA-urea was reduced to 15-20 min, a stable solution of HMTA, urea, and Ce was formed at 273 K. This new Ce solution produced CeO 2 microspheres with much higher initial porosities. Intermediate porosities were possible when the heated HMTA/urea was aged prior to use.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Key process parameters to modify the porosity of cerium dioxide microspheres formed in the internal gelation process

Recently, an internal gelation study demonstrated that the use of heated urea and hexamethylenetetramine can have a pronounced impact on the porosity and sintering characteristics of cerium dioxide (CeO 2 ) microspheres. This effort has identified process variables that can significantly change the initial porosity of the CeO 2 microspheres with slight modifications. A relatively small difference in the sample preparation of cerium ammonium nitrate and ammonium hydroxide solution had a large reproducible impact on the porosity and slow pour density of the produced microspheres. Increases in the gelation temperature as small as 0.5 K also produced a noticeable increase in the slow pour density. If the gelation temperature was increased too high, the use of the heated hexamethylenetetramine and urea was no longer observed to be effective in increasing the porosity of the CeO 2 microspheres. In conclusion, the final process variable was the amount of dispersing agent, Span™ 80, which can increase the slow pour density and produce significantly smaller microspheres.

36 MATERIALS SCIENCE↗

Controlled synthesis and gas sensing properties of In{sub 2}O{sub 3} with different phases from urchin-like InOOH microspheres

Highlights: • Preparation of nanostructured In{sub 2}O{sub 3} microspheres. • Morphology and phase control of In{sub 2}O{sub 3}. • Gas sensors based on the In{sub 2}O{sub 3} microspheres exhibit excellent sensing properties for the detection of formaldehyde. - Abstract: Urchin-like InOOH microspheres were successfully prepared by a convenient and controllable method. Such experimental parameters as solvents and complexing reagents on the formation of the urchin-like InOOH microspheres were investigated. Scanning electron microscopy, X-ray diffraction and infrared spectroscopy were employed to investigate the evolution process of the urchin-like InOOH precursors. Furthermore, the formation mechanism of the urchin-like InOOH microspheres was proposed. By annealing the urchin-like InOOH precursor at different temperatures under ambient pressure, rhombohedral corundum-type indium oxide (rh-In{sub 2}O{sub 3}), cubic bixbyite-type indium oxide (c-In{sub 2}O{sub 3}) and mixed phases of rh-In{sub 2}O{sub 3} and c-In{sub 2}O{sub 3} were obtained. The gas sensing properties of the prepared In{sub 2}O{sub 3} samples were examined. It was found that the sensors based on the prepared In{sub 2}O{sub 3} samples exhibited excellent response and selectivity to formaldehyde.

36 MATERIALS SCIENCE↗

Synthesis of phase-pure U 2 N 3 microspheres and its decomposition into UN

Uranium mononitride (UN) is important as a nuclear fuel. Fabrication of UN in its microspherical form also has its own merits since the advent of the concept of accident-tolerant fuel, where UN is being considered as a potential fuel in the form of TRISO particles. But, not many processes have been well established to synthesize kernels of UN. Therefore, a process for synthesis of microspherical UN with a minimum amount of carbon is discussed herein. First, a series of single-phased microspheres of uranium sesquinitride (U 2 N 3 ) were synthesized by nitridation of UO 2 +C microspheres at a few different temperatures. Resulting microspheres were of low-density U 2 N 3 and decomposed into low-density UN. The variation of density of the synthesized sesquinitrides as a function of its chemical composition indicated the presence of extra (interstitial) nitrogen atoms corresponding to its hyperstoichiometry, which is normally indicated as α-U 2 N 3 . Average grain sizes of both U 2 N 3 and UN varied in a range of 1–2.5 μm. In addition, these had a considerably large amount of pore spacing, indicating the potential sinterability of UN toward its use as a nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal response of chalcogenide microsphere resonators

A chalcogenide microsphere resonator (CMR) used for temperature sensing is proposed and demonstrated. The CMR is fabricated using a simple technique of heating chalcogenide glass and allowing the molten glass to form a microsphere on the waist of a tapered silica fibre. The thermal responses of the CMR is investigated and compared to that of a single-mode-fibre (SMF) based microsphere resonator. It is observed that the CMR sensitivity to ambient temperature changes is 8 times higher than that of the SMF-based microsphere resonator. Heating the chalcogenide microsphere with a laser beam periodically turned on and off shows periodic shifts in the transmission spectrum of the resonator. By injecting an intensity-modulated cw signal through the resonator a thermal relaxation time of 55 ms is estimated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detecting Distance between Injected Microspheres and Target Tumor via 3D Reconstruction of Tissue Sections

One treatment increasing in use for solid tumors in the liver is radioembolization via the delivery of 90Y microspheres to the vascular bed within or near the location of the tumor. It is desirable as part of the treatment for the microspheres to embed preferentially in or near the tumor. This work details an approach for analyzing the deposition of microspheres with respect to the location of the tumor. The approach used is based upon thin-slice serial sectioning of the tissue sample, followed by high resolution imaging, microsphere detection, and 3-D reconstruction of the tumor surface. Distance from the microspheres to the tumor was calculated using a fast deterministic point inclusion method.

Carson, James P.↗

Thermal expansion of an epoxy-glass microsphere composite

The thermal expansion of a composite of epoxy (diglycidyl ether of bisphenol A) and solid glass microspheres was investigated. The microspheres had surfaces which were either untreated or treated with a silicone release agent, an epoxy coupling agent, or a general purpose silane coupling agent. Both room temperature (about 300 K) and elevated temperature (about 475 K) cures were used for the epoxy. Two microsphere size ranges were used, about 50 microns, which is applicable in filled moldings, and about 125 microns, which is applicable as bond line spacers. The thermal expansion of the composites was measured from 300 to 350 K or from 300 to 500 K, depending on the epoxy cure temperature. Measurements were made on composites containing up to .6 volume fraction microspheres. Two predictive models, which required only the values of thermal expansion of the polymer and glass and their specific gravities, were tested against the experimental data. A finite element analysis was made of the thermal strain of a composite cell containing a single microsphere surrounded by a finite-thickness interface.

Price, H. L.↗

Acrolein Microspheres Are Bonded To Large-Area Substrates

Reactive cross-linked microspheres produced under influence of ionizing radiation in aqueous solutions of unsaturated aldehydes, such as acrolein, with sodium dodecyl sulfate. Diameters of spheres depend on concentrations of ingredients. If polystyrene, polymethylmethacrylate, or polypropylene object immersed in solution during irradiation, microspheres become attached to surface. Resulting modified surface has grainy coating with reactivity similar to free microspheres. Aldehyde-substituted-functional microspheres react under mild conditions with number of organic reagents and with most proteins. Microsphere-coated macrospheres or films used to immobilize high concentrations of proteins, enzymes, hormones, viruses, cells, and large number of organic compounds. Applications include separation techniques, clinical diagnostic tests, catalytic processes, and battery separators.

Rembaum, Alan↗

Integrated Cryogenic Experiment (ICE) microsphere investigation

The main objective is to determine the performance of microsphere insulation in a 0-g environment and compare its performance to reference insulations such as multilayer insulation. The Lockheed Helium Extended-Life Dewar (HELD) is used to provide superfluid-helium cold sink for the experiment. The use of HELD allows the low-g dynamic properties of Passive Orbital Disconnect Struts (PODS) to be characterized and provides a flight demonstration of the PODS system. The thermal performance of microspheres in 1 and 0 g was predicted, a flight experiment was designed to determine microsphere thermal performance, and the interface was also designed between the experimental package and the shuttle through HELD and the Hitchhiker-M carrier. A single test cell was designed and fabricated. The cell was filled with uncoated glass microspheres and tested with a liquid-nitrogen cold sink. The data were found to agree with predictions of microsphere performance in 1 g.

Spradley, I.↗

Microspheres

Vital information on a person's physical condition can be obtained by identifying and counting the population of T-cells and B-cells, lymphocytes of the same shape and size that help the immune system protect the body from the invasion of disease. The late Dr. Alan Rembaum developed a method for identifying the cells. The method involved tagging the T-cells and B-cells with microspheres of different fluorescent color. Microspheres, which have fluorescent dye embedded in them, are chemically treated so that they can link with antibodies. With the help of a complex antibody/antigen reaction, the microspheres bind themselves to specific 'targets,' in this case the T-cells or B-cells. Each group of cells can then be analyzed by a photoelectronic instrument at different wavelengths emitted by the fluorescent dyes. Same concept was applied to the separation of cancer cells from normal cells. Microspheres were also used to conduct many other research projects. Under a patent license Magsphere, Inc. is producing a wide spectrum of microspheres on a large scale and selling them worldwide for various applications.

Source record↗

Modeling the Formation of Polyimide Microspheres

High temperature polyimide microspheres have been developed from polyimide solid residuum by a simple inflation process. Microspheres have been fabricated from several polyimide precursors through the use of a circulating air oven. Microsphere formation and final physical property characterization have been limited to simple mechanical and thermal testing. The present paper focuses on developing an understanding of microsphere formation through simple geometric rules for an incompressible polymeric material and microscopic observations of precursor residuum inflation. Inflation kinematics of the hollow polyimide microspheres as a function of time and temperature is discussed.

Pipes, R. B.↗

Metal containing polymeric functional microspheres

Polymeric functional microspheres containing metal or metal compounds are formed by addition polymerization of a covalently bondable olefinic monomer such as hydroxyethylmethacrylate in the presence of finely divided metal or metal oxide particles, such as iron, gold, platinum or magnetite, which are embedded in the resulting microspheres. The microspheres can be covalently bonded to chemotherapeutic agents, antibodies, or other proteins providing a means for labeling or separating labeled cells. Labeled cells or microspheres can be concentrated at a specific body location such as in the vicinity of a malignant tumor by applying a magnetic field to the location and then introducing the magnetically attractable microspheres or cells into the circulatory system of the subject. Labeled cells can be separated from a cell mixture by applying a predetermined magnetic field to a tube in which the mixture is flowing. After collection of the labeled cells, the magnetic field is discontinued and the labeled sub-cell population recovered.

Yen, Shiao-Ping S.↗

Solvent/Non-Solvent Sintering To Make Microsphere Scaffolds

A solvent/non-solvent sintering technique has been devised for joining polymeric microspheres to make porous matrices for use as drug-delivery devices or scaffolds that could be seeded with cells for growing tissues. Unlike traditional sintering at elevated temperature and pressure, this technique is practiced at room temperature and pressure and, therefore, does not cause thermal degradation of any drug, protein, or other biochemical with which the microspheres might be loaded to impart properties desired in a specific application. Also, properties of scaffolds made by this technique are more reproducible than are properties of comparable scaffolds made by traditional sintering. The technique involves the use of two miscible organic liquids: one that is and one that is not a solvent for the affected polymer. The polymeric microspheres are placed in a mold having the size and shape of the desired scaffold, then the solvent/non-solvent mixture is poured into the mold to fill the void volume between the microspheres, then the liquid mixture is allowed to evaporate. Some of the properties of the resulting scaffold can be tailored through choice of the proportions of the liquids and the diameter of the microspheres.

Laurencin, Cato T.↗

Polarization Dependent Whispering Gallery Modes in Microspheres

A tunable resonant system is provided and includes a microsphere that receives an incident portion of a light beam generated via a light source, the light beam having a fundamental mode, a waveguide medium that transmits the light beam from the light source to the microsphere, and a polarizer disposed in a path of the waveguide between the light source and the microsphere. The incident portion of the light beam creates a fundamental resonance inside the microsphere. A change in a normalized frequency of the wavelength creates a secondary mode in the waveguide and the secondary mode creates a secondary resonance inside the microsphere.

Adamovsky, Grigory↗

Microsphere Plutonium-238 Oxide Fuel to Revolutionize New Radioisotope Power Systems and Heat Sources for Planetary Exploration

Microsphere 238PuO2 fuels have potential to provide performance and safety enhancements for future radioisotope heat and power systems (RPS) as well as enable more flexible and compact RPS designs. Improvements in RPS specific power and more flexible geometries were recently investigated by JPL and PNNL as part of a study on cryobot devices for exploring Ocean Worlds. Missions to penetrate ice and explore oceans, such as on Europa, will require RPS with high specific power within the vehicle to provide both heat and power. Such missions will be mass-constrained, and the energy required to penetrate the ice is highly dependent on cryobot size. Therefore, compact RPS geometries are needed to maximize heat and power while minimizing 238Pu inventory. Microsphere-based heat sources are an attractive way to obtain flexible geometries and high volumetric power loadings because they can fill a region of any size and shape provided fuel temperatures are kept below a threshold and launch/re-entry safety are not compromised. The sol-gel technique to produce 238PuO2 microsphere particles for heat sources has the benefit of preventing dust generation, as opposed to the current 238PuO2 powder/pellet processing method, reducing hazards in the fuel fabrication line. Microspheres can also be individually coated to enhance thermal conductivity, and/or reduce the likelihood of 238PuO2 fuel dispersal in an accident. Although PNNL has produced 238PuO2 microspheres using the sol-gel method, the application of coatings and their integrity over time has yet to be investigated. Continued R&D could demonstrate the feasibility of advanced, microspherebased heat sources and provide baseline data for planning future missions requiring new RPS with different heat source configurations.

Fleurial, Jean-Pierre↗