Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROWAVE APPARATUS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Microwave absorption by a lossy dielectric sphere in a rectangular cavity

A new theory of absorption of microwave power by a lossy dielectric sphere in a resonant rectangular chamber is developed here. In this treatment, resonant modes of the cavity are resolved into traveling plane-wave fields, and Mie's theory of scattering and absorption of a plane electromagnetic wave by a sphere is utilized. The fields in the cavity containing the sphere are found by superposition of results for the individual scattering problem for each traveling plane wave. Absorbed power is then calculated by evaluating the time-averaged Poynting vector and integrating over the surface of the sphere. Applications of microwave power absorption are discussed, with particular emphasis on processing of materials. Numerical studies based on the newly derived formulas are presented. The results exhibit the manner in which microwave absorption is influenced by a number of different experimentally controllable parameters. The examples considered were chosen with a view toward designing experiments and apparatus for containerless processing of materials in the microgravity environment of space.

Jackson, H. W.↗

Studies of Elementary Reactions of Chemical Importance in the Atmospheres of Planets

The methyl self-reaction was studied at T = 298 K and 202 K and at three different pressures, P = 0.5, 1.0, and 2.1 Torr. The experimental measurements were performed in our discharge flow-mass spectrometer (DF-MS) apparatus. The methyl radicals were generated by the reaction of F with methane. Passing a mixture of molecular fluorine, F2, in helium through a microwave cavity generated the atomic fluorine reagent. The atomic F enters the flow tube through a rear port on the flow tube. The methane reagent enters the flow tube through a movable injector located coaxial in the flow tube. The decay of methyl radical signal was monitored at a mass/charge ratio (m/z) of 15 as a function of the injector distance. To minimize secondary chemistry from the reaction CH3 + F to CH2 + HF the initial [CH4](sub 0)/[F](sub 0) was above 37.0 and typically 100. This ensures a 1:1 relationship between initial [F] and [CH3]. A titration of F with excess Cl2 yields the initial [F](sub 0). Our experimental methodology to accurately measure the mass spectrometer scaling factor, i.e., the relationship between initial signal and [CH3](sub 0) has been improved. Now we measure the CH3 signal decay under exponential decay conditions at low initial [F](sub 0), 3x10(exp 11) molecule/cc, in the presence of Cl2. This minimizes the second-order decay contributed by the CH3 self-reaction and a simple extrapolation of the 1n(signal) vs time plot to t = 0 gives the initial signal. This provides the desired relationship between initial signal at 15 amu and [CH3](sub 0). The resulting calibration is then applied to the observed decay of the CH3 signal at high concentrations of CH3 assuming linearity of this scaling factor.

Nesbitt, Fred L.↗

Two-Photon Laser-Induced Fluorescence O and N Atoms for the Study of Heterogeneous Catalysis in a Diffusion Reactor

Advanced laser-based diagnostics have been developed to examine catalytic effects and atom/surface interactions on thermal protection materials. This study establishes the feasibility of using laser-induced fluorescence for detection of O and N atom loss in a diffusion tube to measure surface catalytic activity. The experimental apparatus is versatile in that it allows fluorescence detection to be used for measuring species selective recombination coefficients as well as diffusion tube and microwave discharge diagnostics. Many of the potential sources of error in measuring atom recombination coefficients by this method have been identified and taken into account. These include scattered light, detector saturation, sample surface cleanliness, reactor design, gas pressure and composition, and selectivity of the laser probe. Recombination coefficients and their associated errors are reported for N and O atoms on a quartz surface at room temperature.

Pallix, Joan B.↗

EPR Imaging at a Few Megahertz Using SQUID Detectors

An apparatus being developed for electron paramagnetic resonance (EPR) imaging operates in the resonance-frequency range of about 1 to 2 MHz well below the microwave frequencies used in conventional EPR. Until now, in order to obtain sufficient signal-to-noise radios (SNRs) in conventional EPR, it has been necessary to place both detectors and objects to be imaged inside resonant microwave cavities. EPR imaging has much in common with magnetic resonance imaging (MRI), which is described briefly in the immediately preceding article. In EPR imaging as in MRI, one applies a magnetic pulse to make magnetic moments (in this case, of electrons) precess in an applied magnetic field having a known gradient. The magnetic moments precess at a resonance frequency proportional to the strength of the local magnetic field. One detects the decaying resonance-frequency magnetic- field component associated with the precession. Position is encoded by use of the known relationship between the resonance frequency and the position dependence of the magnetic field. EPR imaging has recently been recognized as an important tool for non-invasive, in vivo imaging of free radicals and reduction/oxidization metabolism. However, for in vivo EPR imaging of humans and large animals, the conventional approach is not suitable because (1) it is difficult to design and construct resonant cavities large enough and having the required shapes; (2) motion, including respiration and heartbeat, can alter the resonance frequency; and (3) most microwave energy is absorbed in the first few centimeters of tissue depth, thereby potentially endangering the subject and making it impossible to obtain adequate signal strength for imaging at greater depth. To obtain greater penetration depth, prevent injury to the subject, and avoid the difficulties associated with resonant cavities, it is necessary to use lower resonance frequencies. An additional advantage of using lower resonance frequencies is that one can use weaker applied magnetic fields: For example, for a resonance frequency of 1.4 MHz, one needs a magnetic flux density of 0.5 Gauss approximately the flux density of the natural magnetic field of the Earth.

Hahn, Inseob↗

Apparatus for hydrogen and carbon production via carbon aerosol-catalyzed dissociation of hydrocarbons

A novel process and apparatus is disclosed for sustainable, continuous production of hydrogen and carbon by catalytic dissociation or decomposition of hydrocarbons at elevated temperatures using in-situ generated carbon particles. Carbon particles are produced by decomposition of carbonaceous materials in response to an energy input. The energy input can be provided by at least one of a non-oxidative and oxidative means. The non-oxidative means of the energy input includes a high temperature source, or different types of plasma, such as, thermal, non-thermal, microwave, corona discharge, glow discharge, dielectric barrier discharge, or radiation sources, such as, electron beam, gamma, ultraviolet (UV). The oxidative means of the energy input includes oxygen, air, ozone, nitrous oxide (NO.sub.2) and other oxidizing agents. The method, apparatus and process of the present invention is applicable to any gaseous or liquid hydrocarbon fuel and it produces no or significantly less CO.sub.2 emissions compared to conventional processes.

Muradov, Nazim Z.↗

Measurement of surface microtopography using helicopter-mounted stereo film cameras and two stereo matching techniques

A common problem in acquiring ground-truth data for use in microwave interaction modeling is the capture of surface roughness data that are both sampled at distances comparable to a fraction of the wavelength and extensive enough to represent the surface statistics in at least one resolution cell of the microwave remote sensor used. A technique has been developed for acquiring the necessary photogrammetric data using twin 70-mm film cameras mounted on a helicopter boom. The apparatus is described, and the accuracy with which ground surface roughness can be characterized using this device is estimated. Both standard and cross-correlation methods were used for data reduction. Stereogrammetry is compared with a completely automated image-matching technique. Dense disparity images were generated from the helicopter stereo pairs. Using interior orientation parameters supplied by the camera manufacturers, and assuming that exterior orientation parameters remain constant between control target and test field photography, an extremely dense DEM (digital elevation model) for a test field has been derived. Results are compared, and accuracy estimates are presented.

Wall, S. D.↗

Improved apparatus for trapped radical and other studies down to 1.5 K

A Dewar system and associated equipment for electron paramagnetic resonance (EPR) studies of trapped free radicals and other optical or irradiation experiments are described. The apparatus is capable of reaching a temperature of 1.5 K and transporting on the order of 20 W per K temperature gradient; its principal advantages are for use at pumped cryogen temperatures and for experiments with large heat inputs. Two versions of the apparatus are discussed, one of which is designed for EPR in a rectangular cavity operating in a TE(102) mode and another in which EPR is performed in a cylindrical microwave cavity.

Woollam, J. A.↗

Near-millimeter spectrum of the microwave background

A description is given of a method for the measurement of the cosmic microwave background (CMB) spectrum. A helium-cooled, balloon-borne spectrophotometer was used to measure the emission spectrum of the night sky over the frequency range 1.7-40/cm. The apparatus was calibrated using a blackbody source at a variety of temperatures both before and after the flight. It is shown that the spectrum of the CMB peaks at 6/cm and is approximately that of a blackbody out to several times that frequency. The measured flux is also found to be equivalent to that from a blackbody in the temperature range from 2.88 to 3.09 K. The data set resulting from the combination of these measurements with previous observations of the CMB covers three decades in frequency, and is compared with various CMB models.

Woody, D. P.↗

CAT altitude avoidance system

A method and apparatus are provided for indicating the altitude of the tropopause or of an inversion layer wherein clear air turbulence (CAT) may occur, and the likely severity of any such CAT, includes directing a passive microwave radiometer on the aircraft at different angles with respect to the horizon. The microwave radiation measured at a frequency of about 55 GHz represents the temperature of the air at an ""average'' range of about 3 kilometers, so that the sine of the angle of the radiometer times 3 kilometers equals the approximate altitude of the air whose temperature is measured. A plot of altitude (with respect to the aircraft) versus temperature of the air at that altitude, can indicate when an inversion layer is present and can indicate the altitude of the tropopause or of such an inversion layer. The plot can also indicate the severity of any CAT in an inversion layer. If CAT has been detected in the general area, then the aircraft can be flown at an altitude to avoid the tropopause or inversion layer.

Gary, B. L.↗

System for indicating fuel-efficient aircraft altitude

A method and apparatus are provided for indicating the altitude at which an aircraft should fly so the W/d ratio (weight of the aircraft divided by the density of air) more closely approaches the optimum W/d for the aircraft. A passive microwave radiometer on the aircraft is directed at different angles with respect to the horizon to determine the air temperature, and therefore the density of the air, at different altitudes. The weight of the aircraft is known. The altitude of the aircraft is changed to fly the aircraft at an altitude at which is W/d ratio more closely approaches the optimum W/d ratio for that aircraft.

Gary, B. L.↗

Improved Position Sensor for Feedback Control of Levitation

An improved optoelectronic apparatus has been developed to provide the position feedback needed for controlling the levitation subsystem of a containerless-processing system. As explained, the advantage of this apparatus over prior optoelectronic apparatuses that have served this purpose stems from the use of an incandescent lamp, instead of a laser, to illuminate the levitated object. In containerless processing, a small object to be processed is levitated (e.g., by use of a microwave, low-frequency electromagnetic, electrostatic, or acoustic field) so that it is not in contact with the wall of the processing chamber or with any other solid object during processing. In the case of electrostatic or low-frequency electromagnetic levitation, real-time measurement of the displacement of the levitated object from its nominal levitation position along the vertical axis (and, in some cases, along one or two horizontal axes) is needed for feedback control of the levitating field.

Hyers, Robert↗

NASA Tech Briefs, November 2012

The topics include: Visual System for Browsing, Analysis, and Retrieval of Data (ViSBARD); Time-Domain Terahertz Computed Axial Tomography NDE System; Adaptive Sampling of Time Series During Remote Exploration; A Tracking Sun Photometer Without Moving Parts; Surface Temperature Data Analysis; Modular, Autonomous Command and Data Handling Software with Built-In Simulation and Test; In-Situ Wire Damage Detection System; Amplifier Module for 260-GHz Band Using Quartz Waveguide Transitions; Wideband Agile Digital Microwave Radiometer; Buckyball Nucleation of HiPco Tubes; FACT, Mega-ROSA, SOLAROSA; An Integrated, Layered-Spinel Composite Cathode for Energy Storage Applications; Engineered Multifunctional Surfaces for Fluid Handling; Polyolefin-Based Aerogels; Adjusting Permittivity by Blending Varying Ratios of SWNTs; Gravity-Assist Mechanical Simulator for Outreach; Concept for Hydrogen-Impregnated Nanofiber/Photovoltaic Cargo Stowage System; DROP: Durable Reconnaissance and Observation Platform; Developing Physiologic Models for Emergency Medical Procedures Under Microgravity; Spectroscopic Chemical Analysis Methods and Apparatus; Low Average Sidelobe Slot Array Antennas for Radiometer Applications; Motion-Corrected 3D Sonic Anemometer for Tethersondes and Other Moving Platforms; Water Treatment Systems for Long Spaceflights; Microchip Non-Aqueous Capillary Electrophoresis (MicronNACE) Method to Analyze Long-Chain Primary Amines; Low-Cost Phased Array Antenna for Sounding Rockets, Missiles, and Expendable Launch Vehicles; Mars Science Laboratory Engineering Cameras; Seismic Imager Space Telescope; Estimating Sea Surface Salinity and Wind Using Combined Passive and Active L-Band Microwave Observations; A Posteriori Study of a DNS Database Describing Super critical Binary-Species Mixing; Scalable SCPPM Decoder; QuakeSim 2.0; HURON (HUman and Robotic Optimization Network) Multi-Agent Temporal Activity Planner/Scheduler; MPST Software: MoonKommand

Source record↗

Geodetic distance measuring apparatus

A geodetic distance measuring apparatus which compensates for the refractive index of the atmosphere is discussed. A mode locked laser system with a laser device and its peripheral components is utilized to derive two mutually phase locked optical wavelength signals and one phase locked microwave CW signal which respectively traverse the same distance measurement path. The optical signals are comprised of pulse type signals. Phase comparison of the two optical wavelength pulse signals is used to provide the dry air density while phase comparison of one of the optical wavelength pulse signals and the microwave CW signal issued to provide wet or water vapor density of the air. The distance to be measured corrected for the atmospheric dry air and water vapor densities in the measurement path is computed from these measurements. A time interval unit is included for measuring transit time of individual optical pulses for resolving the phase ambiguity needed with the phase measurements to give the true target distance.

Abshire, J. B.↗

NASA Tech Briefs, February 2005

Topics discussed include: Instrumentation for Sensitive Gas Measurements; Apparatus for Testing Flat Specimens of Thermal Insulation; Quadrupole Ion Mass Spectrometer for Masses of 2 to 50 Da; Miniature Laser Doppler Velocimeter for Measuring Wall Shear; Coherent Laser Instrument Would Measure Range and Velocity; Printed Microinductors for Flexible Substrates; Digital Receiver for Microwave Radiometry; Printed Antennas Made Reconfigurable by Use of MEMS Switches; Traffic-Light-Preemption Vehicle-Transponder Software Module; Intersection-Controller Software Module; Central-Monitor Software Module; Estimating Effects of Multipath Propagation on GPS Signals; Parallel Adaptive Mesh Refinement Library; Predicting Noise From Aircraft Turbine-Engine Combustors; Generating Animated Displays of Spacecraft Orbits; Diagnosis and Prognosis of Weapon Systems; Training Software in Artificial-Intelligence Computing Techniques; APGEN Version 5.0; Single-Command Approach and Instrument Placement by a Robot on a Target; Three-Dimensional Audio Client Library; Isogrid Membranes for Precise, Singly Curved Reflectors; Nickel-Tin Electrode Materials for Nonaqueous Li-Ion Cells; Photocatalytic Coats in Glass Drinking-Water Bottles; Fast Laser Shutters With Low Vibratory Disturbances; Series-Connected Buck Boost Regulators; Space Physics Data Facility Web Services; Split-Resonator, Integrated-Post Vibratory Microgyroscope; Blended Buffet-Load-Alleviation System for Fighter Airplane; Gifford-McMahon/Joule-Thomson Refrigerator Cools to 2.5 K; High-Temperature, High-Load-Capacity Radial Magnetic Bearing; Fabrication of Spherical Reflectors in Outer Space; Automated Rapid Prototyping of 3D Ceramic Parts; Tissue Engineering Using Transfected Growth-Factor Genes; Automation of Vapor-Diffusion Growth of Protein Crystals; Atom Skimmers and Atom Lasers Utilizing Them; Gears Based on Carbon Nanotubes; Patched Off-Axis Bending/Twisting Actuators for Thin Mirrors; and Improving Control in a Joule-Thomson Refrigerator.

Source record↗

Particle Velocity Measuring System

Method and apparatus are provided for determining the velocity of individual food particles within a liquid/solid food mixture that is cooked by an aseptic cooking method whereby the food mixture is heated as it flows through a flowline. At least one upstream and at least one downstream microwave transducer are provided to determine the minimum possible travel time of the fastest food particle through the flowline. In one embodiment, the upstream detector is not required. In another embodiment, a plurality of small dipole antenna markers are secured to a plurality of food particles to provide a plurality of signals as the markers pass the upstream and downstream transducers. The dipole antenna markers may also include a non-linear element to reradiate a harmonic frequency of a transmitter frequency. Upstream and downstream transducers include dipole antennas that are matched to the impedance of the food slurry and a signal transmission cable by various impedance matching means including unbalanced feed to the antennas.

Arndt, G. Dickey↗

RF beam center location method and apparatus for power transmission system

The receiving element in wireless power transmission systems intercepts the greatest possible portion of the transmitted energy beam. Summing the output energy of all receivers in a planar array makes it possible to determine the location of the center of energy of the incident beam on a receiving array of antenna elements so that the incident beam is in the microwave region.

Dickinson, R. M.↗

Method for Selective Thermal Ablation

A method, simulation, and apparatus are provided that are highly suitable for treatment of benign prostatic hyperplasia (BPH). A catheter is disclosed that includes a small diameter disk loaded monopole antenna surrounded by fusion material having a high heat of fusion and a melting point preferably at or near body temperature. Microwaves from the antenna heat prostatic tissue to promote necrosing of the prostatic tissue that relieves the pressure of the prostatic tissue against the urethra as the body reabsorbs the necrosed or dead tissue. The fusion material keeps the urethra cool by means of the heat of fusion of the fusion material. This prevents damage to the urethra while the prostatic tissue is necrosed. A computer simulation is provided that can be used to predict the resulting temperature profile produced in the prostatic tissue. By changing the various control features of the catheter and method of applying microwave energy a temperature profile can be predicted and produced that is similar to the temperature profile desired for the particular patient.

Arndt, G. Dickey↗