Search NASA⌕ Search

SEARCH · Search NASA

Results for “MIRROR RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Cost/performance of solar reflective surfaces for parabolic dish concentrators

Materials for highly reflective surfaces for use in parabolic dish solar concentrators are discussed. Some important factors concerning performance of the mirrors are summarized, and typical costs are treated briefly. Capital investment cost/performance ratios for various materials are computed specifically for the double curvature parabolic concentrators using a mathematical model. The results are given in terms of initial investment cost for reflective surfaces per thermal kilowatt delivered to the receiver cavity for various operating temperatures from 400 to 1400 C. Although second surface glass mirrors are emphasized, first surface, chemically brightened and anodized aluminum surfaces as well as second surface, metallized polymeric films are treated. Conventional glass mirrors have the lowest cost/performance ratios, followed closely by aluminum reflectors. Ranges in the data due to uncertainties in cost and mirror reflectance factors are given.

Bouquet, F.↗

Off-axis phonon and photon propagation in porous silicon superlattices studied by Brillouin spectroscopy and optical reflectance

Brillouin light scattering experiments and optical reflectance measurements were performed on a pair of porous silicon-based optical Bragg mirrors which had constituent layer porosity ratios close to unity. For off-axis propagation, the phononic and photonic band structures of the samples were modeled as a series of intersecting linear dispersion curves. Zone-folding was observed for the longitudinal bulk acoustic phonon and the frequency of the probed zone-folded longitudinal phonon was shown to be dependent on the propagation direction as well as the folding order of the mode branch. There was no conclusive evidence of coupling between the transverse and the folded longitudinal modes. Two additional observed Brillouin peaks were attributed to the Rayleigh surface mode and a possible pseudo-surface mode. Both of these modes were dispersive, with the velocity increasing as the wavevector decreased.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-sensitivity three-mode optomechanical transducer

Three-mode optomechanical interactions have been predicted to allow the creation of very high sensitivity transducers in which very strong optical self-cooling and strong optomechanical quantum entanglement are predicted. Strong coupling is achieved by engineering a transducer in which both the pump laser and a single signal sideband frequency are resonantly enhanced. Here we demonstrate that very high sensitivity can be achieved in a very simple system consisting of a Fabry-Perot cavity with CO{sub 2} laser thermal tuning. We demonstrate a displacement sensitivity of {approx}1x10{sup -17} m/{radical}(Hz), which is sufficient to observe a thermally excited acoustic mode in a 5.6 kg sapphire mirror with a signal-to-noise ratio of more than 20 dB. It is shown that a measurement sensitivity of {approx}2x10{sup -20} m/{radical}(Hz) limited by the quantum shot noise is achievable with optimization of the cavity parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Segmented X-Ray Optics for Future Space Telescopes

Lightweight and high resolution mirrors are needed for future space-based X-ray telescopes to achieve advances in high-energy astrophysics. The slumped glass mirror technology in development at NASA GSFC aims to build X-ray mirror modules with an area to mass ratio of approx.17 sq cm/kg at 1 keV and a resolution of 10 arc-sec Half Power Diameter (HPD) or better at an affordable cost. As the technology nears the performance requirements, additional engineering effort is needed to ensure the modules are compatible with space-flight. This paper describes Flight Mirror Assembly (FMA) designs for several X-ray astrophysics missions studied by NASA and defines generic driving requirements and subsequent verification tests necessary to advance technology readiness for mission implementation. The requirement to perform X-ray testing in a horizontal beam, based on the orientation of existing facilities, is particularly burdensome on the mirror technology, necessitating mechanical over-constraint of the mirror segments and stiffening of the modules in order to prevent self-weight deformation errors from dominating the measured performance. This requirement, in turn, drives the mass and complexity of the system while limiting the testable angular resolution. Design options for a vertical X-ray test facility alleviating these issues are explored. An alternate mirror and module design using kinematic constraint of the mirror segments, enabled by a vertical test facility, is proposed. The kinematic mounting concept has significant advantages including potential for higher angular resolution, simplified mirror integration, and relaxed thermal requirements. However, it presents new challenges including low vibration modes and imperfections in kinematic constraint. Implementation concepts overcoming these challenges are described along with preliminary test and analysis results demonstrating the feasibility of kinematically mounting slumped glass mirror segments.

McClelland, Ryan S.↗

Identification of low-frequency fluctuations in the terrestrial magnetosheath

On the basis of magnetohydrodynamic (MHD) theory we develop a scheme for distinguishing among the four low-frequency modes which may propagate in a high-beta anisotropic plasma such as the magnetosheath: the fast and slow magnetosonic, the Alfven, and mirror modes. We use four parameters: the ratio of transverse to compressional powers in the magnetic field, the ratio of the wave powers in the thermal pressure and in the magnetic field, the ratio of the perturbations in the thermal and magnetic pressures, and the ratio of the wave powers in the velocity and in the magnetic field. In the test case of an Active Magnetospheric Particle Tracer Explorers/Ion Release Module (AMPTE/IRM) magnetosheath pass near the Sun-Earth line downstream of a quasi-perpendicular shock, the four modes can be clearly distinguished both spatially and spectrally. Near the bow shock, the waves are Alfvenic in a large frequency range, 1 to 100 mHz. In the middle and inner magnetosheath, the waves below 10 mHz are Alfvenic. The fast mode waves occur in the higher-frequency end of the enhanced spectrum, 80 mHz for the middle magnetosheath and 55 mHz for the inner sheath. The wave enhancement in the intermediate frequencies is slow modes in the inner sheath and mirror modes in the middle sheath. This confirms the earlier report of the existence of the slow mode waves near the magnetopause. These slow waves provide evidence that the magnetopause is an active source of the waves in the sheath. We also show that the measured frequency of a wave is close to an invariant if the magnetosheath flow is in a steady state. Therefore changes in the frequencies of enhanced waves indicate emergence, or damping, or mode conversion of the waves.

Song, P.↗

Scaling laws for light weight optics, studies of light weight mirrors mounting and dynamic mirror stress, and light weight mirror and mount designs

Scaling laws for light-weight optical systems are examined. A cubic relationship between mirror diameter and weight has been suggested and used by many designers of optical systems as the best description for all light-weight mirrors. A survey of existing light-weight systems in the open literature was made to clarify this issue. Fifty existing optical systems were surveyed with all varieties of light-weight mirrors including glass and beryllium structured mirrors, contoured mirrors, and very thin solid mirrors. These mirrors were then categorized and weight to diameter ratio was plotted to find a best curve for each case. A best fitting curve program tests nineteen different equations and ranks a goodness-to-fit for each of these equations. The resulting relationship found for each light-weight mirror category helps to quantify light-weight optical systems and methods of fabrication and provides comparisons between mirror types.

Vukobratovich, Daniel↗

Scaling laws for light-weight optics

Scaling laws for light-weight optical systems are examined. A cubic relationship between mirror diameter and weight has been suggested and used by many designers of optical systems as the best description for all light-weight mirrors. A survey of existing light-weight systems in the open literature has been made to clarify this issue. Fifty existing optical systems were surveyed with all varieties of light-weight mirrors including glass and beryllium structured mirrors, contoured mirrors, and very thin solid mirrors. These mirrors were then categorized and weight to diameter ratio was plotted to find a best fit curve for each case. A best fitting curve program tests nineteen different equations and ranks a 'goodness of fit' for each of these equations. The resulting relationship found for each light-weight mirror category helps to quantify light-weight optical systems and methods of fabrication and provides comparisons between mirror types.

Valente, Tina M.↗

MEASUREMENT OF Fn 2 /Fp 2 FROM DEEP INELASTIC ELECTRON SCATTERING OFF A=3 MIRROR NUCLEI AT JEFFERSON LAB

This research is part of the Je?erson Lab MARATHON experiment (MeAsurement of the Fn 2 /Fp 2 , d/u RAtios and A = 3 EMC E?ect in Deep Inelastic Electron Scattering Off the Tritium and Helium MirrOr Nuclei). MARATHON is an experiment on electron deep inelastic scattering off the 3H, 3He mirror nuclei. It has extracted, from the measured deep inelastic scattering cross section ratio o? 3H and 3He, the ratio of the neutron to proton inelastic structure functions Fn 2 /Fp 2 . The extraction has taken advantage of the isospin symmetry of the A = 3 mirror nuclei within a novel technique, which avoids the theoretical uncertainties that are present in the SLAC experiments of the 1970s, which used hydrogen and deuterium targets. The experiment was performed using the upgraded 11 GeV beam of the Jefferson Lab electron accelerator, the Hall A Experimental Facility, and a newly designed cryogenic, high-pressure gas target system containing 3H and 3He cells. Electrons scattered o? the gas targets were detected in the two superconducting, high-resolution magnetic spectrometers of Hall A. The cross section data cover the four-momentum transfer squared range 2.0 < Q2 < 14.0 (GeV/c)2, and the Bjorken x scaling variable range 0.19 < x < 0.83. The experiment also measured, for calibration purposes, electron deep inelastic scattering off hydrogen and deuterium at selected kinematics.

Su, Tong↗

Concentrator designs for space photovoltaic arrays

The unique set of operating constraints determining key concentrating solar array design characteristics for low earth orbital, geosynchronous and interplanetary missions are considered. Minimum cost is crucial at low earth orbits, performance and design life are needed in geosynchronous orbit, and structural pointing accuracy and radiation resistance are essential in interplanetary designs. The impact of such emerging technologies as ultrathin cells, gallium arsenide cells and cold mirrors is discussed. Power-to-mass ratios as high as 200 W per kilogram at a distance of 1 astronomical unit from the sun are possible, using concentrators in conjunction with gallium arsenide arrays.

Rockey, D. E.↗

Substrate effects on the epitaxial growth of ZnGeP2 thin films by open tube organometallic chemical vapor deposition

Epitaxial ZnGeP2-Ge films have been grown on (111)GaP substrates using MOCVD. The films grown with dimethylzinc to germane flow rate ratio R greater than 10 show mirror-smooth surface morphology. Films grown with R less than 10 show a high density of twinning, including both double position and growth twins. Compared to films grown on (001) GaP substrates, the layers on (111) GaP generally show a higher density of microstructural defects. TEM electron diffraction patterns show that the films grown on (111) GaP substrates are more disordered than films grown on (001) GaP under comparable conditions. The growth rate on (111) GaP substrates is about 2.5 times slower than that on (001) GaP, and films grown on Si substrates show extensive twinning formation. Both TEM and SEM examinations indicate that smooth epitaxial overgrowth may be easier on (111) Si substrates than on (001) Si.

Xing, G. C.↗

SOFIA Optical Design for the Aft Configuration

The Stratospheric Observatory for Infrared Astronomy (SOFIA) is a planned NASA facility consisting of an infrared telescope of 2.5 meter system aperture flying in a modified Boeing 747. It will have an image diameter of 1.5 arc seconds, an operating wavelength range from visible through 1 millimeter, an 8 arc minute field of view, and a chopping secondary. the configuration is a Cassegrian with a diagonal tertiary to direct the beam to a Nasmyth focus. The new choice of a location aft of the wings allows the primary mirror to have about an f/1.4 focal ratio, which is preferable to f/1.1 previously planned for the forward location.

Davis, Paul K.↗

Wide acceptance angle, high concentration ratio, optical collector

A cassegrain optical system provides improved collection of off-axis light yet is still characterized by a high concentration ratio. The optical system includes a primary mirror for collecting incoming light and reflecting the light to a secondary mirror which, in turn, reflects the light to a solar cell or other radiation collection device. The primary mirror reflects incoming on-axis light onto an annular section of the secondary mirror and results in the reflection of a substantial amount of incoming off-axis light onto the remainder of the secondary mirror. Thus light which would otherwise be lost to the system will be captured by the collector. Furthermore, the off-axis sections of the secondary mirror may be of a different geometrical shape than the on-axis annular section so as to optimize the amount of off-axis light collected.

Kruer, Mark A.↗

Degradation of Ta 2 O 5 / SiO 2 dielectric cavity mirrors in ultra-high vacuum

In order for optical cavities to enable strong light-matter interactions for quantum metrology, networking, and scalability in quantum computing systems, their mirrors must have minimal losses. However, high-finesse dielectric cavity mirrors can degrade in ultra-high vacuum (UHV), increasing the challenges of upgrading to cavity-coupled quantum systems. We observe the optical degradation of high-finesse dielectric optical cavity mirrors after high-temperature UHV bake in the form of a substantial increase in surface roughness. We provide an explanation of the degradation through atomic force microscopy (AFM), X-ray fluorescence (XRF), selective wet etching, and optical measurements. We find the degradation is explained by oxygen reduction in Ta 2 O 5 followed by growth of tantalum sub-oxide defects with height to width aspect ratios near ten. We discuss the dependence of mirror loss on surface roughness and finally give recommendations to avoid degradation to allow for quick adoption of cavity-coupled systems.

Optics↗

Microinstabilities in the Gasdynamic Mirror Propulsion System

The gasdynamic mirror has been proposed as a concept which could form the basis of a highly efficient fusion rocket engine. Gasdynamic mirrors differ from most other mirror type plasma confinement schemes in that they have much larger aspect ratios and operate at somewhat higher plasma densities. There are several types of instabilities which are known to plague mirror type confinement schemes. These instabilities fall into two general classes. One class of instability is the Magnetohydrodynamic or MHD instability which induces gross distortions in the plasma geometry. The other class of instability is the "loss cone" microinstability which leads to general plasma turbulence. The "loss cone" microinstability is caused by velocity space asymmetries resulting from the loss of plasma having constituent particle velocities within the angle of the magnetic mirror "loss cone." These instabilities generally manifest themselves in high temperature, moderately dense plasmas. The present study indicates that a GDM configured as a rocket engine might operate in a plasma regime where microinstabilities could potentially be significant.

Emrich, William↗

Microinstabilities in the Gasdynamic Mirror Propulsion System

The gasdynamic mirror has been proposed as a concept which could form the basis of a highly efficient fusion rocket engine. Gasdynamic mirrors differ from most other mirror type plasma confinement schemes in that they have much larger aspect ratios and operate at somewhat higher plasma densities. There are several types of instabilities which are known to plague mirror type confinement schemes. These instabilities fall into two general classes. One class of instability is the Magnetohdrodynamic or MHD instability which induces gross distortions in the plasma geometry. The other class of instability is the "loss cone" microinstability which leads to general plasma turbulence. The "loss cone" microinstability is caused by velocity space asymmetries resulting from the loss of plasma having constituent particle velocities within the angle of the magnetic mirror "loss cone." These instabilities generally manifest themselves in high temperature, moderately dense plasmas. The present study indicates that a GDM configured as a rocket engine might operate in a plasma regine where microinstabilities could potentially be significant.

Emrich, William↗

The Dynamics of a Field in a Cavity with a Slowly Oscillating Metal Mirror

We have examined analytically the behavior of an electromagnetic field in a cavity of one of two metal mirrors that is stationary, while the other mirror oscillates in the vicinity of its equilibrium position. The case in which the period of the mirror oscillations substantially exceeds the characteristic roundtrip time of the electromagnetic radiation in the cavity has been considered. To solve the problem, we have applied the method of two time scales. The method makes it possible to solve the problem by using the expansion with respect to a small parameter, for which the ratio of the cavity roundtrip time to the mirror-oscillation period is used. The solution to the problem in the zeroth-order approximation with respect to the small parameter has been obtained and examined. This solution has been shown to be correct up to the mirror-oscillation amplitude being on the order of the average cavity length. We have showed that this scheme can be used to gain and generate electromagnetic radiation. We have compared our results obtained for the oscillating mirror with the results of an exact solution of the problem when the mirror moves uniformly and rectilinearly. We have showed that, in these two cases, a change in the total field energy in the cavity is inversely proportional to the current value of the cavity length.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sunlight collection system with asymmetric catadioptric optics

The system captures and concentrates sunlight for transmission to interior spaces or to a PV system. A solar collector uses arrayed refractive lenses, opposing concave focusing mirrors, and a movable coupling sheet forming part of a lightguide. The lenses and mirrors have an asymmetric shape, such as having aspect ratios of 3:4 or 1:2, so as to have an asymmetric aperture to better receive light at the different ranges of angles of the sun's rays over the course of a year. The long axis of the apertures is generally oriented in an East-West. The movable sheet contains small angled mirrors, and the sheet is translated to position the angled mirrors at the focal points of the sunlight for maximum deflection of the sunlight to an output of the collection system. A position sensor provides feedback regarding the position of the angled mirrors relative to the focal points.

Kozodoy, Peter↗

The 3H-3He Charge Radii Difference

The upcoming E12-14-009 [1] experiment at Jefferson Lab will determine the ratio of the electric form factors for the A=3 mirror nuclei 3He and 3H. The measurement will use a 1.1 GeV electron beam, a special collimator plate to allow for simultaneous optics measurements, and the low-activity tritium target being prepared for Jefferson Lab. By observing the dependence of the form factor ratio as a function of Q2 over 0.05–0.09 GeV2, the dependence of the radii extraction on the shape of the form factors is minimized. As a result, we anticipate the uncertainty of the extracted charge radii difference to be 0.03 fm, a reduction of 70% from the current measurement. Using precise measurements of the 3He charge radius from isotopic shift or μHe measurements [2–4], we can deduce the absolute 3H charge radius. The results will provide a direct comparison to recent calculations of the charge radii.

Myers, Luke S.↗