Search NASA⌕ Search

SEARCH · Search NASA

Results for “MITIGATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Protection of extreme ultraviolet lithography masks. II. Showerhead flow mitigation of nanoscale particulate contamination [Protection of EUV lithography masks II: Showerhead flow mitigation of nanoscale particulate contamination]

An analysis is presented of a method to protect the reticle (mask) in an extreme ultraviolet (EUV) mask inspection tool using a showerhead plenum to provide a continuous flow of clean gas over the surface of a reticle. The reticle is suspended in an inverted fashion (face down) within a stage/holder that moves back and forth over the showerhead plenum as the reticle is inspected. It is essential that no particles of 10-nm diameter or larger be deposited on the reticle during inspection. Particles can originate from multiple sources in the system, and mask protection from each source is explicitly analyzed. The showerhead plate has an internal plenum with a solid conical wall isolating the aperture. The upper and lower surfaces of the plate are thin flat sheets of porous-metal material. These porous sheets form the top and bottom showerheads that supply the region between the showerhead plate and the reticle and the region between the conical aperture and the Optics Zone box with continuous flows of clean gas. The model studies show that the top showerhead provides robust reticle protection from particles of 10-nm diameter or larger originating from the Reticle Zone and from plenum surfaces contaminated by exposure to the Reticle Zone. Protection is achieved with negligible effect on EUV transmission. Furthermore, the bottom showerhead efficiently protects the reticle from nanoscale particles originating from the Optics Zone.

36 MATERIALS SCIENCE↗

Perennialization and Cover Cropping Mitigate Soil Carbon Loss from Residue Harvesting

While the US Midwest is expected to serve as a primary feedstock source for cellulosic biofuel production, the impacts of residue harvesting on soil organic carbon (SOC) may greatly limit sustainable production capacity. However, viable feedstock production could be realized through adoption of management practices and cropping systems that offset residue‐harvest‐induced SOC losses. Sequestration of SOC can be enhanced by increasing the duration of crop soil cover through cover or double cropping or cultivation of dedicated perennials. However, assessing the efficacy of such options across sites and over long periods is experimentally challenging. Hence, we use the Environmental Productivity Integrated Climate (EPIC) model to provide such an assessment. Model‐data integration was used to calibrate and evaluate model suitability, which exhibited reasonable effectiveness through R 2 of 0.97 and 0.63 for SOC stock and yield, respectively. Long‐term simulations indicate considerable capacity for offsetting SOC loss. Incorporating rye ( Secale cereal L.) into continuous corn ( Zea mays L.) and corn–soybean [ Glycine max (L.) Merr.] systems offset the SOC losses induced by harvesting 21.2 and 38.3% of available stover, respectively. Similarly, converting 20.4% of corn–soybean land to miscanthus ( Miscanthus × giganteus J.M. Greef & Deuter ex Hodkinson & Renvoize) or 27.5% of land to switchgrass ( Panicum virgatum L.) offset the SOC impacts of harvesting 60% of stover from the remaining corn–soybean lands. These responses indicate that adoption of such measures would sizably affect the life cycle consequences of residue‐derived biofuels and expand estimates of sustainable cellulosic feedstock production capacity from the US Midwest. Core Ideas EPIC suitably assessed SOC under annual, cover, double, and perennial crops. Perennial cultivation offset the SOC losses of considerable residue harvesting. Rye double crops offset sizable residue‐induced SOC losses. Adoption could greatly expand Midwestern sustainable biofuel production capacity.

Jones, Curtis D.↗

Demonstration of thermal control, microstructure control, defect mitigation and process parameter database generation for Ti-6Al-4V Direct Digital Manufacturing - Understanding defect mitigation and process parameter database generation for direct digital manufacturing

Researchers from Manufacturing Demonstration Facility (MDF) at Oak Ridge National Laboratory (ORNL) worked with Applied Optimization (AO) to understand and evaluate the propensity for defect formation in builds manufactured using DM3D-POM laser direct metal deposition. The main aim of this collaboration was to understand the character of powder jet behavior as a function of the nozzle parameters such as cover gas, carrier gas, and shaping gas. In order to evaluate the sensitivities of the parameters used in model, various experiments were performed with in-situ monitoring of the powder stream characteristics using a high speed camera. A wide variety of conditions while keeping the hopper motor rpm constant, including laser power and travel speed were explored. The cross sections of the deposits were characterized using optical microscopy.

47 OTHER INSTRUMENTATION↗

Composite Materials for Hazard Mitigation of Reactive Metal Hydrides.

In an attempt to mitigate the hazards associated with storing large quantities of reactive metal hydrides, polymer composite materials were synthesized and tested under simulated usage and accident conditions. The composites were made by polymerizing vinyl monomers using free-radical polymerization chemistry, in the presence of the metal hydride. Composites with vinyl-containing siloxane oligomers were also polymerized with and without added styrene and divinyl benzene. Hydrogen capacity measurements revealed that addition of the polymer to the metal hydride reduced the inherent hydrogen storage capacity of the material. The composites were found to be initially effective at reducing the amount of heat released during oxidation. However, upon cycling the composites, the mitigating behavior was lost. While the polymer composites we investigated have mitigating potential and are physically robust, they undergo a chemical change upon cycling that makes them subsequently ineffective at mitigating heat release upon oxidation of the metal hydride. Acknowledgements The authors would like to thank the following people who participated in this project: Ned Stetson (U.S. Department of Energy) for sponsorship and support of the project. Ken Stewart (Sandia) for building the flow-through calorimeter and cycling test stations. Isidro Ruvalcaba, Jr. (Sandia) for qualitative experiments on the interaction of sodium alanate with water. Terry Johnson (Sandia) for sharing his expertise and knowledge of metal hydrides, and sodium alanate in particular. Marcina Moreno (Sandia) for programmatic assistance. John Khalil (United Technologies Research Corp) for insight into the hazards of reactive metal hydrides and real-world accident scenario experiments. Summary In an attempt to mitigate and/or manage hazards associated with storing bulk quantities of reactive metal hydrides, polymer composite materials (a mixture of a mitigating polymer and a metal hydride) were synthesized and tested under simulated usage and accident conditions. Mitigating the hazards associated with reactive metal hydrides during an accident while finding a way to keep the original capability of the active material intact during normal use has been the focus of this work. These composites were made by polymerizing vinyl monomers using free-radical polymerization chemistry, in the presence of the metal hydride, in this case a prepared sodium alanate (chosen as a representative reactive metal hydride). It was found that the polymerization of styrene and divinyl benzene could be initiated using AIBN in toluene at 70°C. The resulting composite materials can be either hard or brittle solids depending on the cross-linking density. Thermal decomposition of these styrene-based composite materials is lower than neat polystyrene indicating that the chemical nature of the polymer is affected by the formation of the composite. The char-forming nature of cross-linked polystyrene is low and therefore, not an ideal polymer for hazard mitigation. To obtain composite materials containing a polymer with higher char-forming potential, siloxane-based monomers were investigated. Four vinyl-containing siloxane oligomers were polymerized with and without added styrene and divinyl benzene. Like the styrene materials, these composite materials exhibited thermal decomposition behavior significantly different than the neat polymers. Specifically, the thermal decomposition temperature was shifted approximately 100 °C lower than the neat polymer signifying a major chemical change to the polymer network. Thermal analysis of the cycled samples was performed on the siloxane-based composite materials. It was found that after 30 cycles the siloxane-containing polymer composite material has similar TGA/DSC-MS traces as the virgin composite material indicating that the polymer is physically intact upon cycling. Hydrogen capacity measurements revealed that addition of the polymer to the metal hydride in the form of a composite material reduced the inherent hydrogen storage capacity of the material. This reduction in capacity was observed to be independent of the amount of charge/discharge cycles except for the composites containing siloxane, which showed less of an impact on hydrogen storage capacity as it was cycled further. While the reason for this is not clear, it may be due to a chemically stabilizing effect of the siloxane on the metal hydride. Flow-through calorimetry was used to characterize the mitigating effectiveness of the different composites relative to the neat (no polymer) material. The composites were found to be initially effective at reducing the amount of heat released during oxidation, and the best performing material was the siloxane-containing composite which reduced the heat release to less than 50% of the value of the neat material. However, upon cycling the composites, all mitigating behavior was lost. The combined results of the flow-through calorimetry, hydrogen capacity, and thermogravimetric analysis tests lead to the proposed conclusion that while the polymer composites have mitigating potential and are physically robust under cycling, they undergo a chemical change upon cycling that makes them ineffective at mitigating heat release upon oxidation of the metal hydride.

36 MATERIALS SCIENCE↗

Hungry Horse Mitigation : Flathead Lake : Annual Progress Report 2007.

The Confederated Salish and Kootenai Tribes (CSKT) and Montana Fish Wildlife and Parks (MFWP) wrote the 'Fisheries Mitigation Plan for Losses Attributable to the Construction and Operation of Hungry Horse Dam' in March 1991 to define the fisheries losses, mitigation alternatives and recommendations to protect, mitigate and enhance resident fish and aquatic habitat affected by Hungry Horse Dam. On November 12, 1991, the Northwest Power Planning Council (NPPC) approved the mitigation plan with minor modifications, called for a detailed implementation plan, and amended measures 903(h)(1) through (7). A long-term mitigation plan was submitted in August 1992, was approved by the Council in 1993, and the first contract for this project was signed on November 11, 1993. The problem this project addresses is the loss of habitat, both in quality and quantity, in the Flathead Lake and River basin resulting from the construction and operation of Hungry Horse Dam. The purpose of the project is to both implement mitigation measures and monitor the biological responses to those measures including those implemented by Project Numbers 9101903 and 9101904. Goals and objectives of the 1994 Fish and Wildlife Program (Section 10.1) addressed by this project are the rebuilding to sustainable levels weak, but recoverable, native populations injured by the hydropower system. The project mitigates the blockage of spawning runs by Hungry Horse Dam by restoring and even creating spawning habitats within direct drainages to Flathead Lake. The project also addresses the altered habitat within Flathead Lake resulting from species shifts and consequent dominance of new species that restricts the potential success of mitigation measures. Specific goals of this project are to create and restore habitat and quantitatively monitor changes in fish populations to verify the efficacy of our mitigation measures. The project consists of three components: monitoring, restoration and research. Monitoring, for example, includes a spring gillnetting series conducted annually in Flathead Lake and builds on an existing data set initiated in 1981. Monitoring of the experimental kokanee reintroduction was a primary activity of this project between 1992 and 1997. Lake trout, whose high densities have precluded successful mitigation of losses of other species in Flathead Lake, have been monitored since 1996 to measure several biological parameters. Results of this work have utility in determining the population status of this key predator in Flathead Lake. The project has also defined the baseline condition of the Flathead Lake fishery in 1992-1993 and has conducted annual lakewide surveys since 1998. The restoration component of the project has addressed several stream channel, riparian, and fish passage problems, and suppression of non-native fish. The research component of the project began in FY 2000 and measured trophic linkages between M. relicta and other species to assist in predicting the results of our efforts to suppress lake trout. Only Work Element A in the Statement of Work is funded entirely by Hungry Horse Mitigation funds. Additional funds are drawn from other sources to assist in completion of all remaining Work Elements.

13 HYDRO ENERGY↗

Hungry Horse Mitigation : Flathead Lake : Annual Progress Report 2008.

The Confederated Salish and Kootenai Tribes (CSKT) and Montana Fish Wildlife and Parks (MFWP) wrote the 'Fisheries Mitigation Plan for Losses Attributable to the Construction and Operation of Hungry Horse Dam' in March 1991 to define the fisheries losses, mitigation alternatives and recommendations to protect, mitigate and enhance resident fish and aquatic habitat affected by Hungry Horse Dam. On November 12, 1991, the Northwest Power Planning Council (NPPC) approved the mitigation plan with minor modifications, called for a detailed implementation plan, and amended measures 903(h)(1) through (7). A long-term mitigation plan was submitted in August 1992, was approved by the Council in 1993, and the first contract for this project was signed on November 11, 1993. The problem this project addresses is the loss of habitat, both in quality and quantity, in the Flathead Lake and River basin resulting from the construction and operation of Hungry Horse Dam. The purpose of the project is to both implement mitigation measures and monitor the biological responses to those measures including those implemented by Project Numbers 9101903 and 9101904. Goals and objectives of the 1994 Fish and Wildlife Program (Section 10.1) addressed by this project are the rebuilding to sustainable levels weak, but recoverable, native populations injured by the hydropower system. The project mitigates the blockage of spawning runs by Hungry Horse Dam by restoring and even creating spawning habitats within direct drainages to Flathead Lake. The project also addresses the altered habitat within Flathead Lake resulting from species shifts and consequent dominance of new species that restricts the potential success of mitigation measures. Specific goals of this project are to create and restore habitat and quantitatively monitor changes in fish populations to verify the efficacy of our mitigation measures. The project consists of three components: monitoring, restoration and research. Monitoring, for example, includes a spring gillnetting series conducted annually in Flathead Lake and builds on an existing data set initiated in 1981. Monitoring of the experimental kokanee reintroduction was a primary activity of this project between 1992 and 1997. Lake trout, whose high densities have precluded successful mitigation of losses of other species in Flathead Lake, have been monitored since 1996 to measure several biological parameters. Results of this work have utility in determining the population status of this key predator in Flathead Lake. The project has also defined the baseline condition of the Flathead Lake fishery in 1992-1993 and has conducted annual lakewide surveys since 1998. The restoration component of the project has addressed several stream channel, riparian, and fish passage problems, and suppression of non-native fish. The research component of the project began in FY 2000 and measured trophic linkages between M. relicta and other species to assist in predicting the results of our efforts to suppress lake trout. Only Work Element A in the Statement of Work is funded entirely by Hungry Horse Mitigation funds. Additional funds are drawn from other sources to assist in completion of all remaining Work Elements.

13 HYDRO ENERGY↗

Wetland Mitigation Monitoring at the Fernald Preserve - 13200

The U.S. Department of Energy is responsible for 7.2 hectares (17.8 acres) of mitigation wetland at the Fernald Preserve, Ohio. Remedial activities affected the wetlands, and mitigation plans were incorporated into site-wide ecological restoration planning. In 2008, the Fernald Natural Resource Trustees developed a comprehensive wetland mitigation monitoring approach to evaluate whether compensatory mitigation requirements have been met. The Fernald Preserve Wetland Mitigation Monitoring Plan provided a guideline for wetland evaluations. The Ohio Environmental Protection Agency (Ohio EPA) wetland mitigation monitoring protocols were adopted as the means for compensatory wetland evaluation. Design, hydrologic regime, vegetation, wildlife, and biogeochemistry were evaluated from 2009 to 2011. Evaluations showed mixed results when compared to the Ohio EPA performance standards. Results of vegetation monitoring varied, with the best results occurring in wetlands adjacent to forested areas. Amphibians, particularly ambystomatid salamanders, were observed in two areas adjacent to forested areas. Not all wetlands met vegetation performance standards and amphibian biodiversity metrics. However, Fernald mitigation wetlands showed substantially higher ratings compared to other mitigated wetlands in Ohio. Also, soil sampling results remain consistent with other Ohio mitigated wetlands. The performance standards are not intended to be 'pass/fail' criteria; rather, they are reference points for use in making decisions regarding future monitoring and maintenance. The Trustees approved the Fernald Preserve Wetland Mitigation Monitoring Report with the provision that long-term monitoring of the wetlands continues at the Fernald Preserve. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

THE USE OF DI WATER TO MITIGATE DUSTING FOR ADDITION OF DWPF FRIT TO THE SLURRY MIX EVAPORATOR

The Defense Waste Processing Facility (DPWF) presently is in the process to determine means to reduce water utilization in the Slurry Mix Evaporator (SME) process, thus reducing effluent and processing times. The frit slurry addition system mixes the dry frit with water, yielding approximately a 50 weight percent slurry containing frit and the other fraction water. This slurry is discharged into the SME and excess water is removed via boiling. To reduce this water load to the SME, DWPF has proposed using a pneumatic system in conveying the frit to the SME, in essence a dry delivery system. The problem associated with utilizing a dry delivery system with the existing frit is the generation of dust when discharged into the SME. The use of water has been shown to be effective in the mining industry as well in the DOE complex to mitigate dusting. The method employed by SRNL to determine the quantity of water to mitigate dusting in dry powders was effective, between a lab and bench scale tests. In those tests, it was shown that as high as five weight percent (wt%) of water addition was required to mitigate dust from batches of glass forming minerals used by the Waste Treatment Plant at Hanford, Washington. The same method used to determine the quantity of water to mitigate dusting was used in this task to determine the quantity of water to mitigate this dusting using as-received frit. The ability for water to mitigate dusting is due to its adhesive properties as shown in Figure 1-1. Wetting the frit particles allows for the smaller frit particles (including dust) to adhere to the larger frit particles or to agglomerate into large particles. Fluids other than water can also be used, but their adhesive properties are different than water and the quantity required to mitigate dusting is different, as was observed in reference 1. Excessive water, a few weight percentages greater than that required to mitigate dusting can cause the resulting material not to flow. The primary objective of this task is to perform bench scale testing on various frits that have been used at DWPF or in test programs at SRNL to determine the quantity of de-ionized (DI) water required to mitigate dusting per mass basis of frit. The quantity of DI water required was determined visually by observing the effluent port of the mixer, and DI water addition was made to the point where no visible dust was observed leaving the effluent port. A total of eight different frits were selected for testing. Secondary objectives in this task include the following: (1) Video taping of the de-dusting procedure, (2) Particle size distribution analyses of the dry and wetted frits at the weight fraction of water required for de-dusting, (3) Plate flow tests to determine angle of flow and quantity of material remaining on plate at 90 degrees, (4) Microscopy of dry and wetted frit, and (5) Effect of excess water for selected frits on plate flow. The above analyses were performed within one hour of water addition, to minimize the effect of evaporative water losses. To better understand the size of dust particles, perform settling tests on selected frits and capture the fines. Analyze the fines for particle size distribution. Finally, it is expected that the surface area of frit is an important parameter in the quantity of water required for dust mitigation. An analysis of particle size distribution (PSD) data of as-received frit analyzed by SRNL over the past two to three years will be performed to determine the variation in the distribution of as-received frit. The following objectives were stated in the Technical Task Request4 as objectives that given adequate time would provide insight in helping DWPF in assessing equipment or processes for de-dusting and processing of dry frit. Due to time constraints, commercial methods for dedusting are provided. These results are detailed in section 3.7. Obtain design information from Hanford with respective to equipment used for dedusting. Suggestions on enhanced design features, such as flush water, pipe air purges, humidified compressed air, options for agitation, and other base (SRNL) knowledge.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Demonstration of Wide Area Radiological Decontamination and Mitigation Technologies for Building Structures and Vehicles - 16508

Researchers at the U.S. Environmental Protection Agency in collaboration with the Department of Homeland Security conducted the 'Wide-Area Urban Radiological Contaminant, Mitigation, and Clean-Up Technology Demonstration' in Columbus, Ohio on June 22-25, 2015. EPA's National Homeland Security Research Center (NHSRC) demonstrated five wide-area radiological decontamination technologies (including strippable coatings, gels, and chemical foam technologies) on an urban building. Decontamination technologies were applied to remove the contaminants from the building's surfaces by physical, chemical, or other methods, which in practice could reduce radiation exposure level. In addition, NHSRC teamed with the Department of Homeland Security (DHS) to demonstrate several radiological contaminant mitigation technologies including building and vehicle wash technologies, as well as several approaches to contain wash water and radioactive particles. 'Radiological contaminant mitigation' technologies are measures taken to reduce adverse impacts of radiological contamination on people and the environment, and facilitate such purposes as restoration of first responder services and critical infrastructure. Radiological contaminant mitigation technologies are designed for containing and removing radiological contamination on the surface in the first hours or days following a radiological event (early phase response). Such technologies include 'radiological particle containment', which is design to prevent the spread of particles which might result from vehicle or foot traffic. Radiological particle containment technologies are applicable for early phase response to contain the radionuclides and to reduce radiation dose to responders and the public. Mitigation also includes 'gross decontamination' technologies, which perform a type of decontamination that is conducted with the goal of reducing contamination levels. This reduction may not meet final cleanup levels, but may be useful to mitigate some public hazard or contain contamination. The purpose of the demonstrations was to educate potential end-users and stakeholders of this technology about a 'Toolbox of Options' for radiological decontamination, as well as radiological contaminant mitigation. Both demonstrations were conducted using a 75-year old brick building and the surrounding area (including parking lots) in Columbus, OH. No radioactive contaminants were applied during either demonstration, as the objective was to duplicate and implement realistic operational conditions for these technologies. Surrogate contaminants such as particle tracers were used in several demonstrations. The decontamination technologies were used in a scaled-up setting with application to the building. Contaminant mitigation technologies were demonstrated on the building as well as on vehicles. Example technology application techniques/accessories included an articulating boom lift, repelling boatswain chair, stand-alone surface material structures, high-volume foam applicators, fire truck foam applicator, a vehicle wash tent for vehicles, particle tracers to simulate radiological contaminants, and high- and low-technology liquid containment approaches. Results and stakeholder observations from the demonstration are now publically in a report entitled 'Technical Report for the Demonstration of Radiological Decontamination and Mitigation Technologies for Building Structures and Vehicles' available at http://www.epa.gov/hsresearch Example information that was obtained included decontamination rate, contaminant mitigation and containment capacity, user friendliness of each technology, the required utilities (electric, water, etc.) for each technology, skill of worker required, and the cost. The condition (color, texture, integrity, etc.) of each building material present on the structure along with all structural components such as gutters, windows, doors, etc. were carefully examined and documented. All demonstrations were open to individuals, organizations, and local, state, federal, tribal, and international governments who may be involved with implementing or planning radiological incident response. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Limits to forests-based mitigation in integrated assessment modelling: global potentials and impacts under constraining factors

Forests-based measures such as afforestation/reforestation (A/R) and reducing deforestation (RDF) are considered promising options to mitigate climate change, yet their mitigation potentials are limited by economic and biophysical factors that are largely uncertain. The range of mitigation potential estimates from integrated assessment models raises concerns about the capacity of land systems to provide realistic, cost-effective and permanent land-based mitigation. We use the Global Change Analysis Model to quantify the economic mitigation potential of forests-based measures by simulating a climate policy including a tax on greenhouse gas emissions from agriculture, forestry, and other land uses. In addition, we assess how constraining unused arable land (UAL) availability, forestland expansion rates, and global bioenergy demand may influence the forests-based mitigation potential by simulating scenarios with alternative combinations of constraints. Results show that the average forests-based mitigation potential in 2020–2050 increases from 738 MtCO 2 .yr -1 through a forestland increase of 86 Mha in the fully constrained scenario to 1394 MtCO 2 .yr -1 through a forestland increase of 146 Mha when all constraints are relaxed. Regional potentials in terms of A/R and RDF differ strongly between scenarios: unconstrained forest expansion rates mostly increase A/R potentials in northern regions (e.g., +120 MtCO 2 .yr -1 in North America); while unconstrained UAL conversion and low bioenergy demand mostly increase RDF potentials in tropical regions (e.g., +76 and +68 MtCO 2 .yr -1 in Southeast Asia, respectively). This study shows that forests-based mitigation is limited by many factors that constrain the rates of land use change across regions. These factors, often overlooked in modelling exercises, should be carefully addressed for understanding the role of forests in global climate mitigation and defining pledges towards the Paris Agreement.

54 ENVIRONMENTAL SCIENCES↗

Predicting environmental mitigation requirements for hydropower projects through the integration of biophysical and socio-political geographies

Uncertainty about environmental mitigation needs at existing and proposed hydropower projects makes it difficult for stakeholders to minimize environmental impacts. Hydropower developers and operators desire tools to better anticipate mitigation requirements, while natural resource managers and regulators need tools to evaluate different mitigation scenarios and order effective mitigation. Here we sought to examine the feasibility of using a suite of multidisciplinary explanatory variables within a spatially explicit modeling framework to fit predictive models for future environmental mitigation requirements at hydropower projects across the conterminous U.S. Using a database comprised of mitigation requirements from more than 300 hydropower project licenses, we were able to successfully fit models for nearly 50 types of environmental mitigation and to apply the predictive models to a set of more than 500 non-powered dams identified as having hydropower potential. The results demonstrate that mitigation requirements have been a result of a range of factors, from biological and hydrological to political and cultural. Furthermore, project developers can use these models to inform cost projections and design considerations, while regulators can use the models to more quickly identify likely environmental issues and potential solutions, hopefully resulting in more timely and more effective decisions on environmental mitigation.

13 HYDRO ENERGY↗