Search NASA⌕ Search

SEARCH · Search NASA

Results for “MODEL VALIDATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

NWEI Azura RTI 1/20th Model Validation Wave Tank Test Data

Data from the 1/20th wave tank test of the RTI model. NWEI has licensed intellectual property from RTI, and modified the PTO and retested the 1/20th RTI model that was tested as part of the Wave Energy Prize. The goal of the test was to validate NWEI's simulation models of the model. The test occurred at the University of Maine in Orono.

16 TIDAL AND WAVE POWER↗

Chemical kinetics parameters and model validation for the gasification of PCEA nuclear graphite

A series of gasification experiments, using two right cylinder specimens (~ 12.7 x 25.4 mm and 25.4 x 25.4 mm) of PCEA nuclear graphite in ambient airflow, measured the total gasification flux at weight losses up to 41.5% and temperatures (893-1015 K) characteristics of those for in-pores gasification Mode (a) and in-pores diffusion-limited Mode (b). The chemical kinetics parameters for the gasification of PCEA graphite are determined using a multi-parameters optimization algorithm from the measurements of the total gasification rate and transient weight loss in experiments. These parameters are: (i) the pre-exponential rate coefficients and the Gaussian distributions and values of specific activation energies for adsorption of oxygen and desorption of CO gas; (ii) the specific activation energy and pre-exponential rate coefficient for the breakup of stable un-dissociated C(O2) oxygen radicals to form stable (CO) complexes; (iii) the specific activation energy and pre-exponential coefficient for desorption of CO2 gas and; (iv) the initial surface area of reactive free sites per unit mass. This area is consistently 13.5% higher than that for nuclear graphite grades of NBG-25 and IG-110 and decreases inversely proportional with the square root of the initial mass of the graphite specimens in the experiments. Experimental measurements successfully validate the chemical-reactions kinetics model that calculates continuous Arrhenius curves of the total gasification flux and the production rates of CO and CO2 gases. The model results at different total weight losses agree well with measurements and expand beyond the temperatures in the experiments to the diffusion-limited mode of gasification. Also calculated are the production rates of CO and CO2 gases and their relative contributions to the total gasification rate in the experiments as functions of temperature, for total weight losses of 5% and 10%.

kinetics↗

Tall Tower Wind Energy Monitoring and Numerical Model Validation in Northern Nevada

The main objectives of this project were to conduct a tall-tower and sodar field campaign in complex terrain, investigate wind properties relevant to wind energy assessment, and evaluate high-resolution models with fixed and adaptive grid structures. Two 60-m towers at Virginia Peak ridges near Washoe Valley, Nevada, were instrumented with cup and vane anemometers as well as sonic anemometers, and an acoustic sounder (hereafter sodar) was installed near one of the towers. The towers were located 2,700 m apart with a vertical distance of 140 m elevation between their bases. Each tower had a downhill exposure of rolling complex terrain, with the nearby valley floor 3,200 m to the west and 800 m below the summit. Cup anemometers were installed at both towers at 20, 40, and 60 m, wind vanes at 20 and 60 m, and sonic anemometers at 20 and 60 m. The sodar measurements were nominally provided every 10 m in vertical distance from 40 to 200 m with the quality of the data generally decreasing with height. Surface air temperature, atmospheric pressure, and radiation measurements were conducted at 1.5 m AGL at both of the towers. Although the plan was to conduct a 1-year period of data collection, we extended the period (October 5, 2012 through February 24, 2014) to cover for possible data loss from instrument or communication problems. We also present a preliminary analysis of the towers and sodar data, including a detailed inventory of available and missing data as well as outliers. The analysis additionally includes calculation of the Weibull parameters, turbulence intensity, and initial computation of wind power density at various heights.

17 WIND ENERGY↗

LIVVkit 2.1: automated and extensible ice sheet model validation

A collection of scientific analyses, metrics, and visualizations for robustvalidation of ice sheet models is presented using the Land Ice Verificationand Validation toolkit (LIVVkit), version 2.1, and the LIVVkit Extensionsrepository (LEX), version 0.1. This software collection targets stand-aloneice sheet or coupled Earth system models, and handles datasets and analysesthat require high-performance computing and storage. LIVVkit aims to enableefficient and fully reproducible workflows for postprocessing, analysis, andvisualization of observational and model-derived datasets in a shareableformat, whereby all data, methodologies, and output are distributed to usersfor evaluation. Extending from the initial LIVVkit software framework, wedemonstrate Greenland ice sheet simulation validation metrics using thecoupled Community Earth System Model (CESM) as well as an idealizedstand-alone high-resolution Community Ice Sheet Model, version 2 (CISM2),coupled to the Albany/FELIX velocity solver (CISM-Albany or CISM-A). As oneexample of the capability, LIVVkit analyzes the degree to which modelscapture the surface mass balance (SMB) and identifies potential sources ofbias, using recently available in situ and remotely sensed data ascomparison. Related fields within atmosphere and land surface models, e.g.,surface temperature, radiation, and cloud cover, are also diagnosed. Appliedto the CESM1.0, LIVVkit identifies a positive SMB bias that is focusedlargely around Greenland's southwest region that is due to insufficientablation.

58 GEOSCIENCES↗

Foundation Heat Exchanger Final Report: Demonstration, Measured Performance, and Validated Model and Design Tool

Geothermal heat pumps, sometimes called ground-source heat pumps (GSHPs), have been proven capable of significantly reducing energy use and peak demand in buildings. Conventional equipment for controlling the temperature and humidity of a building, or supplying hot water and fresh outdoor air, must exchange energy (or heat) with the building's outdoor environment. Equipment using the ground as a heat source and heat sink consumes less non-renewable energy (electricity and fossil fuels) because the earth is cooler than outdoor air in summer and warmer in winter. The most important barrier to rapid growth of the GSHP industry is high first cost of GSHP systems to consumers. The most common GSHP system utilizes a closed-loop ground heat exchanger. This type of GSHP system can be used almost anywhere. There is reason to believe that reducing the cost of closed-loop systems is the strategy that would achieve the greatest energy savings with GSHP technology. The cost premium of closed-loop GSHP systems over conventional space conditioning and water heating systems is primarily associated with drilling boreholes or excavating trenches, installing vertical or horizontal ground heat exchangers, and backfilling the excavations. This project investigates reducing the cost of horizontal closed-loop ground heat exchangers by installing them in the construction excavations, augmented when necessary with additional trenches. This approach applies only to new construction of residential and light commercial buildings or additions to such buildings. In the business-as-usual scenario, construction excavations are not used for the horizontal ground heat exchanger (HGHX); instead the HGHX is installed entirely in trenches dug specifically for that purpose. The potential cost savings comes from using the construction excavations for the installation of ground heat exchangers, thereby minimizing the need and expense of digging additional trenches. The term foundation heat exchanger (FHX) has been coined to refer exclusively to ground heat exchangers installed in the overcut around the basement walls. The primary technical challenge undertaken by this project was the development and validation of energy performance models and design tools for FHX. In terms of performance modeling and design, ground heat exchangers in other construction excavations (e.g., utility trenches) are no different from conventional HGHX, and models and design tools for HGHX already exist. This project successfully developed and validated energy performance models and design tools so that FHX or hybrid FHX/HGHX systems can be engineered with confidence, enabling this technology to be applied in residential and light commercial buildings. The validated energy performance model also addresses and solves another problem, the longstanding inadequacy in the way ground-building thermal interaction is represented in building energy models, whether or not there is a ground heat exchanger nearby. Two side-by-side, three-level, unoccupied research houses with walkout basements, identical 3,700 ft{sup 2} floor plans, and hybrid FHX/HGHX systems were constructed to provide validation data sets for the energy performance model and design tool. The envelopes of both houses are very energy efficient and airtight, and the HERS ratings of the homes are 44 and 45 respectively. Both houses are mechanically ventilated with energy recovery ventilators, with space conditioning provided by water-to-air heat pumps with 2 ton nominal capacities. Separate water-to-water heat pumps with 1.5 ton nominal capacities were used for water heating. In these unoccupied research houses, human impact on energy use (hot water draw, etc.) is simulated to match the national average. At House 1 the hybrid FHX/HGHX system was installed in 300 linear feet of excavation, and 60% of that was construction excavation (needed to construct the home). At House 2 the hybrid FHX/HGHX system was installed in 360 feet of excavation, 50% of which was construction excavation. There are six pipes in all excavations (three parallel circuits - out and back), and the multiple instances of FHX and/or HGHX are all connected in series. The working fluid is 20% by weight propylene glycol in water. Model and design tool development was undertaken in parallel with constructing the houses, installing instrumentation, and monitoring performance for a year. Several detailed numerical models for FHX were developed as part of the project. Essentially the project team was searching for an energy performance model accurate enough to achieve project objectives while also having sufficient computational efficiency for practical use in EnergyPlus. A 3-dimensional, dual-coordinate-system, finite-volume model satisfied these criteria and was included in the October 2011 EnergyPlus Version 7 public release after being validated against measured data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Foundation Heat Exchanger Final Report: Demonstration, Measured Performance, and Validated Model and Design Tool

Geothermal heat pumps, sometimes called ground-source heat pumps (GSHPs), have been proven capable of significantly reducing energy use and peak demand in buildings. Conventional equipment for controlling the temperature and humidity of a building, or supplying hot water and fresh outdoor air, must exchange energy (or heat) with the building's outdoor environment. Equipment using the ground as a heat source and heat sink consumes less non-renewable energy (electricity and fossil fuels) because the earth is cooler than outdoor air in summer and warmer in winter. The most important barrier to rapid growth of the GSHP industry is high first cost of GSHP systems to consumers. The most common GSHP system utilizes a closed-loop ground heat exchanger. This type of GSHP system can be used almost anywhere. There is reason to believe that reducing the cost of closed-loop systems is the strategy that would achieve the greatest energy savings with GSHP technology. The cost premium of closed-loop GSHP systems over conventional space conditioning and water heating systems is primarily associated with drilling boreholes or excavating trenches, installing vertical or horizontal ground heat exchangers, and backfilling the excavations. This project investigates reducing the cost of horizontal closed-loop ground heat exchangers by installing them in the construction excavations, augmented when necessary with additional trenches. This approach applies only to new construction of residential and light commercial buildings or additions to such buildings. In the business-as-usual scenario, construction excavations are not used for the horizontal ground heat exchanger (HGHX); instead the HGHX is installed entirely in trenches dug specifically for that purpose. The potential cost savings comes from using the construction excavations for the installation of ground heat exchangers, thereby minimizing the need and expense of digging additional trenches. The term foundation heat exchanger (FHX) has been coined to refer exclusively to ground heat exchangers installed in the overcut around the basement walls. The primary technical challenge undertaken by this project was the development and validation of energy performance models and design tools for FHX. In terms of performance modeling and design, ground heat exchangers in other construction excavations (e.g., utility trenches) are no different from conventional HGHX, and models and design tools for HGHX already exist. This project successfully developed and validated energy performance models and design tools so that FHX or hybrid FHX/HGHX systems can be engineered with confidence, enabling this technology to be applied in residential and light commercial buildings. The validated energy performance model also addresses and solves another problem, the longstanding inadequacy in the way ground-building thermal interaction is represented in building energy models, whether or not there is a ground heat exchanger nearby. Two side-by-side, three-level, unoccupied research houses with walkout basements, identical 3,700 ft{sup 2} floor plans, and hybrid FHX/HGHX systems were constructed to provide validation data sets for the energy performance model and design tool. The envelopes of both houses are very energy efficient and airtight, and the HERS ratings of the homes are 44 and 45 respectively. Both houses are mechanically ventilated with energy recovery ventilators, with space conditioning provided by water-to-air heat pumps with 2 ton nominal capacities. Separate water-to-water heat pumps with 1.5 ton nominal capacities were used for water heating. In these unoccupied research houses, human impact on energy use (hot water draw, etc.) is simulated to match the national average. At House 1 the hybrid FHX/HGHX system was installed in 300 linear feet of excavation, and 60% of that was construction excavation (needed to construct the home). At House 2 the hybrid FHX/HGHX system was installed in 360 feet of excavation, 50% of which was construction excavation. There are six pipes in all excavations (three parallel circuits - out and back), and the multiple instances of FHX and/or HGHX are all connected in series. The working fluid is 20% by weight propylene glycol in water. Model and design tool development was undertaken in parallel with constructing the houses, installing instrumentation, and monitoring performance for a year. Several detailed numerical models for FHX were developed as part of the project. Essentially the project team was searching for an energy performance model accurate enough to achieve project objectives while also having sufficient computational efficiency for practical use in EnergyPlus. A 3-dimensional, dual-coordinate-system, finite-volume model satisfied these criteria and was included in the October 2011 EnergyPlus Version 7 public release after being validated against measured data.

15 GEOTHERMAL ENERGY↗

Characterization Report on Fuels for NEAMS Model Validation

ABSTRACT U3Si2 has become a material of interest for its potential as an accident tolerant fuel used in commercial light water reactors. In order to better understand the nature of the 5f-electrons and mechanisms that govern electrical and heat transport in U3Si2, and to accurately model this compound at all relevant temperatures we have performed detailed studies of this material by means of the heat capacity, electrical resistivity, Seebeck and Hall effects, and thermal conductivity. Polycrystalline samples of U3Si2 were prepared by arc-melting stoichiometric amounts of elemental U and Si. All the results obtained, especially small magneto-resistivity, large low-temperature heat capacity, and characteristic dependence of the Seebeck coefficient, point to delocalized nature of 5f-electrons in U3Si2. The thermal conductivity is ~8.5 W/m-K at room temperature and we show that the lattice part of the total thermal conductivity is small, with electrons dominating heat transport above 300 K. This knowledge of the details of the heat transport in U3Si2 will be useful for researchers working on modeling and simulations of this new advanced fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The executive disruption model of tinnitus distress: Model validation in two independent datasets using factor score regression

This study presents the executive disruption model (EDM) of tinnitus distress and subsequently validates it statistically using two independent datasets (the Construction Dataset: n = 96 and the Validation Dataset: n = 200). The conceptual EDM was first operationalised as a structural causal model (construction phase). Then multiple regression was used to examine the effect of executive functioning on tinnitus-related distress (validation phase), adjusting for the additional contributions of hearing threshold and psychological distress. For both datasets, executive functioning negatively predicted tinnitus distress score by a similar amount (the Construction Dataset: β = −3.50, p = 0.13 and the Validation Dataset: β = −3.71, p = 0.02). Theoretical implications and applications of the EDM are subsequently discussed; these include the predictive nature of executive functioning in the development of distressing tinnitus, and the clinical utility of the EDM.

Clarke, Nathan A.↗

Model Validation and Demonstration of a Hydrogen Fuel Cell Parcel Delivery Truck

With an emphasis on reducing fossil fuel consumption and emissions, major delivery service corporations have begun deploying and operating Class 6 battery electric delivery vans. Fuel cell hybrid delivery vans offer a zero emissions solution with extended range and route planning flexibility. This paper follows a prior publication [1] on the vehicle modeling and design and presents demonstration data and a validation of the prior modeling and design effort. Here, the validation exercise shows that the modeling tools predict performance and energy efficiency within 5% for most of the routes, while the demonstration data shows that in service operation fuel economy was over 14 km/kg of hydrogen gas. In addition, results from a range test showed the vehicle design and onboard hydrogen storage was able to surpass the design target range of 200 km.

08 HYDROGEN↗

Report on THMC Modeling of the Near Field Evolution of a Generic Clay Repository: Model Validation and Demonstration

Shale and clay-rich rock formations have been considered as potential host rocks for geological disposal of high-level radioactive waste throughout the world. Coupled thermal, hydrological, mechanical, and chemical (THMC) processes have a significant impact on the long-term safety of a repository in this type of rocks. For example, the excavation damaged zone (EDZ) near repository tunnels can modify local permeability (resulting from induced fractures), potentially leading to less confinement capability. Maximum allowable temperature is one of the most important design variables for a geological repository, because it determines waste package spacing, distance between disposal galleries, and therefore the overall size (and cost) of the repository for a given amount of waste. This report documents results from four R&D activities to address the above concerns: (1) development and validation of constitutive relationships (Chapter 2); (2) development of a discrete fracture network (DFN) model for investigating coupled processes in the EDZ (Chapter 3); (3) development and validation of a THM model for the Full-Scale Emplacement Experiment (FE) tests at Mont Terri, Switzerland (Chapter 4); and (4) investigation of high-temperature impacts, including both laboratory and modeling studies (Chapter 5). The overall objectives of these activities are to provide an improved understanding of and advanced modeling capabilities for EDZ evolution in clay repositories and the associated coupled processes, and to develop a technical basis for the maximum allowable temperature for a clay repository.

54 ENVIRONMENTAL SCIENCES↗

1:50 Scale Testing of Three Floating Wind Turbines at MARIN and Numerical Model Validation Against Test Data

The primary goal of the basin model test program discussed herein is to properly scale and accurately capture physical data of the rigid body motions, accelerations and loads for different floating wind turbine platform technologies. The intended use for this data is for performing comparisons with predictions from various aero-hydro-servo-elastic floating wind turbine simulators for calibration and validation. Of particular interest is validating the floating offshore wind turbine simulation capabilities of NREL’s FAST open-source simulation tool. Once the validation process is complete, coupled simulators such as FAST can be used with a much greater degree of confidence in design processes for commercial development of floating offshore wind turbines. The test program subsequently described in this report was performed at MARIN (Maritime Research Institute Netherlands) in Wageningen, the Netherlands. The models considered consisted of the horizontal axis, NREL 5 MW Reference Wind Turbine (Jonkman et al., 2009) with a flexible tower affixed atop three distinct platforms: a tension leg platform (TLP), a spar-buoy modeled after the OC3 Hywind (Jonkman, 2010) and a semi-submersible. The three generic platform designs were intended to cover the spectrum of currently investigated concepts, each based on proven floating offshore structure technology. The models were tested under Froude scale wind and wave loads. The high-quality wind environments, unique to these tests, were realized in the offshore basin via a novel wind machine which exhibits negligible swirl and low turbulence intensity in the flow field. Recorded data from the floating wind turbine models included rotor torque and position, tower top and base forces and moments, mooring line tensions, six-axis platform motions and accelerations at key locations on the nacelle, tower, and platform. A large number of tests were performed ranging from simple free-decay tests to complex operating conditions with irregular sea states and dynamic winds.

17 WIND ENERGY↗

Dynamic Model Validation of PV Inverters Under Short-Circuit Conditions: Preprint

Photovoltaic (PV) modules have dramatically decreased in price in the past few years, spurring the expansion of photovoltaic deployment. Residential and commercial rooftop installations are connected to the distribution network; large-scale installation PV power plants (PVPs) have benefited from tax incentives and the low cost of PV modules. As the level penetration of PV generation increases, the impact on power system reliability will also be greater. Utility power system planners must consider the role of PV generation in power systems more realistically by representing PV generation in dynamic stability analyses. Dynamic models of PV inverters have been developed in the positive sequence representation. NREL has developed a PV inverter dynamic model in PSCAD/EMTDC. This paper validates the dynamic model with an actual hardware bench test conducted by Southern California Edison's Distributed Energy Resources laboratory. All the fault combinations -- symmetrical and unsymmetrical -- were performed in the laboratory. We compare the simulation results with the bench test results.

14 SOLAR ENERGY↗