Search NASA⌕ Search

SEARCH · Search NASA

Results for “MONITORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Smart Refractory Sensors Development for Corrosion and Erosion Monitoring in High Temperature Systems

To optimize the operation and functioning of high temperature systems such as slagging gasifiers, coal boilers and glass/steel melters, it is important to monitor corrosion and erosion of refractory used in such systems. Corrosion test strategies are generally based on continuous gravimetric and chemical reactivity monitoring at operational temperatures (750°-1500°C). Both thermocouples and failure sensors and arrays would be useful to monitor the health of any refractory or coatings in these systems. Many of such type of sensors are installed into the systems through open access ports within the refractory; however, there are some disadvantages of this approach where corrosive/erosive gas and molten materials can penetrate and compromise the system. The current work presents the development and performance demonstration of smart refractory with embedded high temperature sensors such as thermocouples, thermistors, and various spallation/crack monitoring sensors, which may be used within a variety of refractory brick in different high temperature processes and applications. The main feature of this technology is that electroceramic based sensors are embedded into smart refractory without significantly impact to the intrinsic properties of the refractory. This technology circumvents the need to insert an isolated monolithic, stand-alone sensor into the refractory via an access port. This technological approach guarantees the integrity and the chemical stability of the materials used in the sensor fabrication within the harsh environment and does not introduce molten material (such as slag) penetration pathways within the refractory. One interesting and important aspect of this innovation is that these embedded sensors can be used to in situ monitoring processes such as chemical reactions and at the same time give information and a deeper understanding of the corrosion and erosion process of the refractory within the system. As stated above, the objective of our work is to develop high-temperature sensors composed of electroceramic materials that are chemically stable at high temperatures (750°-1500°C) and high pressures (up to 1000 psi) that can be used in monitoring corrosion and erosion process in refractory used in high energy systems. The high-temperature sensors investigated in this work were composed of various oxide composites directly embedded into the refractory oxides. The composites used for this work were synthesized by a mixed-oxide route. Metal oxides were inserted within a matrix material composed of refractory oxides (Al2O3, ZrO2, etc.). The physical and electrical properties were specifically manipulated by altering the level of percolation of the conductive species (metal oxides) within the refractory constituent (refractory oxide). Prior to the development of the high-temperature sensors, the oxides composites developed in this study were sintered up to 1600°C under oxidizing atmosphere in order to investigate densification, microstructural evolution, phase development, and their thermoelectrical performance as a function of the composition. The 4-point DC conductivity measurements were performed between 100°-1500°C. The sensors were fabricated from the composite materials by 3D-printing or screen-printing methods into the refractory brick during the consolidation process. An example of one of these embedded sensors consisted of an electroceramic-based thermocouple fabricated with two separate oxide composite compositions which were patterned to produce a couple within the interior of a refractory matrix. The thermocouple successfully displayed thermoelectric voltage trend (as a function of temperature), and the voltage was 220.0 mV around 1400 °C. Corrosion tests on the refractory embedded sensors were performed. To evaluate corrosion in the refractory brick an in-house glass composition was prepared and pressed into pellets and delivered into a pre-cut cavity in the brick. Corrosion experiments results showed the glass penetrated the brick over a 90 h period, and the penetration of the glass through the brick could be monitored by both an amperometric and voltametric based sensor. With this experiment, it was demonstrated that the embedded sensor could dynamically monitor the corrosion process.

20 FOSSIL-FUELED POWER PLANTS↗

The Utility of Satellites and Autonomous Remote Sensing Platforms for Monitoring Offshore Aquaculture Farms: A Case Study for Canopy Forming Kelps

The emerging sector of offshore kelp aquaculture represents an opportunity to produce biofuel feedstock to help meet growing energy demand. Giant kelp represents an attractive aquaculture crop due to its rapid growth and production, however precision farming over large scales is required to make this crop economically viable. These demands necessitate high frequency monitoring to ensure outplant success, maximum production, and optimum quality of harvested biomass, while the long distance from shore and large necessary scales of production makes in person monitoring impractical. Remote sensing offers a practical monitoring solution and nascent imaging technologies could be leveraged to provide daily products of the kelp canopy and subsurface structures over unprecedented spatial scales. Here, we evaluate the efficacy of remote sensing from satellites and aerial and underwater autonomous vehicles as potential monitoring platforms for offshore kelp aquaculture farms. Decadal-scale analyses of the Southern California Bight showed that high offshore summertime cloud cover restricts the ability of satellite sensors to provide high frequency direct monitoring of these farms. By contrast, daily monitoring of offshore farms using sensors mounted to aerial and underwater drones seems promising. Small Unoccupied Aircraft Systems (sUAS) carrying lightweight optical sensors can provide estimates of canopy area, density, and tissue nitrogen content on the time and space scales necessary for observing changes in this highly dynamic species. Underwater color imagery can be rapidly classified using deep learning models to identify kelp outplants on a longline farm and high acoustic returns of kelp pneumatocysts from side scan sonar imagery signal an ability to monitor the subsurface development of kelp fronds. Current sensing technologies can be used to develop additional machine learning and spectral algorithms to monitor outplant health and canopy macromolecular content, however future developments in vehicle and infrastructure technologies are necessary to reduce costs and transcend operational limitations for continuous deployment in an offshore setting.

54 ENVIRONMENTAL SCIENCES↗

Field Test Bed for Vadose-Zone Monitoring Approaches - 20404

In the Central Plateau at the U.S. Department of Energy Hanford Site, a large inventory of contaminants resides in unsaturated sediments within the approximately 100-meter-thick vadose zone, posing a potential continuing risk to groundwater. Vadose zone remedies used to address these contaminants will require performance monitoring to provide feedback during implementation and for long-term verification that remedial action objectives have been met. Passive approaches may also need long-term monitoring to demonstrate that the flux of contaminants from the vadose zone to the groundwater are below thresholds established to meet groundwater protection goals. Collection of physical (e.g., groundwater or sediment) samples is a common method for identifying contaminant concentration distributions, but this approach is limited by the number of locations and the frequency with which data can be collected. In situ vadose zone measurements have evolved over the past few years to include key measurements of water content, soil water pressure, temperature, and chemical concentration. However, the current generation of sensors is designed for relatively short-term use in near-surface soils or sediments. Geophysical methods have been evolving but are also limited in that they have not been designed for the specific long-term vadose zone monitoring needs at the Hanford Site. Overall, monitoring under unsaturated conditions can be difficult due to the need to install and maintain instrumentation over a large area and depth and the need to identify preferential flow pathways due to geologic and chemical heterogeneities over long periods. Thus, a vadose zone monitoring test bed was initiated to address these challenges and identify cost-effective approaches for implementation and postclosure monitoring of the deep vadose zone. The monitoring test bed is expected to provide valuable field-scale information for the design of vadose zone monitoring systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monitoring Potential Transport of Radioactive Contaminants in Shallow Ephemeral Channels: FY2019

Desert Research Institute (DRI) conducted a field assessment of the potential for contaminated soil to be transported from the Smoky Site Contamination Area (CA) because of storm runoff. This activity supported U.S. Department of Energy (DOE) Environmental Management Nevada Program (EM NV) efforts to establish post-closure monitoring plans for the Smoky Site Soils Corrective Action Unit (CAU) 550. The work was intended to confirm the likely mechanism of transport and determine the meteorological conditions that might cause the movement of contaminated soils, as well as determine the particle size fraction most closely associated with transported radionuclide-contaminated soils. These data will facilitate the design of the appropriate post-closure monitoring program. In 2011, DRI installed a meteorological monitoring station on the west side of the Smoky Site CA and a hydrologic (runoff) monitoring station within the CA, near the east side. The meteorological station collected air temperature, wind speed, wind direction, relative humidity, precipitation, solar radiation, barometric pressure, soil temperature, and soil water content data. The maximum, minimum, and average or total values (as appropriate) for each of these parameters were recorded for each 10-minute interval. The maximum, minimum, and average water depth in the flume installed at the hydrologic station were also recorded for each 10-minute interval. This report presents the data collected from these stations during fiscal year (FY) 2019. During the FY2019 reporting period, the warmest months were June, July, and August and the coldest were December and February. The highest monthly solar radiation (i.e., sunshine) values were recorded in June, July, and August, whereas December through February had the lowest solar radiation values. Monthly mean wind speeds were highest in the spring (April) and early summer (June). Winds were predominantly from the north, except in February, July, August, and September when winds were mostly from the west. The monthly average relative humidity ranged from 17 percent to approximately 60 percent. Humidity was lowest in the summer and highest in the winter. Monthly total precipitation ranged from 0.0 during August and September to 2.22 inches (in) (56.39 millimeters [mm]) in February. Total precipitation for FY2019 was 7.83 in (198.88 mm). During the reporting period, a single, nonzero, flow event was recorded at the flume. This occurred over two days between March 6 and 7, 2019, in response to 1.16 in (29.46 mm) of precipitation falling within 9.3 hours on March 6, 2019. This event produced a peak water depth of 0.39 in (0.99 centimeters [cm]) in the flume, and runoff was measured for approximately 23.5 hours. However, the maximum recorded flow depth was less than the limit for flow discharge and velocity that can be calculated for the six-inch (15 cm) throat of a Parshall flume. The runoff event produced insufficient flow velocities through the natural channel to cause local erosion and transport of bedload materials. No bedload samples were collected for radiological analysis. Observing meteorological and environmental conditions that lead to storm runoff will help identify the parameters and threshold conditions that should be incorporated into post-closure monitoring plans for this and similar Soils CAU sites. Routine monitoring of meteorological and hydrologic parameters at the Smoky Site CA has been discontinued at the request of EM NV, effective at the conclusion of FY2019. Environmental data acquisition was completed and the meteorological and runoff monitoring stations were removed from the Smoky Site on October 15, 2019.

54 ENVIRONMENTAL SCIENCES↗

Radiological Monitoring Plan for the Oak Ridge Y-12 National Security Complex: Surface Water

DOE Order 458.1 requires that dose estimates consider contributions from all facilities. In the Y-12 Radiological Monitoring Plan (RMP), surface water is monitored at points that reflect individual facilities, as well as at points that reflect the combined contributions of all facilities. This monitoring plan does not consider other potential routes (i.e., airborne releases and food chains). Thus, a complete determination of total effective dose (TED) cannot be made based on this plan alone. The other routes from Y-12, and all routes from other DOE facilities on the Oak Ridge Reservation (e.g., Oak Ridge National Laboratory (ORNL) and The Heritage Center), must be considered in order to satisfy DOE Order 458.1 requirements. Determination of TED from all sites and pathways is done through the use of dose-assessment models and is documented in the Annual Site Environmental Report. This monitoring plan provides adequate monitoring goals for Y-12 surface water releases to provide input of sufficient sensitivity and accuracy to reliably determine the Y-12 surface water component of the TED. The routine radiological monitoring program is designed to monitor effluents at four types of locations: (1) treatment facilities, (2) other point and area source discharges, (3) instream locations, and (4) production building roof run-off. With this sampling and analysis program, data will be obtained on primary point sources as well as on locations that represent the composite of other potential sources. This plan will be reviewed periodically to determine necessary modifications to the sampling frequencies, parameters, and locations. Modifications, if any, will be based on the analysis of the previous data and its effectiveness in satisfying the objectives of this plan. Appendix A contains graphs of the sum of the DCS fractions for locations and frequencies contained in a previous version of this plan. The data was collected from January 2009 through December 2019. Each sample was analyzed, and each result was divided by the appropriate DCS to compute a DCS fraction. These fractions were summed for all isotopes. According to DOE –STD-1196-2011, the annual average of these sums should be below 1.

54 ENVIRONMENTAL SCIENCES↗

Seismic monitoring of a small CO 2 injection using a multi-well DAS array: Operations and initial results of Stage 3 of the CO 2 CRC Otway project

Active time-lapse seismic is widely employed for monitoring CO 2 geosequestration due to its ability to track the distribution of fluids in space and time. However, standard 4D seismic monitoring suffers from several challenges, including high cost, disruption to other land uses, and, consequently, relatively large intervals between monitor surveys. Some of these challenges can be mitigated using permanently installed sources and receivers. Such an approach was tested at the CO 2 CRC Otway site by continuous offset VSP monitoring of 15,000 t of supercritical CO 2 injected into an aquifer 1,500 m deep with nine permanent seismic sources (surface orbital vibrators or SOVs) and five downhole fibre-optic receivers. This continuous monitoring is complemented by multi-well 4D VSP using a mobile vibroseis source and the same DAS receivers, which included one baseline and two monitor surveys after injection of 4,000 and 12,000 t of CO 2 . The continuous DAS-SOV monitoring detected an abrupt increase of travel times below the injection interval on the second day of injection (after injection of 300 t of CO 2 ) and tracked the growth of the areal CO 2 plume by mapping changes of reflection amplitudes. The plume is also detected by time-lapse changes of reflection amplitudes in multi-well 4D VSPs. The plume images obtained from continuous offset VSP and 4D VSP are broadly consistent with each other but with some differences due to differences in illumination, lateral variations of velocities and seismic anisotropy. Furthermore, these differences also serve as a measure of uncertainty of 4D VSP images.

4D VSP↗

Digital-Twin-Enabling Technologies for Online Condition Monitoring of Nuclear Power Plant Components

Online condition monitoring is an area of active research that may enable optimized scheduling, maintenance, and safety of nuclear power plant components, reducing unnecessary derates while simultaneously improving operational capacity. Digital twins (DTs) are one avenue to conduct online condition monitoring and are currently being explored by national laboratories and universities alike. DTs for online condition monitoring are, in essence, state concurrent models that emulate a physical process which predicts a parameter and compares it against a measured value. A DT’s goal is to provide additional insights by combining and interpreting various sources of information for preventative maintenance scheduling optimization or early fault detection. DTs for condition monitoring are projected to be valuable for meeting requirements under 10 CFR 50.55a, “Codes and Standards,” and 10 CFR 50.65, “Requirements for Monitoring the Effectiveness of Maintenance at Nuclear Power Plants”. However, DT technologies are still under significant development, and the process for developing a DT for condition monitoring has not been formalized. Therefore, in this work, we present an initial framework for developing a DT, discuss and review the various challenges and considerations for DT deployment, and identify the opportunities that a DT can improve. The presented framework is intended to help developers formulate a strategy when approaching DT development for condition monitoring. In conclusion, a DT use case for a reactor coolant pump is presented to demonstrate the proposed framework.

advanced sensor instrumentation↗

Evaluation of Station Performance of the Idaho National Laboratory Seismic Monitoring Network Using Network Detection Thresholds

The Idaho National Laboratory (INL) Seismic Monitoring Network is located in eastern Idaho and monitors a portion of the intermountain seismic belt. It has been in place for 50 yr and has undergone several major changes, the most recent of which has been the transition to the Antelope real‐time acquisition system and the implementation of automatic phase picking algorithms to aid in analysis. This study discusses the efforts to evaluate the performance of the INL seismic monitoring network (and other surrounding stations) using the new real‐time acquisition system. The method outlined by Wilson et al. (2021) is used to develop an empirical relationship between the observability of local earthquakes as a function of magnitude and distance. This relationship is used to produce detection thresholds for Pwaves for all stations of interest. The INL seismic network has two main goals: monitor tectonic‐and volcanic‐related events and measure ground motions for input into seismic hazard analysis. Because of these two overall objectives, several seismic stations have been installed near critical facilities and, therefore, are not as quiet as stations that are used primarily for earthquake detection. This is reflected in their detection thresholds, which are much smaller for stations away from facilities. This study shows that the INL Seismic Monitoring Network is able to detect earthquakes near INL facilities with M L > 1.2, with redundancies built in to ensure this sensitivity even if data became unavailable from some stations. This study also shows “holes” in the monitoring network where the detection of smaller earthquakes is highly dependent on sparsely placed seismic stations. In conclusion, the results of this study will be used to govern plans for expansion of earthquake monitoring in Idaho and the surrounding region and to fine‐tune the detection thresholds for individual stations.

58 - GEOSCIENCES↗

Historical Data Analysis Supporting the Data Quality Objectives for the INL Site Environmental Soil Monitoring Program

This document represents the initial evaluation and soil monitoring proposed by Battelle Energy Alliance, LLC (BEA) in 2015. The evaluation included analyses of historical soil monitoring data and soil inventories, current emission estimates, and modeled potential deposition/accumulation patterns. The initially proposed monitoring included a 5-year rotation of in-situ gamma measurements augmented by soil sampling with laboratory analyses near each major active and some inactive facilities. It also proposed rotational in-situ gamma measurements and soil sampling at two centrally located onsite air monitoring locations coinciding with sampling at the traditional offsite soil monitoring locations. The chosen alternative includes only physical soil sampling with laboratory analysis and only at the Radioactive Waste Management Complex (RWMC), the two air monitors and the offsite locations as documented in Data Quality Objectives Supporting the Environmental Soil Monitoring Program for the Idaho National Laboratory (INL) Site, INL/EXT-15-34909, Revision 0, February 2016. The data and evaluations in this document are valid for comparisons with future soil data that may be collected in many INL site locations.

54 ENVIRONMENTAL SCIENCES↗

Technical Assessment of the Application of Digital Twin and Prognostic Tools for Condition Monitoring

This report was prepared for the U.S. Nuclear Regulatory Commission (NRC) to present use cases of the application of advanced technologies toward meeting the current and future regulatory requirements for maintenance and condition monitoring of structures, systems, and components (SSCs). The advanced technologies considered in this work, collectively referred to as digital twin (DT) technologies, are advanced sensors and instrumentation, data analytics, machine learning and artificial intelligence (ML/AI), and physics-based models. The report presents two use cases of reactor coolant pumps (RCPs) and heat pipes in nuclear power plants (NPPs) with technical and regulatory considerations and opportunities in using advanced technologies for conditional monitoring. Key findings from the exploration of these considerations are as follows: - Uncertainties in sensor data and model predictions must be rigorously addressed through validation and verification processes - Regulatory compliance is paramount, necessitating data driven models to be developed in line with existing codes and standards, as well as considering potential future guidelines for advanced reactors - Explainability and transparency in ML/AI models are essential for developing operator trust and regulatory review, including methods that enhance the interpretability of complex data-driven predictions - Condition monitoring programs must be evaluated for their effectiveness in reducing maintenance-preventable function failures (MPFF) and aligning with plant performance criteria - The deployment of advanced technologies for condition monitoring could lead to a transition from periodic to continuous monitoring, thereby optimizing maintenance schedules - Collaborative efforts between industry stakeholders, regulatory bodies, and technology developers are crucial for the successful adoption of advanced technologies for condition monitoring systems in nuclear facilities In summary, the introduction of advanced technologies into condition monitoring programs represents a significant leap forward in the domain of NPP maintenance. By harnessing the capabilities of advanced sensors, data analytics, and ML/AI, NPP operators can transition from a time-based to a condition-based maintenance approach. This shift can potentially enhance the reliability and safety of critical plant components while optimizing maintenance efforts and minimizing unnecessary outages. The NRC is continuing to explore the regulatory aspects of advanced technologies as part of inservice inspection and inservice testing (ISI and IST) programs by pursuing additional research in this technical area.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Wildfire Smoke Adjustment Factors for Low-Cost and Professional PM 2.5 Monitors with Optical Sensors

Air quality monitors using low-cost optical PM 2.5 sensors can track the dispersion of wildfire smoke; but quantitative hazard assessment requires a smoke-specific adjustment factor (AF). This study determined AFs for three professional-grade devices and four monitors with low-cost sensors based on measurements inside a well-ventilated lab impacted by the 2018 Camp Fire in California (USA). Using the Thermo TEOM-FDMS as reference, AFs of professional monitors were 0.85 for Grimm mini wide-range aerosol spectrometer, 0.25 for TSI DustTrak, and 0.53 for Thermo pDR1500; AFs for low-cost monitors were 0.59 for AirVisual Pro, 0.48 for PurpleAir Indoor, 0.46 for Air Quality Egg, and 0.60 for eLichens Indoor Air Quality Pro Station. We also compared public data from 53 PurpleAir PA-II monitors to 12 nearby regulatory monitoring stations impacted by Camp Fire smoke and devices near stations impacted by the Carr and Mendocino Complex Fires in California and the Pole Creek Fire in Utah. Camp Fire AFs varied by day and location, with median (interquartile) of 0.48 (0.44–0.53). Adjusted PA-II 4-h average data were generally within ±20% of PM 2.5 reported by the monitoring stations. Adjustment improved the accuracy of Air Quality Index (AQI) hazard level reporting, e.g., from 14% to 84% correct in Sacramento during the Camp Fire.

47 OTHER INSTRUMENTATION↗

Local Weather Station Design and Development for Cost-Effective Environmental Monitoring and Real-Time Data Sharing

Current weather monitoring systems often remain out of reach for small-scale users and local communities due to their high costs and complexity. This paper addresses this significant issue by introducing a cost-effective, easy-to-use local weather station. Utilizing low-cost sensors, this weather station is a pivotal tool in making environmental monitoring more accessible and user-friendly, particularly for those with limited resources. It offers efficient in-site measurements of various environmental parameters, such as temperature, relative humidity, atmospheric pressure, carbon dioxide concentration, and particulate matter, including PM 1, PM 2.5, and PM 10. The findings demonstrate the station’s capability to monitor these variables remotely and provide forecasts with a high degree of accuracy, displaying an error margin of just 0.67%. Furthermore, the station’s use of the Autoregressive Integrated Moving Average (ARIMA) model enables short-term, reliable forecasts crucial for applications in agriculture, transportation, and air quality monitoring. Furthermore, the weather station’s open-source nature significantly enhances environmental monitoring accessibility for smaller users and encourages broader public data sharing. With this approach, crucial in addressing climate change challenges, the station empowers communities to make informed decisions based on real-time data. In designing and developing this low-cost, efficient monitoring system, this work provides a valuable blueprint for future advancements in environmental technologies, emphasizing sustainability. The proposed automatic weather station not only offers an economical solution for environmental monitoring but also features a user-friendly interface for seamless data communication between the sensor platform and end users. This system ensures the transmission of data through various web-based platforms, catering to users with diverse technical backgrounds. Furthermore, by leveraging historical data through the ARIMA model, the station enhances its utility in providing short-term forecasts and supporting critical decision-making processes across different sectors.

54 ENVIRONMENTAL SCIENCES↗

Advanced Laboratory and Field Arrays: Evaluating Sampling Techniques for MHK Biological Monitoring (Task 6)

The overall goal of the task was to identify cost effective biological sampling techniques for MHK environmental monitoring. Protected, demersal, and pelagic fish and selected nektonic invertebrates were surveyed using capture and remote sensing techniques at the PacWave sites. The performance of capture and remote sensing monitoring techniques were evaluated and generic nekton monitoring indices were developed for MHK technologies and sites. In parallel to data collections at the PacWave site, the ability of regression models to characterize, detect, and predict change in acoustic data was evaluated using acoustic data collected in Admiralty Inlet, WA, during a biological monitoring study of the proposed SnoPud tidal turbine project site. Expected outcomes of these efforts included an evaluation of instrumentation and techniques used to monitor biological variability; identification of data streams that can be used to detect and quantify change; and sampling requirements to ensure detection of change in monitored variables.

13 HYDRO ENERGY↗

Development of an ERT‐Based Framework for Bentonite Buffers Monitoring From Laboratory Tests: 1. Characterizing Thermal–Hydrological–Mechanical Processes

Abstract Bentonite clay is widely used in engineered barrier systems for the permanent disposal of high‐level radioactive waste due to its low permeability, high swelling capacity, and thermal stability. However, the complex thermal‐hydrological‐mechanical (THM) processes induced by heating from decaying radioactive waste and hydration from surrounding rock can lead to heterogeneous changes that are difficult to measure and predict. This study develops an Electrical Resistivity Tomography (ERT)‐based framework for monitoring THM processes, progressing from sample‐scale to bench‐scale tests, to inform field‐scale applications. Sample‐scale tests analyzed small bentonite samples under controlled variations in water content, temperature, and porosity to establish fundamental resistivity relationships. Bench‐scale tests involved larger bentonite columns subjected to heating (up to 200°C) and hydration under controlled pressure, simulating repository conditions. ERT measurements, complemented by X‐ray CT imaging, temperature monitoring, and tracing sensors, revealed coupled THM processes, such as hydration‐induced compression, swelling, and thermal gradients, leading to complex resistivity patterns. The results demonstrate the potential of ERT for capturing THM‐induced resistivity changes, though challenges remain in upscaling and quantitative analysis. This study evaluates laboratory test capabilities and proposes future improvements for understanding THM‐induced resistivity responses. A conceptual framework for ERT implementation in field‐scale monitoring is presented, synthesizing findings from both scales and exploring how ERT data can inform long‐term modeling and reduce prediction uncertainties. Overall, this ERT‐based framework offers a robust method for monitoring bentonite buffers, aiding in early issue detection and supporting the safe long‐term disposal of radioactive waste in geological repositories, while highlighting the need for future development. Plain Language Summary Bentonite clay is crucial in engineered barrier systems (EBS) for containing high‐level radioactive waste due to its ability to absorb water, swell, seal and remain stable under high temperatures. When bentonite absorbs water and heats up from radioactive decay, it experiences complex changes in its physical and mechanical properties. Understanding these changes is important for ensuring the long‐term safety and effectiveness of EBS. This study used Electrical Resistivity Tomography (ERT), a non‐invasive method that measures electrical conductivity to monitor these changes during laboratory experiments. The ERT data revealed significant variations in resistivity corresponding to changes in water content, temperature, and density, providing detailed spatial and temporal insights into the behavior of bentonite. These findings enhance our ability to predict the long‐term performance of bentonite barriers, ensuring the safe containment of radioactive waste. By improving our understanding of bentonite's behavior, this research supports the development of more reliable and effective barrier systems for radioactive waste disposal, protecting the environment and public health. Key Points ERT monitoring was employed to capture resistivity changes in bentonite during controlled heating and hydration experiments, providing insights into THM processes ERT data reveal significant resistivity changes correlated with water content, temperature, and mechanical effects, enhancing the understanding of THM dynamics in bentonite This study explores the potential of the framework for application in field‐scale EBS monitoring, emphasizing the need for integrating additional geophysical methods for comprehensive subsurface imaging

Chen, Hang↗

rmon (Resource monitor) [SWR-24-128]

The resource monitor application provides monitoring, collection, and visualization of resource utilization in compute nodes. This package contains utilities to monitor system resource utilization (CPU, memory, disk, network). Here are the ways you can use it: -Monitor resource utilization for a compute node for a given set of resource types and process IDs. -Start a process and monitor its resource utilization. -Monitor resource utilization for a compute node asynchronously with the ability to dynamically change the resource types and process IDs being monitored. -Produce JSON reports of aggregated metrics. -Produce interactive HTML plots of the statistics.

Thom, Daniel [National Renewable Energy Laboratory↗

Machine Learning Approach for Spatiotemporal Multivariate Optimization of Environmental Monitoring Sensor Locations

Abstract Long-term environmental monitoring is critical for managing the soil and groundwater at contaminated sites. Recent improvements in state-of-the-art sensor technology, communication networks, and artificial intelligence have created opportunities to modernize this monitoring activity for automated, fast, robust, and predictive monitoring. In such modernization, it is required that sensor locations be optimized to capture the spatiotemporal dynamics of all monitoring variables as well as to make it cost-effective. The legacy monitoring datasets of the target area are important to perform this optimization. In this study, we have developed a machine-learning approach to optimize sensor locations for soil and groundwater monitoring based on ensemble supervised learning and majority voting. For spatial optimization, Gaussian process regression (GPR) is used for spatial interpolation, while the majority voting is applied to accommodate the multivariate temporal dimension. Results show that the algorithms significantly outperform the random selection of the sensor locations for predictive spatiotemporal interpolation. While the method has been applied to a four-dimensional dataset (with two-dimensional space, time, and multiple contaminants), we anticipate that it can be generalizable to higher-dimensional datasets for environmental monitoring sensor location optimization.

Siddiquee, Masudur R.↗

Sensor Recommendations for Long Term Monitoring of the F-Area Seepage Basins

In mid-2018, a new paradigm for long-term monitoring was developed after of decade of applied research projects funded by the Department of Energy’s office of Environmental Management Technology Development program. The program at SRNL was focused on transitioning complex environmental waste sites from active to passive remediations strategies. A key result of these studies was that the use of enhanced attenuation approaches at radiologically contaminated sites will result in the creation of secondary source areas in the subsurface that will require monitoring for decades. Alternative monitoring approaches are being developed and tested at the Savannah River Site’s F-Area Hazardous Waste Management Facility, the new paradigm provides innovative solutions that will significantly lower costs of monitoring through the coupling of data collection, machine learning and deterministic groundwater modeling. The foundation of this approach is a well-optimized network of sensors for measuring hydrogeochemical master variables that control, and therefore act as indicators of groundwater contaminant transport. By monitoring changes in the controlling master variables over time arising from geological and environmental shifts, predictive modelling can assist with identifying new strategies for ensuring regulatory requirements are met if trends toward conditions for potential remobilization of attenuated contaminants are detected. In this report, we evaluated commercially available single parameter sensor platforms (e.g., temperature/depth) and configurable multi-parameter sensor platforms (e.g., pH, oxidation-reduction potential, temperature, depth, dissolved oxygen, and conductivity). Each was scored using an optimization function based on how well the system supports the proposed long-term monitoring paradigm, in general, and the site-specific conditions at F-Area, in particular. Several viable sensor systems were identified. Of these, a combined platform including the In-Situ Aqua TROLL 500 multi-parameter sensor platform and the In-Situ temperature/depth sensor had the highest rating and was identified as the most suitable candidate for installation and monitoring of the master variables and potentiometric surface that control groundwater contaminant plumes emanating from the F-Area Seepage Basins. The discussion of recommended potential deployment locations builds upon recommendations made by Denham et al (2019).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dosimeter Area Monitoring Program (DAMP) Technical Basis Document

This document provides a technical basis for establishing a Dosimetry-based Area Monitoring Program (DAMP) at Lawrence Livermore National Laboratory (LLNL). A DAMP is part of a comprehensive routine monitoring program and provides information about radiation levels inside and outside of Radiologically-Controlled Areas (RCAs). The routine, hand-held radiation survey program driven by the Health Physics Discipline Action Plan (HP-DAP) helps to ensure radiological conditions within RCAs are well-characterized and routinely monitored; however, such surveys are a snapshot in time, whereas area monitoring dosimeters (AMDs) continuously monitor radiation doses in the areas where they are installed. Together, data from the hand-held radiation surveys and the DAMP provides a comprehensive picture of radiation environment at LLNL. A DAMP helps to verify the effectiveness of established engineered and administrative controls while documenting that radiation doses in RCAs are below that which requires individual monitoring. This document establishes the basis for determining which model of dosimeter to use, the exchange frequency, the occupancy factor, monitoring locations, and a method for evaluating AMD results.

61 RADIATION PROTECTION AND DOSIMETRY↗