Search NASA⌕ Search

SEARCH · Search NASA

Results for “MPC implementation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

103 records · Page 6

Transforming Aeration Energy in Water Resource Recovery Facilities (WRRFs) through Suboxic Nitrogen Removal (Final Report)

The objective of this project was to advance two key technological components—aeration control strategies and process design methodologies—to support the development and broader adoption of suboxic biological nitrogen removal (SBNR). The project focused on achieving the following three goals: • Enhance Model Predictive Control (MPC) Technology: Advance the DO/Nmaster MPC platform from its initial 2018 pilot deployment at the Chico Water Resource Recovery Facility in California to full-scale integration. This included partnering with a blower technology commercialization partner and incorporating machine learning (ML) capabilities to enable nationwide deployment. • Bridge Knowledge Gaps in SBNR Process Design: Address fundamental gaps in SBNR process understanding through controlled pilot-scale testing at a dedicated pilot facility. These efforts supported the development of robust kinetic models to inform reliable SBNR control, operational strategies, and design frameworks. • Demonstrate Full-Scale Implementation of Low DO/SBNR with ML: Transition low dissolved oxygen (DO)/SBNR coupled with ML from pilot-scale trials to full-scale demonstration in flow-through biological nutrient removal (BNR) systems, with the goal of enabling scalable, nationwide adoption in activated sludge treatment processes. The project included demonstration of SBNR at the pilot scale as performed by Hampton Roads Sanitation District (HRSD) and at the full-scale as performed by the Los Angeles County Sanitation Districts' (LACSD) Pomona Water Reclamation Plant (POWRP).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Iterative reconstruction excursions for Baryon Acoustic Oscillations and beyond

ABSTRACT The density field reconstruction technique has been widely used for recovering the baryon acoustic oscillation (BAO) feature in galaxy surveys that has been degraded due to non-linearities. Recent studies advocated adopting iterative steps to improve the recovery much beyond that of the standard technique. In this paper, we investigate the performance of a few selected iterative reconstruction techniques focusing on the BAO and the broad-band shape of the two-point clustering. We include redshift-space distortions, halo bias, and shot noise and inspect the components of the reconstructed field in Fourier space and in configuration space using both density field-based reconstruction and displacement field-based reconstruction. We find that the displacement field reconstruction becomes quickly challenging in the presence of non-negligible shot noise and therefore present surrogate methods that can be practically applied to a much more sparse field such as galaxies. For a galaxy field, implementing a debiasing step to remove the Lagrangian bias appears crucial for the displacement field reconstruction. We show that the iterative reconstruction does not substantially improve the BAO feature beyond an aggressively optimized standard reconstruction with a small smoothing kernel. However, we find taking iterative steps allows us to use a small smoothing kernel more ‘stably’, i.e. without causing a substantial deviation from the linear power spectrum on large scales. In one specific example we studied, we find that a deviation of 13 per cent in $P(k\sim 0.1\, h{\rm \,\,Mpc^{-1}})$ with an aggressive standard reconstruction can reduce to 3–4 per cent with iterative steps.

79 ASTRONOMY AND ASTROPHYSICS↗

Galaxy bias in the era of LSST: perturbative bias expansions

Upcoming imaging surveys will allow for high signal-to-noise measurements of galaxy clustering at small scales. In this work, we present the results of the Rubin Observatory Legacy Survey of Space and Time (LSST) bias challenge, the goal of which is to compare the performance of different nonlinear galaxy bias models in the context of LSST Year 10 (Y10) data. Specifically, we compare two perturbative approaches, Lagrangian perturbation theory (LPT) and Eulerian perturbation theory (EPT) to two variants of Hybrid Effective Field Theory (HEFT), with our fiducial implementation of these models including terms up to second order in the bias expansion as well as nonlocal bias and deviations from Poissonian stochasticity. Here, we consider a variety of different simulated galaxy samples and test the performance of the bias models in a tomographic joint analysis of LSST-Y10-like galaxy clustering, galaxy-galaxy-lensing and cosmic shear. We find both HEFT methods as well as LPT and EPT combined with non-perturbative predictions for the matter power spectrum to yield unbiased constraints on cosmological parameters up to at least a maximal scale of k max = 0.4 Mpc -1 for all samples considered, even in the presence of assembly bias. While we find that we can reduce the complexity of the bias model for HEFT without compromising fit accuracy, this is not generally the case for the perturbative models. We find significant detections of non-Poissonian stochasticity in all cases considered, and our analysis shows evidence that small-scale galaxy clustering predominantly improves constraints on galaxy bias rather than cosmological parameters. These results therefore suggest that the systematic uncertainties associated with current nonlinear bias models are likely to be subdominant compared to other sources of error for tomographic analyses of upcoming photometric surveys, which bodes well for future galaxy clustering analyses using these high signal-to-noise data.

79 ASTRONOMY AND ASTROPHYSICS↗

Parameter inference with non-linear galaxy clustering: accounting for theoretical uncertainties

ABSTRACT We implement euclidemulator (version 1), an emulator for the non-linear correction of the matter power spectrum, into the Markov chain Monte Carlo forecasting code montepython. We compare the performance of halofit, hmcode, and euclidemulator1, both at the level of power spectrum prediction and at the level of posterior probability distributions of the cosmological parameters, for different cosmological models and different galaxy power spectrum wavenumber cut-offs. We confirm that the choice of the power spectrum predictor has a non-negligible effect on the computed sensitivities when doing cosmological parameter forecasting, even for a conservative wavenumber cut-off of $0.2\, h\, {\rm Mpc}^{-1}$. We find that euclidemulator1 is on average up to 17 per cent more sensitive to the cosmological parameters than the other two codes, with the most significant improvements being for the Hubble parameter of up to 42 per cent and the equation of state of dark energy of up to 26 per cent, depending on the case. In addition, we point out that the choice of the power spectrum predictor contributes to the risk of computing a significantly biased mean cosmology when doing parameter estimations. For the four tested scenarios we find biases, averaged over the cosmological parameters, of between 0.5σ and 2σ (from below 1σ up to 6σ for individual parameters). This paper provides a proof of concept that this risk can be mitigated by taking a well-tailored theoretical uncertainty into account as this allows to reduce the bias by a factor of 2 to 5, depending on the case under consideration, while keeping posterior credibility contours small: the standard deviations are amplified by a factor of ≤1.4 in all cases.

Astronomy & Astrophysics↗

Subtask 2.6 – Optimization of Aerosol Mitigation Technology for Postcombustion CO 2 Capture

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion CO 2 capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery (EOR). The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the aerosols present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and aerosols provide nucleation sites where amine vapors can condense. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, aerosol components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to optimize aerosol mitigation technology for PCCC at a lignite-fired power plant. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on collection of aerosols at a low-rank coal-fired power station. Determine the impact of aerosols on the efficiency and degradation products of amine-based carbon capture systems fired with low-rank fuels. Work was conducted at Minnkota Power Cooperative’s (MPC’s) Milton R. Young (MRY) Station Unit 2 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. To gather initial data for sizing and specifying a WESP for this system, a temporary pilot-scale WESP was rented and installed on-site. Several different conditions were tested to examine the impact of flow rate, voltage, and current on WESP performance. The WESP was effective at removing large particulate (>200 nm) but caused an increase in fine particulate (<75 nm). Fine particulate material at the inlet and outlet of the WESP was collected, analyzed, and showed that crystalline sulfates carried over from the plant’s FGD unit were being converted to fine aerosols and SO 2 was being converted to SO 3 through the WESP. Additionally, the high moisture content of the flue gas stream at this sample location also contributed to an overall increase in aerosol mass under some of the test conditions. Using the results from the rented WESP, the project team installed a smaller-scale WESP upstream of the EERC’s slipstream CO 2 capture system. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then routed through the new WESP before passing to the CO 2 absorber columns. Fluor’s amine-based solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Aerosols and sulfur species were measured at multiple locations throughout the pilot-scale system. The inlet FGD and DCC removed much of the particulate matter and gaseous sulfur upstream of the WESP. With this configuration, the WESP achieved >95% particulate capture. The new WESP did not show any of the increases in SO 3 or other aerosol species that had been consistently observed with the larger-scale WESP installed immediately downstream of the plant’s full-scale FGD unit. Particulate samples captured and analyzed from the WESP inlet did not show any presence of crystalline sulfate materials, indicating that the pilot-scale FGD and DCC were efficient at reducing carryover from the plant’s full-scale FGD unit. A set of parametric tests were conducted on the new WESP to assess the impacts of flow rate, voltage, number of online WESP fields, and gas-phase sulfur content on aerosol and sulfur transformations. The results showed that the WESP performed similarly well at all sets of conditions. Sulfur and particulate matter exiting the WESP were further reduced through the absorber column as the amine-based solvent captured some of the residual contaminants. Solvent analysis showed that these species were slowly concentrating in the solvent over the duration of the test. When the WESP was taken offline and the sulfur slip through the FGD allowed to rise, the sulfate content in the solvent rose sharply, showing that the extra FGD and WESP were effective at reducing sulfate and cation uptake. This would be expected to extend amine-based solvent life by slowing the formation of heat-stable salts and other degradation products. This subtask was cofunded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission and MPC.

01 COAL, LIGNITE, AND PEAT↗

Adaptive Data-based Predictive Control for Short Take-off and Landing (STOL) Aircraft

Data-based Predictive Control is an emerging control method that stems from Model Predictive Control (MPC). MPC computes current control action based on a prediction of the system output a number of time steps into the future and is generally derived from a known model of the system. Data-based predictive control has the advantage of deriving predictive models and controller gains from input-output data. Thus, a controller can be designed from the outputs of complex simulation code or a physical system where no explicit model exists. If the output data happens to be corrupted by periodic disturbances, the designed controller will also have the built-in ability to reject these disturbances without the need to know them. When data-based predictive control is implemented online, it becomes a version of adaptive control. The characteristics of adaptive data-based predictive control are particularly appropriate for the control of nonlinear and time-varying systems, such as Short Take-off and Landing (STOL) aircraft. STOL is a capability of interest to NASA because conceptual Cruise Efficient Short Take-off and Landing (CESTOL) transport aircraft offer the ability to reduce congestion in the terminal area by utilizing existing shorter runways at airports, as well as to lower community noise by flying steep approach and climb-out patterns that reduce the noise footprint of the aircraft. In this study, adaptive data-based predictive control is implemented as an integrated flight-propulsion controller for the outer-loop control of a CESTOL-type aircraft. Results show that the controller successfully tracks velocity while attempting to maintain a constant flight path angle, using longitudinal command, thrust and flap setting as the control inputs.

Barlow, Jonathan Spencer↗

Dynamic Restoration Strategy for Distribution System Resilience Enhancement

In electric power distribution systems, distributed energy resources (DERs) can act as controllable power sources and support utility operators to minimize power outages after extreme weather events (e.g., hurricane, earthquake, wildfire) and thus help enhance the grid's resilience. Meanwhile, the influences of extreme events and the capabilities of DERs are dynamic and difficult to predict. Hence, the desired distribution system restoration strategy should be able to evolve according to real-time fault/dis-turbance information and the availability of DERs. In this paper, we propose a new dynamic restoration strategy for distribution systems to enhance system resilience against potential hazards. An efficient reconfiguration algorithm is developed to eliminate the use of integer variables to relieve the computational burden. Model predictive control is implemented to adjust the system topology and DER operation set points based on the updated fault information and DER forecasts. The effectiveness of the proposed restoration model in enhancing distribution system resilience is validated through an IEEE 123-bus test system. Simulation results also validate that the proposed restoration model can mitigate the occurrence of unexpected events and the fluctuations of DERs.

distributed energy resources (DERs)↗

Dynamic Distribution System Restoration Strategy for Resilience Enhancement: Preprint

In electric power distribution systems, distributed energy re-sources (DERs) can act as controllable power sources and support utility operators to minimize power outages after ex-treme weather events (e.g., hurricane, earthquake, wildfire) and thus help enhance the grid's resilience. Meanwhile, the influ-ences of extreme events and the capabilities of DERs are dy-namic and difficult to predict. Hence, the desired distribution system restoration strategy should be able to evolve according to real-time fault/disturbance information and the availabil-ity of DERs. In this paper, we propose a new dynamic distribu-tion system restoration strategy to enhance system resilience against potential hazards. An efficient reconfiguration algo-rithm is developed to eliminate the use of integer variables to relieve the computational burden. Model predictive control is implemented to adjust the system topology and DER opera-tion setpoints based on the updated fault information and DER forecasts. The effectiveness of the proposed restoration model in enhancing distribution system resilience is validated through an IEEE 123-bus test system. Simulation results also validate that the proposed restoration model can mitigate the occurrence of unexpected events and the fluctuations of DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performing k eff Validation of As-Loaded Criticality Safety Calculations Using UNF-ST&DARDS: Sensitivity Calculations

The general method for performing validation of as loaded criticality safety calculations using UNF ST&DARDS is presented in a paper by Clarity, which includes a description of the UNF-ST&DARDS system. Proof-of-principle analyses were performed in the summer of 2019 for MPC-32 dual purpose canisters (DPCs) containing pressurized water reactor (PWR) fuel assemblies. Summaries of these results are presented in this and a companion paper for this conference. The current paper describes the TSUNAMI-3D calculations performed to generate sensitivity data, and the companion paper discusses the selection of critical experiments applicable for validation of the 11 MPC-32 DPCs considered. The generation of sensitivity data for as-loaded spent nuclear fuel (SNF) DPCs is a challenge given the detailed model of the fuel compositions generated by UNF ST&DARDS. Each fuel assembly is modeled with its own irradiation history in 18 axial nodes, unless the fuel assembly is damaged and thus considered as fresh by design basis. This results in a set of 576 fuel compositions, each of which must be processed separately in a multigroup (MG) calculation. Therefore, a continuous-energy (CE) TSUNAMI-3D method was chosen to alleviate this challenge. Two CE TSUNAMI-3D methods are available in SCALE 6.2.3: the iterated fission probability (IFP) and contribution-linked eigenvalue sensitivity/uncertainty estimation via track-length importance characterization (CLUTCH). Since the IFP method is not feasible because of memory requirements associated with its implementation in SCALE, the CLUTCH method was selected for these calculations. CLUTCH has been implemented in SCALE in parallel, allowing long calculations to be performed in reasonable timeframes. The two primary user inputs necessary for CLUTCH calculations are the F*(r) mesh and the number of latent generations used in determining the F*(r) function. This F*(r) function is used as the importance function for fission chains originating in a given volume element (voxel), and it is calculated using the IFP method in the skipped generations. A large number of skipped generations is thus required to ensure accurate calculation of this importance function. In these calculations, 500 generations were used to calculate the F*(r) function. For more information regarding the calculation of F*(r), see Jones [4]. The remainder of this paper is focused on the selection of the F*(r) mesh and the number of latent generations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IoT-Based Comfort Control and Fault Diagnostics System for Energy-Efficient Homes

This project studies an Internet of Things (IoT)-based comfort control and fault diagnostics system (referred as iComfort in this report) for energy-efficient homes. The system delivers an occupant-comfort-oriented thermal environment adaptive to fault scenarios and achieves HVAC energy savings in a cost-effective and straightforward way. This smart iComfort home system consists of the following key features. 1) Cost-effectiveness and scalability of the entire hardware and software system: The system includes low-cost temperature, humidity, and airflow sensors, and a Raspberry Pi-based local hub that interfaces with the cloud and IoT-enabled devices. The cost is low, not only for sensors, but also the costs associated with sensor installation, system setup and commissioning, data communication and storage, and data analytics (e.g., the development of automated fault detection and diagnosis (AFDD), as well as adaptive control strategies that are both computationally efficient and practical to implement). 2) Energy performance and user satisfaction: The system delivers user satisfaction and energy savings. This includes a) ease of use, b) optimal occupant thermal comfort, and c) accurate system feedback (e.g., low false alarm of AFDD strategies). 3) Favorable demonstrated prototype performance: The prototype tested at the Pacific Northwest National Laboratory (PNNL) Lab Homes demonstrates the accuracy of fault detections and diagnoses and shows thermal comfort improvement and energy savings through adaptive and optimal HVAC operations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A guideline to document occupant behavior models for advanced building controls

The availability of computational power, and a wealth of data from sensors have boosted the development of model-based predictive control for smart and effective control of advanced buildings in the last decade. More recently occupant-behavior models have been developed for including people in the building control loops. However, while important objectives of scientific research are reproducibility and replicability of results, not all information is available from published documents. Therefore, the aim of this paper is to propose a guideline for a thorough and standardized occupant-behavior model documentation. For that purpose, the literature screening for the existing occupant behavior models in building control was conducted, and the occupant behavior modeling processes were studied to extract practices and gaps for each of the following phases: problem statement, data collection, and preprocessing, model development, model evaluation, and model implementation. Here, the literature screening pointed out that the current state-of-the-art on model documentation shows little unification, which poses a particular burden for the model application and replication in field studies. In addition to the standardized model documentation, this work presented a model-evaluation schema that enabled benchmarking of different models in field settings as well as the recommendations on how OB models are integrated with the building system.

Building control↗

Robust Predictive Control for Modular Solid-State Transformer With Reduced DC Link and Parameter Mismatch

This paper presents the analysis and implementation of a predictive control method for dc-link regulation and voltage balance in a cascaded modular reduced dc-link solid-state transformer (SST). Passive components like bulky dc links limit the power density of power converters, especially medium-voltage (MV) SST. Reduced dc-link or low-inertia converters can dramatically reduce the size, cost, and weight by tolerating larger dc-link ripples and improve the reliability with electrolytic capacitor-less dc link. However, a small dc link leads to tight coupling between the input and the output stages, which is a challenge for control design. In stacked low-inertia converters (SLIC), the low-inertia converter modules are stacked for MV applications, resulting in coupling between the modules and making the control more challenging. A new model predictive control method which can achieve deadbeat regulation on the dc link without weighting factors has been proposed to address this novel problem. This paper focuses on analyzing the condition of the low-inertia dc link up to 80% ripple, the robustness of the control under parameter mismatches, high-order terms, and important implementation issues such as model-based sampling and computation delay compensation. Significantly, the high-order terms are introduced because of the large dc-link ripple. These high-order terms are unique to the SLIC and negligible in conventional high-inertia converters. A discrete-time large-signal model is built to capture the dc-link’s nonlinear dynamics, and the eigenvalues of a small-signal Jacobian matrix are analyzed with Floquet theory to evaluate stability, using the modular soft-switching solid-state transformer (M-S4T) as an example of the SLIC. Simulation and experimental results of an MVDC M-S4T verify the analysis and the predictive control method. Finally, the general application of the predictive control to low-inertia converters is compared against a conventional PI controller using a reduced dc-link active-front-end (AFE) rectifier as an example.

14 SOLAR ENERGY↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗