CHM-MS-net-Canopy-Height-Model
The CHM-MS-net Canopy Height Model is a MS-net neural network applied to high resolution satellite imagery to estimate tree height, tree location, and crown radius.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
The CHM-MS-net Canopy Height Model is a MS-net neural network applied to high resolution satellite imagery to estimate tree height, tree location, and crown radius.
Creating controlled lipid unsaturation locations in oleochemicals can be a key to many bioengineered products. However, evaluating the effects of modifications to the acyl-ACP desaturase on lipid unsaturation is not currently amenable to high-throughput assays, limiting the scale of redesign efforts to <200 variants. Here, we report a rapid mass spectrometry (MS) assay for profiling the positions of double bonds on membrane lipids produced by Escherichia coli colonies after treatment with ozone gas. By MS measurement of the ozonolysis products of Δ6 and Δ8 isomers of membrane lipids from colonies expressing recombinant Thunbergia alata desaturase, we screened a randomly mutagenized library of the desaturase gene at 5 s per sample. Two variants with altered regiospecificity were isolated, indicated by an increase in 16:1 Δ8 proportion. We also demonstrated the ability of these desaturase variants to influence the membrane composition and fatty acid distribution of E. coli strains deficient in the native acyl-ACP desaturase gene, fabA. Finally, we used the fabA deficient chassis to concomitantly express a non-native acyl-ACP desaturase and a medium-chain thioesterase from Umbellularia californica, demonstrating production of only saturated free fatty acids.
The lithium/sulfur battery system provides the opportunity for high capacity and low-cost batteries, and addresses the several challenges facing this technology including the need for improved rate capability and capacity retention. The presence of both 2D MS 2 nanosheets and sulfur will provide several advantages to address the limitations, including enhanced conductivity to the inherently insulating sulfur by the inclusion of MS 2 nanosheets, as well as utilizing the nanosheets to entrap negatively charged polysulfide species to prevent polysulfide shuttling and extend cycle life meeting Battery500 Program goals.
The aim of this project is to develop methodology to identify and analyze U and Pu containing particles using laser ablation MC-ICP-MS. The final methodology will ultimately be described in a detailed procedural document that will be shared with IAEA-NWAL laboratories. In this report, we describe the Task-1 deliverable; the setup and optimization of hardware required to perform U isotopic analyses by laser ablation MC-ICP-MS.
This project will develop methodology to analyze the Pu isotope ratio in mixed U-Pu particles by laser ablation MC-ICP-MS. This will involve: 1) testing and validation of the Pu analytical method using mixed U-Pu solutions and Pu doped glasses, 2) isotopic analysis of mixed U-Pu particles by laser ablation MC-ICP-MS, and 3) continued development of the R-based data reduction program. Details regarding the analytical method development and results of QC testing will be output as a deliverable to the IAEA, along with an updated version of the LARA data reduction software.
Trace-level measurements of iodine’s isotopic ( 129 I and 127 I) and chemical species distributions are needed for an accurate understanding of radioiodine migration in the Hanford subsurface. Pacific Northwest National Laboratory (PNNL) previously developed a novel analytical method for iodine characterization that uses ion chromatography (IC) coupled to inductively coupled mass spectrometry (ICP-MS). While the method can measure speciated forms of 129 I at levels below the drinking water standard, an interference from molybdenum (Mo) prevents the assay from quantifying the $\underline{total}$ 129 I concentration in many Hanford sample matrices. In this work, solvent extraction was evaluated as a sample preparation method for eliminating the Mo interference. A series of 10 experiments was conducted in which solutions containing known amounts of iodate or iodide were treated by solvent extraction, and the extracted solutions were analyzed for total iodine concentrations by ICP MS. Several extraction parameters such as reagent concentrations and chemical reaction times were systematically adjusted in attempts to optimize the extraction process. While solvent extraction was shown to be effective at removing Mo, there was a consistent inability to recover more than approximately 75% of the total iodine in most experiments. This would reduce the ability to detect 129 I at levels near the drinking water standard. Additionally, the extraction efficiencies in several experiments were highly variable, suggesting that solvent extraction could add significant uncertainty to radioiodine measurements. We recommend evaluating ion exchange as an alternative sample preparation approach in fiscal year (FY) 2024.
Coal and coal-related fly ash often contain rare earth elements (REEs) that have the potential to be utilized as valuable mineral resources. Accurately determining the REE content in coal and fly ash is crucial for resource evaluation. The conventional approach involves using hydrofluoric acid (HF) to dissolve silicates and release REEs, which, however, prolongs the digestion process due to the additional step of complexing fluoride ions (F−) with boric acid (H3BO3). Determining the correct amount of H3BO3 for neutralization can be challenging, and in some instances, the binding of fluoride ions with certain lanthanides (Lns) hampers the accurate determination of all 14 naturally occurring rare earth elements in a single digestion batch by inductively coupled plasma mass spectrometry (ICP-MS). In this study, we present an alternative method that achieves the accurate determination of all 14 naturally occurring REEs using tetrafluoroboric acid (HBF4) followed by ICP-MS analysis. This approach eliminates the need for an F− complexing step. We tested this method on certified REE reference materials, including NIST 1632e (coal) and NIST 1633c (fly ash), as well as the REE geological reference material USGS AGV-1 (andesite). Our results demonstrated excellent recovery rates (relative standard deviation, RSD < ±10%), with a correlation coefficient (r2) exceeding 0.99. Using this method, we investigated the concentrations of all 14 REEs in coal and fly ash samples collected from various locations in the southwestern USA. This improved digestion technique streamlines the analysis process and enhances the accuracy of REE determination, facilitating a more comprehensive evaluation of REE-rich coal and fly ash deposits for resource exploration.
The enzyme enoyl-ACP reductase (also called FabI in bacteria) is an essential member of the fatty acid synthase II pathway in plants and bacteria. This enzyme is the target of the antibacterial drug triclosan and has been the subject of extensive studies for the past 20 years. Despite the large number of reports describing the biochemistry of this enzyme, there have been no studies that provided direct observation of the protein and its various ligands. In this paper we describe the use of native MS to characterize the protein–ligand interactions of FabI with its coenzymes NAD + and NADH and with the inhibitor triclosan. Measurements of the gas-phase affinities of the enzyme for these ligands yielded values that are in close agreement with solution-phase affinity measurements. Additionally, FabI is a homotetramer and we were able to measure the affinity of each subunit for each coenzyme, which revealed that both coenzymes exhibit a positive homotropic allosteric effect. An allosteric effect was also observed in association with the inhibitor triclosan. These observations provide new insights into this well-studied enzyme and suggest that there may still be gaps in the existing mechanistic models that explain FabI inhibition.
We report the performance of LSC cocktails in ultra-sensitive applications was evaluated. Backgrounds from radioactive contaminations in commercially available and in-house developed liquid scintillation cocktails were measured and compared to the predicted background levels of the ultra-low background liquid scintillation counter. Through the ICP-MS assay of the cocktails and their constituents, potassium impurities in the surfactant component were identified as a significant source of background, potentially limiting the use of LSC counting in ultra-sensitive applications. This work lays the groundwork for future research towards ultrapure LSC cocktails for ultrasensitive LSC counting
Despite their prohibition by the Chemical Weapons Convention, nerve agents (NAs) remain in use against military and civilian targets. Due to their high reactivity, NAs readily degrade to phosphonic acids, making them important markers in the inspection of areas of presumed NA use. In this work, we assess the use of benzylation to modify ethyl- and pinacolyl methylphosphonic acids, degradation products of VX and Soman respectively, for their efficient detection in a soil matrix at ~10 and ~1 μg/g using GC–MS. The soil matrix, Sandy Loam (SL), was chosen for its ubiquitous nature, complex composition with silica particles embedded in clay, and low organic content. In this study, we demonstrate that benzylation via benzyl bromide yields a LOD = 25.6 ng/mL for benzylated-EMPA and LOD = 30.1 ng/mL for benzylated-PMPA. This is superior to the use of p-methoxybenzyl trichloroacetimidate in providing stable phosphonic acid ester derivatives for analysis. A base-modified procedure for p-methoxybenzylation was explored in this study yielding a LOD = 29.1 ng/mL for p-methoxybenzylated-EMPA and LOD = 39.8 ng/mL for p-methoxybenzylated-PMPA. Both benzylation pathways (benzyl bromide and p-methoxybenzyl trichloroacetimidate) can be used to yield phosphonic acid derivatives that provide further confirmation of these Soman and VX degradation products in soil samples in investigative scenarios. The work herein represents the first application of benzylation methods for the analysis of these NA markers in the acidic, silicon-based SL soil.
In this study we utilize an all-faraday cup detector configuration on the Neoma MC-ICP-MS to perform uranium isotope ratio determinations from certified reference materials and a nuclear fuel precursor material via solution and laser ablation based sampling methodologies. The goal in performing these measurements is primarily to demonstrate that the all-faraday cup method can produce highly precise and accurate isotope ratios even at relatively low signal intensity levels while also developing a preliminary understanding of how the complex interplay between different amplifier resistor levels (e.g. 10 11 vs 10 13 Ω) and integration times impacts the precision and accuracy of different types of measurements. Our results show that the faraday cups with 1013 Ω resistors in their amplifier feedback loops can be used to produce accurate and relatively precise isotope ratios for ion beams down to ~5 K cps. However, at the lower end of the signal intensities observed in this study, longer integration times are necessary to mitigate the impact of ion beam instability that can occur during laser ablation based sampling. Despite this potential limitation, the all-faraday cup method is highly versatile as exemplified by the analysis of a collection of uranium reference materials with highly variable uranium isotopic compositions.
Dust particulate fallout on materials in use for rare-event searches is a concerning source of radioactive backgrounds due to the presence of the naturally occurring radionuclides 40 K, 232 Th, 238 U, and their progeny in dust. Much effort is dedicated to inform radioactive backgrounds from dust and evaluate the efficacy of mitigation procedures. A great portion of such effort relies on fallout models and assumed dust composition. Here, in this work, an ICP-MS based methodology was employed for a direct determination of fallout rates of radionuclides and stable isotopes of interest from dust particulate at the SNOLAB facility. Hosted in an active mine, the SNOLAB underground laboratory strives to maintain experimental areas at class 2000 cleanroom level. This work validates the mitigation procedures in place at SNOLAB and informs dust backgrounds during laboratory activities. Fallout rates of major constituents of the local rock were measured two to three orders of magnitude lower in the clean experimental areas compared to non-clean transition areas from the mine to the laboratory. An increase of approximately two orders of magnitude in the fallout rate of stable Pb isotopes was determined in an experimental area during activities involving handling of Pb bricks. Increased 40 K, 232 Th, and 238 U fallout rates were measured in clean experimental areas during activities generating particulate.
Environmental exposure to crude oil through seepage and spillage poses risks to the immediate environment and the broader ecosystem as areas along the oil distribution path are affected by the influx of crude petroleum as well as the environmental, economic, and civil unrest that accompanies it. There is a large financial burden associated with the lost resources, including the cost of rehabilitation, and the affected sources of revenue for communities affected by oil spills. As such, it is crucial to determine the responsible parties. This work outlines an environmental forensics approach to determining the source of an un-weathered crude oil sample. The researchers employed solid phase microextraction coupled with gas chromatography mass spectrometry (SPME-GC-MS) to capture and analyze the gaseous components emitted by crude oil samples sourced from five locations. Samples were analyzed using Spearman's rank correlation and 3D covariance analysis. Both chemometric approaches yielded optimal performance results with no misclassifications, true positive rate (TPR) = 100 % and false positive rate (FPR) = 0 %. The similarity metrics calculated by each test noted clear delineations between the values of same-source and differently sourced samples. The Spearman's rank correlation test and 3D covariance calculations both demonstrated the ability to correctly identify sample source origin in this dataset. Finally, the authors outline an approach to the future application of these tests and suggest their joint use in future crude oil sourcing endeavors.
As metabolomics grows into a high-throughput and high demand research field, current metrics for the identification of small molecules in gas chromatography–mass spectrometry (GC–MS) still require manual verification. Though steps have been taken to improve scoring metrics by combining spectral similarity (SS) and retention index (RI), the problem persists. A large body of literature has analyzed and refined SS scores, but few studies have explicitly studied improvements to RI scores. Here, in this study, we examined whether uninvestigated assumptions of the RI score are valid and propose ways to improve them. Query RIs were matched to library RI with a generous window of ±35 to avoid unintentional removal of valid compound identifications. Each match was manually verified as a true positive (TP), true negative, or unknown. Metabolites with at least 30 TP identifications were included in downstream analyses, resulting in a total of 87 metabolites from samples of varying complexity and type (e.g., amino acid mixtures, human urine, fungal species, and so on.). Our results showed that the RI score assumptions of normality, consistent variance across metabolites, and a mean error centered at 0 are often violated. We demonstrated through a cross-validation analysis that modifying these underlying assumptions according to empirical metabolite-specific distributions improved the TP and negative rankings. Further, we statistically determined the minimum number of samples required to estimate distributional parameters for scoring metrics. Overall, this work proposes a robust statistical pipeline to reduce the time bottleneck of metabolite identification by improving RI scores and thus minimize the effort to complete manual verification.
Subtle variations in stable isotope ratios at natural abundance are challenging to measure but can yield critical insights into biological, physical, and geochemical processes. Well established methods, particularly multi-collector, gas-source or plasma isotope ratio mass spectrometry (IRMS) are the gold standard for stable isotope measurement but inherent limitations in these approaches make them ill-suited to determining site-specific and multiply substituted isotopic abundances of all but a few compounds, or to characterizing mixtures or larger intact molecules. Additionally, Fourier transform mass spectrometry (FTMS), namely Orbitrap mass spectrometry, has recently demonstrated the ability to measure natural abundance isotope ratios with chemically informative accuracy and precision. Here, we report the first use of Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) for the accurate (<1‰) and precise (<1‰ standard error) simultaneous determination of $δ$ 13 C and $δ$ 15 N in caffeine isotopologues and provide a discussion of the critical instrumental parameters necessary to make such measurements. Finally, we report the ability to make these measurements with online liquid chromatography, expanding the ability of this technique to explore mixtures in the future.
The analysis by EI-GC-MS of 3-quinuclidinol (3Q), a marker for the riot control and incapacitating agent quinuclinidyl benzilate (BZ), using several, new acylation strategies is described. After evaluating and optimizing conditions for the acylations, these were tested on their ability to successfully derivatize 3Q in three different matrices featured in the 44th Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency test (PT). As 3Q is a highly polar compound, the work here describes acylation strategies that generate 3Q analogs with superior gas chromatographic profiles relative to the underivatized material. The acyl groups studied in this work included acetyl, benzoyl, pentafluorobenzoyl and the bis(3,5-trifluoromethyl)benzoyl. The acylated 3Q products provide sharp, detectable peaks with significantly different retention times from that of the unmodified 3Q. Thus, the retention times for acetyl-, benzoyl-, pentafluorobenzoyl- and 3,5-bis(trifluoromethyl)benzoyl-3Q were determined to be 15.9, 24.9, 22.8 and 22.1 min respectively, in stark contrast to the unmodified 3Q which provides a sharp peak with a retention time centered at ~ 13.5 min only at high concentrations (> 10 µg/mL or µg/g) while a broad peak (RT ~ 15–15.5 min) at low concentrations (< 5 µg/mL or µg/g). The developed protocol was used to derivatize 3Q in three separate matrices. The first two matrices were liquid samples featured during the 44th OPCW PT at two separate concentrations in each (5 and 50 µg/mL). The last matrix was a soil sample featured in the same 44th OPCW PT wherein the 3Q had been spiked at a 12 µg/g concentration. The approach involves the extraction of 3Q from all matrices followed by its acylation resulting in a second reportable analytical method for an OPCW PT. The presented derivatization strategies should find wide applicability particularly in laboratories involved with the analysis of this chemical weapon agent degradation product and those participating in the yearly OPCW PTs.
This work describes an analytical procedure, single particle-inductively coupled plasma-time-of-flight-mass spectrometry (SP-ICP-TOF-MS), that was developed to determine the platinum binding efficiency of protein-coated magnetic microparticles.
A sample introduction technique was developed to allow for online, dropwise injection of effluent into a mass spectrometer (MS). This allowed for the coupling of chromatography systems that were not driven by pumps without altering the set-up or separation performance. This capability combined the benefits of coupling separation and measurement while also enabling accurate chromatographic evaluation that would generally be performed offline. The incorporation of a flowing rinse into the system made dropwise resolution possible for any liquid capable of forming drops under ambient conditions. The technique was demonstrated utilizing gas pressurized extraction chromatography (GPEC) and inductively coupled plasma-time-of-flight mass spectrometry (ICP-TOFMS) to illustrate the qualitative applications for rapid separation development and procedure evaluation. This method's quantitative applications were evaluated using single and double isotope dilution mass spectrometry (IDMS) with an external mass bias correction to measure analytes across entire elutions including volumes as small as single drops. In conclusion, the total neodymium values afforded by both single and double IDMS were within the uncertainty of the calculated value for evaluation of full elution peaks and for most of the single drops analyzed that reached above 10k cps Nd-144.