Search NASA⌕ Search

SEARCH · Search NASA

Results for “MYLAR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Testing of flat conductor cable to Underwriters Laboratory standards UL719 and UL83

The flat conductor cable (FCC) which was tested consisted of three AWG No. 12 flat copper conductors laminated between two films of polyethylene terephthalate (Mylar) insulation with a self-extinguishing polyester adhesive. Results of the tests conducted on this cable, according to specifications, warrants the use of this FCC for electrical interconnections in a surface nonmetallic protective covering.

Loggins, R. W.↗

Status of the NASA-Lewis flat-plate collector tests with a solar simulator

Simulator test results of 15 collector types are presented. Collectors are given performance ratings according to their use for pool heating, hot water, absorption A/C or heating, and solar Rankine machines. Collectors found to be good performers in the above categories, except for pool heating, were a black nickel coated, 2 glass collector, and a black paint 2 glass collector containing a mylar honeycomb. For pool heating, a black paint, one glass collector was found to be the best performer. Collector performance parameters of 5 collector types were determined to aid in explaining the factors that govern performance. The two factors that had the greatest effect on collector performance were the collector heat loss and the coating absorptivity.

Simon, F. F.↗

Investigation of land-use spectral signatures

A technique was developed to obtain bidirectional reflectance data from natural surfaces by using a folding mirror to transfer the reflected energy from the test surface to a spectroradiometer. The folding mirror was a first surface reflector made by stretching Mylar vacuum coated with aluminum over a light weight frame. The optically folding mirror was positioned over the test surfaces with a moveable platform for both laboratory and field tests. Field tests were conducted using a tethered balloon system to position the folding mirror. A spectroradiometer was designed and built specifically for this investigation. The spectroradiometer had an angular field of view of twenty-four minutes in one axis and ten minutes in the other axis. The radiometer was capable of detecting energies in small bandwidths throughout the electromagnetic spectrum from 0.3 microns to 3.0 microns. Bidirectional reflectance data and variations in the data with source angles were obtained for Saint Augustine grass, Bermuda grass, and a black alluvium soil from the Mississippi River delta.

Hagewood, J. F.↗

Transition radiations in X-ray region

The theory of production of radiations in the transoptical region by the passage of high energy charged particles through the interface of two media is discussed. Based on the theoretical model, calculations are made for electrons of selected energy range passing through Mylar.

George, M. C.↗

Status of the NASA-Lewis flat-plate collector tests with a solar simulator

Simulator test results of 15 collector types are reported. Collectors are given performance ratings according to their use for pool heating, hot water, absorption A/C or heating and solar Rankine machines. Collectors found to be good performers in the above categories, except for pool heating, were a black nickel coated, 2 glass collector, and a black paint 2 glass collector containing a mylar honeycomb. For pool heating, a black paint, one glass collector was found to be the best performer. Collector performance parameters of 5 collector types were determined to aid in explaining the factors that govern performance. The two factors that had the greatest effect on collector performance were the collector heat loss and the coating absorptivity.

Simon, F. F.↗

Compliant wall-turbulent skin-friction reduction research

Previous compliant-wall experiments successful in reducing skin-friction drag probably have had a (unplanned) membrane resonance at a favorable frequency, amplitude, wave shape, length, and speed. The most probable drag reduction mechanism involves a direct coupling between the fluid and the moving wall when the wall natural resonance frequencies are near the fundamental turbulent burst frequency. Local skin-friction reductions of 61% were measured with mylar/PVC plastisol compliant surfaces. These reductions were observed only at certain flow conditions, indicating that changing tunnel total temperature may have altered the substrate dynamic modulus, damping, and coupled mylar tension. Apparently, the coupled membrane/substrate must be excited in compatible narrow-band natural frequency modes. An accelerated effort is required to develop practical durable compliant surfaces optimized for maximum drag reduction. Application of compliant walls to other transportation modes appears feasible with liquid flows offering the greatest skin-friction drag reduction potential.

Fischer, M. C.↗

High-resolution system for tropospheric wind and temperature profile measurements

This paper briefly describes the Jimsphere/Jimsonde system and presents some possible applications of the system. As space vehicles became larger and more sophisticated, an improved method for obtaining wind-profile data had to be found. To satisfy this need, the FPS-16 radar/Jimsphere system was developed. The Jimsphere is an aluminized mylar spherical balloon 2 m in diameter. The balloon is under superpressure and is tracked with a high-precision radar system. The development of this detailed wind-profile system was started in 1963, and the present design was established in 1964. To improve the system, a program was initiated in 1965 to obtain high-resolution temperature data simultaneously with the wind-profile data.

Camp, D. W.↗

Uniform solar cells

Solar cells used in radiation sensors can be efficiently matched by individual trimming. Strip of aluminized Mylar is used to adjust cell output to within required tolerances. Method is faster than individual selection of matched cells.

Source record↗

Testing flat-conductor cable

Report describes characteristics of type of FCC which consists of three AWG No. 12 flat copper conductors laminated between two films of polyethylene terephthalate (Mylar) insulation with self-extinguishing polyester adhesive.

Loggins, R. W.↗

Improved insulation material

Multilayer material consisting of embossed, silver-coated Mylar, nylon net, and silk net is useful for thermal-protection systems and cryogenic containers. Embossing serves two purposes: helps separate radiation barriers and controls radiant energy diffusion. Insulation requires no maintenance after installation.

Source record↗

External heater for cryogenic vessels

When used in conjunction with nitrogen purge system, external heating film increases gas temperature, thereby preventing chilling of equipment. Proposed system includes vacuum-deposited layer of gold sandwiched between two layers of Mylar, which act as carrier for film and prevent damage.

Wennagel, G. J.↗

Dewar technology study

The development of a Dewar system for handling liquid helium under weightless conditions is described. Porous plug designs for the prevention of superfluid creep out of the dewar through the vent line were evaluated. For the purpose of designing a neck to provide a transition from the cold cavity to the outside, the loads carried by the neck and equipment supports were studied. Temperature, pressure, and mass flow instrumentation for monitoring Dewar performance were also evaluated. In addition, multilayer blankets consisting of aluminized Mylar separated by Dacron net sheets were designed to insulate the pressure vessel. The dewar system is suggested for use with the star tracking telescope aboard the relativity satellite.

Davis, W.↗

Purging of multilayer insulation by gas diffusion

An experimental investigation was conducted to determine the time required to purge a multilayer insulation (MLI) panel with gaseous helium by means of gas diffusion to obtain a condensable (nitrogen) gas concentration of less than 1 percent within the panel. Two flat, rectangular MLI panel configurations, one incorporating a butt joint, were tested. The insulation panels consisted of 15 double-aluminized Mylar radiation shields separated by double silk net spacers. The test results indicated that the rate which the condensable gas concentration at the edge or at the butt joint of an MLI panel was reduced was a significant factor in the total time required to reduce the condensable gas concentration within the panel to less than 1 percent. The experimental data agreed well with analytical predictions made by using a simple, one-dimensional gas diffusion model in which the boundary conditions at the edge of the MLI panel were time dependent.

Sumner, I. E.↗

Thermal performance of a customized multilayer insulation (MLI)

The thermal performance of a LH2 tank on a shroudless vehicle was investigated. The 1.52 m (60 in) tank was insulated with 2 MLI blankets consisting of 18 double aluminized Mylar radiation shields and 19 silk net spacers. The temperature of outer space was simulated by using a cryoshroud which was maintained at near liquid hydrogen temperature. The heating effects of a payload were simulated by utilizing a thermal payload simulator (TPS) viewing the tank. The test program consisted of three major test categories: (1) null testing, (2) thermal performance testing of the tank installed MLI system, and (3) thermal testing of a customized MLI configuration. TPS surface temperatures during the null test were maintained at near hydrogen temperature and during test categories 2 and 3 at 289 K (520R). The heat flow rate through the tank installed MLI at a tank/TPS spacing of 0.457 m was 1.204 watts with no MLI on the TPS and 0.059 watts through the customized MLI with three blankets on the TPS. Reducing the tank/TPS spacing from 0.457 m to 0.152 m the heat flow through the customized MLI increased by 10 percent.

Leonhard, K. E.↗

Degradation of a Multilayer Insulation Due to a Seam and a Penetration

The degradation of the thermal performance of a multilayer insulation due to the presence of a seam and a penetration was studied. The multilayer insulation had 30 aluminized Mylar radiation shields with silk net spacers. The seam, an offset butt joint, caused a heat input of 0.169 watt per meter in addition to the basic insulation thermal performance of 0.388 watt per square meter obtained before the installation of the butt joint. The penetration, a fiberglass tank support strut, provided a heat input (including the degradation of the insulation) of 0.543 watt in addition to the basic insulation thermal performance of 0.452 watt per square meter obtained before the penetration.

Sumner, I. E.↗

Magellan - A balloon-borne collection technique for large cosmic dust particles

The paper describes a balloon-borne system for collecting large (50 to a few hundred micrometers in the major dimension) solid particles falling through the atmosphere at an altitude of about 30 km which are postulated to be fragments of larger cosmic particles or bodies which disintegrate on entering the atmosphere. The major component of the system is the collection surface - a funnel, 7.2 m in diameter, fabricated from mylar, 12 microns thick, and lightly coated with aluminum. Also described is the sample collector, which collects the particles gathered in the apex of the cone. Two successful flights of short duration using zero-pressure balloons have been achieved. Some examples of particles collected are shown. Mg, Al, Si, S, K, Ca, Ti, and Fe have been detected in these particles by energy dispersive X-ray analysis.

Wlochowicz, R.↗

Purging of a multilayer insulation with dacron tuft spacer by gas diffusion

The time and purge gas usage required to purge a multilayer insulation (MLI) panel with gaseous helium by means of gas diffusion to obtain a condensable gas (nitrogen) concentration of less than 1 percent within the panel are stipulated. Two different, flat, rectangular MLI panels, one incorporating a butt joint, were constructed of of 11 double-aluminized Mylar (DAM) radiation shields separated by Dacron tuft spacers. The DAM/Dacron tuft concept is known commercially as Superfloc. The nitrogen gas concentration as a function of time within the MLI panel could be adequately predicted by using a simple, one dimensional gas diffusion model in which the boundary conditions at the edge of the MLI panel were time dependent. The time and purge gas usage required to achieve 1 percent nitrogen gas concentration within the MLI panel varied from 208 to 86 minutes and 34.1 to 56.5 MLI panel purge volumes, respectively, for gaseous helium purge rates from 10 to 40 MLI panel volumes per hour.

Sumner, I. E.↗

Thermal performance of a modularized replaceable multilayer insulation system for a cryogenic stage

A rugged modularized MLI system for a 2.23-meter-diameter (87.6-in.-diam) liquid hydrogen tank was designed, fabricated, and tested under simulated near-earth and deep-space environments. The two blankets of the system were each composed of 17 double-aluminized Mylar radiation shields separated by silk net. The unit area weight of the installed system was 1.54 kg/sqm (0.32 lb/sq ft). The overall average heat transferred into the insulated tank was 22.7 and 0.98 watts (77.4 and 3.3 Btu/hr) during simulated near-earth and deep-space testing, respectively. The near-earth result was only 2.6 times that predicted for an undisturbed insulation system (i.e., no seams or penetrations). Tests indicate that this insulation concept could be useful for a cryogenic space tug or orbit transfer vehicle application.

Knoll, R. H.↗