Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mach 1.7”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Background Oriented Schlieren Applied to Study Shock Spacing in a Screeching Circular Jet

Background oriented schlieren (BOS) is a recent development of the schlieren and shadowgraph methods. The BOS technique has the ability to provide visualizations of the density gradient in both the axial and radial directions. The resultant magnitude of the density gradients allows for comparison with shadowgraph images. This paper first compares data obtained by the BOS and shadowgraph techniques at identical conditions in a free jet. The patterns and spacing of the shock trains obtained by the two techniques are found to be consistent with one another. This provides confidence in the shock spacing measurement by the BOS technique. Due to its simpler setup, BOS is then applied to investigate the shock spacing associated with the screech phenomenon, especially during stage jumps. Screech frequencies from a 37.6 mm convergent nozzle, as a function of jet Mach number (M(sub j)), are shown to exhibit various stages. As many as eight stages are identified with the present nozzle over the range 1.0 < M(sub j) <1.7. BOS images are acquired at various screech conditions and the shock spacing is examined as a function of M(sub j).

Clem, Michelle M.↗

Effect of wing sweep, angle of attack, Reynolds number, and wing root fillet on the interference heating to the wing windward surface of an entry vehicle configuration

The phase-change-coating technique was used to study the interference heating to the windward surface of 14 deg, 25 deg, and 50 deg swept wings of an entry vehicle configuration. One wing root of each model was faired to the fuselage with a fillet. Tests were made at Mach 8 at angles of attack of 0 deg, 20 deg, 40 deg, and 60 deg and at free-stream Reynolds numbers based on model length of 0.47 and 1.7 million. Bow shock impingement heating was found to increase in magnitude and affected area with increasing angle of attack until at a higher angle of attack it decreases; this angle of attack is lower for a 50 deg swept wing. Wing root interference heating was found to increase with angle of attack up to 40 deg and then to remain approximately constant. Consequently, wing root interference heating becomes the major type of interference heating at large angles of attack, and this occurs at a lower angle of attack for the highest sweep angle. A wing leading-edge root fillet reduces the peak in wing root interference heating near the leading edge, and increasing Reynolds number increases the level of interference heating.

Clark, L. E.↗

Return stroke velocities and currents using a solid state silicon detector system

A small, portable device has been developed to measure return stroke velocities. With the device, velocities from 135 strokes that consist of 92 natural return strokes and 43 triggered return strokes have been analyzed. The average return stroke velocity for longer channels, greater than 500 meters, is 1.2 + or - 0.3 x 10 to the 8th m/s for both natural and triggered return strokes. For shorter channel lengths, less than 500 m, natural lightning has a statistically higher average return stroke velocity of 1.9 + or - 0.7 x 10 to the 8th m/s than triggered lightning with an average return stroke velocity of 1.4 + or - 0.4 x 10 to the 8th m/s. Using the transmission line model of the return stroke, natural lightning has a peak current distribution that is log-normal with a median value of 19 kA. Return stroke velocities and currents were determined for two distant single stroke natural positive cloud-to-ground flashes. The velocities were 1.0 and 1.7 x 10 to the 8th ms/s while the estimated peak current for each positive flash was over 125 kA.

Mach, Douglas M.↗

Direct-detection Free-space Laser Transceiver Test-bed

NASA Goddard Space Flight Center is developing a direct-detection free-space laser communications transceiver test bed. The laser transmitter is a master-oscillator power amplifier (MOPA) configuration using a 1060 nm wavelength laser-diode with a two-stage multi-watt Ytterbium fiber amplifier. Dual Mach-Zehnder electro-optic modulators provide an extinction ratio greater than 40 dB. The MOPA design delivered 10-W average power with low-duty-cycle PPM waveforms and achieved 1.7 kW peak power. We use pulse-position modulation format with a pseudo-noise code header to assist clock recovery and frame boundary identification. We are examining the use of low-density-parity-check (LDPC) codes for forward error correction. Our receiver uses an InGaAsP 1 mm diameter photocathode hybrid photomultiplier tube (HPMT) cooled with a thermo-electric cooler. The HPMT has 25% single-photon detection efficiency at 1064 nm wavelength with a dark count rate of 60,000/s at -22 degrees Celsius and a single-photon impulse response of 0.9 ns. We report on progress toward demonstrating a combined laser communications and ranging field experiment.

Krainak, Michael A.↗

Aerodynamic Loads on an External Store Adjacent to a 45 Degree Sweptback Wing at Mach Numbers from 0.70 to 1.96, Including an Evaluation of Techniques Used

Aerodynamic forces and moments have been obtained in the Langley 9- by 12-inch blowdown tunnel on an external store and on a 45 degree swept-back wing-body combination measured separately at Mach numbers from 0.70 to 1.96. The wing was cantilevered and had an aspect ratio of 4.0; the store was independently sting-mounted and had a Douglas Aircraft Co. (DAC) store shape. The angle of attack range was from -3 degrees to 12 degrees and the Reynolds number (based on wing mean aerodynamic chord) varied from 1.2 x10(6) to 1.7 x 10(6). Wing-body transonic forces and moments have been compared with data of a geometrically similar full-scale model tested in the Langley 16-foot and 8-foot transonic tunnels in order to aid in the evaluation of transonic-tunnel interference. The principal effect of the store, for the position tested, was that of delaying the wing-fuselage pitch-up tendency to higher angles of attack at Mach numbers from 0.70 to 0.90 in a manner similar to that of a wing chord extension. The most critical loading condition on the store was that due to side force, not only because the loads were of large magnitude but also because they were in the direction of least structural strength of the supporting pylon. These side loads were greatest at high angles of attack in the supersonic speed range. Removal of the supporting pylon (or increasing the gap between the store and wing) reduced the values of the variation of side-force coefficientwith angle of attack by about 50 percent at all test Mach numbers, indicating that important reductions in store side force may be realized by proper design or location of the necessary supporting pylon. A change of the store skew angle (nose inboard) was found to relieve the excessive store side loads throughout the Mach number range. It was also determined that the relative position of the fuselage nose to the store can appreciably affect the store side forces at supersonic speeds.

Guy, Lawrence D↗

Wind tunnel tests of modified cross, hemisflo, and disk-gap-band parachutes with emphasis in the transonic range

Transonic wind-tunnel studies were conducted with modified cross, hemisflo, and disk-gap-band parachute models in the wake of a cone-cylinder shape forebody. The basic cross design was modified with the addition of a circumferential constraining band at the lower edge of the canopy panels. The tests covered a Mach number range of 0.3 to 1.2 and a dynamic pressure range from 479 Newtons per square meter to 5746 Newtons per square meter. The parachute models were flexible textile-type structures and were tethered to a rigid forebody with a single flexible riser. Different size models of the modified cross and disk-gap-band canopies were tested to evaluate scale effects. Model reference diameters were 0.30, 0.61, and 1.07 meters (1.0, 2.0, and 3.5 ft) for the modified cross; and nominal diameters of 0.25 and 0.52 meter (0.83 and 1.7 ft) for the disk-gap-band; and 0.55 meter (1.8 ft) for the hemisflo. Reefing information is presented for the 0.61-meter-diameter cross and the 0.52-meter-diameter disk-gap-band. Results are presented in the form of the variation of steady-state average drag coefficient with Mach number. General stability characteristics of each parachute are discussed. Included are comments on canopy coning, spinning, and fluttering motions.

Foughner, J. T., Jr.↗

Recombination of Hydrogen-Air Combustion Products in an Exhaust Nozzle

Thrust losses due to the inability of dissociated combustion gases to recombine in exhaust nozzles are of primary interest for evaluating the performance of hypersonic ramjets. Some results for the expansion of hydrogen-air combustion products are described. Combustion air was preheated up to 33000 R to simulate high-Mach-number flight conditions. Static-temperature measurements using the line reversal method and wall static pressures were used to indicate the state of the gas during expansion. Results indicated substantial departure from the shifting equilibrium curve beginning slightly downstream of the nozzle throat at stagnation pressures of 1.7 and 3.6 atmospheres. The results are compared with an approximate method for determining a freezing point using an overall rate equation for the oxidation of hydrogen.

Lezberg, Erwin A.↗

Closed cycle MHD power generation experiments using a helium-cesium working fluid in the NASA Lewis Facility

The MHD channel in the NASA Lewis Research Center was redesigned and used in closed cycle power generation experiments with a helium-cesium working fluid. The cross sectional dimensions of the channel were reduced to 5 by 16.5 cm to allow operation over a variety of conditions. Experiments have been run at temperatures of 1900-2100 K and Mach numbers from 0.3 to 0.55 in argon and 0.2 in helium. Improvements in Hall voltage isolation and seed vaporization techniques have resulted in significant improvements in performance. Typical values obtained with helium are Faraday open circuit voltage 141 V (92% of uBh) at a magnetic field strength of 1.7 T, power outputs of 2.2 kw for tests with 28 electrodes and 2.1 kw for tests with 17 electrodes. Power densities of 0.6 MW/cu m and Hall fields of about 1100 V/m were obtained in the tests with 17 electrodes, representing a factor of 18 improvement over previously reported results. The V-I curves and current distribution data indicate that while near ideal equilibrium performance is obtained under some conditions, no nonequilibrium power has been generated to date.

Sovie, R. J.↗

Comparison of continuum and particle simulations of expanding rarefied flows

Comparisons of Navier-Stokes solutions and particle simulations for a simple two-dimensional model problem at a succession of altitudes are performed in order to assess the importance of rarefaction effects on the base flow region. In addition, an attempt is made to include 'Burnett-type' extensions to the Navier-Stokes constitutive relations. The model geometry consists of a simple blunted wedge with a 0.425 meter nose radius, a 70 deg cone half angle, a 1.7 meter base length, and a rounded shoulder. The working gas is monatomic with a molecular weight and viscosity similar to air and was chosen to focus the study on the continuum and particle methodologies rather than the implementation of thermo-chemical modeling. Three cases are investigated, all at Mach 29, with densities corresponding to altitudes of 92 km, 99 km, and 105 km. At the lowest altitude, Navier-Stokes solutions agree well with particle simulations. At the higher altitudes, the Navier-Stokes equations become less accurate. In particular, the Navier-Stokes equations and particle method predict substantially different flow turning angle in the wake near the after body. Attempts to achieve steady continuum solutions including 'Burnett-type' terms failed. Further research is required to determine whether the boundary conditions, the equations themselves, or other unknown causes led to this failure.

Lumpkin, Forrest E., III↗

Time histories of horizontal-tail loads, elevator loads, and deformations on a jet-powered bomber airplane during abrupt pitching maneuvers at approximately 20,000 feet

Time histories are presented of horizontal-tail loads, elevator loads, and deformations on a jet-powered bomber during abrupt pitching maneuvers at a pressure altitude of approximately 20,000 feet. The normal and pitching accelerations measured varied from -0.90b to 3.41g and from -0.73 to 0.80 radian per second per second (sic), respectively, with a Mach number variation of from 0.40 to o.75. The maximum horizontal-tail load measured was 17,250 pounds down. The maximum elevator load was 1900 pounds up. The stabilizer twisted a maximum of 0.76 degrees leading edge down at the tip. The greatest fuselage deflection at the tail was about 1.7 inches down.

Wiener, Bernard↗

Acoustical evaluation of the NASA Lewis 9 by 15 foot low speed wind tunnel

The test section of the NASA Lewis 9- by 15-Foot Low Speed Wind Tunnel was acoustically treated to allow the measurement of acoustic sources located within the tunnel test section under simulated free field conditions. The treatment was designed for high sound absorption at frequencies above 250 Hz and to withstand tunnel airflow velocities up to 0.2 Mach. Evaluation tests with no tunnel airflow were conducted in the test section to assess the performance of the installed treatment. This performance would not be significantly affected by low speed airflow. Time delay spectrometry tests showed that interference ripples in the incident signal resulting from reflections occurring within the test section average from 1.7 dB to 3.2 dB wide over a 500 to 5150 Hz frequency range. Late reflections, from upstream and downstream of the test section, were found to be insignificant at the microphone measuring points. For acoustic sources with low directivity characteristics, decay with distance measurements in the test section showed that incident free field behavior can be measured on average with an accuracy of +/- 1.5 dB or better at source frequencies from 400 Hz to 10 kHz. The free field variations are typically much smaller with an omnidirectional source.

Dahl, Milo D.↗

Results of closed cycle MHD power generation test with a helium-cesium working fluid

The cross sectional dimensions of the MHD channel in the NASA Lewis closed loop facility were reduced to 3.8 x 11.4 cm. Tests were run in this channel using a helium-cesium working fluid at stagnation pressures of 160,000 n/M2, stagnation temperatures of 2000-2060 K and an entrance Mach number of 0.36. In these tests Faraday open circuit voltages of 200 V were measured which correspond to a Faraday field of 1750 V/M. Power generation tests were run for different groups of electrode configurations and channel lengths. Hall fields up to 1450 V/M were generated. Power extraction per electrode of 183 W and power densities of 1.7 MW/M3 were obtained. A total power output of 2 kW was generated for tests with 14 electrodes. The power densities obtained in this channel represent a factor of 3 improvement over those previously reported for the M = 0.2 channel.

Sovie, R. J.↗

Results of closed cycle MHD power generation tests with a helium-cesium working fluid

The cross-sectional dimensions of the MHD channel in the NASA Lewis closed loop facility have been reduced to 3.8 x 11.4 cm. Tests were run in this channel using a helium-cesium working fluid at stagnation pressures of 1.6 x 10 to the 5th N/sq m, stagnation temperatures of 2000-2060 K and an entrance Mach number of 0.36. In these tests Faraday open circuit voltages of 200 V were measured which correspond to a Faraday field of 1750 V/m. Power generation tests were run for different groups of electrode configurations and channel lengths. Hall fields up to 1450 V/m were generated. Power extraction per electrode of 183 W and power densities of 1.7 MW/cu m have been obtained. A total power output of 2 kW was generated for tests with 14 electrodes. The power densities obtained in this channel represent a factor of 3 improvement over those reported for the m = 0.2 channel at the last EAM Symposium.

Sovie, R. J.↗

Experimental Sonic Boom Measurements on a Mach 1.6 Cruise Low-Boom Configuration

A wind tunnel test has been conducted by Gulfstream Aerospace Corporation (GAC) to measure the sonic boom pressure signature of a low boom Mach 1.6 cruise business jet in the Langley Unitary Plan Wind Tunnel at Mach numbers 1.60 and 1.80. Through a cooperative agreement between GAC and the National Aeronautics and Space Administration (NASA), GAC provided NASA access to some of the experimental data and NASA is publishing these data for the sonic boom research community. On-track and off-track near field sonic boom pressure signatures were acquired at three separation distances (0.5, 1.2, and 1.7 reference body lengths) and three angles of attack (-0.26deg, 0.26deg, and 0.68deg). The model was blade mounted to minimize the sting effects on the sonic boom signatures. Although no extensive data analysis is provided, selected data are plotted to illustrate salient features of the data. All of the experimental sonic boom pressure data are tabulated. Schlieren images of the configuration are also included.

Wilcox, Floyd J., Jr.↗

Analysis of 7- X 10-foot high speed wind tunnel shaft loads in support of fan blade failure investigation

This is a report of the investigation of the High-Speed 7- X 10-Foot Wind Tunnel at NASA Langley Research Center, which experienced a catastrophic failure of all 18 Sitka spruce fan blades during operation at 0.8 Mach number on 2 July 1985. The High-Speed Tunnel, a closed-circuit/single-return atmospheric wind tunnel, had been operated since 1945 to support a wide range of subsonic aerodynamic tests and studies. The failed blade set had been in use since 1975. In addition to blade loss, the most significant damage was a bent main drive shaft for a total estimated damage loss of 1.7 million dollars. An analysis of the natural frequency characteristics as well as loads, reactions, stresses, and deflections of the fan drive system resulting from steady-state and dynamic loads due to unbalance was performed. Transient load cases were simulated by step input and ramp input loading functions intended to simulate the loss of one to nine blades (maximum unbalance forces).

Faison, Richard W.↗

Truncated Nonlinear Interferometry for Quantum-Enhanced Atomic Force Microscopy

Nonlinear interferometers that replace beam splitters in Mach-Zehnder interferometers with nonlinear amplifiers for quantum-enhanced phase measurements have drawn increasing interest in recent years, but practical quantum sensors based on nonlinear interferometry remain an outstanding challenge. Here, we demonstrate the first practical application of nonlinear interferometry by measuring the displacement of an atomic force microscope microcantilever with quantum noise reduction of up to 3 dB below the standard quantum limit, corresponding to a quantum-enhanced measurement of beam displacement of 1.7 fm/√Hz. Further, we minimize photon backaction noise while taking advantage of quantum noise reduction by transducing the cantilever displacement signal with a weak squeezed state while using dual homodyne detection with a higher power local oscillator. This approach may enable quantum-enhanced broadband, high-speed scanning probe microscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Voyager observations of O(+6) and other minor ions in the solar wind

The plasma science (PLS) experiments on the Voyager 1 and 2 spacecraft began making measurements of the solar wind shortly after the two launches in the fall of 1977. In reviewing the data obtained prior to the Jupiter encounters in 1979, we have found that the large dynamic range of the PLS instrument generally allows a clean separation of signatures of minor ions (about 2.5% of the time) during a single instrument scan in energy per charge. The minor ions, most notably O(+6), are well separated from the protons and alpha particles during times when the solar wind Mach number (ratio of streaming speed to thermal speed) is greater than approximately 15. During the Earth to Jupiter cruise we find that the average ratio of alpha particle number density to that of oxygen is 66 +/- 7 (Voyager 1) and 71 +/- 17 (Voyager 2). These values are consistent with the value 75 +/- 20 inferred from the Ion Composition Instrument on ISEE 3 during the period spanning 1978 and 1982. We have inferred an average coronal temperature of (1.7 +/- 0.1) x 10(exp 6) K based on the ratio of O(+7) to O(+6) number densities. Our observations cover a period of increasing solar activity. During this time we have found that the alpha particle to proton number density ratio is increasing with the solar cycle, the oxygen to proton ratio increases, and the alpha particle to oxygen ratio remains relatively constant in time.

Villanueva, Louis↗

Ballistic range experiments on superbooms generated by refraction

The enhanced sonic boom or supersonic boom generated as a result of atmospheric refraction in threshold Mach number flights was recreated in a ballistic range by firing projectiles at low supersonic speeds into a stratified medium obtained by slowly injecting carbon dioxide into air. The range was equipped with a fast-response dynamic pressure transducer and schlieren photographic equipment, and the sound speed variation with height was controlled by regulating the flow rate of the CO2. The schlieren observations of the resulting flow field indicate that the generated shocks are reflected near the sonic cutoff altitude where local sound speed equals body speed, provided such an altitude exists. Maximum shock strength occurs very nearly at the point where the incident and reflected shocks join, indicating that the presence of the reflected shock may have an appreciable effect on the magnitude of the focus factor. The largest focus factor detected was 1.7 and leads to an estimate that the constant in the Guiraud-Thery scaling law should have a value of 1.30.

Sanai, M.↗