Search NASA⌕ Search

SEARCH · Search NASA

Results for “Magnetic Resonance Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Imaging System

The 1100C Virtual Window is based on technology developed under NASA Small Business Innovation (SBIR) contracts to Ames Research Center. For example, under one contract Dimension Technologies, Inc. developed a large autostereoscopic display for scientific visualization applications. The Virtual Window employs an innovative illumination system to deliver the depth and color of true 3D imaging. Its applications include surgery and Magnetic Resonance Imaging scans, viewing for teleoperated robots, training, and in aviation cockpit displays.

Source record↗

Medical Imaging System

The MD Image System, a true-color image processing system that serves as a diagnostic aid and tool for storage and distribution of images, was developed by Medical Image Management Systems, Huntsville, AL, as a "spinoff from a spinoff." The original spinoff, Geostar 8800, developed by Crystal Image Technologies, Huntsville, incorporates advanced UNIX versions of ELAS (developed by NASA's Earth Resources Laboratory for analysis of Landsat images) for general purpose image processing. The MD Image System is an application of this technology to a medical system that aids in the diagnosis of cancer, and can accept, store and analyze images from other sources such as Magnetic Resonance Imaging.

Source record↗

NASA Tech Briefs, January 2010

Topics covered include: Cryogenic Flow Sensor; Multi-Sensor Mud Detection; Gas Flow Detection System; Mapping Capacitive Coupling Among Pixels in a Sensor Array; Fiber-Based Laser Transmitter for Oxygen A-Band Spectroscopy and Remote Sensing; Low-Profile, Dual-Wavelength, Dual-Polarized Antenna; Time-Separating Heating and Sensor Functions of Thermistors in Precision Thermal Control Applications; Cellular Reflectarray Antenna; A One-Dimensional Synthetic-Aperture Microwave Radiometer; Electrical Switching of Perovskite Thin-Film Resistors; Two-Dimensional Synthetic-Aperture Radiometer; Ethernet-Enabled Power and Communication Module for Embedded Processors; Electrically Variable Resistive Memory Devices; Improved Attachment in a Hybrid Inflatable Pressure Vessel; Electrostatic Separator for Beneficiation of Lunar Soil; Amorphous Rover; Space-Frame Antenna; Gear-Driven Turnbuckle Actuator; In-Situ Focusing Inside a Thermal Vacuum Chamber; Space-Frame Lunar Lander; Wider-Opening Dewar Flasks for Cryogenic Storage; Silicon Oxycarbide Aerogels for High-Temperature Thermal Insulation; Supercapacitor Electrolyte Solvents with Liquid Range Below -80 C; Designs and Materials for Better Coronagraph Occulting Masks; Fuel-Cell-Powered Vehicle with Hybrid Power Management; Fine-Water-Mist Multiple-Orientation-Discharge Fire Extinguisher; Fuel-Cell Water Separator; Turbulence and the Stabilization Principle; Improved Cloud Condensation Nucleus Spectrometer; Better Modeling of Electrostatic Discharge in an Insulator; Sub-Aperture Interferometers; Terahertz Mapping of Microstructure and Thickness Variations; Multiparallel Three-Dimensional Optical Microscopy; Stabilization of Phase of a Sinusoidal Signal Transmitted Over Optical Fiber; Vacuum-Compatible Wideband White Light and Laser Combiner Source System; Optical Tapers as White-Light WGM Resonators; EPR Imaging at a Few Megahertz Using SQUID Detectors; Reducing Field Distortion in Magnetic Resonance Imaging; Fluorogenic Cell-Based Biosensors for Monitoring Microbes; A Constant-Force Resistive Exercise Unit; GUI to Facilitate Research on Biological Damage from Radiation; On-Demand Urine Analyzer; More-Realistic Digital Modeling of a Human Body; and Advanced Liquid-Cooling Garment Using Highly Thermally Conductive Sheets.

Source record↗

Electroencephalographic imaging of higher brain function

High temporal resolution is necessary to resolve the rapidly changing patterns of brain activity that underlie mental function. Electroencephalography (EEG) provides temporal resolution in the millisecond range. However, traditional EEG technology and practice provide insufficient spatial detail to identify relationships between brain electrical events and structures and functions visualized by magnetic resonance imaging or positron emission tomography. Recent advances help to overcome this problem by recording EEGs from more electrodes, by registering EEG data with anatomical images, and by correcting the distortion caused by volume conduction of EEG signals through the skull and scalp. In addition, statistical measurements of sub-second interdependences between EEG time-series recorded from different locations can help to generate hypotheses about the instantaneous functional networks that form between different cortical regions during perception, thought and action. Example applications are presented from studies of language, attention and working memory. Along with its unique ability to monitor brain function as people perform everyday activities in the real world, these advances make modern EEG an invaluable complement to other functional neuroimaging modalities.

Non-NASA Center↗

Gradient-based surface nuclear magnetic resonance for groundwater investigation

In medical magnetic resonance imaging, spatial localization (imaging) is based upon the application of controlled magnetic field gradients on top of the main magnetic field to spatially modulate the frequency and/or phase of the nuclear magnetic resonance (NMR) signal across the volume of investigation. In this work, we have applied similar physical principles to produce controlled magnetic field gradients during surface NMR-based groundwater investigations. In this approach, a gradient pulse of variable amplitude or duration is applied immediately after the excitation pulse to cause predictable phase encoding of the NMR signal as a function of depth. This approach is also applicable to emerging surface NMR detection methods that use a prepolarization field with fast nonadiabatic turn-off to generate detectable NMR signals from the shallow subsurface. In this case, the gradient pulse is applied after terminating the prepolarization field and provides a heretofore unavailable means of localizing the NMR response as a function of depth. The application of gradients can also be combined with tip-angle-based modulation to yield higher imaging resolution than can be achieved through either gradient- or tip-angle-based imaging alone. We implemented this new gradient-based capability into a surface NMR gradient generation accessory that is compatible with the GMR-Flex instrument and developed surface NMR-specific forward modeling and linear inverse models. We validated the accuracy of this novel gradient-based sNMR technology using computer simulations, experiments using a small pool filled with a discrete layer of bulk water, and field experiments at well-characterized groundwater test sites along Ebey Island, WA, and Larned, KS. The gradient-based sNMR imaging observations were compared with high-resolution direct push NMR results observed at these sites. The results of computer simulations and field experiments indicate improvements in both the detection (signal-to-noise ratio) and spatial resolution of shallow subsurface water content using gradient-based surface NMR, compared with traditional surface NMR imaging methods.

Geochemistry & Geophysics↗

Spray-Deposited Superconductor/Polymer Coatings

Coatings that exhibit the Meissner effect formed at relatively low temperature. High-temperature-superconductor/polymer coatings that exhibit Meissner effect deposited onto components in variety of shapes and materials. Simple, readily available equipment needed in coating process, mean coatings produced economically. Coatings used to keep magnetic fields away from electronic circuits in such cryogenic applications as magnetic resonance imaging and detection of infrared, and in magnetic suspensions to provide levitation and/or damping of vibrations.

Wise, Stephanie A.↗

The Visible Human Project of the National Library of Medicine: Remote access and distribution of a multi-gigabyte data set

As part of the 1986 Long-Range Plan for the National Library of Medicine (NLM), the Planning Panel on Medical Education wrote that NLM should '...thoroughly and systematically investigate the technical requirements for and feasibility of instituting a biomedical images library.' The panel noted the increasing use of images in clinical practice and biomedical research. An image library would complement NLM's existing bibliographic and factual database services and would ideally be available through the same computer networks as are these current NLM services. Early in 1989, NLM's Board of Regents convened an ad hoc planning panel to explore possible roles for the NLM in the area of electronic image libraries. In its report to the Board of Regents, the NLM Planning Panel on Electronic Image Libraries recommended that 'NLM should undertake a first project building a digital image library of volumetric data representing a complete, normal adult male and female. This Visible Human Project will include digitized photographic images for cryosectioning, digital images derived from computerized tomography, and digital magnetic resonance images of cadavers.' The technologies needed to support digital high resolution image libraries, including rapid development; and that NLM encourage investigator-initiated research into methods for representing and linking spatial and textual information, structural informatics. The first part of the Visible Human Project is the acquisition of cross-sectional CT and MRI digital images and cross-sectional cryosectional photographic images of a representative male and female cadaver at an average of one millimeter intervals. The corresponding cross-sections in each of the three modalities are to be registerable with one another.

Ackerman, Michael J.↗

Comparisons Between NO PLIF Imaging and CFD Simulations of Mixing Flowfields for High-Speed Fuel Injectors

The current work compares experimentally and computationally obtained nitric oxide (NO) planar laser induced fluorescence (PLIF) images of the mixing flowfields for three types of high-speed fuel injectors: a strut, a ramp, and a rectangular flushwall. These injection devices, which exhibited promising mixing performance at lower flight Mach numbers, are currently being studied as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. The EIMP aims to investigate scramjet fuel injection and mixing physics, and improve the understanding of underlying physical processes relevant to flight Mach numbers greater than eight. In the experiments, conducted in the NASA Langley Arc-Heated Scramjet Test Facility (AHSTF), the injectors are placed downstream of a Mach 6 facility nozzle, which simulates the high Mach number air flow at the entrance of a scramjet combustor. Helium is used as an inert substitute for hydrogen fuel. Both schlieren and PLIF techniques are applied to obtain mixing flowfield flow visualizations. The experimental PLIF is obtained by using a UV laser sheet to interrogate a plane of the flow by exciting fluorescence from the NO molecules, which are present in the AHSTF air. Consequently, the absence of signal in the resulting PLIF images is an indication of pure helium (fuel). The computational PLIF is obtained by applying a fluorescence model for NO to the results of the Reynolds-averaged simulations (RAS) of the mixing flow field carried out using the VULCAN-CFD solver. This approach is required because the PLIF signal is a nonlinear function of not only NO concentration, but also pressure, temperature, and the flow velocity. This complexity allows additional flow features to be identified and compared with those obtained from the computational fluid dynamics (CFD) simulations, however, such comparisons are only semiquantitative. Three-dimensional image reconstruction, similar to that used in magnetic resonance imaging, is also used to obtain images in the streamwise and spanwise planes from select cross-stream PLIF plane data. Synthetic schlieren is also computed from the RAS data. Good agreement between the experimental and computational results provides increased confidence in the CFD simulations for investigations of injector performance.

Drozda, Tomasz G.↗

Comparisons Between NO PLIF Imaging and CFD Simulations of Mixing Flowfields for High-Speed Fuel Injectors

The current work compares experimentally and computationally obtained nitric oxide (NO) planar laser-induced fluorescence (PLIF) images of the mixing flowfields for three types of high-speed fuel injectors: a strut, a ramp, and a rectangular flushwall. These injection devices, which exhibited promising mixing performance at lower flight Mach numbers, are currently being studied as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. The EIMP aims to investigate scramjet fuel injection and mixing physics, and improve the understanding of underlying physical processes relevant to flight Mach numbers greater than eight. In the experiments conducted in the NASA Langley Arc-Heated Scramjet Test Facility (AHSTF), the injectors are placed downstream of a Mach 6 facility nozzle, which simulates the high Mach number air flow at the entrance of a scramjet combustor. Helium is used as an inert substitute for hydrogen fuel. Both schlieren and PLIF techniques are applied to obtain mixing flowfield flow visualizations. The experimental PLIF is obtained by using a UV laser sheet to interrogate a plane of the flow by exciting fluorescence from the NO molecules that are present in the AHSTF air. Consequently, the absence of signal in the resulting PLIF images is an indication of pure helium (fuel). The computational PLIF is obtained by applying a fluorescence model for NO to the results of the Reynolds-averaged simulations (RAS) of the mixing flowfield carried out using the VULCAN-CFD solver. This approach is required because the PLIF signal is a nonlinear function of not only NO concentration, but also pressure, temperature, and the flow velocity. This complexity allows additional flow features to be identified and compared with those obtained from the computational fluid dynamics (CFD) simulations, however, such comparisons are only semiquantitative. Three-dimensional image reconstruction, similar to that used in magnetic resonance imaging, is also used to obtain images in the streamwise and spanwise planes from select cross-stream PLIF plane data. Synthetic schlieren is also computed from the RAS data. Good agreement between the experimental and computational results provides increased confidence in the CFD simulations for investigations of injector performance.

PLIF↗

Comparisons Between NO PLIF Imaging and CFD Simulations of Mixing Flowfields for High-Speed Fuel Injectors

The current work compares experimentally and computationally obtained nitric oxide (NO) planar laser-induced fluorescence (PLIF) images of the mixing flowfields for three types of high-speed fuel injectors: a strut, a ramp, and a rectangular flushwall. These injection devices, which exhibited promising mixing performance at lower flight Mach numbers, are currently being studied as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. The EIMP aims to investigate scramjet fuel injection and mixing physics, and improve the understanding of underlying physical processes relevant to flight Mach numbers greater than eight. In the experiments conducted in the NASA Langley Arc-Heated Scramjet Test Facility (AHSTF), the injectors are placed downstream of a Mach 6 facility nozzle, which simulates the high Mach number air flow at the entrance of a scramjet combustor. Helium is used as an inert substitute for hydrogen fuel. Both schlieren and PLIF techniques are applied to obtain mixing flowfield flow visualizations. The experimental PLIF is obtained by using a UV laser sheet to interrogate a plane of the flow by exciting fluorescence from the NO molecules that are present in the AHSTF air. Consequently, the absence of signal in the resulting PLIF images is an indication of pure helium (fuel). The computational PLIF is obtained by applying a fluorescence model for NO to the results of the Reynolds-averaged simulations (RAS) of the mixing flowfield carried out using the VULCAN-CFD solver. This approach is required because the PLIF signal is a nonlinear function of not only NO concentration, but also pressure, temperature, and the flow velocity. This complexity allows additional flow features to be identified and compared with those obtained from the computational fluid dynamics (CFD) simulations, however, such comparisons are only semiquantitative. Three-dimensional image reconstruction, similar to that used in magnetic resonance imaging, is also used to obtain images in the streamwise and spanwise planes from select cross-stream PLIF plane data. Synthetic schlieren is also computed from the RAS data. Good agreement between the experimental and computational results provides increased confidence in the CFD simulations for investigations of injector performance.

PLIF↗

Enabling Space Biological Knowledge Discovery Through Image and Video Data Sharing

Increased biomedical risks and challenges associated with deep space missions and experiments (cis-Lunar, Mars transit/surface) require new knowledge discovery and development of novel ecosystems. Supporting distant and long-duration missions and experiments requires biological data (from yeast, microbes, fruit flies, C. elegans, plants, crops, rodents, humans) be findable, accessible, interoperable, reusable (FAIR), and maximally open-access. As data-intensive, bioinformatic, meta-analytical, and computer-assisted approaches continue to be a centerpiece of modern research, the NASA Biological and Physical Sciences division is expanding its Open Science capabilities beyond NASA GeneLab. The NASA Ames Life Sciences Data Archive (ALSDA) is a repository which is responsible for collecting and access to space biological imagery and video, alongside tabular and environmental data. In this presentation, we will discuss strategies dealing with archiving, curating, and accessibility of images from very distinct imaging modalities (e.g., micro-computed tomography, magnetic resonance imaging, photographic images of plants, fluorescence microscopy, behavioral videos, etc.). There are two main challenges: 1. Open-source data storage and 2. Metadata related to the imagery-video. Both have been solved by leveraging two existing open-source systems. For data storage, ALSDA is utilizing components through the Open Microscopy Environment (OME), which can read most imaging proprietary formats and display on a web interface complex multidimensional images (Z stack, multi-channel, temporal, spectral). Most technical metadata from imaging modalities are captured seamlessly. For metadata capturing experimental details, ALSDA (like GeneLab) uses the ISA-Tab specification which relies on the ISA data model to order and classify metadata. The ISA data model uses a tree structure with three files to capture the metadata: The top layer is the Investigations file, the second layer is the Study file(s), and the last layer is the Assay file(s). We believe such an approach may be useful for other types of image research data from other investigators in the AGU community.

imaging↗

Developing Open-Source Training Materials for AI/ML and Space Biological Sciences Using NASA Cloud-Based Data

Artificial Intelligence (AI) and Machine Learning (ML) has gained significant traction in the biological and biomedical research fields in the last two decades, in part thanks to an increasing culture of open data sharing and reuse. Due to its capability for identifying complex relationships and patterns, AI/ML methodology is particularly well suited to recognize and predict biological patterns from high-dimensional next-generation sequencing data (e.g. whole genome sequencing, transcriptomic sequencing), as well as from biological or medical imaging data (e.g. microscopy, computed tomography, ultrasound, magnetic resonance imaging, radiography). These methodologies hold particular promise for space biosciences research and automated space health monitoring systems. However, there are many key considerations for properly training, validating, and testing a machine learning model in biological research or clinical application. Even with the positive culture of Open Science and data sharing, inexperienced researchers working quickly without proper checks can produce models that perform poorly outside of the immediate training dataset. Lessons learned from biological AI/ML research indicate that Open Science principles such as data sharing and open-source code must go hand-in-hand with publicly available, high-quality training curricula in best practices, with modules centered on real-life scientific use cases and data so future AI/ML practitioners gain experience on real problems. Here we present the development of open-source training materials for AI/ML and space biosciences, as part of the NASA Transform to Open Science Training (TOPST) initiative. We develop 4 independent training programs, focused on the following topics: 1) Fundamentals of Machine Learning and Space Biosciences Domain, 2) Open Science, Artificial Intelligence, and Ethical Best Practices for Data Sharing and Analysis, 3) Using AI/ML Classification to Identify Gene Networks Affected By Space Exposure in Mouse Liver, and 4) Using Neural Networks to Find DNA Damage Patterns in Immune Cells after Radiation. All programs leverage cloud-based NASA biological datasets. The curriculum we present will enable worldwide access to training in AI/ML and scientific analysis.

James Andrew Casaletto↗

Developing Open-Source Training Materials for AI/ML and Space Biological Sciences Using NASA Cloud-Based Data

Artificial Intelligence (AI) and Machine Learning (ML) has gained significant traction in the biological and biomedical research fields, in part due to a culture of open data sharing and reuse. AI/ML methodology is well-suited to recognize and predict biological patterns from high-dimensional next-generation sequencing data (e.g. whole genome sequencing, transcriptomic sequencing), as well as from biological or medical imaging data (e.g. microscopy, computed tomography, ultrasound, magnetic resonance imaging, radiography). These methodologies hold particular promise for space biosciences research and automated space health monitoring systems. However, there are key considerations for properly training, validating, and testing a machine learning model in biological research or clinical application. Inexperienced researchers can produce models that perform poorly outside of the training dataset. Open Science principles such as data sharing and open-source code must go hand-in-hand with publicly available, high-quality training curricula in best practices, with modules centered on real-life scientific use cases and data so future AI/ML practitioners gain experience on real problems. Here we present the development of open-source training materials for AI/ML and space biosciences, as part of the NASA Transform to Open Science Training (TOPST) initiative. We develop 4 independent training programs, focused on the following topics: 1) Fundamentals of Machine Learning and Space Biosciences Domain, 2) Open Science, Artificial Intelligence, and Ethical Best Practices for Data Sharing and Analysis, 3) Using AI/ML Classification to Identify Gene Networks Affected By Space Exposure in Mouse Liver, and 4) Using Neural Networks to Find DNA Damage Patterns in Immune Cells after Radiation. All programs leverage cloud-based NASA biological datasets. The curriculum we present will enable worldwide access to training in AI/ML and scientific analysis.

James Casaletto↗

Lumbar spine disc heights and curvature: upright posture vs. supine compression harness

INTRODUCTION: Spinal lengthening in microgravity is thought to cause back pain in astronauts. A spinal compression harness can compress the spine to eliminate lengthening but the loading condition with harness is different than physiologic conditions. Our purpose was to compare the effect of spine compression with a harness in supine position on disk height and spinal curvature in the lumbar spine to that of upright position as measured using a vertically open magnetic resonance imaging system. METHODS: Fifteen healthy subjects volunteered. On day 1, each subject lay supine for an hour and a baseline scan of the lumbar spine was performed. After applying a load of fifty percent of body weight with the harness for thirty minutes, the lumbar spine was scanned again. On day 2, after a baseline scan, a follow up scan was performed after kneeling for thirty minutes within the gap between two vertically oriented magnetic coils. Anterior and posterior disk heights, posterior disk bulging, and spinal curvature were measured from the baseline and follow up scans. RESULTS: Anterior disk heights increased and posterior disk heights decreased compared with baseline scans both after spinal compression with harness and upright posture. The spinal curvature increased by both loading conditions of the spine. DISCUSSION: The spinal compression with specially designed harness has the same effect as the physiologic loading of the spine in the kneeling upright position. The harness shows some promise as a tool to increase the diagnostic capabilities of a conventional MR system.

Non-NASA Center↗

See-saw nystagmus and brainstem infarction: MRI findings

A patient with see-saw nystagmus had a lesion localized by Magnetic Resonance Imaging (MRI) to the paramedian ventral midbrain with involvement of the right interstitial nucleus of Cajal. This the first MRI study of see-saw nystagmus associated with a presumed brainstem vascular event. Our findings support animal and human studies suggesting that dysfunction of the interstitial nucleus of Cajal or its connections is central in this disorder.

Non-NASA Center↗

A common network of functional areas for attention and eye movements

Functional magnetic resonance imaging (fMRI) and surface-based representations of brain activity were used to compare the functional anatomy of two tasks, one involving covert shifts of attention to peripheral visual stimuli, the other involving both attentional and saccadic shifts to the same stimuli. Overlapping regional networks in parietal, frontal, and temporal lobes were active in both tasks. This anatomical overlap is consistent with the hypothesis that attentional and oculomotor processes are tightly integrated at the neural level.

Non-NASA Center↗

Tau accumulation and atrophy predict amyloid independent cognitive decline in aging

INTRODUCTION: Amyloid beta (Aβ) and tau pathology are cross-sectionally associated with atrophy and cognitive decline in aging and Alzheimer's disease (AD). METHODS: We investigated relationships between concurrent longitudinal measures of Aβ (Pittsburgh compound B [PiB] positron emission tomography [PET]), tau (flortaucipir [FTP] PET), atrophy (structural magnetic resonance imaging), episodic memory (EM), and non-memory (NM) in 78 cognitively healthy older adults (OA). RESULTS: Entorhinal FTP change was correlated with EM decline regardless of Aβ, but meta-temporal FTP and global PiB change were only associated with EM and NM decline in Aβ+ OA. Voxel-wise analyses revealed significant associations between temporal lobe FTP change and EM decline in all groups. PiB and FTP change were not associated with structural change, suggesting a functional or microstructural mechanism linking these measures to cognitive decline. DISCUSSION: Our results show that longitudinal Aβ is linked to cognitive decline only in the presence of elevated Aβ, but longitudinal temporal lobe tau is associated with memory decline regardless of Aβ status.

60 APPLIED LIFE SCIENCES↗

Preservation of auditory and vestibular function after surgical removal of bilateral vestibular schwannomas in a patient with neurofibromatosis type 2

The outcome of acoustic neuroma (vestibular schwannoma) surgery continues to improve rapidly. Advances can be attributed to several fields, but the most important contributions have arisen from the identification of the genes responsible for the dominant inheritance of neurofibromatosis types 1 (NF1) and 2 (NF2) and the development of magnetic resonance imaging with gadolinium enhancement for the early anatomic confirmation of the pathognomonic, bilateral vestibular schwannomas in NF2. These advances enable early diagnosis and treatment when the tumors are small in virtually all subjects at risk for NF2. The authors suggest that advising young NF2 patients to wait until complications develop, especially hearing loss, before diagnosing and operating for bilateral eighth nerve schwannomas may not always be in the best interest of the patient. To the authors' knowledge, this is the first reported case of preservation of both auditory and vestibular function in a patient after bilateral vestibular schwannoma excision.

Case Reports↗