Search NASA⌕ Search

SEARCH · Search NASA

Results for “Marx”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Precision high energy liner implosion experiments PHELIX [1]

This paper describes the hardware design of a small megajoule sized transformer coupled pulse power system utilized to drive hydrodynamic liner experiments with a nominal current capability of 10 megAmperes. The resulting liner velocities and characteristics provide properties of physics interest. The capacitor banks utilize the ''Atlas'' plastic cased 60 kV, 60 kJ capacitors [2] and railgaps [3]. The air insulated marx'S are configured to dive a multi-filar toroidal transformer. The 4:1 multi-filar toroidal transformer is mechanically part of a circular disc line and this feature results in an attractive inductance budget. Because of the compact size, re-usable transformer, and resulting low maintenance cost, shot rates can be high compared to other ''large'' machines or explosively driven hydrodynamic methods. The PHELIX modeling, construction status, and test results will also be provided.

42 ENGINEERING↗

Effect of soft metal gasket contacts on contact resistance, energy deposition, and plasma expansion profile in a wire array Z pinch

Soft metal gaskets (indium and silver) were used to reduce contact resistance between the wire and the electrode in an aluminum wire Z pinch by more than an order of magnitude over the best weighted contact case. Clamping a gasket over a Z-pinch wire compresses the wire to the electrode with a greater normal force than possible with wire weights. Average contact resistance was reduced from the range of 100-3000 {omega} (depending on wire weight mass) to 1-10 {omega} with soft metal gaskets. Single wire experiments (13 {mu}m Al 5056) on a 16 kA, 100 kV Marx bank showed an increase in light emission (97%) and emission volume (100%) of the plasma for the reduced contact resistance cases. The measured increases in plasma volume and light emission indicate greater energy deposition in the ablated wire. Additionally, dual-wire experiments showed plasma edge effects were significantly decreased in the soft metal gasket contact case. The average height of the edge effects was reduced by 51% and the width of the edge effects was increased by 40%, thus the gasket contact case provided greater axial uniformity in the plasma expansion profile of an individual wire.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time X-ray Diffraction Measurements of Shocked Polycrystalline Tin and Aluminum

A new, fast, single-pulse x-ray diffraction (XRD) diagnostic for determining phase transitions in shocked polycrystalline materials has been developed. The diagnostic consists of a 37-stage Marx bank high-voltage pulse generator coupled to a needle-and-washer electron beam diode via coaxial cable, producing line and bremsstrahlung x-ray emission in a 35-ns pulse. The characteristic Kα lines from the selected anodes of silver and molybdenum are used to produce the diffraction patterns, with thin foil filters employed to remove the characteristic Kβ line emission. The x-ray beam passes through a pinhole collimator and is incident on the sample with an approximately 3-mm by 6-mm spot and 1° full-width-half-maximum (FWHM) angular divergence in a Bragg-reflecting geometry. For the experiments described in this report, the angle between the incident beam and the sample surface was 8.5°. A Debye-Scherrer diffraction image was produced on a phosphor located 76 mm from the polycrystalline sample surface. The phosphor image was coupled to a charge-coupled device (CCD) camera through a coherent fiberoptic bundle. Dynamic single-pulse XRD experiments were conducted with thin foil samples of tin, shock loaded with a 1-mm vitreous carbon back window. Detasheet high explosive with a 2-mm-thick aluminum buffer was used to shock the sample. Analysis of the dynamic shock-loaded tin XRD images revealed a phase transformation of the tin beta phase into an amorphous or liquid state. Identical experiments with shock-loaded aluminum indicated compression of the face-centered-cubic (fcc) aluminum lattice with no phase transformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kinetic simulation studies of laser-triggering in the Z gas switch

Advanced z-pinch accelerators require precise timing of multiple mega-ampere drivers to deliver terawatt power. The triggering of these drivers is now largely initiated by laser ionization of gas switches. In this paper, we discuss detailed fully kinetic simulation of the Z laser-triggered gas switch involving detailed finite-difference time-domain particle-in-cell Monte Carlo modeling of the trigger section of the switch. Other components of the accelerator from the Marx bank through the pulse-forming line are described as circuit elements. The simulations presented here build on a recently developed model of electro-negative gas breakdown and streamer propagation that included photons produced from de-excited neutrals. New effects include multi-photon ionization of the gas in a prescribed laser field. The simulations show the sensitivity of triggering to laser parameters including focal plane within the anode-cathode gap of the trigger section of the switch, intensity at focus, and laser pulse length. Detailed electromagnetic simulations of the trigger section with circuit modeling of the upstream and downstream components are largely in agreement with Z data and demonstrate a new capability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of a metallic photonic crystal high power microwave mode converter

It is demonstrated that an L band metallic photonic crystal TEM-TE{sub 11} mode converter is suitable for narrow band high power microwave application. The proposed mode converter is realized by partially filling metallic photonic crystals along azimuthal direction in a coaxial transmission line for phase-shifting. A three rows structure is designed and simulated by commercial software CST Microwave Studio. Simulation results show that its conversion efficiency is 99% at the center frequency 1.58 GHz. Over the frequency range of 1.56-1.625 GHz, the conversion efficiency exceeds 90 %, with a corresponding bandwidth of 4.1 %. This mode converter has a gigawatt level power handling capability which is suitable for narrow band high power microwave application. Using magnetically insulated transmission line oscillator(MILO) as a high power microwave source, particle-in-cell simulation is carried out to test the performance of the mode converter. The expected TE{sub 11} mode microwave output is obtained and the MILO works well. Mode conversion performance of the converter is tested by far-field measurement method. And the experimental result confirms the validity of our design. Then, high power microwave experiment is carried out on a Marx-driven Blumlein water line pulsed power accelerator. Microwave frequency, radiated pattern and power are measured in the far-field region and the results agree well with simulation results. The experiment also reveals that no microwave breakdown or pulse shortening took place in the experimental setup.

36 MATERIALS SCIENCE↗

X-pinch X-ray emission on a portable low-current, fast rise-time generator

In this paper, we report on experiments exploring X-ray emission from an X-pinch driven by a small Marx-waterline generator supplying 50 kA with a risetime of 50 ns and a peak voltage of ~250 kV. Both standard crossed wire loads and hybrid loads utilizing conical metal electrodes with a single short wire in between them were studied, and in both cases reliable modes of operation were obtained for X-ray radiography. Soft (few keV) and Hard (>5 keV) X-ray emission characteristics were observed. With standard X-pinches, soft radiation emanated from a small hot spot about 3 μm in size, along with hard radiation from a ~200 μm region close to this hot spot. With hybrid X-pinches, the hot spot was <7 μm in size. Finally, there was a clear correlation between the soft and hard X-ray emission—pinches that produced intense soft X-ray emission from a small hot spot also produced the most intense, localized hard X-ray emission.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A parametric SPICE model for the simulation of spark gap switches

The use of SPICE-based software for the simulation of pulsed power systems—even large complex systems—has become commonplace in the pulsed power community. This is in contrast to earlier work in the field that relied on specially developed simulation codes such as Sandia’s Screamer or the Navy Research Lab’s Bertha, which natively incorporated models for common pulsed power components such as spark gap switches. Unlike these programs, SPICE programs provide a simple and familiar user interface and wide availability. However, SPICE programs do not include realistic models for key pulsed power circuit devices—including the spark gap switch. While simple switch models do exist in SPICE programs, these can only crudely approximate the behavior of a spark gap. This effort focuses on developing an SPICE circuit model for a gas-filled spark gap switch that is physically realistic while being simple enough to permit simulations to run in reasonable times on typical personal computers. Detailed information is provided for implementation in two common versions of SPICE: LTspice and Orcad PSPICE. Adaptation to other SPICE programs is possible with minimal modification. The model is intended as a design tool that uses physical parameters as inputs to connect it directly to the development of useable pulsed power systems. Data collected from the operation of a high-pressure pulsed-charged switch and a complete 12-stage Marx generator have been used to demonstrate the implementation and accuracy of the model over a wide range of parameters.

Pouncey, J. Cameron (ORCID:0000000153500816)↗

Load dynamics of double planar foil liners and double planar wire arrays on the UM MAIZE LTD generator

In previous studies using the University of Nevada, Reno's (UNR's) high-impedance Zebra Marx generator (1.9 Ω, 1.7 MA, 100 ns), Double Planar Wire Arrays (DPWAs) proved to be excellent radiators, and Double Planar Foil Liners (DPFLs) proved useful for future inertial confinement fusion applications. This article presents the results of joint UNR/UM (University of Michigan) experiments with aluminum (Al) DPWAs, Al DPFLs, and tungsten (W) DPWAs using UM's Michigan Accelerator for Inductive Z-Pinch Experiments (MAIZE) generator, a low-impedance Linear Transformer Driver (LTD) (0.1 Ω, 0.5–1 MA, and 100–250 ns). The main goals of this study were twofold: the first was a pioneering effort to test whether a relatively heavy Al DPFL could successfully be imploded on a low-impedance university-scale LTD like the MAIZE generator, and, if so, to analyze the results and make comparisons to the optimized, lighter DPWA configurations that have been previously studied. The DPWAs consisted of two planes of micrometer-scale diameter Al or W wires, while the DPFLs consisted of two planes of micrometer-scale thickness Al foils. Diagnostics include filtered Si-diodes, an absolutely calibrated filtered PCD, x-ray pinhole cameras, spectrometers, and gated optical self-emission imaging. The implosion dynamics and radiative properties of Al DPWAs and DPFLs and W DPWAs on the MAIZE LTD are discussed and compared. Time-dependent load inductance calculations derived from measurements of the load current and a MAIZE circuit model provide a relative measurement of pinch strength. In experiments on MAIZE, W planar wire arrays exhibited a higher peak load inductance throughout the pinch than Al DPWAs and DPFLs, while x-ray pulses from Al DPFLs had the longest emission duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluating the impact of air terminal geometry on lightning intercept efficacy under a strong background electric field

A comparative analysis of the attachment efficacy of sharpened vs blunted air terminals under a strong background DC electric field, similar to conditions found in naturally occurring lightning events, is presented. Testing was conducted using an oil-free, 17-stage, 1.4 MV bipolar Marx generator with a biased discharge plane that emulated the conditions found prior to the lightning return stroke. The biased discharge plane allowed the introduction of a strong DC electric field and subsequent corona formation on a time scale much longer than the brief duration over which the downward leader propagates. Initial observations indicate that despite a higher background electric field at the sharpened terminals, leading to pre-discharge corona formation where none is seen on the blunt terminal, both the sharpened and blunted terminals exhibit similar attachment probabilities during discharge events, with some discharge events attaching to both terminals.

54 ENVIRONMENTAL SCIENCES↗

A LINE-OF-SIGHT GALAXY CLUSTER COLLISION: SIMULATED X-RAY OBSERVATIONS

Several lines of evidence have suggested that the galaxy cluster Cl 0024+17, an apparently relaxed system, is actually a collision of two clusters, the interaction occurring along our line of sight. In this paper, we present a high-resolution N-body/hydrodynamics simulation of such a collision. We have created mock X-ray observations of our simulated system using MARX, a program that simulates the on-orbit performance of the Chandra X-ray Observatory. We analyze these simulated data to generate radial profiles of the surface brightness and temperature. At later times, t = 2.0-3.0 Gyr after the collision, the simulated surface brightness profiles are better fit by a superposition of two {beta}-model profiles than a single profile, in agreement with the observations of Cl 0024+17. In general, due to projection effects, much of the post-collision density and temperature structure of the clusters is not seen in the observations. In particular, the observed temperatures from spectral fitting are much lower than the temperature of the hottest gas. We determine from our fitted profiles that if the system is modeled as a single cluster, the hydrostatic mass estimate is a factor {approx}2-3 less than the actual mass, but if the system is modeled as two galaxy clusters in superposition, a hydrostatic mass estimation can be made which is accurate to within {approx}10%. We examine some implications of these results for galaxy cluster X-ray surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

PHELIX

Explore the source record for details and available documents.

Rousculp, Christopher L↗

Suppressing Thermal Energy Drift In The LLNL Flash X-Ray Accelerator Using Linear Disk Resistor Stacks

This paper addresses thermal drift in sodium thiosulfate liquid resistors and their replacement with linear disk resistors from HVR Advanced Power Components. Sodium thiosulfate resistors in the FXR induction linear accelerator application have a temperature coefficient of {approx}1.8%/C. The FXR Marx banks send an 8kJ pulse through eight 524 cm{sup 3} liquid resistors at a repetition rate of up to 1 every 45 seconds. Every pulse increases the temperature of the solution by {approx}0.4 C which produces a 0.7% change in resistance. The typical cooling rate is {approx}0.4 C per minute which results in {approx}0.1% energy drop per pulse during continuous pulsed operations. A radiographic accelerator is extraordinarily sensitive to energy variations. Changes in beam energy produce movement in beam transport, changes in spot size, and large dose variations. If self-heating were the only problem, we could predict the increase in input voltage required to compensate for the energy loss. However, there are other variables that influence the temperature of the resistors such as focus magnet heating, changes in room temperature, changes in cooling water, where the cell is located, etc. Additionally not all of the resistors have equivalent cooling rates and as many as 32 resistors are driven from a single power source. The FXR accelerator group elected to replace the sodium thiosulfate resistors with HVR Linear Disk Resistors in a stack type configuration. With data limited for these resistors when used in oil and at low resistance values, a full characterization needed to be performed. High currents (up to 15kA), high voltages (up to 400kV), and Fast Rise times (<10ns) made a resistor choice difficult. Other solid resistors have been tried and had problems at the connection points and with the fact that the resistivity changed as they absorbed oil. The selected HVR resistors have the advantage of being manufactured with the oil impregnated in to them so this characteristic is minimized while still offering the desired low temperature coefficient of resistance compared to sodium thiosulfate. The characterization experiments and comparison with the sodium thiosulfate liquid resistors will be fully discussed and the final design described.

42 ENGINEERING↗

Experiments to Quantify the Shielding Efficacy of Materials to be Implemented for Portable Shielding Enclosures that Adequately Mitigate EMI from Lighting Attachment Events

Mitigating electric and magnetic fields induced by lightning strike events is critical for the security and longevity of electrical components. Electromagnetic interference originating from a lightning strike is categorized into the low to medium frequency ranges, commonly referred to as the “magnetic coupling” regime. This low-frequency characteristic brings about the problem of shielding magnetic flux lines. Such shielding can be accomplished with highly conductive materials via the generation of eddy currents or by diverting the flux lines using materials with a large relative permeability. The shielding effectiveness of materials with varying thicknesses and geometry are tested using a pulse forming network having comparable characteristics to a scaled lighting strike. A four-stage Marx generator with a peak current of ~33 kA and a risetime of 1.4 μs is used as the pulse forming network to emulate the scaled electric and magnetic fields. The data collected from these experiments provide information and techniques that can be implemented into the design of a portable, deployable shielding enclosure.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nanosecond pulsed power generator for a voltage amplitude up to 300 kV and a repetition rate up to 16 Hz for fine disintegration of quartz

A generator of high-power high-voltage nanosecond pulses is intended for electrical discharge disintegration of mineral quartz and other nonconducting minerals. It includes a 320 kV Marx pulsed voltage generator, a high-voltage glycerin-insulated coaxial peaking capacitor, and an output gas spark switch followed by a load, an electric discharge disintegration chamber. The main parameters of the generator are as follows: a voltage pulse amplitude of up to 300 kV, an output impedance of ≈10 Ω, a discharge current amplitude of up to 25 kA for a half-period of 80–90 ns, and a pulse repetition rate of up to 16 Hz.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

D-25 OBSERVATIONS OF SHOCKED METALLIC SURFACES WITH SINGLE-PULSE X-RAY DIFFRACTION

A single-pulse x-ray diffraction (XRD) diagnostic has been developed for the investigation of shocked material properties on a very short time scale. The diagnostic, which consists of a 37-stage Marx bank high-voltage pulse generator coupled to a needle-and-washer electron beam diode via coaxial cable, produces line and bremsstrahlung x-ray emission in a 40-ns pulse. A selected anode of either silver or molybdenum produces characteristic K lines used for diffraction. The x-ray beam passes through a pinhole collimator and is incident on the sample with an approximately 2-mm by 5-mm spot and 1° full-width-half-maximum angular divergence. Coherent scattering from the sample produces a Debye-Scherrer diffraction pattern on an image plate 75 mm from the polycrystalline sample surface. An experimental study of the polycrystalline structures of zirconium and tin under high-pressure shock loading has been conducted with single-pulse XRD. The experimental targets were 0.1-mm-thick foils of zirconium and tin using 0.4-mm-thick vitreous carbon back windows for shock-loading, and the shocks were produced by either Detasheet or PBX-9501 high explosives buffered by 1-mm-thick 6061-T6 aluminum. The diffraction patterns from both shocked zirconium and tin indicated a phase transition into a polymorphic mix of amorphous and new solid phases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observations of Shock-Loaded Tin and Zirconium Surfaces with Single-Pulse X-ray Diffraction

A single-pulse X-ray diffraction (XRD) diagnostic has been developed for the investigation of shocked material properties on a very short time scale. The diagnostic, which consists of a 37-stage Marx bank high-voltage pulse generator coupled to a needle-and-washer electron beam diode via coaxial cable, produces line-and-bremsstrahlung X-ray emission in a 40 ns pulse. The molybdenum anode produces 0.71 Å characteristic K lines used for diffraction. The X-ray beam passes through a pinhole collimator and is incident on the sample with an approximately 2 mm×5 mm spot and 1° full width at half maximum angular divergence. Coherent scattering from the sample produces a Debye-Scherrer diffraction pattern on an image plate located at 75 mm from the polycrystalline sample surface. An experimental study of the polycrystalline structures of zirconium and tin under high-pressure shock loading has been conducted with single-pulse XRD. The experimental targets were 0.1-mm-thick foils of zirconium and tin using 0.4-mm-thick vitreous carbon back windows for shock loading, and the shocks were produced by either Detasheet or PBX-9501 high explosives buffered by 1-mm-thick 6061-T6 aluminum. The diffraction patterns from both shocked zirconium and tin indicated a phase transition into a polymorphic mix of amorphous and new solid phases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cygnus Dual Beam Radiographic Facility Refurbishment completed at U1A tunnel in Nevada NNSS meeting Level 2 milestone (P-23 Highlights 6/10/12)

A moratorium was placed on U.S. underground nuclear testing in 1992. In response, the Stockpile Stewardship Program was created to maintain readiness of the existing nuclear inventory through several efforts such as computer modeling, material analysis, and subcritical nuclear experiments (SCEs). As in the underground test era, the Nevada National Security Site (NNSS), formerly the Nevada Test Site, provides a safe and secure environment for SCEs by the nature of its isolated and secure facilities. A major tool for SCE diagnosis installed in the 05 drift laboratory is a high energy x-ray source used for time resolved imaging. This tool consists of two identical sources (Cygnus 1 and Cygnus 2) and is called the Cygnus Dual Beam Radiographic Facility (Figs. 2-6). Each Cygnus machine has 5 major elements: Marx Generator, Pulse Forming Line (PFL), Coaxial Transmission Line (CTL), 3-cell Inductive Voltage Adder (IVA), and Rod Pinch Diode. Each machine is independently triggered and may be fired in separate tests (staggered mode), or in a single test where there is submicrosecond separation between the pulses (dual mode). Cygnus must operate as a single shot machine since on each pulse the diode electrodes are destroyed. The diode is vented to atmosphere, cleaned, and new electrodes are inserted for each shot. There is normally two shots per day on each machine. Since its installation in 2003, Cygnus has participated in: 4 Subcritical Experiments (Armando, Bacchus, Barolo A, and Barolo B), a 12 shot plutonium physics series (Thermos), and 2 plutonium step wedge calibration series (2005, 2011), resulting in well over 1000 shots. Currently the Facility is in preparation for 2 SCEs scheduled for this calendar year - Castor and Pollux. Cygnus has performed well during 8 years of operations at NNSS. Many improvements in operations and performance have been implemented during this time. Throughout its service at U1a, major maintenance and replacement of many hardware items were delayed due to programmatic requirements. It is anticipated that Cygnus will be in service at U1a for another 5 years. With this assumption, it was realized that significant resources and effort should be allotted to bring the hardware back to its original condition, or even to improve elements when appropriate. The Cygnus Refurbishment and Enhancement Project started in April, 2011 with the intent to encompass a major overhaul of Cygnus.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of emittance at low energy

Ideally, experimental measurements of all beam parameters should be made at the exit of the injector. This has not been possible on DARHT Axis-II for various practical reasons. In particular, the emittance has not been measured there. This note reviews the methods we have used for emittance measurements on the linear induction accelerator (LIA) at low-energy (< 10 MeV). It includes a discussion of some of the issues associated with making those measurements on a beam from the injector. A successful plan for emittance measurements at any energy should incorporate measures to deal with these issues. To begin with, it should be recognized that emittance measurements at the injector are not critical for beam physics in the accelerator. The emittance at the injector has very little effect on accelerator beam dynamics except for an increase in size near the end, where the beam becomes emittance dominated. Therefore, imperfect knowledge has little effect on the design and implementation of a tune. This point is illustrated in Fig. 1, which shows beam envelope calculations for our present tune over a wide range of emittances. Compare this with using the wrong diode voltage in the tune design. Figure 2 shows the effect on the beam envelope of a 2% error in the measurement of diode voltage. Therefore, a few years ago, when we made plans for beam measurements at the diode while we were upgrading the injector cells, our highest priority was on magnetic spectrometer measurements of energy. These measurements were to be used to cross calibrate the diode-voltage monitor, so that accurate diode voltage measurements could be made on every shot after the spectrometer was removed. If emittance measurements at the injector are required, then three widely used methods should be considered. These are focusing magnet scans, the use of an emittance mask (pepper pot), and optical transition radiation (OTR). We have used all three of these on our accelerators. These are invasive methods. There are noninvasive methods that we have not yet used. For example, under some conditions the beam size obtained with diamagnetic loops can be used in conjunction with the envelope equation to infer emittance. To date our diamagnetic loop data has not been of sufficient quality to do this. Another technique is to measure the beam-distribution quadrupole moment with BPMs dispersed in a quadrupole magnet lattice. Our BPMs have this capability, but the only quad lattice is in the downstream transport (DST), so this method is deferred until we operate the DST. All three methods reviewed here are invasive, and require the insertion of a target into the beam. Therefore, there is always the accompanying risk of inadvertent destruction of the target, and scattering of target material throughout the accelerator or injector. The target damage mechanism is target heating to a temperature hot enough to evolve gas, which is impact ionized by the beam, which is then ion focused to a small enough spot for the energy density to damage the target material, often destructively. Target heating is directly proportional to beam current density and pulse length. Therefore, the key to minimizing risk of target damage is to design for a large beam at the target, low current from the diode, and the shortest possible current pulse. The large-beam requirement compromises emittance measurements with OTR or focal scans, but not with the pepper pot technique. Finally, to ensure a short pulse even if the crowbar fails, the Marx generator should be reconfigured to produce the shortest possible pulse.

43 PARTICLE ACCELERATORS↗