Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mask”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Prediction and Evaluation of the Image of the WFIRST Coronagraph Pupil at the Shaped-Pupil Mask

To create a high contrast field of view with a shaped pupil coronagraph (SPC), the telescope pupil is imaged onto the shaped pupil mask, the shaped pupil mask is designed and fabricated through a design optimization based on a given pupil wavefront, and deformable mirrors (DM) in the coronagraph are modulated according to a nonlinear optimization procedure. Both the mask design optimization and the DM optimization require accurate knowledge of the image of the pupil at the shaped pupil plane for the calculation of Jacobians, and the evaluation of alignment tolerances. The shaped pupil coronagraphs demonstrated in the high contrast imaging testbed (HCIT) at JPL has heretofore assumed perfect imaging of the pupil onto the shaped pupil mask. Similarly, the design and performance modeling of the WFIRST CGI instrument makes the same assumption. In this paper we estimate and compare the image of the pupil mask at the shaped pupil plane in the case of the coronagraph testbed, and the image of the telescope pupil at the shaped pupil plane for the WFIRST CGI instrument. The estimated pupil images include field curvature and aberrations resulting from the layout of the parabolic mirror imaging system, which is optimized for the source image, not the image of the pupil. We also show the results of direct measurement of the image of the pupil mask at the shaped pupil plane in the coronagraph testbed.

Crowther, Blake↗

Initial Laboratory Demonstration of Multi-Star Wavefront Control at the Occulting Mask Coronagraph Testbed

Online Abstract: A majority of Sun-like stars, such as the A and B components of Alpha Centauri, have at least one stellar companion that can introduce additional noise into the field of view of any high-contrast imaging instrument. Multi-Star Wavefront Control (MSWC) is a wavefront-control technique that removes stellar leakage from both stellar components, enabling direct imaging of planets in many binary star systems. We present the latest experimental and modeling results obtained with MSWC as part of the technology development effort focusing on demonstrations conducted on the Occulting Mask Coronagraph (OMC) testbed at JPL. OMC has a layout similar to the Roman Space Telescope coronagraph instrument (CGI), and we used a MSWC mask similar to the one that was contributed to the Roman CGI. Our results represent the first demonstrations of this technique on the OMC testbed, with the ultimate goal of demonstrating full MSWC with validated models at contrast levels relevant to Roman CGI. Technical Review Abstract: A majority of Sun-like stars have at least one stellar companion that can introduce additional noise into the field of view of any high-contrast imaging instrument, limiting the achievable contrast. These include high-quality target stars such as the A and B components of Alpha Centauri, our nearest stellar neighbor. Enabling direct imaging of binary stars has the potential to increase the scientific yield for coronagraphic instruments planned on NASA's future space missions including the Roman Space Telescope and the next IR/O/UV Flagship recommended by Astro2020. Multi-Star Wavefront Control (MSWC) is a wavefront-control technique that simultaneously removes the (mutually incoherent) stellar leakage from both stellar components, enabling direct imaging of planets in many binary star systems. MSWC is an algorithmic technique and can be used with existing wavefront control systems on coronagraphic instruments (as well as starshades if a deformable mirror is available in the optical path). We summarize the latest experimental and numerical results obtained with MSWC as part of the technology development effort to demonstrate compatibility with existing high-contrast imaging platforms for this technique. The Super-Nyquist regime of MSWC was tested in vacuum at JPL's High Contrast Imaging Testbed (HCIT) on the Decadal Survey Testbed (DST) reaching 8.6e-9 contrast in a 10% band. Recently, the Occulting Mask Coronagraph (OMC) testbed at JPL is being prepared for demonstrations of Multi-Star Wavefront Control. A shaped pupil mask similar to the contributed MSWC mask on the Roman Space Telescope's coronagraph instrument has been recently manufactured including matching Lyot and focal plane masks and being installed on the OMC testbed. The goal of this experiment is a demonstration of MSWC using validated models on a testbed configuration and at contrast levels relevant to the Roman coronagraphic instrument.

High-contrast imaging↗

Mask roughness induced LER control and mitigation: aberrations sensitivity study and alternate illumination scheme

Here we conduct a mask-roughness-induced line-edge-roughness (LER) aberrations sensitivity study both as a random distribution amongst the first 16 Fringe Zernikes (for overall aberration levels of 0.25, 0.50, and 0.75nm rms) as well as an individual aberrations sensitivity matrix over the first 37 Fringe Zernikes. Full 2D aerial image modeling for an imaging system with NA = 0.32 was done for both the 22-nm and 16-nm half-pitch nodes on a rough mask with a replicated surface roughness (RSR) of 100 pm and a correlation length of 32 nm at the nominal extreme-ultraviolet lithography (EUVL) wavelength of 13.5nm. As the ideal RSR value for commercialization of EUVL is 50 pm and under, and furthermore as has been shown elsewhere, a correlation length of 32 nm of roughness on the mask sits on the peak LER value for an NA = 0.32 imaging optic, these mask roughness values and consequently the aberration sensitivity study presented here, represent a worst-case scenario. The illumination conditions were chosen based on the possible candidates for the 22-nm and 16-nm half-pitch nodes, respectively. In the 22-nm case, a disk illumination setting of {sigma} = 0.50 was used, and for the 16-nm case, crosspole illumination with {sigma} = 0.10 at an optimum offset of dx = 0 and dy = .67 in sigma space. In examining how to mitigate mask roughness induced LER, we considered an alternate illumination scheme whereby a traditional dipole's angular spectrum is extended in the direction parallel to the line-and-space mask absorber pattern to represent a 'strip'. While this illumination surprisingly provides minimal improvement to the LER as compared to several alternate illumination schemes, the overall imaging quality in terms of image-log-slope (ILS) and contrast is improved.

36 MATERIALS SCIENCE↗

Mask defect verification using actinic inspection and defect mitigation technology

The availability of defect-free masks remains one of the key challenges for inserting extreme ultraviolet lithography (EUVL) into high volume manufacturing. The successful production of defect-free masks will depend on the timely development of defect inspection tools, including both mask blank inspection tools and absorber pattern inspection tools to meet the 22 nm half-pitch node. EUV mask blanks with embedded phase defects were inspected with a reticle actinic inspection tool (AIT) and the Lasertec M7360. The Lasertec M7360 is operated at SEMA TECH's Mask blank Development Center (MBDC) in Albany, with sensitivity to multilayer defects down to 40-45 nm, which is not likely sufficient for mask blank development below the 32 nm half-pitch node. Phase defect printability was simulated to calculate the required defect sensitivity for the next generation blank inspection tool to support reticle development for the sub-32 nm half-pitch technology node. This paper will also discuss the kind of infrastructure that will be required in the development and mass production stages.

36 MATERIALS SCIENCE↗

EUV mask surface cleaning effects on lithography process performance

The reflective, multilayer based, mask architectures for extreme ultraviolet (EUV) lithography are highly susceptible to surface oxidation and contamination. As a result, EUV masks are expected to undergo cleaning processes in order to maintain the lifetimes necessary for high volume manufacturing. For this study, the impact of repetitive cleaning of EUV masks on imaging performance was evaluated. Two, high quality industry standard, EUV masks are used for this study with one of the masks undergoing repeated cleaning and the other one kept as a reference. Lithographic performance, in terms of process window analysis and line edge roughness, was monitored after every two cleans and compared to the reference mask performance. After 8x clean, minimal degradation is observed. The cleaning cycles will be continued until significant loss imaging fidelity is found.

36 MATERIALS SCIENCE↗

Effective antiviral coatings for deactivating SARS-CoV-2 virus on N95 respirator masks or filters

The application of antiviral coatings to masks and respirators is a potential mitigating step toward reducing viral transmission during the SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2) pandemic. The use of appropriate masks, social distancing, and vaccines is the immediate solution for limiting the viral spread and protecting people from this virus. N95 respirator masks are effective in filtering the virus particles, but they cannot kill or deactivate the virus. We report a possible approach to deactivating SARS-CoV-2 by applying an antimicrobial coating (Goldshield 75) to masks and respirators, rendering them suitable for repeated use. Masks coated with Goldshield 75 demonstrated continuous inactivation of the Alpha and Beta variants of the SARS-CoV-2 over a 3-day period and no loss of inactivation when stored at temperatures at 50 °C.

36 MATERIALS SCIENCE↗

High Contrast Internal and External Coronagraph Masks Produced by Various Techniques

Masks for high contrast internal and external coronagraphic imaging require a variety of masks depending on different architectures to suppress star light. Various fabrication technologies are required to address a wide range of needs including gradient amplitude transmission, tunable phase profiles, ultra-low reflectivity, precise small scale features, and low-chromaticity. We present the approaches employed at JPL to produce pupil plane and image plane coronagraph masks, and lab-scale external occulter type masks by various techniques including electron beam, ion beam, deep reactive ion etching, and black silicon technologies with illustrative examples of each. Further development is in progress to produce circular masks of various kinds for obscured aperture telescopes.

Phase Induced Amplitude Apodization Complex Mask C↗

Charging Experiments and Filtration Testing on Facemask Materials: Towards Goals of Full Performance Restoration of Used N95 Masks and Enhancement of Common-Fabric Facemasks

Different techniques have been developed for sanitizing N95 masks while retaining whatever charge remains on them. However, these sanitizing methods do not address the fact that the electrical charge, filtration efficacy, and breathability of such masks may be expected to degrade during long-term use based on mechanisms known in the literature. In this study, approaches to electrically (re)charging facemask filter materials were explored in response to the COVID-19 induced shortage of N95 masks. The effort consisted of charging experiments followed by filtration testing conducted at the coupon level during a month-long period (May 2020). The main focus of the work was to develop a recharging technique which could eventually be adapted and used as part of a broader full-performance restoration process for used N95 masks, e.g., which might employ simple washing by alcohol or soapy water as a preceding step for sanitization and declogging. Most tested coupons were therefore nonwoven meltblown fibrous polypropylene (PP) filter media extracted from decades old N95 masks. Keeping in mind commonly used cloth facemasks, limited trials were also performed with some commercially available fabrics. Charging was done at elevated temperature and was followed by cooling to freeze in the applied charges produced from corona discharges using different electrode configurations and parameter combinations, or from triboelectric rubbing. Charging was also focused on using potentially scalable equipment, e.g., Van de Graaff generators or consumer ionic hair products. Some degree of success was achieved with one of the fabrics and the PP filter media which was first purposefully discharged to have typical filtration efficiency (FE) of ~35%. Numerous attempts at corona charging discharged media resulted in filtration efficiency (FE) ≥ 80 – 85%. Some measure of charge robustness was also established via stable performance during loading testing. However, results where FE ≥ 90% were not reliably repeatable and no results met the FE ≥ 95% goal due to shortcomings of the charging process. The best three trials for PP media statistically met the FE ≥ 90% criteria, amounted to a small percentage of the trials relying on an ionic hair dryer, and are attributed to good embedding of charges via aerodynamic force. Triboelectric charging significantly enhanced the viability of one of the polyester fabrics –measured FE increased from 19% up to 46% while maintaining a reasonably low pressure drop.

N95↗

Development of a Consistent Cross-Platform GEO-Satellite Cloud Mask to Support CERES

Geostationary satellites provide continuous cloud and meteorological observations over a fixed portion of the Earth’s surface, allowing them to monitor the movement of storm systems and their diurnal variation. For climate studies, geostationary observations provide valuable insight of cloud formation and evolution and how they influence the Earth’s radiation budget. The Geo-Satellite Edition 4 cloud mask (GEO Ed4) is used operationally in NASA’s Cloud and Earth’s Radiant Energy System (CERES) project to help account for diurnal variations in cloudiness on Earth’s radiation budget. The Ed4 cloud mask was applied to imager data on MSG (MeteoSat Second Generation), Himawari, GOES-West, and GOES-East satellites using as much spectral information as possible. That approach led to some discontinuities when a more modern satellite replaced an older satellite with less spectral information. A different strategy is being investigated for the CERES GEO Ed5 cloud mask that only uses spectral channels common on every satellite. Thus, a 3-channel (0.6, 3.9, 11 µm) algorithm for daytime cloud detection, and a 2-channels (3.9 and 11 µm) algorithm for nighttime cloud detection have been implemented and tested for Ed5. The goal of Ed5 cloud mask is to achieve global cloud amount consistency across five geo-satellites, and a smooth transition from an old satellite to a new satellite over each geo-location. This paper compares cloud mask results between Ed4 and a preliminary Ed5 version over the GOES-East region, using GOES-8, GOES-13, and GOES-16 satellites, each with a different spectral channel complement. Instantaneous and monthly regional mean inter-comparisons are performed and evaluated with CALIPSO cloud products to assess the accuracy and consistency of the Ed5 approach relative to that taken in Ed4. Results will be presented and discussed at the conference.

clouds↗

Progress Towards a Common CERES Cloud Mask Algorithm for MODIS and VIIRS: Evaluation using CALIOP Data

For over two decades The Clouds and the Earth’s Radiant Energy System (CERES) project has endeavored to produce a long-term global climate data record for detecting changes in the Earth’s radiation budget and to improve understanding of how clouds contribute to those changes. CERES incorporates cloud information derived from passive narrowband satellite imaging radiometers, and over the course of the project different instruments have contributed to this effort, namely the Moderate Resolution Imaging Spectroradiometer (MODIS) and the Visible Infrared Imaging Radiometer Suite (VIIRS).Cloud properties have been derived from MODIS on the Aqua satellite for CERES since 2002,and VIIRS on the NOAA-20 satellite launched in 2017 will continue the cloud record once Aqua-MODIS reaches the end of its operational lifetime. However, MODIS and VIIRS have different spectral capabilities and characteristics which complicates our ability to seamlessly transition the record from MODIS to VIIRS. This study evaluates some of the recent algorithm modifications incorporated by the CERES Cloud Working Group towards developing a unified cloud mask algorithm for MODIS and VIIRS that utilizes a set of spectral bands common to both instruments. Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) data products are used to evaluate MODIS and VIIRS regional cloud fraction estimates and identify areas where improvements can be made. The cloud mask algorithm relies on computed estimates of cloud-free top-of-atmosphere radiances to differentiate cloudy and cloud-free imager pixels. The unified cloud mask algorithm currently under development uses a reduced number of spectral bands common to both MODIS and VIIRS and so relies on the accuracy of these simulated cloud-free radiances more heavily than predecessor algorithms, i.e., the CERES Edition 4 cloud mask, which use as much spectral information as available on each imager with less consideration for cross-platform consistency. Our validation strategy using CALIOP data is also described. The CALIOP observations are critical for assessing cloud detection accuracies and for independently confirming cloud-free conditions which enables a more robust evaluation of the simulated cloud-free radiances for biases due to factors such as view angle and the spectral dependence of water vapor absorption. These effects are known to differ for the two satellite instruments. Comparisons of MODIS and VIIRS cloud fractions are presented in context with estimates from CALIOP and from the CERES Edition 4 cloud mask algorithm to gauge current progress in developing accurate and consistent MODIS and VIIRS cloud properties for CERES.

CERES↗

Toward Physics-informed Neural Networks for 3D Multi-layer Cloud Mask Reconstruction

Three-dimensional (3D) cloud retrievals are critical for understanding their impact on climate and other applications such as aviation safety, weather prediction, and remote sensing. However, obtaining high-resolution and accurate vertical representation of clouds remains unsolved due to the limitations imposed by satellite instrumentation, viewing conditions, and the complexity of cloud dynamics. Cloud masks are essential for comprehending various cloud vertical properties, but deriving accurate 3D cloud masks from 2D satellite imagery data is a challenging task. To tackle these challenges, we introduce a physics-informed loss function for training deep learning models that can extend 2D cloud images into 3D cloud masks. The proposed loss, called CloudMask Loss, is composed of two domain knowledge-informed loss terms: one for evaluating cloud position and thickness, and the other for measuring the number of layers. By combining these loss terms, we improve the trainability of the deep learning models for more accurate and meaningful results. We apply the proposed loss function to different neural networks and demonstrate significant improvements in multi-layer cloud mask reconstruction. Utilizing the same neural network architecture, our proposed loss outperforms standard binary crossentropy loss in terms of multi-layer cloud classification accuracy, number of layers accuracy, and thickness mean absolute error (MAE). The proposed loss function can be readily integrated into various neural network architectures, resulting in substantial performance gains in 3D cloud mask generation.

multi-layer clouds↗

Using High-Resolution NSRDB Data to Evaluate Cloud Mask Forecast from WRF-Solar EPS

Validating spatiotemporal distributions of cloud forecasts using numerical weather prediction (NWP) models is difficult as this requires high-quality cloud-property at significantly high spatial and temporal resolution over extended periods of time. Observations of cloud properties, such as cloud mask, cloud optical thickness, and cloud type, are vital for assessing the capability of NWP models to forecast various types of clouds. Using the National Solar Radiation Database (NSRDB), this research evaluates ensemble cloud-mask predictions from the WRF-Solar ensemble prediction system (WRF-Solar EPS). From the WRF-Solar EPS, day-ahead solar forecasts for the contiguous United States (CONUS) for 2018 are simulated. Given the NSRDB data is accessible at a resolution of 2 km, we can calculate the cloud fraction across the 9-km grid of WRF-Solar EPS. This allows us to spatially assess the cloud-mask forecasts using two methods against the high-resolution NSRDB: (a) considering all 2-km NSRDB clouds in the forecast domain (EMAll), and (b) using a minimum cloud fraction threshold of 50% to designate a pixel as cloudy (EMP50). The low-resolution cloud masks from WRF-Solar EPS are evaluated directly against the cloud-resolving scale gridded observations from NSRDB using EMAll. With EMP50, we presume that scenes with less than 50% cloud cover from the 2-km NSRDB are clear. Thus, this assessment approach allows for a fair comparison with WRF-Solar EPS resolved to a 9-km grid. A method of point-by-point verification is used to evaluate dichotomous (yes/no) cloud mask predictions against the NSRDB. For each pixel of model extent, cloud frequency and traditional metrics (e.g., probability of detection, false alarm rate, and hit rate, etc.) are computed and compared with satellite-derived data sets. Mismatched cloud frequency (MCF) is computed to measure the present capability of WRF-Solar EPS in representing various types of clouds, which are categorized using three levels of cloud top height (CTH) and cloud optical depth (COD) across entire CONUS. Preliminary results show that the WRF-Solar EPS provides MCF values ranging from 9% to 46%, 16% to 33%, and 8% to 27% for low-level, middle-level, and high-level clouds, respectively, for three CTHs. The model produces MCFs ranging from 27% to 46%, 13% to 34%, and 8% to 19% for thin, medium-thickness, and thick clouds, respectively, for three CODs. The presentation will include a detailed description of the current outcomes as well as potential future extensions. The evaluation approach established in this study is readily extensible to the evaluation of cloud predictions from different ensemble NWP models. In addition, the findings of the suggested evaluation technique aid in identifying model weaknesses and will ultimately lead to advances in WRF-Solar EPS's skill in predicting clouds and solar irradiance.

cloud mask forecast↗

Can disposable masks be worn more than once?

Disposable facemasks are a primary tool to prevent the transmission of SARS-COV-2 during the COVID-19 pandemic. However, plastic waste generated from their disposal represents a significant environmental problem that can be reduced by maximizing the service life of disposable masks. We evaluated the effect of repeated wearing on the fitted filtration efficiency (FFE) of N95, KF94, KN95, and procedure/surgical masks. The FFEs of masks were compared following extended wearing with and without washing. Results reveal that most disposable facemasks can retain a high level of their baseline FFE after extended wearing, even after 40 h of wearing. Laundering disposable masks degraded FFE in some instances. We conclude that the durability of disposable facemask performance is considerably longer than their intended single use indication, suggesting that reusing disposable masks is a safe means of reducing plastic waste in the environment.

54 ENVIRONMENTAL SCIENCES↗

Inter- and Intrafraction Patient Positioning Uncertainties for Intracranial Radiotherapy: A Study of Four Frameless, Thermoplastic Mask-Based Immobilization Strategies Using Daily Cone-Beam CT

Purpose: To determine whether frameless thermoplastic mask-based immobilization is adequate for image-guided cranial radiosurgery. Methods and Materials: Cone-beam CT localization data from patients with intracranial tumors were studied using daily pre- and posttreatment scans. The systems studied were (1) Type-S IMRT (head only) mask (Civco) with head cushion; (2) Uni-Frame mask (Civco) with head cushion, coupled with a BlueBag body immobilizer (Medical Intelligence); (3) Type-S head and shoulder mask with head and shoulder cushion (Civco); (4) same as previous, coupled with a mouthpiece. The comparative metrics were translational shift magnitude and average rotation angle; systematic inter-, random inter-, and random intrafraction positioning error was computed. For strategies 1-4, respectively, the analysis for interfraction variability included data from 20, 9, 81, and 11 patients, whereas that for intrafraction variability included a subset of 7, 9, 16, and 8 patients. The results were compared for statistical significance using an analysis of variance test. Results: Immobilization system 4 provided the best overall accuracy and stability. The mean interfraction translational shifts ({+-} SD) were 2.3 ({+-} 1.4), 2.2 ({+-} 1.1), 2.7 ({+-} 1.5), and 2.1 ({+-} 1.0) mm whereas intrafraction motion was 1.1 ({+-} 1.2), 1.1 ({+-} 1.1), 0.7 ({+-} 0.9), and 0.7 ({+-} 0.8) mm for devices 1-4, respectively. No significant correlation between intrafraction motion and treatment time was evident, although intrafraction motion was not purely random. Conclusions: We find that all frameless thermoplastic mask systems studied are viable solutions for image-guided intracranial radiosurgery. With daily pretreatment corrections, symmetric PTV margins of 1 mm would likely be adequate if ideal radiation planning and targeting systems were available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhancing Nanoparticle Detection in Interferometric Scattering (iSCAT) Microscopy Using a Mask R-CNN

Interferometric scattering microscopy (iSCAT) is a label-free optical microscopy technique that enables imaging of individual nano-objects such as nanoparticles, viruses, and proteins. Essential to this technique is the suppression of background scattering and identification of signals from nano-objects. In the presence of substrates with high roughness, scattering heterogeneities in the background, when coupled with tiny stage movements, cause features in the background to be manifested in background-suppressed iSCAT images. Traditional computer vision algorithms detect these background features as particles, limiting the accuracy of object detection in iSCAT experiments. Here, in this paper, we present a pathway to improve particle detection in such situations using supervised machine learning via a mask region-based convolutional neural network (mask R-CNN). Using a model iSCAT experiment of 19.2 nm gold nanoparticles adsorbing to a rough layer-by-layer polyelectrolyte film, we develop a method to generate labeled datasets using experimental background images and simulated particle signals and train the mask R-CNN using limited computational resources via transfer learning. We then compare the performance of the mask R-CNN trained with and without inclusion of experimental backgrounds in the dataset against that of a traditional computer vision object detection algorithm, Haar-like feature detection, by analyzing data from the model experiment. Results demonstrate that including representative backgrounds in training datasets improved the mask R-CNN in differentiating between background and particle signals and elevated performance by markedly reducing false positives. The methodology for creating a labeled dataset with representative experimental backgrounds and simulated signals facilitates the application of machine learning in iSCAT experiments with strong background scattering and thus provides a useful workflow for future researchers to improve their image processing capabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selective-area growth of GaN nanowires on SiO{sub 2}-masked Si (111) substrates by molecular beam epitaxy

We analyze a method to selectively grow straight, vertical gallium nitride nanowires by plasma-assisted molecular beam epitaxy (MBE) at sites specified by a silicon oxide mask, which is thermally grown on silicon (111) substrates and patterned by electron-beam lithography and reactive-ion etching. The investigated method requires only one single molecular beam epitaxy MBE growth process, i.e., the SiO{sub 2} mask is formed on silicon instead of on a previously grown GaN or AlN buffer layer. We present a systematic and analytical study involving various mask patterns, characterization by scanning electron microscopy, transmission electron microscopy, and photoluminescence spectroscopy, as well as numerical simulations, to evaluate how the dimensions (window diameter and spacing) of the mask affect the distribution of the nanowires, their morphology, and alignment, as well as their photonic properties. Capabilities and limitations for this method of selective-area growth of nanowires have been identified. A window diameter less than 50 nm and a window spacing larger than 500 nm can provide single nanowire nucleation in nearly all mask windows. The results are consistent with a Ga diffusion length on the silicon dioxide surface in the order of approximately 1 μm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ON-SKY DEMONSTRATION OF A LINEAR BAND-LIMITED MASK WITH APPLICATION TO VISUAL BINARY STARS

We have designed and built the first band-limited coronagraphic mask used for ground-based high-contrast imaging observations. The mask resides in the focal plane of the near-infrared camera PHARO at the Palomar Hale telescope and receives a well-corrected beam from an extreme adaptive optics system. Its performance onsky with single stars is comparable to current state-of-the-art instruments: contrast levels of 10 5 or better at 0. 8 in Ks after post-processing, depending on how well non-common-path errors are calibrated. However, given the mask s linear geometry, we are able to conduct additional unique science observations. Since the mask does not suffer from pointing errors down its long axis, it can suppress the light from two different stars simultaneously, such as the individual components of a spatially resolved binary star system, and search for faint tertiary companions. In this paper, we present the design of the mask, the science motivation for targeting binary stars, and our preliminary results, including the detection of a candidate M-dwarf tertiary companion orbiting the visual binary star HIP 48337, which we are continuing to monitor with astrometry to determine its association.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A CLOSE COMPANION SEARCH AROUND L DWARFS USING APERTURE MASKING INTERFEROMETRY AND PALOMAR LASER GUIDE STAR ADAPTIVE OPTICS

We present a close companion search around 16 known early L dwarfs using aperture masking interferometry with Palomar laser guide star adaptive optics (LGS AO). The use of aperture masking allows the detection of close binaries, corresponding to projected physical separations of 0.6-10.0 AU for the targets of our survey. This survey achieved median contrast limits of {Delta}K {approx} 2.3 for separations between 1.2 {lambda}/D-4{lambda}/D and {Delta}K {approx} 1.4 at 2/3 {lambda}/D. We present four candidate binaries detected with moderate-to-high confidence (90%-98%). Two have projected physical separations less than 1.5 AU. This may indicate that tight-separation binaries contribute more significantly to the binary fraction than currently assumed, consistent with spectroscopic and photometric overluminosity studies. Ten targets of this survey have previously been observed with the Hubble Space Telescope as part of companion searches. We use the increased resolution of aperture masking to search for close or dim companions that would be obscured by full aperture imaging, finding two candidate binaries. This survey is the first application of aperture masking with LGS AO at Palomar. Several new techniques for the analysis of aperture masking data in the low signal-to-noise regime are explored.

79 ASTRONOMY AND ASTROPHYSICS↗