Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measured Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Development of an on-line parameter estimation system using the discrete modal filter

Ongoing development of an automated system for monitoring the frequency and damping of time varying structural systems is discussed. A spatial filtering technique called the discrete modal filter is used to uncouple multiple response measurements into modal coordinate responses. Since the modal coordinate responses are the responses of single-degree-of-freedom systems, the frequency and damping may be accurately estimated with short data records. An on-line monitoring system is discussed which may be useful in a variety of applications. The focus in this paper is on the application to aircraft flight flutter testing.

Shelley, S. J.↗

2.4 Micron Cutoff AlGaAsSb/InGaAsSb Phototransistors for Shortwave IR Applications

Shortwave infrared detectors are critical for several applications including remote sensing and optical communications. Several detectors are commercially available for this wavelength range, but they lack sufficient gain, which limits their detectivity. The characterization results of an AlGaAsSb/InGaAsSb phototransistor for shortwave IR application are reported. The phototransistor is grown using molecular beam epitaxy technique. Spectral response measurements showed a uniform responsivity between 1.2 and 2.4 micron region with a mean value of 1000 A/W. A maximum detectivity of 3.4 X 10(exp 11) cmHz1/2/W was obtained at 2 micron at -20 C and 1.3 V.

Refaat, Tamer F.↗

Method of Detecting System Function by Measuring Frequency Response

Real time battery impedance spectrum is acquired using one time record, Compensated Synchronous Detection (CSD). This parallel method enables battery diagnostics. The excitation current to a test battery is a sum of equal amplitude sin waves of a few frequencies spread over range of interest. The time profile of this signal has duration that is a few periods of the lowest frequency. The voltage response of the battery, average deleted, is the impedance of the battery in the time domain. Since the excitation frequencies are known, synchronous detection processes the time record and each component, both magnitude and phase, is obtained. For compensation, the components, except the one of interest, are reassembled in the time domain. The resulting signal is subtracted from the original signal and the component of interest is synchronously detected. This process is repeated for each component.

Morrison, John L.↗

Hybrid FEA/SEA Assessment for an Orthogrid Cylindrical Panel Section and Periodic Subsystem Modeling Evaluation

In the lower frequency range, where particular boundary conditions can make a significant difference to panel response characteristics Statistical Energy Analysis (SEA) has never been the analytical tool of choice. In addition to boundary condition effects, SEA is not well suited in frequency bands where no modes or less than a few modes exist. The advent of the Hybrid Module has enabled integration of Finite Element Analysis to expand and enhance the capability for response calculations within VA One into the lower frequency range. Exploration of several additional modeling approaches was completed for the cylindrical orthogrid panel test article that was examined in Reference 1. Comparison of the new analytical response predictions with the measured response data from ground test and the pure SEA results from the reference will be presented. One approach that is considered promising is the periodic subsystem capability. Initially, a detailed FEM of just one region of the test article is defined. After evaluating this small region using symmetric boundary conditions, the FEM may be expanded to determine the properties of the entire system using similar connected regions that map over the entire test article. Another approach is the direct use of a very detailed finite element model of the entire panel, explicitly modeling pocket and rib details of the structure. A third approach is to approximate localized structure geometry details with a smeared property generalization using a PCOMP (NASTRAN card used to define layered composite structures) to define skin layer and ribbed layer for the orthogrid panel. The authors expect to demonstrate that the integrated Hybrid/FEM approach increases confidence in response prediction in the lower frequency range (for example from 20-300 Hz for the test article under consideration). In addition the strength and weakness of each additional approach will be highlighted and compared to those reported with those reported in an earlier paper

Smith, Andrew M.↗

Method of detecting system function by measuring frequency response

Real-time battery impedance spectrum is acquired using a one-time record. Fast Summation Transformation (FST) is a parallel method of acquiring a real-time battery impedance spectrum using a one-time record that enables battery diagnostics. An excitation current to a battery is a sum of equal amplitude sine waves of frequencies that are octave harmonics spread over a range of interest. A sample frequency is also octave and harmonically related to all frequencies in the sum. The time profile of this signal has a duration that is a few periods of the lowest frequency. The voltage response of the battery, average deleted, is the impedance of the battery in the time domain. Since the excitation frequencies are known and octave and harmonically related, a simple algorithm, FST, processes the time record by rectifying relative to the sine and cosine of each frequency. Another algorithm yields real and imaginary components for each frequency.

Morrison, John L.↗

A Cavity-Enhanced UV Absorption Instrument for High-Precision, Fast-Time-Response Ozone Measurements

The NASA Rapid Ozone Experiment (ROZE) is a broadbandcavity-enhanced UV absorption instrument for the detection of in situozone (O3).ROZE uses an incoherent LED light source coupled to a high-finesse optical cavity to achieve an effective pathlength of ~104 m. Due to its high-sensitivity and smalloptical cell volume, ROZE demonstratesa 1𝜎precision of 80 pptv (0.1 s) and 31 pptv (1 s), as well as an 𝑒-fold timeresponseof 50 ms. ROZE can be operated in a range of field environments, including low-and high-altitude research aircraft,and is particularly suited toO3vertical flux measurements usingthe eddy covariance technique.ROZE was successfully integrated aboard the NASA DC-8 aircraft during July–September2019and validated against a well-established chemiluminescence measurement of O3.Aflight within the marine boundary layer also demonstrated flux measurement capabilities, and we observeda mean O3deposition velocityof 0.029 ± 0.005 cm s–1to the ocean surface.The performance characteristics detailed below make ROZE a robust, versatile instrument for fieldmeasurements of O3.

Rapid Ozone Experiment (ROZE)↗

Edge Response and NIIRS Estimates for Commercial Remote Sensing Satellites

Spatial resolution of panchromatic imagery from commercial remote sensing satellites was characterized based on edge response measurements using edge targets and the tilted-edge technique. Relative Edge Response (RER) was estimated as a geometric mean of normalized edge response differences measured in two directions of image pixels at points distanced from the edge by -0.5 and 0.5 of ground sample distance. RER is one of the engineering parameters used in the General Image Quality Equation to provide predictions of imaging system performance expressed in terms of the National Imagery Interpretability Rating Scale (NIIRS). By assuming a plausible range of signal-to-noise ratio and assessing the effects of Modulation Transfer Function compensation, the NIIRS estimates were made and then compared with vendor-provided values and evaluations conducted by the National Geospatial-Intelligence Agency.

Blonski, Slawomir↗

System Characterization Results for the QuickBird Sensor

An overall system characterization was performed on several DigitalGlobe' QuickBird image products by the NASA Applied Research & Technology Project Office (formerly the Applied Sciences Directorate) at the John C. Stennis Space Center. This system characterization incorporated geopositional accuracy assessments, a spatial resolution assessment, and a radiometric calibration assessment. Geopositional assessments of standard georeferenced multispectral products were obtained using an array of accurately surveyed geodetic targets evenly spaced throughout a scene. Geopositional accuracy was calculated in terms of circular error. Spatial resolution of QuickBird panchromatic imagery was characterized based on edge response measurements using edge targets and the tilted-edge technique. Relative edge response was estimated as a geometric mean of normalized edge response differences measured in two directions of image pixels at points distanced from the edge by -0.5 and 0.5 of ground sample distance. A reflectance-based vicarious calibration approach, based on ground-based measurements and radiative transfer calculations, was used to estimate at-sensor radiance. These values were compared to those measured by the sensor to determine the sensor's radiometric accuracy. All imagery analyzed was acquired between fall 2005 and spring 2006. These characterization results were compared to previous years' results to identify any temporal drifts or trends.

Holekamp, Kara↗

Forced guidance and distribution of practice in sequential information processing.

Distribution of practice and forced guidance were used in a sequential information-processing task in an attempt to increase the capacity of human information-processing mechanisms. A reaction time index of the psychological refractory period was used as the response measure. Massing of practice lengthened response times while forced guidance shortened them. Interpretation was in terms of load reduction upon the response-selection stage of the information-processing system.-

Decker, L. R.↗

Ride quality research techniques: Section on scaling techniques

Scaling techniques appropriate for the measurement of ride quality subjective responses are evaluated. The major focal points of interest are summarized in succeeding paragraphs as follow: (1) scope of scaling, (2) goal of scaling, (3) category scales; including polarity, scalar points, and whether the scale is discrete or continuous in nature, (4) need and use of adjectives and/or adverbs, (5) role and use of magnitude estimation, (6) multiple response measures; and (7) related topics.

Source record↗

Material growth and characterization directed toward improving III-V heterojunction solar cells

In addition to the existing materials growth laboratory, the photolithographic facility and the device testing facility were completed. The majority of equipment for data acquisition, solar cell testing, materials growth and device characterization were received and are being put into operation. In the research part of the program, GaAs and GaA1As layers were grown reproducibly on GaAs substrates. These grown layers were characterized as to surface morphology, thickness and thickness uniformity. The liquid phase epitaxial growth process was used to fabricate p-n junctions in Ga(1-x)A1(x)As. Sequential deposition of two alloy layers was accomplished and detailed analysis of the effect of substrate quality and dopant on the GaA1As layer quality is presented. Finally, solar cell structures were formed by growing a thin p-GaA1As layer upon an epitaxial n-GaA1As layer. The energy gap corresponding to the long wavelength cutoff of the spectral response characteristic was 1.51-1.63 eV. Theoretical calculations of the spectral response were matched to the measured response.

Stefanakos, E. K.↗

Nonstationary Transient Vibroacoustic Response of a Beam Structure

This study consists of an investigation into the nonstationary transient response of the Verification Test Article (VETA) when subjected to random acoustic excitation. The goal is to assess excitation models that can be used in the design of structures and equipment when knowledge of the structure and the excitation is limited. The VETA is an instrumented cantilever beam that was exposed to acoustic loading during five Space Shuttle launches. The VETA analytical structural model response is estimated using the direct averaged power spectral density and the normalized pressure spectra methods. The estimated responses are compared to the measured response of the VETA. These comparisons are discussed with a focus on prediction conservatism and current design practice.

Caimi, R. E.↗

Evaluation of a Multi-Parameter Sensor for Automated, Continuous Cell Culture Monitoring in Bioreactors

Compact and automated sensors are desired for assessing the health of cell cultures in biotechnology experiments in microgravity. Measurement of cell culture medium allows for the optirn.jzation of culture conditions on orbit to maximize cell growth and minimize unnecessary exchange of medium. While several discrete sensors exist to measure culture health, a multi-parameter sensor would simplify the experimental apparatus. One such sensor, the Paratrend 7, consists of three optical fibers for measuring pH, dissolved oxygen (p02), dissolved carbon dioxide (pC02) , and a thermocouple to measure temperature. The sensor bundle was designed for intra-arterial placement in clinical patients, and potentially can be used in NASA's Space Shuttle and International Space Station biotechnology program bioreactors. Methods: A Paratrend 7 sensor was placed at the outlet of a rotating-wall perfused vessel bioreactor system inoculated with BHK-21 (baby hamster kidney) cells. Cell culture medium (GTSF-2, composed of 40% minimum essential medium, 60% L-15 Leibovitz medium) was manually measured using a bench top blood gas analyzer (BGA, Ciba-Corning). Results: A Paratrend 7 sensor was used over a long-term (>120 day) cell culture experiment. The sensor was able to track changes in cell medium pH, p02, and pC02 due to the consumption of nutrients by the BHK-21. When compared to manually obtained BGA measurements, the sensor had good agreement for pH, p02, and pC02 with bias [and precision] of 0.02 [0.15], 1 mm Hg [18 mm Hg], and -4.0 mm Hg [8.0 mm Hg] respectively. The Paratrend oxygen sensor was recalibrated (offset) periodically due to drift. The bias for the raw (no offset or recalibration) oxygen measurements was 42 mm Hg [38 mm Hg]. The measured response (rise) time of the sensor was 20 +/- 4s for pH, 81 +/- 53s for pC02, 51 +/- 20s for p02. For long-term cell culture measurements, these response times are more than adequate. Based on these findings , the Paratrend sensor could offer automated, continuous monitoring of cell cultures with a temporal resolution of 1 minute, which is not attainable by sampling via handheld blood analyzer (i-STAT). Conclusion: The resulting bias and precision found in these cell culture-based studies is comparable to Paratrend sensor clinical results. Although the large error in p02 measurements (+/-18 mm Hg) may be acceptable for clinical applications, where Paratrend values are periodically adjusted to a BGA measurement, the O2 sensor in this bundle may not be reliable enough for the single-calibration requirement of sensors used in NASA's bioreactors. The pH and pC02 sensors in the bundle are reliable and stable over the measurement period, and can be used without recalibration to measure cell cultures in rn.jcrogravity biotechnology experiments. Future work will test additional Paratrend sensors to provide statistical assessment of sensor performance.

Pappas, D.↗

Extraction of longitudinal aerodynamic coefficients from forward-flight conditions of a tilt-wing V/STOL airplane

A parameter-estimation algorithm was used to extract the longitudinal aerodynamic derivatives from flight data for the XC-142A airplane in a cruise condition. The flight data were the response to a tail-plane doublet input. Results of this study showed that a set of derivatives were determined which yielded a calculated aircraft response in close agreement with the measured response. This calculated response was in much closer agreement with the flight data than the response obtained by using derivatives which were calculated from empirical methods. There were large differences between some of the important derivatives extracted from flight data and those calculated from empirical methods. The reasons for these differences were not identified.

Williams, J. L.↗

End-to-end test of the electron-proton spectrometer

A series of end-to-end tests were performed to demonstrate the proper functioning of the complete Electron-Proton Spectrometer (EPS). The purpose of the tests was to provide experimental verification of the design and to provide a complete functional performance check of the instrument from the excitation of the sensors to and including the data processor and equipment test set. Each of the channels of the EPS was exposed to a calibrated beam of energetic particles, and counts were accumulated for a predetermined period of time for each of several energies. The counts were related to the known flux of particles to give a monodirectional response function for each channel. The measured response function of the test unit was compared to the response function determined for the calibration sensors from the data taken from the calibration program.

Cash, B. L.↗

Response of the middle atmosphere to solar UV and dynamical perturbations

Recent studies of solar UV related changes of ozone and temperature have considerably improved the understanding of the solar UV and ozone relationship in the middle atmosphere on time scales of a solar rotation. These studies have shown that during periods of high solar activity, ozone in the upper stratosphere has a measurable response to changes in the solar UV flux in accordance with theoretical predictions. The problem of measuring solar response of the stratospheric ozone and temperature on time scales of a solar cycle is more difficult. In the altitude range of 2 mb, the model based calculations, based on plausible scenarios of solar UV variation, suggest a change of less than 4 percent in ozone mixing ratio and 1 to 2 K in temperature. The relative response was studied of the middle atmosphere to solar forcing at 155 and 27 day periods as indicated from the spectral analyses of a number of solar indices.

Chandra, S.↗