Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Integrated Decision Methodology for Final Disposal of Radioactive Sources

Radioactive sources are used throughout the world, and their beneficial uses are many. Sources are at the core of many applications in different branches of industry, medicine, agriculture and research. Sources are present in a very wide range of equipment that is used for, inter alia, cancer treatment, killing bacteria in food, sterilizing medical supplies, measuring instruments such as gauges used to measure soil moisture and soil density and many other components, irradiating seeds for enhancing food production, protecting buildings from lightning strikes, mapping underground sources of water, prospecting for oil and gas reserves, measuring density of soil for construction projects, or even detecting smoke. At their “cradle” and when in use, radioactive sources are usually properly managed and controlled. It is when a source has reached the end of its useful life when they are at a higher risk of being under inadequate control, poorly managed, or even becoming orphan. Sources that have reached the end of their useful life must be carefully and safely managed. The “grave” of disused sources needs a proper disposal process to prevent them from posing a potential threat to people or the environment. To protect the public and the environment from the potential hazards of ionizing radiation, and to prevent disused sources from becoming orphan, a “cradle-to-grave” control of radioactive sources is essential, as promoted by the Code of Conduct on the Safety and Security of Radioactive Sources. This approach requires a national policy and strategy, an adequate legal and regulatory framework, and adequate resources and infrastructure. Many IAEAMember States have expressed the need for effective solutions to this challenge. There is also a gap related to the life cycle costs of potential disposal practices. This paper proposes a multi-attribute decision making methodology to compare disposal options using both economic and non-economic criteria leading to a preferred option for disposal and a strategy for final disposal of disused radioactive sources that is specific and optimized for each IAEA Member State.

Beatty, Randy↗

Integration of the Two-Dimensional Power Spectral Density into Specifications for the X-ray Domain -- Problems and Opportunities

An implementation of the two-dimensional statistical scattering theory of Church and Takacs for the prediction of scattering from x-ray mirrors is presented with a graphical user interface. The process of this development has clarified several problems which are of significant interest to the synchrotron community. These problems have been addressed to some extent, for example, for large astronomical telescopes, and at the National Ignition Facility for normal incidence optics, but not in the synchrotron community for grazing incidence optics. Since it is based on the Power Spectral Density (PSD) to provide a description of the deviations from ideal shape of the surface, accurate prediction of the scattering requires an accurate estimation of the PSD. Specifically, the spatial frequency range of measurement must be the correct one for the geometry of use of the optic--including grazing incidence and coherence effects, and the modifications to the PSD of the Optical Transfer Functions (OTF) of the measuring instruments must be removed. A solution for removal of OTF effects has been presented previously, the Binary Pseudo-Random Grating. Typically, the frequency range of a single instrument does not cover the range of interest, requiring the stitching together of PSD estimations. This combination generates its own set of difficulties in two dimensions. Fitting smooth functions to two dimensional PSDs, particularly in the case of spatial non-isotropy of the surface, which is often the case for optics in synchrotron beam lines, can be difficult. The convenient, and physically accurate fractal for one dimension does not readily transfer to two dimensions. Finally, a completely statistical description of scattering must be integrated with a deterministic low spatial frequency component in order to completely model the intensity near the image. An outline for approaching these problems, and our proposed experimental program is given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Processing Methodology for Double Sensor Probe in a Bubbly Flow

Bubbly flow phenomenon is the most common flow pattern in nuclear plant system. In this paper, according to Hibiki and Bartel, the experiment was designed to observe the fluid conditions surrounding nuclear rod. In recent years, double sensor probe is one of the measuring techniques for the bubbly flow. It can measure local void fraction and bubble velocity. After mathematical statistical calculation, interfacial area concentration is obtained by Kataoka. The double sensor probe method, with the advantage for measuring local interfacial area concentration, has become widely used in many measurement methods. The paper of Liu and Zhao were referred to establish the post-processing for the raw data obtained from measuring instrument. After drawing the signal of the probe, it is important to analyze the raw data for the elimination of unnecessary noise signal and highlight the characteristic signal. Based on the same experimental condition, the different filtering methods, Simple Moving Average (SMA) and Gaussian average, were compared and discussed by the double sensor probe.

42 ENGINEERING↗

Simultaneous Momentum and Position Measurement and the Instrumental Weyl-Heisenberg Group

The canonical commutation relation, [Q,P]=iℏ, stands at the foundation of quantum theory and the original Hilbert space. The interpretation of P and Q as observables has always relied on the analogies that exist between the unitary transformations of Hilbert space and the canonical (also known as contact) transformations of classical phase space. Now that the theory of quantum measurement is essentially complete (this took a while), it is possible to revisit the canonical commutation relation in a way that sets the foundation of quantum theory not on unitary transformations but on positive transformations. This paper shows how the concept of simultaneous measurement leads to a fundamental differential geometric problem whose solution shows us the following. The simultaneous P and Q measurement (SPQM) defines a universal measuring instrument, which takes the shape of a seven-dimensional manifold, a universal covering group we call the instrumental Weyl-Heisenberg (IWH) group. The group IWH connects the identity to classical phase space in unexpected ways that are significant enough that the positive-operator-valued measure (POVM) offers a complete alternative to energy quantization. Five of the dimensions define processes that can be easily recognized and understood. The other two dimensions, the normalization and phase in the center of the IWH group, are less familiar. The normalization, in particular, requires special handling in order to describe and understand the SPQM instrument.

47 OTHER INSTRUMENTATION↗

Quantum dynamics of a small symmetry breaking measurement device

Highlights: • Ferromagnetic measurement device exploits symmetry breaking to measure a spin. • Quantum interaction results in loss of phase coherence of test object. • Dynamics lead to sizeable correlation with, and enhancement of, microscopic object. • No reliable registration of pointer readings is observed after decoupling spin. - Abstract: A quantum measuring instrument is constructed that utilises symmetry breaking to enhance a microscopic signal. The entire quantum system consists of a system–apparatus–environment triad that is composed of a small set of spin-1/2 particles. The apparatus is a ferromagnet that measures the z-component of a single spin. A full quantum many-body calculation allows for a careful examination of the loss of phase coherence, the formation and amplification of system–apparatus correlations, the irreversibility of registration, the fault tolerance, and the bias of the device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Validation of Simulations Using Full-field Measurement Techniques

The calibration by reference materials of dynamic full-field measurement systems is discussed together with their use to validate numerical simulations of structural mechanics. The discussion addresses three challenges that are faced in these processes, i.e. how to calibrate a measuring instrument that (i) provides full-field data, and (ii) is dynamic; (iii) how to compare data from simulation and experimentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method to Calculate Uncertainty Estimate of Measuring Shortwave Solar Irradiance using Thermopile and Semiconductor Solar Radiometers

The uncertainty of measuring solar irradiance is fundamentally important for solar energy and atmospheric science applications. Without an uncertainty statement, the quality of a result, model, or testing method cannot be quantified, the chain of traceability is broken, and confidence cannot be maintained in the measurement. Measurement results are incomplete and meaningless without a statementof the estimated uncertainty with traceability to the International System of Units (SI) or to another internationally recognized standard. This report explains how to use International Guidelines of Uncertainty in Measurement (GUM) to calculate such uncertainty. The report also shows that without appropriate corrections to solar measuring instruments (solar radiometers), the uncertainty ofmeasuring shortwave solar irradiance can exceed 4% using present state-of-the-art pyranometers and 2.7% using present state-of-the-art pyrheliometers. Finally, the report demonstrates that by applying the appropriate corrections, uncertainties may be reduced by at least 50%. The uncertainties, with or without the appropriate corrections might not be compatible with the needs of solar energy andatmospheric science applications; yet, this report may shed some light on the sources of uncertainties and the means to reduce overall uncertainty in measuring solar irradiance.

14 SOLAR ENERGY↗

Super-resolution surface slope metrology of x-ray mirrors

We present experimental, analytical, and numerical methods developed for reconstruction (deconvolution) of one-dimensional (1D) surface slope profiles over the spatial frequency range where the raw data are significantly perturbed due to the limited resolution of the measurement instrument. We characterize the spatial resolution properties of a profiler with the instrument's transfer function (ITF). To precisely measure the ITF, we apply a recently developed method utilizing test surfaces with 1D linear chirped height profiles of constant slope amplitude. Based on the results of the ITF calibration, we determine parameters of an analytical model for the ITF that is used in the original reconstruction software. Here, we treat surface slope metrology data obtained with the Optical Surface Measuring System (OSMS), using as a sensor an electronic autocollimator (AC) ELCOMAT-3000. The spatial resolution of the OSMS is limited by the size of the AC light-beam-collimating aperture. For the purposes of this investigation, the OSMS is equipped with a circular aperture with a diameter of 2.5 mm. This is a typical arrangement of most AC-based slope profilers developed for surface slope metrology of state-of-the-art x-ray mirrors. Using the example of surface slope metrology of two state-of-the-art elliptically shaped x-ray focusing mirrors, we demonstrate that the developed data reconstruction procedure allows us to significantly improve the accuracy of surface slope metrology with the OSMS over the spatial wavelength range from ~1.6 mm to 7 mm. Thus, the amplitude of the quasi-periodic error characteristic of the deterministic polishing process used appears to be higher by a factor of~2 than is apparent from the rough metrology data. Underestimation of the surface slope errors in this spatial wavelength range can lead to serious errors in the expected performance of x-ray mirrors in synchrotron beamlines, especially at modern light sources utilizing coherent x rays, where the perturbations can lead to increased speckle-like intensity variation.

47 OTHER INSTRUMENTATION↗

Analysis of Differential Die Away Instrument Simulated Performance Using Boiling Water Reactor Spent Fuel Assemblies

As part of evaluating the performance of various Non-Destructive Assay (NDA) instruments measuring the plutonium content and other information about spent nuclear fuel, the Next Generation of Safeguards Initiative (NGSI) Spent Fuel (SF) Project generated spent fuel libraries containing the composition of spent fuel assemblies originating from various reactors, initial enrichments (IE), burnups (BU), and cooling times (CT). Spent Fuel Library (SFL) number 5 (SFL5), representing Boiling Water Reactor (BWR) assemblies, was created as part of a “Gentleman’s Agreement” with Sweden to examine if the Differential Die Away (DDA) instrument performs similarly for BWR assemblies as for the Pressurized Water Reactor (PWR) ones. The difference between PWRs and BWRs is that BWRs have a large axial variation in moderator density because it is in the form of water at the bottom of the reactor but turns into steam as it gets warmer at the top of the reactor; thus, more plutonium builds up at the bottom of each assembly than at the top. In a PWR, the moderator density varies slightly from the bottom to the top, but since it is pressurized, the changes are not as significant with respect to the burnup and plutonium distributions. BWR assemblies are also typically smaller than PWR ones, which could affect detector performance. Since Sweden has both PWR and BWR assemblies, it is anticipated that we will be deploying the DDA instrument to measure both spent fuel assembly (SFA) types.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Underestimation of column NO 2 amounts from the OMI satellite compared to diurnally varying ground-based retrievals from multiple PANDORA spectrometer instruments

Retrievals of total column NO 2 (TCNO 2 ) are compared for 14 sites from the Ozone Measuring Instrument (OMI using OMNO2-NASA v3.1) on the AURA satellite and from multiple ground-based PANDORA spectrometer instruments making direct-sun measurements. While OMI accurately provides the daily global distribution of retrieved TCNO 2 , OMI almost always underestimates the local amount of TCNO 2 by 50 % to 100 % in polluted areas, while occasionally the daily OMI value exceeds that measured by PANDORA at very clean sites. Compared to local ground-based or aircraft measurements, OMI cannot resolve spatially variable TCNO 2 pollution within a city or urban areas, which makes it less suitable for air quality assessments related to human health. In addition to systematic underestimates in polluted areas, OMI's selected 13:30 Equator crossing timepolar orbit causes it to miss the frequently much higher values of TCNO 2 that occur before or after the OMI overpass time. Six discussed Northern Hemisphere PANDORA sites have multi-year data records (Busan,Seoul, Washington DC, Waterflow, New Mexico, Boulder, Colorado, and Mauna Loa),and one site in the Southern Hemisphere (Buenos Aires, Argentina). The first four of these sites and Buenos Aires frequently have high TCNO 2 (TCNO 2 > 0.5 DU). Eight additional sites have shorter-term data records in the US and South Korea. One of these is a 1-year data record from a highly polluted site at City College in New York City with pollution levels comparable to Seoul, South Korea. OMI-estimated air mass factor, surface reflectivity, and the OMI 24 km × 13 km FOV (field of view)are three factors that can cause OMI to underestimate TCNO 2 . Because of the local inhomogeneity of NO x emissions, the large OMI FOV is the most likely factor for consistent underestimates when comparing OMI TCNO 2 to retrievals from the small PANDORA effective FOV (measured in m 2 ) calculated from the solar diameter of 0.5°.

47 OTHER INSTRUMENTATION↗

Fluorescence of ceramic color standards

Fluorescence has been found in color standards available for use in calibration and verification of color measuring instruments. The fluorescence is excited at wavelengths below about 600 nm and emitted above 700 nm, within the response range of silicon photodiodes, but at the edge of the response of most photomultipliers and outside the range commonly scanned in commercial colorimeters. The degree of fluorescence on two of a set of 12 glossy ceramic tiles is enough to introduce significant error when those tiles have been calibrated in one mode of measurement and are used in another. We report the nature of the fluorescence and the implications for color measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Model Evaluation by Measurements from Collocated Remote Sensors in Complex Terrain

Model improvement efforts involve an evaluation of changes in model skill in response to changes in model physics and parameterization. When using wind measurements from various remote sensors to determine model forecast accuracy, it is important to understand the effects of measurement-uncertainty differences among the sensors resulting from differences in the methods of measurement, the vertical and temporal resolution of the measurements, and the spatial variability of these differences. Here we quantify instrument measurement variability in 80-m wind speed during WFIP2 and its impact on the calculated errors and the change in error from one model version to another. Here the model versions tested involved updates in model physics from HRRRv1 to HRRRv4, and reductions in grid interval from 3 km to 750 m. Model errors were found to be 2–3 m s –1 . Differences in errors as determined by various instruments at each site amounted to about 10% of this value, or 0.2–0.3 m s –1 . Changes in model skill due to physics or grid-resolution updates also differed depending on the instrument used to determine the errors; most of the instrument-to-instrument differences were ~0.1 m s –1 , but some reached 0.3 m s –1 . All instruments at a given site mostly showed consistency in the sign of the change in error. In two examples, though, the sign changed, illustrating a consequence of differences in measurements: errors determined using one instrument may show improvement in model skill, whereas errors determined using another instrument may indicate degradation. This possibility underscores the importance of having accurate measurements to determine the model error.

54 ENVIRONMENTAL SCIENCES↗

Implications of asymmetric beam geometry for convergent acoustic Doppler profilers

The focus of this research is to develop a measurement instrument to characterize complex flows at spatial and temporal resolutions pertinent to understanding hydrodynamic loads in zones of fluid-structure interaction. Foundational work has demonstrated that flow velocities can be measured at a fixed focal point using a convergent array of acoustic Doppler profiling (C-ADP) instruments. As an extension of this concept, the following approach describes an application of the technology to facilitate 3D velocity measurements at a dynamically adjustable focal point location. Furthermore, the ability to dynamically control the focal point location in real-time allows the instrument to survey velocities within a three-dimensional velocity field. The resulting configuration targets a combination of measurement fidelity and control that has not been achieved by existing remote flow measurement instrumentation in the marine environment.

Harding, Samuel F.↗

Comprehensive Performance Calibration Guidance for Perovskites and Other Emerging Solar Cells

Emerging photovoltaic (PV) technologies (e.g., organic, perovskite, and solution processed quantum dot) have attracted remarkable attention with the rapid growth of their efficiencies, and their transition toward commercialization. Accurate and reliable efficiency measurements of these PV technologies are crucial, yet much more complicated than for conventional PV technologies due to the former's pronounced dynamic responses to changes in measurement conditions (e.g., current–voltage (I–V) scan rate and preconditioning) and their susceptibility to degradation. Adjustments to the measurement procedures are therefore necessary so that a reproducible “steady state” is reached during measurement. Furthermore, given the small size of many emerging cells, inappropriate device area definition and solar simulator setup can lead to measurement errors. Here, comprehensive efficiency calibration guidance is offered for emerging solar cells, including area measurement; spectral irradiance translation to standard test conditions; and steady-state electrical performance. The necessity of reporting steady-state efficiency is justified with a statistical performance comparison between conventional and steady-state I–V scans over hundreds of cells the group has received globally for efficiency certifications. The procedures described here do not require specialized measurement instrumentation; what matters most are changes to the measurement protocols. These described changes aim to enable better comparisons between reported efficiencies.

14 SOLAR ENERGY↗

Solar Resource Measurements in Canyon, Texas - Equipment Only Loan: Cooperative Research and Development Final Report, CRADA Number CRD-07-233

Site-specific, long-term, continuous, and high-resolution measurements of solar irradiance are important for developing renewable resource data. These data are used for several research and development activities consistent with the NREL mission: establish a national 30-year climatological database of measured solar irradiances; provide high-quality ground-truth data for satellite remote sensing validation; support development of radiative transfer models for estimating solar irradiance from available meteorological observations; and provide solar resource information needed for technology deployment and operations. Data acquired under this agreement will be available to the public through NREL's Measurement & Instrumentation Data Center (MIDC) or the Renewable Resource Data Center (RReDC). The MIDC offers a variety of standard data display, access, and analysis tools designed to address the needs of a wide user audience (e.g., industry, academia, and government interests).

14 SOLAR ENERGY↗

Human System Simulation in Support of Human Performance Technical Basis at NPPs

This paper focuses on strategies and progress toward establishing the Idaho National Laboratory’s (INL’s) Human Systems Simulator Laboratory at the Center for Advanced Energy Studies (CAES), a consortium of Idaho State Universities. The INL is one of the National Laboratories of the US Department of Energy. One of the first planned applications for the Human Systems Simulator Laboratory is implementation of a dynamic nuclear power plant simulation (NPP) where studies of operator workload, situation awareness, performance and preference will be carried out in simulated control rooms including nuclear power plant control rooms. Simulation offers a means by which to review operational concepts, improve design practices and provide a technical basis for licensing decisions. In preparation for the next generation power plant and current government and industry efforts in support of light water reactor sustainability, human operators will be attached to a suite of physiological measurement instruments and, in combination with traditional Human Factors Measurement techniques, carry out control room tasks in simulated advanced digital and hybrid analog/digital control rooms. The current focus of the Human Systems Simulator Laboratory is building core competence in quantitative and qualitative measurements of situation awareness and workload. Of particular interest is whether introduction of digital systems including automated procedures has the potential to reduce workload and enhance safety while improving situation awareness or whether workload is merely shifted and situation awareness is modified in yet to be determined ways. Data analysis is carried out by engineers and scientists and includes measures of the physical and neurological correlates of human performance. The current approach supports a user-centered design philosophy (see ISO 13407 “Human Centered Design Process for Interactive Systems, 1999) wherein the context for task performance along with the requirements of the end-user are taken into account during the design process and the validity of design is determined through testing of real end users

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Aerosol Microphysics and Chemical Measurements at Mt. Soledad and Scripps Pier during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) from February 2023 to February 2024 UCSD Library Collection

This dataset includes guest instrument measurements and other PI products for aerosol microphysics and chemical measurements collected at Mt. Soledad and Scripps Pier during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) from February 2023 to February 2024. The measurements include the following instruments at Mt. Soledad: High-Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS, Aerodyne), Scanning Electrical Mobility Spectrometer (SEMS, Brechtel Manufacturing Inc.), Aerodynamic Particle Sizer (APS, Droplet Measurements Technologies), Single Particle Soot Photometer (SP2, Drople Measurements Technologies), Meteorological Station (WXT520, Vaisala), Ozone (Teco), and trace gas proxies (Teledyne). In addition, the analyses of particle filters collected at Mt. Soledad for three dry-diameter size cuts (<1 micron, <0.5 micron, <0.18 micron) and at Scripps Pier for one dry-diameter size cut (<1 micron) by Fourier Transform Infrared (FTIR) and X-ray Fluorescence (XRF) are reported. A differential mobility analyzer operated as a scanning mobility particle sizer (SMPS, TSI Inc.), a printed particle optical spectrometer (POPS, Grimm), and a continuous flow diffusion cloud condensation nuclei (CCN, DMT) counter provide the mobility aerosol size distribution (30-360 nm), optical size distribution (150 - 6000 nm), size-resolved CCN distribution (30-360 nm) at 0.2, 0.4, 0.6, 0.8, and 1.0% supersaturation. Measurements are reported for both sampling from an isokinetic aerosol inlet and from a Counterflow Virtual Impactor (CVI, Brechtel Manufacturing Inc.). The data are available at the following link: https://library.ucsd.edu/dc/collection/bb0898306q

54 ENVIRONMENTAL SCIENCES↗